-
Characterisation of the Intel RealSense D415 Stereo Depth Camera for Motion-Corrected CT Perfusion Imaging
Authors:
Mahdieh Dashtbani Moghari,
Philip Noonan,
David Henry,
Roger R Fulton,
Noel Young,
Krystal Moore,
Andrew Evanns,
Andre Kyme
Abstract:
Even for short protocols (<1 min), head movement can compromise accurate haemodynamic modelling of cerebral CT perfusion (CTP) imaging in acute stroke. Frame-to-frame registration is the most common form of retrospective correction but neglects the fact that motion is continuous, not discrete. By contrast, external tracking devices provide continuous motion monitoring and thereby the opportunity t…
▽ More
Even for short protocols (<1 min), head movement can compromise accurate haemodynamic modelling of cerebral CT perfusion (CTP) imaging in acute stroke. Frame-to-frame registration is the most common form of retrospective correction but neglects the fact that motion is continuous, not discrete. By contrast, external tracking devices provide continuous motion monitoring and thereby the opportunity to fully correct the acquired data for motion. The aim of this study was to characterise the Intel D415 stereo depth camera, a compact low-cost markerless tracking device, in terms of its suitability for retrospective CTP motion correction. The results showed that jitter was stable, and thermally-induced pose drift was {\le} 1.5 mm and {\le} 0.5° during the first 10-20 min, after which it also became stable. For static poses, the mean difference between the Intel D415 motion estimates and ground-truth poses for a head phantom was {\le} 1.24 \pm 0.01 mm and {\le} 0.68 \pm 0.01° for position and orientation, respectively. For dynamic poses measured while a head phantom travelled smooth continuous trajectories with median speed 0.031 ms^(-1) (speed range 0-0.500 ms^(-1)), the root-mean-square-error (RMSE) was {\le} 1.40 \pm 0.12 mm and {\le} 0.24 \pm 0.02°. When tracking a simulated patient head trajectory derived from a clinical CTP scan, the average RMSE was {\le} 0.86 \pm 0.03 mm and {\le} 0.16 \pm 0.03°. Tracking the head motion of a human volunteer inside a clinical CT scanner, the average RMSE was {\le} 2.72 \pm 0.24 mm and {\le} 0.55 \pm 0.07°. Overall, our results suggest that a single D415 tracking system can achieve promising pose estimation accuracy, though still worse than typical brain CT resolution, including CTP. The error is likely to be reduced to a practical level by combining multiple devices and this should be investigated in future work.
△ Less
Submitted 25 March, 2024;
originally announced March 2024.
-
Structure of Periodic Orbit Families in the Hill Restricted 4-Body Problem
Authors:
Gavin M. Brown,
Luke T. Peterson,
Damennick B. Henry,
Daniel J. Scheeres
Abstract:
The Hill Restricted 4-Body Problem (HR4BP) is a coherent time-periodic model that can be used to represent motion in the Sun-Earth-Moon (SEM) system. Periodic orbits were computed in this model to better understand the periodic orbit family structures that exist in these types of systems. First, periodic orbits in the Circular Restricted 3-Body Problem (CR3BP) representation of the Earth-Moon (EM)…
▽ More
The Hill Restricted 4-Body Problem (HR4BP) is a coherent time-periodic model that can be used to represent motion in the Sun-Earth-Moon (SEM) system. Periodic orbits were computed in this model to better understand the periodic orbit family structures that exist in these types of systems. First, periodic orbits in the Circular Restricted 3-Body Problem (CR3BP) representation of the Earth-Moon (EM) system were identified. A Melnikov-type function was used to identify a set of candidate points on the EM CR3BP periodic orbits to start a continuation algorithm. A pseudo-arclength continuation scheme was then used to obtain the corresponding periodic orbit families in the HR4BP when including the effect of the Sun. Bifurcation points were identified in the computed families to obtain additional orbit families.
△ Less
Submitted 29 February, 2024;
originally announced February 2024.
