-
Cherenkov Telescope Array Contributions to the 35th International Cosmic Ray Conference (ICRC2017)
Authors:
F. Acero,
B. S. Acharya,
V. Acín Portella,
C. Adams,
I. Agudo,
F. Aharonian,
I. Al Samarai,
A. Alberdi,
M. Alcubierre,
R. Alfaro,
J. Alfaro,
C. Alispach,
R. Aloisio,
R. Alves Batista,
J. -P. Amans,
E. Amato,
L. Ambrogi,
G. Ambrosi,
M. Ambrosio,
J. Anderson,
M. Anduze,
E. O. Angüner,
E. Antolini,
L. A. Antonelli,
V. Antonuccio
, et al. (1117 additional authors not shown)
Abstract:
List of contributions from the Cherenkov Telescope Array Consortium presented at the 35th International Cosmic Ray Conference, July 12-20 2017, Busan, Korea.
List of contributions from the Cherenkov Telescope Array Consortium presented at the 35th International Cosmic Ray Conference, July 12-20 2017, Busan, Korea.
△ Less
Submitted 24 October, 2017; v1 submitted 11 September, 2017;
originally announced September 2017.
-
Contributions of the Cherenkov Telescope Array (CTA) to the 6th International Symposium on High-Energy Gamma-Ray Astronomy (Gamma 2016)
Authors:
The CTA Consortium,
:,
A. Abchiche,
U. Abeysekara,
Ó. Abril,
F. Acero,
B. S. Acharya,
C. Adams,
G. Agnetta,
F. Aharonian,
A. Akhperjanian,
A. Albert,
M. Alcubierre,
J. Alfaro,
R. Alfaro,
A. J. Allafort,
R. Aloisio,
J. -P. Amans,
E. Amato,
L. Ambrogi,
G. Ambrosi,
M. Ambrosio,
J. Anderson,
M. Anduze,
E. O. Angüner
, et al. (1387 additional authors not shown)
Abstract:
List of contributions from the Cherenkov Telescope Array (CTA) Consortium presented at the 6th International Symposium on High-Energy Gamma-Ray Astronomy (Gamma 2016), July 11-15, 2016, in Heidelberg, Germany.
List of contributions from the Cherenkov Telescope Array (CTA) Consortium presented at the 6th International Symposium on High-Energy Gamma-Ray Astronomy (Gamma 2016), July 11-15, 2016, in Heidelberg, Germany.
△ Less
Submitted 17 October, 2016;
originally announced October 2016.
-
Silicon Photomultiplier Research and Development Studies for the Large Size Telescope of the Cherenkov Telescope Array
Authors:
Riccardo Rando,
Daniele Corti,
Francesco Dazzi,
Alessandro De Angelis,
Antonios Dettlaff,
Daniela Dorner,
David Fink,
Nadia Fouque,
Felix Grundner,
Werner Haberer,
Alexander Hahn,
Richard Hermel,
Samo Korpar,
Gašper Kukec Mezek,
Ronald Maier,
Christian Manea,
Mosè Mariotti,
Daniel Mazin,
Fatima Mehrez,
Razmik Mirzoyan,
Sergey Podkladkin,
Ignasi Reichardt,
Wolfgang Rhode,
Sylvie Rosier,
Cornelia Schultz
, et al. (4 additional authors not shown)
Abstract:
The Cherenkov Telescope Array (CTA) is the the next generation facility of imaging atmospheric Cherenkov telescopes; two sites will cover both hemispheres. CTA will reach unprecedented sensitivity, energy and angular resolution in very-high-energy gamma-ray astronomy. Each CTA array will include four Large Size Telescopes (LSTs), designed to cover the low-energy range of the CTA sensitivity (…
▽ More
The Cherenkov Telescope Array (CTA) is the the next generation facility of imaging atmospheric Cherenkov telescopes; two sites will cover both hemispheres. CTA will reach unprecedented sensitivity, energy and angular resolution in very-high-energy gamma-ray astronomy. Each CTA array will include four Large Size Telescopes (LSTs), designed to cover the low-energy range of the CTA sensitivity ($\sim$20 GeV to 200 GeV). In the baseline LST design, the focal-plane camera will be instrumented with 265 photodetector clusters; each will include seven photomultiplier tubes (PMTs), with an entrance window of 1.5 inches in diameter. The PMT design is based on mature and reliable technology. Recently, silicon photomultipliers (SiPMs) are emerging as a competitor. Currently, SiPMs have advantages (e.g. lower operating voltage and tolerance to high illumination levels) and disadvantages (e.g. higher capacitance and cross talk rates), but this technology is still young and rapidly evolving. SiPM technology has a strong potential to become superior to the PMT one in terms of photon detection efficiency and price per square mm of detector area. While the advantage of SiPMs has been proven for high-density, small size cameras, it is yet to be demonstrated for large area cameras such as the one of the LST. We are working to develop a SiPM-based module for the LST camera, in view of a possible camera upgrade. We will describe the solutions we are exploring in order to balance a competitive performance with a minimal impact on the overall LST camera design.
