Skip to main content

Showing 1–10 of 10 results for author: Henschel, H

.
  1. Performance and Moli`ere radius measurements using a compact prototype of LumiCal in an electron test beam

    Authors: H. Abramowicz, A. Abusleme, K. Afanaciev, Y. Benhammou, O. Borysov, M. Borysova, I. Bozovic- Jelisavcic, W. Daniluk, D. Dannheim, M. Demichev, K. Elsener, M. Firlej, E. Firu, T. Fiutowski, V. Ghenescu, M. Gostkin, M. Hempelb, H. Henschel, M. Idzik, A. Ignatenkoc, A. Ishikawa, A. Joffe, G. Kacarevic, S. Kananov, O. Karachebanb , et al. (29 additional authors not shown)

    Abstract: A new design of a detector plane of sub-millimetre thickness for an electromagnetic sampling calorimeter is presented. It is intended to be used in the luminometers LumiCal and BeamCal in future linear $e^+e^-$ collider experiments. The detector planes were produced utilising novel connectivity scheme technologies. They were installed in a compact prototype of the calorimeter and tested at DESY wi… ▽ More

    Submitted 25 October, 2019; v1 submitted 29 December, 2018; originally announced December 2018.

    Comments: 16 pages, 28 figures, Published in EPJC. Please note: Fig 16 in the published version us incorrect. The correct one appears in this replaced version

    Journal ref: Eur. Phys. J. C79 (2019) 579

  2. Measurement of shower development and its Molière radius with a four-plane LumiCal test set-up

    Authors: H. Abramowicz, A. Abusleme, K. Afanaciev, Y. Benhammou, L. Bortko, O. Borysov, M. Borysova, I. Bozovic-Jelisavcic, G. Chelkov, W. Daniluk, D. Dannheim, K. Elsener, M. Firlej, E. Firu, T. Fiutowski, V. Ghenescu, M. Gostkin, M. Hempel, H. Henschel, M. Idzik, A. Ignatenko, A. Ishikawa, S. Kananov, O. Karacheban, W. Klempt , et al. (35 additional authors not shown)

    Abstract: A prototype of a luminometer, designed for a future e+e- collider detector, and consisting at present of a four-plane module, was tested in the CERN PS accelerator T9 beam. The objective of this beam test was to demonstrate a multi-plane tungsten/silicon operation, to study the development of the electromagnetic shower and to compare it with MC simulations. The Molière radius has been determined t… ▽ More

    Submitted 12 March, 2018; v1 submitted 10 May, 2017; originally announced May 2017.

    Comments: Paper published in Eur. Phys. J., includes 25 figures and 3 Tables

    Journal ref: Eur. Phys. J. C 78 (2018) 135

  3. arXiv:1504.04023  [pdf, ps, other

    physics.ins-det hep-ex

    Investigation of a direction sensitive sapphire detector stack at the 5 GeV electron beam at DESY-II

    Authors: O. Karacheban, K. Afanaciev, M. Hempel, H. Henschel, W. Lange, J. L. Leonard, I. Levy, W. Lohmann, S. Schuwalow

    Abstract: Extremely radiation hard sensors are needed in particle physics experiments to instrument the region near the beam pipe. Examples are beam halo and beam loss monitors at the Large Hadron Collider, FLASH or XFEL. Currently artificial diamond sensors are widely used. In this paper single crystal sapphire sensors are considered as a promising alternative. Industrially grown sapphire wafers are availa… ▽ More

    Submitted 15 July, 2015; v1 submitted 15 April, 2015; originally announced April 2015.

    Comments: 13 pages, 7 figures, 3 tables

  4. arXiv:1411.4924  [pdf, other

    physics.ins-det

    ECFA Detector R&D Panel, Review Report

    Authors: The FCAL Collaboration, H. Abramowicz, A. Abusleme, K. Afanaciev, J. Aguilar, E. Alvarez, P. Bambade, L. Bortko, I. Bozovic-Jelisavcic, E. Castro, G. Chelkov, C. Coca, W. Daniluk, A. Dragone, L. Dumitru, K. Elsener, I. Emeliantchik, E. Firu, J. Fischer, T. Fiutowski, V. Ghenescu, M. Gostkin, G. Grzelak, G. Haller, H. Henschel , et al. (46 additional authors not shown)

    Abstract: Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than 10$^{-3}$ at the ILC and 10$^{-2}$ at CLIC, and a low polar-angle calorimeter (BeamCal). The latter will be hit by a large amount of beamstrahlung remnants. The in… ▽ More

    Submitted 19 November, 2014; v1 submitted 18 November, 2014; originally announced November 2014.

    Comments: 61 pages, 51 figures

    Report number: LC-DET-2013-029

  5. arXiv:1411.4431  [pdf, other

    physics.ins-det

    Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector

    Authors: The FCAL Collaboration, H. Abramowicz, A. Abusleme, K. Afanaciev, J. Aguilar, E. Alvarez, D. Avila, Y. Benhammou, L. Bortko, O. Borysov, M. Bergholz, I. Bozovic-Jelisavcic, E. Castro, G. Chelkov, C. Coca, W. Daniluk, L. Dumitru, K. Elsener, V. Fadeyev, M. Firlej, E. Firu, T. Fiutowski, V. Ghenescu, M. Gostkin, H. Henschel , et al. (44 additional authors not shown)

    Abstract: Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio and the response as a function of the position of the sens… ▽ More

    Submitted 1 June, 2015; v1 submitted 17 November, 2014; originally announced November 2014.