-
The Enhanced Resolution Imager and Spectrograph for the VLT
Authors:
R. Davies,
O. Absil,
G. Agapito,
A. Agudo Berbel,
A. Baruffolo,
V. Biliotti,
M. Bonaglia,
M. Bonse,
R. Briguglio,
P. Campana,
Y. Cao,
L. Carbonaro,
A. Cortes,
G. Cresci,
Y. Dallilar,
F. Dannert,
R. J. De Rosa,
M. Deysenroth,
I. Di Antonio,
A. Di Cianno,
G. Di Rico,
D. Doelman,
M. Dolci,
R. Dorn,
F. Eisenhauer
, et al. (59 additional authors not shown)
Abstract:
ERIS, the Enhanced Resolution Imager and Spectrograph, is an instrument that both extends and enhances the fundamental diffraction limited imaging and spectroscopy capability for the VLT. It replaces two instruments that were being maintained beyond their operational lifetimes, combines their functionality on a single focus, provides a new wavefront sensing module for natural and laser guide stars…
▽ More
ERIS, the Enhanced Resolution Imager and Spectrograph, is an instrument that both extends and enhances the fundamental diffraction limited imaging and spectroscopy capability for the VLT. It replaces two instruments that were being maintained beyond their operational lifetimes, combines their functionality on a single focus, provides a new wavefront sensing module for natural and laser guide stars that makes use of the Adaptive Optics Facility, and considerably improves on their performance. The observational modes ERIS provides are integral field spectroscopy at 1-2.5 μm, imaging at 1-5 μm with several options for high contrast imaging, and longslit spectroscopy at 3-4 μm, The instrument is installed at the Cassegrain focus of UT4 at the VLT and, following its commissioning during 2022, has been made available to the community.
△ Less
Submitted 26 April, 2023; v1 submitted 5 April, 2023;
originally announced April 2023.
-
Recovery of steady rotational wave profiles from pressure measurements at the bed
Authors:
Didier Clamond,
Joris Labarbe,
David Henry
Abstract:
We derive equations relating the pressure at a flat seabed and the free-surface profile for steady gravity waves with constant vorticity. The resulting set of nonlinear equations enables the recovery of the free surface from pressure measurements at the bed. Furthermore, the flow vorticity is determined solely from the bottom pressure as part of the recovery method. This approach is applicable eve…
▽ More
We derive equations relating the pressure at a flat seabed and the free-surface profile for steady gravity waves with constant vorticity. The resulting set of nonlinear equations enables the recovery of the free surface from pressure measurements at the bed. Furthermore, the flow vorticity is determined solely from the bottom pressure as part of the recovery method. This approach is applicable even in the presence of stagnation points and its efficiency is illustrated via numerical examples.
△ Less
Submitted 16 February, 2023;
originally announced February 2023.
-
HiPERCAM: a quintuple-beam, high-speed optical imager on the 10.4-m Gran Telescopio Canarias
Authors:
V. S. Dhillon,
N. Bezawada,
M. Black,
S. D. Dixon,
T. Gamble,
X. Gao,
D. M. Henry,
P. Kerry,
S. P. Littlefair,
D. W. Lunney,
T. R. Marsh,
C. Miller,
S. G. Parsons,
R. P. Ashley,
E. Breedt,
A. Brown,
M. J. Dyer,
M. J. Green,
I. Pelisoli,
D. I. Sahman,
J. Wild,
D. J. Ives,
L. Mehrgan,
J. Stegmeier,
C. M. Dubbeldam
, et al. (14 additional authors not shown)
Abstract:
HiPERCAM is a portable, quintuple-beam optical imager that saw first light on the 10.4-m Gran Telescopio Canarias (GTC) in 2018. The instrument uses re-imaging optics and 4 dichroic beamsplitters to record $u_s g_s r_s i_s z_s$ ($320-1060$ nm) images simultaneously on its five CCD cameras, each of 3.1 arcmin (diagonal) field of view. The detectors in HiPERCAM are frame-transfer devices cooled ther…
▽ More
HiPERCAM is a portable, quintuple-beam optical imager that saw first light on the 10.4-m Gran Telescopio Canarias (GTC) in 2018. The instrument uses re-imaging optics and 4 dichroic beamsplitters to record $u_s g_s r_s i_s z_s$ ($320-1060$ nm) images simultaneously on its five CCD cameras, each of 3.1 arcmin (diagonal) field of view. The detectors in HiPERCAM are frame-transfer devices cooled thermo-electrically to 183 K, thereby allowing both long-exposure, deep imaging of faint targets, as well as high-speed (over 1000 windowed frames per second) imaging of rapidly varying targets. A comparison-star pick-off system in the telescope focal plane increases the effective field of view to 6.7 arcmin for differential photometry. Combining HiPERCAM with the world's largest optical telescope enables the detection of astronomical sources to $g_s \sim 23$ in 1 s and $g_s \sim 28$ in 1 h. In this paper we describe the scientific motivation behind HiPERCAM, present its design, report on its measured performance, and outline some planned enhancements.