△ Less
Submitted 28 August, 2015;
originally announced August 2015.
-
NectarCAM : a camera for the medium size telescopes of the Cherenkov Telescope Array
Authors:
J-F. Glicenstein,
O. Abril,
J-A. Barrio,
O. Blanch~Bigas,
J. Bolmont,
F. Bouyjou,
P. Brun,
E. Chabanne,
C. Champion,
S. Colonges,
P. Corona,
E. Delagnes,
C. Delgado,
C. Diaz Ginzov,
D. Durand,
J-P. Ernenwein,
S. Fegan,
O. Ferreira,
M. Fesquet,
A. Fiasson,
G. Fontaine,
N. Fouque,
D. Gascon,
B. Giebels,
F. Henault
, et al. (41 additional authors not shown)
Abstract:
NectarCAM is a camera proposed for the medium-sized telescopes of the Cherenkov Telescope Array (CTA) covering the central energy range of ~100 GeV to ~30 TeV. It has a modular design and is based on the NECTAr chip, at the heart of which is a GHz sampling Switched Capacitor Array and a 12-bit Analog to Digital converter. The camera will be equipped with 265 7-photomultiplier modules, covering a f…
▽ More
NectarCAM is a camera proposed for the medium-sized telescopes of the Cherenkov Telescope Array (CTA) covering the central energy range of ~100 GeV to ~30 TeV. It has a modular design and is based on the NECTAr chip, at the heart of which is a GHz sampling Switched Capacitor Array and a 12-bit Analog to Digital converter. The camera will be equipped with 265 7-photomultiplier modules, covering a field of view of 8 degrees. Each module includes the photomultiplier bases, high voltage supply, pre-amplifier, trigger, readout and Ethernet transceiver. The recorded events last between a few nanoseconds and tens of nanoseconds. The camera trigger will be flexible so as to minimize the read-out dead-time of the NECTAr chips. NectarCAM is designed to sustain a data rate of more than 4 kHz with less than 5\% dead time. The camera concept, the design and tests of the various subcomponents and results of thermal and electrical prototypes are presented. The design includes the mechanical structure, cooling of the electronics, read-out, clock distribution, slow control, data-acquisition, triggering, monitoring and services.
△ Less
Submitted 26 August, 2015;
originally announced August 2015.
-
CTA Contributions to the 34th International Cosmic Ray Conference (ICRC2015)
Authors:
The CTA Consortium,
:,
A. Abchiche,
U. Abeysekara,
Ó. Abril,
F. Acero,
B. S. Acharya,
M. Actis,
G. Agnetta,
J. A. Aguilar,
F. Aharonian,
A. Akhperjanian,
A. Albert,
M. Alcubierre,
R. Alfaro,
E. Aliu,
A. J. Allafort,
D. Allan,
I. Allekotte,
R. Aloisio,
J. -P. Amans,
E. Amato,
L. Ambrogi,
G. Ambrosi,
M. Ambrosio
, et al. (1290 additional authors not shown)
Abstract:
List of contributions from the CTA Consortium presented at the 34th International Cosmic Ray Conference, 30 July - 6 August 2015, The Hague, The Netherlands.
