Skip to main content

Showing 1–5 of 5 results for author: Herrero-Bosch, V

.
  1. arXiv:2210.07625  [pdf, other

    physics.ins-det hep-ex

    Measurement of the scintillation resolution in liquid xenon and its impact for future segmented calorimeters

    Authors: C. Romo-Luque, J. M. Benlloch-Rodríguez, V. Herrero-Bosch, N. Salor-Iguiñiz, R. J. Aliaga, V. Álvarez, F. Ballester, R. Esteve, R. Gadea, J. Generowicz, A. Laing, F. Monrabal, M. Querol, M. Rappaport, J. Rodríguez, J. Rodríguez-Ponce, S. Teruel-Pardo, J. F. Toledo, R. Torres-Curado, P. Ferrario, J. J. Gómez-Cadenas

    Abstract: We report on a new measurement of the energy resolution that can be attained in liquid xenon when recording only the scintillation light. Our setup is optimised to maximise light collection, and uses state-of-the-art, high-PDE, VUV-sensitive silicon photomultipliers. We find a value of 4.2% +- 0.2% FWHM at 511 keV, a result much better than previous measurements and close to the Poissonian resolut… ▽ More

    Submitted 26 January, 2023; v1 submitted 14 October, 2022; originally announced October 2022.

  2. arXiv:2109.12899  [pdf, other

    physics.ins-det physics.med-ph

    Monte Carlo characterization of PETALO, a full-body liquid xenon-based PET detector

    Authors: J. Renner, C. Romo-Luque, R. J. Aliaga, V. Álvarez, F. Ballester, J. M. Benlloch-Rodríguez, J. V. Carrión, D. Cubero, J. Díaz, R. Esteve, R. Gadea, J. Gillam, J. Generowicz, J. L. López-Gómez, A. Martínez, F. Monrabal, M. Querol, M. Rappaport, J. Rodríguez, J. Rodríguez-Ponce, P. Solevi, S. Teruel-Pardo, J. F. Toledo, R. Torres-Curado, V. Herrero-Bosch , et al. (2 additional authors not shown)

    Abstract: New detector approaches in Positron Emission Tomography imaging will play an important role in reducing costs, lowering administered radiation doses, and improving overall performance. PETALO employs liquid xenon as the active scintillating medium and UV-sensitive silicon photomultipliers for scintillation readout. The scintillation time in liquid xenon is fast enough to register time-of-flight in… ▽ More

    Submitted 11 January, 2023; v1 submitted 27 September, 2021; originally announced September 2021.

    Journal ref: JINST 17 (2022) P05044

  3. PETALO read-out: A novel approach for data acquisition systems in PET applications

    Authors: V. Herrero-Bosch, R. Gadea, R. J. Aliaga, J. Rodríguez, J. F. Toledo, R. Torres-Curado, F. Ballester, R. Esteve, J. J. Gómez-Cadenas, P. Ferrario

    Abstract: PETALO (a Positron Emission Tof Apparatus based on Liquid xenOn) is a new approach for Positron Emission Tomography scanners, based on liquid xenon. The PETALO detector aims at capturing the light produced by the scintillation in LXe taking advantage of its uniform response and continuity. This strategy will lead to a geometrical distortion free behavior compared to other PET detectors. To this en… ▽ More

    Submitted 1 March, 2021; v1 submitted 25 January, 2021; originally announced January 2021.

  4. arXiv:2001.04724  [pdf, other

    physics.ins-det

    Processing of Compton events in the PETALO readout system

    Authors: J. Renner, J. M. Benlloch-Rodríguez, J. V. Carrión, R. Gadea, V. Herrero-Bosch, M. Kekic, C. Romo-Luque, P. Ferrario, J. J. Gómez-Cadenas

    Abstract: PETALO (Positron Emission TOF Apparatus based on Liquid xenOn) exploits the unique characteristics of liquid xenon as a scintillator for use in a PET detector. Here initial simulation studies are detailed which highlight the potential of such a detector and outline the steps taken in the reconstruction of 511 keV gamma rays and in the full PET image reconstruction. In particular, a neural network-… ▽ More

    Submitted 14 January, 2020; originally announced January 2020.

    Comments: Presented at the 2019 IEEE Nuclear Science Symposium and Medical Imaging Conference

  5. arXiv:1911.10994  [pdf, other

    physics.ins-det physics.med-ph

    PETALO: Time-of-Flight PET with liquid xenon

    Authors: Paola Ferrario, Vicente Herrero-Bosch, José María Benlloch-Rodríguez, Carmen Romo-Luque, Jun José Gómez-Cadenas

    Abstract: The fast scintillation decay time and the high scintillation yield of liquid xenon makes it an appropriate material for nuclear medicine. Moreover, being a continuous medium with a uniform response, liquid xenon allows one to avoid most of the geometrical distortions of conventional detectors based on scintillating crystals. In this paper, we describe how these properties have motivated the develo… ▽ More

    Submitted 22 November, 2019; originally announced November 2019.

    Comments: arXiv admin note: text overlap with arXiv:1712.05751

    Journal ref: Published in 2018 IEEE Nuclear Science Symposium and Medical Imaging Conference Proceedings (NSS/MIC)