△ Less
Submitted 21 July, 2021;
originally announced July 2021.
-
Extreme water wave profile recovery from pressure measurements at the seabed
Authors:
Didier Clamond,
David Henry
Abstract:
The aim of this note is to examine the efficacy of a recently developed approach to the recovery of nonlinear water waves from pressure measurements at the seabed, by applying it to the celebrated extreme Stokes wave.
The aim of this note is to examine the efficacy of a recently developed approach to the recovery of nonlinear water waves from pressure measurements at the seabed, by applying it to the celebrated extreme Stokes wave.
△ Less
Submitted 29 May, 2020;
originally announced May 2020.
-
ERIS: revitalising an adaptive optics instrument for the VLT
Authors:
Richard Davies,
Simone Esposito,
Hans Martin Schmid,
William Taylor,
Guido Agapito,
Alexander Agudo Berbel,
Andrea Baruffolo,
Valdemaro Biliotti,
Beth Biller,
Martin Black,
Anna Boehle,
Runa Briguglio,
Alexander Buron,
Luca Carbonaro,
Angela Cortes,
Giovanni Cresci,
Matthias Deysenroth,
Amico Di Cianno,
Gianluca Di Rico,
David Doelman,
Mauro Dolci,
Reinhold Dorn,
Frank Eisenhauer,
Daniela Fantinel,
Debora Ferruzzi
, et al. (41 additional authors not shown)
Abstract:
ERIS is an instrument that will both extend and enhance the fundamental diffraction limited imaging and spectroscopy capability for the VLT. It will replace two instruments that are now being maintained beyond their operational lifetimes, combine their functionality on a single focus, provide a new wavefront sensing module that makes use of the facility Adaptive Optics System, and considerably imp…
▽ More
ERIS is an instrument that will both extend and enhance the fundamental diffraction limited imaging and spectroscopy capability for the VLT. It will replace two instruments that are now being maintained beyond their operational lifetimes, combine their functionality on a single focus, provide a new wavefront sensing module that makes use of the facility Adaptive Optics System, and considerably improve their performance. The instrument will be competitive with respect to JWST in several regimes, and has outstanding potential for studies of the Galactic Center, exoplanets, and high redshift galaxies. ERIS had its final design review in 2017, and is expected to be on sky in 2020. This contribution describes the instrument concept, outlines its expected performance, and highlights where it will most excel.
△ Less
Submitted 13 July, 2018;
originally announced July 2018.
-
Curved detectors developments and characterization: application to astronomical instruments
Authors:
Simona Lombardo,
Thibault Behaghel,
Bertrand Chambion,
Wilfried Jahn,
Emmanuel Hugot,
Eduard Muslimov,
Melanie Roulet,
Marc Ferrari,
Christophe Gaschet,
Stéphane Caplet,
David Henry
Abstract:
Many astronomical optical systems have the disadvantage of generating curved focal planes requiring flattening optical elements to project the corrected image on flat detectors. The use of these designs in combination with a classical flat sensor implies an overall degradation of throughput and system performances to obtain the proper corrected image. With the recent development of curved sensor t…
▽ More
Many astronomical optical systems have the disadvantage of generating curved focal planes requiring flattening optical elements to project the corrected image on flat detectors. The use of these designs in combination with a classical flat sensor implies an overall degradation of throughput and system performances to obtain the proper corrected image. With the recent development of curved sensor this can be avoided. This new technology has been gathering more and more attention from a very broad community, as the potential applications are multiple: from low-cost commercial to high impact scientific systems, to mass-market and on board cameras, defense and security, and astronomical community. We describe here the first concave curved CMOS detector developed within a collaboration between CNRS- LAM and CEA-LETI. This fully-functional detector 20 Mpix (CMOSIS CMV20000) has been curved down to a radius of Rc = 150 mm over a size of 24x32 mm^2 . We present here the methodology adopted for its characterization and describe in detail all the results obtained. We also discuss the main components of noise, such as the readout noise, the fixed pattern noise and the dark current. Finally we provide a comparison with the flat version of the same sensor in order to establish the impact of the curving process on the main characteristics of the sensor.
△ Less
Submitted 5 July, 2018;
originally announced July 2018.