List of contributions from the CTA Consortium presented at the 34th International Cosmic Ray Conference, 30 July - 6 August 2015, The Hague, The Netherlands.
△ Less
Submitted 11 September, 2015; v1 submitted 24 August, 2015;
originally announced August 2015.
-
The Cherenkov Telescope Array Large Size Telescope
Authors:
G. Ambrosi,
Y. Awane,
H. Baba,
A. Bamba,
M. Barceló,
U. Barres de Almeida,
J. A. Barrio,
O. Blanch Bigas,
J. Boix,
L. Brunetti,
E. Carmona,
E. Chabanne,
M. Chikawa,
P. Colin,
J. L. Conteras,
J. Cortina,
F. Dazzi,
A. Deangelis,
G. Deleglise,
C. Delgado,
C. Díaz,
F. Dubois,
A. Fiasson,
D. Fink,
N. Fouque
, et al. (107 additional authors not shown)
Abstract:
The two arrays of the Very High Energy gamma-ray observatory Cherenkov Telescope Array (CTA) will include four Large Size Telescopes (LSTs) each with a 23 m diameter dish and 28 m focal distance. These telescopes will enable CTA to achieve a low-energy threshold of 20 GeV, which is critical for important studies in astrophysics, astroparticle physics and cosmology. This work presents the key speci…
▽ More
The two arrays of the Very High Energy gamma-ray observatory Cherenkov Telescope Array (CTA) will include four Large Size Telescopes (LSTs) each with a 23 m diameter dish and 28 m focal distance. These telescopes will enable CTA to achieve a low-energy threshold of 20 GeV, which is critical for important studies in astrophysics, astroparticle physics and cosmology. This work presents the key specifications and performance of the current LST design in the light of the CTA scientific objectives.
△ Less
Submitted 17 July, 2013;
originally announced July 2013.
-
The NectarCAM camera project
Authors:
J-F. Glicenstein,
M. Barcelo,
J-A. Barrio,
O. Blanch,
J. Boix,
J. Bolmont,
C. Boutonnet,
S. Cazaux,
E. Chabanne,
C. Champion,
F. Chateau,
S. Colonges,
P. Corona,
S. Couturier,
B. Courty,
E. Delagnes,
C. Delgado,
J-P. Ernenwein,
S. Fegan,
O. Ferreira,
M. Fesquet,
G. Fontaine,
N. Fouque,
F. Henault,
D. Gascón
, et al. (35 additional authors not shown)
Abstract:
In the framework of the next generation of Cherenkov telescopes, the Cherenkov Telescope Array (CTA), NectarCAM is a camera designed for the medium size telescopes covering the central energy range of 100 GeV to 30 TeV. NectarCAM will be finely pixelated (~ 1800 pixels for a 8 degree field of view, FoV) in order to image atmospheric Cherenkov showers by measuring the charge deposited within a few…
▽ More
In the framework of the next generation of Cherenkov telescopes, the Cherenkov Telescope Array (CTA), NectarCAM is a camera designed for the medium size telescopes covering the central energy range of 100 GeV to 30 TeV. NectarCAM will be finely pixelated (~ 1800 pixels for a 8 degree field of view, FoV) in order to image atmospheric Cherenkov showers by measuring the charge deposited within a few nanoseconds time-window. It will have additional features like the capacity to record the full waveform with GHz sampling for every pixel and to measure event times with nanosecond accuracy. An array of a few tens of medium size telescopes, equipped with NectarCAMs, will achieve up to a factor of ten improvement in sensitivity over existing instruments in the energy range of 100 GeV to 10 TeV. The camera is made of roughly 250 independent read-out modules, each composed of seven photo-multipliers, with their associated high voltage base and control, a read-out board and a multi-service backplane board. The read-out boards use NECTAr (New Electronics for the Cherenkov Telescope Array) ASICs which have the dual functionality of analogue memories and Analogue to Digital Converter (ADC). The camera trigger to be used will be flexible so as to minimize the read-out dead-time of the NECTAr chips. We present the camera concept and the design and tests of the various subcomponents. The design includes the mechanical parts, the cooling of the electronics, the readout, the data acquisition, the trigger, the monitoring and services.
