-
Characterization in Geant4 of different PET configurations
Authors:
M. L. López Toxqui,
C. H. Zepeda Fernández,
L. F. Rebolledo Herrera,
B. De Celis Alonso,
E. Moreno Barbosa
Abstract:
Positron Emission Tomography (PET) is a Nuclear Medicine technique that creates images that allow the study of metabolic activity and organ function using radiopharmaceuticals. Continuous improvement of scintillation detectors for radiation in PET as well as improvement in electronic detectors (e.g., SiPMs) and signal processing, makes the field of PET a fast and changing environment. If industry…
▽ More
Positron Emission Tomography (PET) is a Nuclear Medicine technique that creates images that allow the study of metabolic activity and organ function using radiopharmaceuticals. Continuous improvement of scintillation detectors for radiation in PET as well as improvement in electronic detectors (e.g., SiPMs) and signal processing, makes the field of PET a fast and changing environment. If industry desires to build new systems implementing these technological improvements, it is of its interest to develop modelling strategies that can provide information on how to build them, reducing time and material costs. Bearing this in mind three different PET configurations, were simulated in Geant4, to determine which one presented the best performance according to quality parameters such as spatial resolution (SR), coincident time resolution (CTR) and acceptance value (A). This was done with three different (in size) pairs of LYSO crystals + SiPM detectors. It was found that the 2 Modules system presented worst results than the two Ring detector configurations. Between the Ring configurations the first was marginally better than the second.
△ Less
Submitted 6 November, 2023;
originally announced November 2023.
-
Status and initial physics performance studies of the MPD experiment at NICA
Authors:
MPD Collaboration,
V. Abgaryan,
R. Acevedo Kado,
S. V. Afanasyev,
G. N. Agakishiev,
E. Alpatov,
G. Altsybeev,
M. Alvarado Hernández,
S. V. Andreeva,
T. V. Andreeva,
E. V. Andronov,
N. V. Anfimov,
A. A. Aparin,
V. I. Astakhov,
E. Atkin,
T. Aushev,
G. S. Averichev,
A. V. Averyanov,
A. Ayala,
V. A. Babkin,
T. Babutsidze,
I. A. Balashov,
A. Bancer,
M. Yu. Barabanov,
D. A. Baranov
, et al. (454 additional authors not shown)
Abstract:
The Nuclotron-base Ion Collider fAcility (NICA) is under construction at the Joint Institute for Nuclear Research (JINR), with commissioning of the facility expected in late 2022. The Multi-Purpose Detector (MPD) has been designed to operate at NICA and its components are currently in production. The detector is expected to be ready for data taking with the first beams from NICA. This document pro…
▽ More
The Nuclotron-base Ion Collider fAcility (NICA) is under construction at the Joint Institute for Nuclear Research (JINR), with commissioning of the facility expected in late 2022. The Multi-Purpose Detector (MPD) has been designed to operate at NICA and its components are currently in production. The detector is expected to be ready for data taking with the first beams from NICA. This document provides an overview of the landscape of the investigation of the QCD phase diagram in the region of maximum baryonic density, where NICA and MPD will be able to provide significant and unique input. It also provides a detailed description of the MPD set-up, including its various subsystems as well as its support and computing infrastructures. Selected performance studies for particular physics measurements at MPD are presented and discussed in the context of existing data and theoretical expectations.
△ Less
Submitted 16 February, 2022;
originally announced February 2022.
-
Performance of BeBe, a proposed dedicated beam-beam monitoring detector for the MPD-NICA experiment at JINR
Authors:
Marco Alberto Ayala Torres,
Lucina Gabriela Espinoza Beltrán,
Marcos Aurelio Fontaine Sánchez,
Luis A. Hernández-Cruz,
Luis Manuel Montaño,
Braian Adair Maldonado Luna,
Eduardo Moreno-Barbosa,
Lucio Fidel Rebolledo Herrera,
Mario Rodríguez-Cahuantzi,
Valeria Z. Reyna-Ortiz,
Guillermo Tejeda-Muñoz,
C. H. Zepeda Fernández
Abstract:
The Multipurpose Detector (MPD) is an experimental array, currently under construction, designed to study the nuclear matter created during the collisions that will be provided by the Nuclotron-based Ion Collider fAcility (NICA) at JINR. The MPD-NICA experiment consists of a typical array of particle detectors as those used to study heavy-ion collisions at LHC and RHIC. To increase the trigger cap…
▽ More
The Multipurpose Detector (MPD) is an experimental array, currently under construction, designed to study the nuclear matter created during the collisions that will be provided by the Nuclotron-based Ion Collider fAcility (NICA) at JINR. The MPD-NICA experiment consists of a typical array of particle detectors as those used to study heavy-ion collisions at LHC and RHIC. To increase the trigger capabilities of MPD for stage 2 of NICA operation, a detector conformed by two arrays of 80 plastic scintillator cells each located symmetrically at opposite sides of the interaction point of MPD is proposed (BeBe). Based on Monte Carlo simulations, a discussion of the potential physics performance of BeBe detector is given for triggering tasks and for the resolution in the determination of the event plane reaction and the centrality of the collisions at NICA. Also, laboratory measurements to estimate the time resolution of individual BeBe cells prototypes are presented. It is shown that a time resolution between 0.65 and 1.48 ns can be reached depending on the number of photosensors employed to collect the scintillation photons. The BeBe detector will be complementary to FFD and FHCAL forward detectors.
△ Less
Submitted 24 August, 2022; v1 submitted 6 October, 2021;
originally announced October 2021.
-
Intrinsic time resolution and efficiency characterization for two size of BC-404 plastic scintillators studies in Geant4
Authors:
Cristian Heber Zepeda Fernández,
Lucio Fidel Rebolledo Herrera,
Eduardo Moreno Barbosa,
Edmundo Márquez Quintos
Abstract:
The time resolution (TR) is one of the most important characteristic of a detector. For the case of a scintillator, the collection of light also is important, it depends of the effective area of the photo-sensor (\textit{Scorer}). The Photomultipliers Tubes (PMTs), normally, have an effective area greater than the Silicon Photomultipliers (SiPMs), however, due to its voltage of operation, their si…
▽ More
The time resolution (TR) is one of the most important characteristic of a detector. For the case of a scintillator, the collection of light also is important, it depends of the effective area of the photo-sensor (\textit{Scorer}). The Photomultipliers Tubes (PMTs), normally, have an effective area greater than the Silicon Photomultipliers (SiPMs), however, due to its voltage of operation, their size or cost, in some cases it can be difficult to work with them. In which case, it is preferable to use SiPMs. The value of TR also depends of the size and geometry of the scintillator, number of photo-sensors and the electronic part.\\ In this work, we study the mean optical photon arrival time distribution (AT) to a Scorer from a SiPM of 6$\times$6~mm$^2$. We define the variation of AT as \textit{the intrinsic time resolution} (ITR). In Geant4, we simulated two different geometries: square and hexagonal, for a BC-404 plastic scintillator coupled to one Scorer. The sources simulated were Sr$^{90}$, Co$^{60}$, Cs$^{137}$, Na$^{22}$ and $μ^-$ of 1~GeV. It is shown that AT and ITR depends of the geometry and size of the plastic scintillator, the location of the Scorer, the incident particle and its energy. Then, the ITR and therefore the TR is not a constant for a detector. Finally, we show the relation between AT and the deposited energy by the particle incident, which are related in the experiment to the response time event of the detector and the deposited charge by the incident particle, respectively.
△ Less
Submitted 8 June, 2021;
originally announced June 2021.