-
Transport Measurements of Surface Electrons in 200 nm Deep Helium-Filled Microchannels Above Amorphous Metallic Electrodes
Authors:
A. T. Asfaw,
E. I. Kleinbaum,
M. D. Henry,
E. A. Shaner,
S. A. Lyon
Abstract:
We report transport measurements of electrons on helium in a microchannel device where the channels are 200 nm deep and 3 $μ$m wide. The channels are fabricated above amorphous metallic Ta$_{40}$W$_{40}$Si$_{20}$, which has surface roughness below 1 nm and minimal variations in work function across the surface due to the absence of polycrystalline grains. We are able to set the electron density in…
▽ More
We report transport measurements of electrons on helium in a microchannel device where the channels are 200 nm deep and 3 $μ$m wide. The channels are fabricated above amorphous metallic Ta$_{40}$W$_{40}$Si$_{20}$, which has surface roughness below 1 nm and minimal variations in work function across the surface due to the absence of polycrystalline grains. We are able to set the electron density in the channels using a ground plane. We estimate a mobility of 300 cm$^2$/V$\cdot$s and electron densities as high as 2.56$\times$10$^9$ cm$^{-2}$. We demonstrate control of the transport using a barrier which enables pinchoff at a central microchannel connecting two reservoirs. The conductance through the central microchannel is measured to be 10 nS for an electron density of 1.58$\times$10$^9$ cm$^{-2}$. Our work extends transport measurements of surface electrons to thin helium films in microchannel devices above metallic substrates.
△ Less
Submitted 24 December, 2018; v1 submitted 2 July, 2018;
originally announced July 2018.
-
First light with HiPERCAM on the GTC
Authors:
Vikram Dhillon,
Simon Dixon,
Trevor Gamble,
Paul Kerry,
Stuart Littlefair,
Steven Parsons,
Thomas Marsh,
Naidu Bezawada,
Martin Black,
Xiaofeng Gao,
David Henry,
David Lunney,
Christopher Miller,
Marc Dubbeldam,
Timothy Morris,
James Osborn,
Richard Wilson,
Jorge Casares,
Teo Munoz-Darias,
Enric Palle,
Pablo Rodriguez-Gil,
Tariq Shahbaz,
Antonio de Ugarte Postigo
Abstract:
HiPERCAM is a quintuple-beam imager that saw first light on the 4.2m William Herschel Telescope (WHT) in October 2017 and on the 10.4m Gran Telescopio Canarias (GTC) in February 2018. The instrument uses re-imaging optics and 4 dichroic beamsplitters to record ugriz (300-1000nm) images simultaneously on its five CCD cameras. The detectors in HiPERCAM are frame-transfer devices cooled thermo-electr…
▽ More
HiPERCAM is a quintuple-beam imager that saw first light on the 4.2m William Herschel Telescope (WHT) in October 2017 and on the 10.4m Gran Telescopio Canarias (GTC) in February 2018. The instrument uses re-imaging optics and 4 dichroic beamsplitters to record ugriz (300-1000nm) images simultaneously on its five CCD cameras. The detectors in HiPERCAM are frame-transfer devices cooled thermo-electrically to -90degC, thereby allowing both long-exposure, deep imaging of faint targets, as well as high-speed (over 1000 windowed frames per second) imaging of rapidly varying targets. In this paper, we report on the as-built design of HiPERCAM, its first-light performance on the GTC, and some of the planned future enhancements.
△ Less
Submitted 2 July, 2018;
originally announced July 2018.
-
Transition to chaos in an acoustically-driven cavity flow
Authors:
Gaby Launay,
Tristan Cambonie,
Daniel Henry,
Alban Pothérat,
Valéry Botton
Abstract:
We consider the unsteady regimes of an acoustically-driven jet that forces a recirculating flow through successive reflections on the walls of a square cavity. The specific question being addressed is to know whether the system can sustain states of low-dimensional chaos when the acoustic intensity driving the jet is increased, and, if so, to characterise the pathway and underlying physical mechan…
▽ More
We consider the unsteady regimes of an acoustically-driven jet that forces a recirculating flow through successive reflections on the walls of a square cavity. The specific question being addressed is to know whether the system can sustain states of low-dimensional chaos when the acoustic intensity driving the jet is increased, and, if so, to characterise the pathway and underlying physical mechanisms. We adopt two complementary approaches, both based on data extracted from numerical simulations: (i) We first characterise successive bifurcations through the analysis of leading frequencies. Two successive phases in the evolution of the system are singled out in this way, both leading to potentially chaotic states. The two phases are separated by a drastic simplification of the dynamics that immediately follows the emergence of intermittency. The second phase also features a second intermediate state where the dynamics is simplified due to frequency-locking. (ii) Nonlinear time series analysis enables us to reconstruct the attractor of the underlying dynamical system, and to calculate its correlation dimension and leading Lyapunov exponent. Both these quantities bring confirmation that the state preceding the dynamic simplification that initiates the second phase is chaotic. Poincaré maps further reveal that this chaotic state in fact results from a dynamic instability of the system between two non-chaotic states respectively observed at slightly lower and slightly higher acoustic forcing.