△ Less
Submitted 17 July, 2013;
originally announced July 2013.
-
CTA contributions to the 33rd International Cosmic Ray Conference (ICRC2013)
Authors:
The CTA Consortium,
:,
O. Abril,
B. S. Acharya,
M. Actis,
G. Agnetta,
J. A. Aguilar,
F. Aharonian,
M. Ajello,
A. Akhperjanian,
M. Alcubierre,
J. Aleksic,
R. Alfaro,
E. Aliu,
A. J. Allafort,
D. Allan,
I. Allekotte,
R. Aloisio,
E. Amato,
G. Ambrosi,
M. Ambrosio,
J. Anderson,
E. O. Angüner,
L. A. Antonelli,
V. Antonuccio
, et al. (1082 additional authors not shown)
Abstract:
Compilation of CTA contributions to the proceedings of the 33rd International Cosmic Ray Conference (ICRC2013), which took place in 2-9 July, 2013, in Rio de Janeiro, Brazil
Compilation of CTA contributions to the proceedings of the 33rd International Cosmic Ray Conference (ICRC2013), which took place in 2-9 July, 2013, in Rio de Janeiro, Brazil
△ Less
Submitted 29 July, 2013; v1 submitted 8 July, 2013;
originally announced July 2013.
-
PMm2: large photomultipliers and innovative electronics for the next-generation neutrino experiments
Authors:
B. Genolini,
P. Barrillon,
S. Blin,
J. -E. Campagne,
B. Combettes,
S. Conforti,
A. -G. De-haine,
D. Duchesneau,
F. Dulucq,
N. Dumont-Dayot,
J. Favier,
F. Fouché,
R. Hermel,
C. de La Taille,
G. Martin-Chassard,
T. Nguyen Trung,
C. Périnet,
J. Peyré,
J. Pouthas,
L. Raux,
E. Rindel,
P. Rosier,
J. Tassan-Viol,
W. Wei,
A. Zghiche
Abstract:
The next generation of proton decay and neutrino experiments, the post-SuperKamiokande detectors as those that will take place in megaton size water tanks, will require very large surfaces of photodetection and a large volume of data. Even with large hemispherical photomultiplier tubes, the expected number of channels should reach hundreds of thousands. A funded R&D program to implement a soluti…
▽ More
The next generation of proton decay and neutrino experiments, the post-SuperKamiokande detectors as those that will take place in megaton size water tanks, will require very large surfaces of photodetection and a large volume of data. Even with large hemispherical photomultiplier tubes, the expected number of channels should reach hundreds of thousands. A funded R&D program to implement a solution is presented here. The very large surface of photodetection is segmented in macro pixels made of 16 hemispherical (12 inches) photomultiplier tubes connected to an autonomous front-end which works on a triggerless data acquisition mode. The expected data transmission rate is 5 Mb/s per cable, which can be achieved with existing techniques. This architecture allows to reduce considerably the cost and facilitate the industrialization. This document presents the simulations and measurements which define the requirements for the photomultipliers and the electronics. A proto-type of front-end electronics was successfully tested with 16 photomultiplier tubes supplied by a single high voltage, validating the built-in gain adjustment and the calibration principle. The first tests and calculations on the photomultiplier glass led to the study of a new package optimized for a 10 bar pressure in order to sustain the high underwater pressure.
△ Less
Submitted 17 November, 2008;
originally announced November 2008.