    Comments: 25 pages, 32 figures, revised version following comments from referees

    Journal ref: JINST 10, P05009 (2015)

  6. Comment on 'Enhancement in the production of nucleating clusters due to dimethylamine and large uncertainties in the thermochemistry of amine-enhanced nucleation' by Nadykto et al., Chem. Phys. Lett., 609, 42-49 (2014)

    Authors: Oona Kupiainen-Määttä, Henning Henschel, Theo Kurtén, Ville Loukonen, Tinja Olenius, Pauli Paasonen, Hanna Vehkamäki

    Abstract: We comment on a study by Nadykto et al. recently published in this journal. Earlier work from our group has been misrepresented in this study, and we feel that the claims made need to be amended. Also the analysis of Nadykto et al. concerning the implications of their own density functional calculations is incomplete. We present cluster formation simulations allowing more conclusions to be drawn f… ▽ More

    Submitted 3 October, 2014; originally announced October 2014.

    Comments: 8 pages, 3 figures, submitted to Chemical Physics Letters

  7. arXiv:1405.1926  [pdf

    physics.ins-det hep-ex

    Fast Beam Condition Monitor for CMS: performance and upgrade

    Authors: Jessica L. Leonard, Alan Bell, Piotr Burtowy, Anne Dabrowski, Maria Hempel, Hans Henschel, Wolfgang Lange, Wolfgang Lohmann, Nathaniel Odell, Marek Penno, Brian Pollack, Dominik Przyborowski, Vladimir Ryjov, David Stickland, Roberval Walsh, Weronika Warzycha, Agnieszka Zagozdzinska

    Abstract: The CMS beam and radiation monitoring subsystem BCM1F (Fast Beam Condition Monitor) consists of 8 individual diamond sensors situated around the beam pipe within the pixel detector volume, for the purpose of fast bunch-by-bunch monitoring of beam background and collision products. In addition, effort is ongoing to use BCM1F as an online luminosity monitor. BCM1F will be running whenever there is b… ▽ More

    Submitted 8 May, 2014; originally announced May 2014.

    Comments: 10 pages, 8 figures. To be published in NIM A as proceedings for the 9th Hiroshima Symposium on Semiconductor Tracking Detectors (2013)

    Report number: DESY 14-070

    Journal ref: Nuclear Inst. and Methods in Physics Research, A (2014), pp. 235-239

  8. arXiv:1201.4657  [pdf

    physics.ins-det hep-ex

    Infrastructure for Detector Research and Development towards the International Linear Collider

    Authors: J. Aguilar, P. Ambalathankandy, T. Fiutowski, M. Idzik, Sz. Kulis, D. Przyborowski, K. Swientek, A. Bamberger, M. Köhli, M. Lupberger, U. Renz, M. Schumacher, Andreas Zwerger, A. Calderone, D. G. Cussans, H. F. Heath, S. Mandry, R. F. Page, J. J. Velthuis, D. Attié, D. Calvet, P. Colas, X. Coppolani, Y. Degerli, E. Delagnes , et al. (252 additional authors not shown)

    Abstract: The EUDET-project was launched to create an infrastructure for develo** and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infras… ▽ More

    Submitted 23 January, 2012; originally announced January 2012.

    Comments: 54 pages, 48 pictures

  9. arXiv:1111.5199  [pdf, other

    physics.ins-det

    Luminometer for the future International Linear Collider - simulation and beam test results

    Authors: J. A. Aguilar, S. Kulis, W. Wierba, L. Zawiejski, E. Kielar, M. Chrzaszcz, O. Novgorodova, H. Henschel, W. Lohmann, S. Schuwalow, K. Afanaciev, A. Ignatenko, S. Kollowa, I. Levy, M. Idzik, J. Kotula, A. Moszczynski, K. Oliwa, B. Pawlik, W. Daniluk

    Abstract: LumiCal will be the luminosity calorimeter for the proposed International Large Detector of the International Linear Collider (ILC). The ILC physics program requires the integrated luminosity to be measured with a relative precision on the order of 10e-3, or 10e-4 when running in GigaZ mode. Luminosity will be determined by counting Bhabha scattering events coincident in the two calorimeter module… ▽ More

    Submitted 22 November, 2011; originally announced November 2011.

    Comments: Technology and Instrumentation in Particle Physics 2011, Chicago, IL, USA. Presented June 11, 2011, and submitted to Physics Procedia

  10. Forward Instrumentation for ILC Detectors

    Authors: Halina Abramowicz, Angel Abusleme, Konstantin Afanaciev, Jonathan Aguilar, Prasoon Ambalathankandy, Philip Bambade, Matthias Bergholz, Ivanka Bozovic-Jelisavcic, Elena Castro, Georgy Chelkov, Cornelia Coca, Witold Daniluk, Angelo Dragone, Laurentiu Dumitru, Konrad Elsener, Igor Emeliantchik, Tomasz Fiutowski, Mikhail Gostkin, Christian Grah, Grzegorz Grzelak, Gunter Haller, Hans Henschel, Alexandr Ignatenko, Marek Idzik, Kazutoshi Ito , et al. (33 additional authors not shown)

    Abstract: Two special calorimeters are foreseen for the instrumentation of the very forward region of the ILC detector, a luminometer designed to measure the rate of low angle Bhabha scattering events with a precision better than 10-3 and a low polar angle calorimeter, adjacent to the beam-pipe. The latter will be hit by a large amount of beamstrahlung remnants. The amount and shape of these depositions wil… ▽ More

    Submitted 3 November, 2010; v1 submitted 13 September, 2010; originally announced September 2010.

    Comments: 30 pages, 28 figures

    Report number: DESY 10-142

    Journal ref: JINST 5:P12002,2010