△ Less
Submitted 25 March, 2019; v1 submitted 24 June, 2018;
originally announced June 2018.
-
Curved detectors for wide field imaging systems: impact on tolerance analysis
Authors:
Eduard Muslimov,
Emmanuel Hugot,
Simona Lombardo,
Melanie Roulet,
Thibault Behaghel,
Marc Ferrari,
Wilfried Jahn,
Christophe Gaschet,
Bertrand Chambion,
David Henry
Abstract:
In the present paper we consider quantitative estimation of the tolerances widening in optical systems with curved detectors. The gain in image quality allows to loosen the margins for manufacturing and assembling errors. On another hand, the requirements for the detector shape and positioning become more tight. We demonstrate both of the effects on example of two optical designs. The first one is…
▽ More
In the present paper we consider quantitative estimation of the tolerances widening in optical systems with curved detectors. The gain in image quality allows to loosen the margins for manufacturing and assembling errors. On another hand, the requirements for the detector shape and positioning become more tight. We demonstrate both of the effects on example of two optical designs. The first one is a rotationally-symmetrical lens with focal length of 25 mm, f-ratio of 3.5 and field of view equal to 72$^\circ$, working in the visible domain. The second design is a three-mirror anastigmat telescope with focal length of 250 mm, f-ratio of 2.0 and field of view equal to $4^\circ \times 4^\circ$. In both of the cases use of curved detectors allow to increase the image quality and substantially decrease the requirements for manufacturing precision
△ Less
Submitted 23 May, 2018;
originally announced May 2018.
-
Accelerated vortex dynamics across the magnetic 3D-to-2D crossover in disordered superconductors
Authors:
Serena Eley,
Roland Willa,
Masashi Miura,
Michio Sato,
Maxime Leroux,
Michael David Henry,
Leonardo Civale
Abstract:
Disorder can have remarkably disparate consequences in superconductors, driving superconductor-insulator transitions in ultrathin films by localizing electron pairs and boosting the supercurrent carrying capacity of thick films by localizing vortices (magnetic flux lines). Though the electronic 3D-to-2D crossover at material thicknesses $d \sim ξ$ (coherence length) is well studied, a similarly co…
▽ More
Disorder can have remarkably disparate consequences in superconductors, driving superconductor-insulator transitions in ultrathin films by localizing electron pairs and boosting the supercurrent carrying capacity of thick films by localizing vortices (magnetic flux lines). Though the electronic 3D-to-2D crossover at material thicknesses $d \sim ξ$ (coherence length) is well studied, a similarly consequential magnetic crossover at $d \sim L_c$ (pinning length) that should drastically alter material properties remains largely underexamined. According to collective pinning theory, vortex segments of length $L_c$ bend to adjust to energy wells provided by point defects. Consequently, if $d$ truncates $L_c$, a change from elastic to rigid vortex dynamics should increase the rate of thermally activated vortex motion $S$. Here, we characterize the dependence of $S$ on sample thickness in Nb and cuprate films. The results for Nb are consistent with collective pinning theory, whereas creep in the cuprate is strongly influenced by sparse large precipitates. We leverage the sensitivity of $S$ to $d$ to determine the generally unknown scale $L_c$, establishing a new route for extracting pinning lengths in heterogeneously disordered materials.
△ Less
Submitted 18 August, 2018; v1 submitted 8 September, 2017;
originally announced September 2017.
-
Combining freeform optics and curved detectors for wide field imaging: a polynomial approach over squared aperture
Authors:
Eduard Muslimov,
Emmanuel Hugot,
Wilfried Jahn,
Sebastien Vives,
Marc Ferrari,
Bertrand Chambion,
David Henry,
Cristophe Gaschet
Abstract:
In the recent years a significant progress was achieved in the field of design and fabrication of optical systems based on freeform optical surfaces. They provide a possibility to build fast, wide-angle and high-resolution systems, which are very compact and free of obscuration. However, the field of freeform surfaces design techniques still remains underexplored. In the present paper we use the m…
▽ More
In the recent years a significant progress was achieved in the field of design and fabrication of optical systems based on freeform optical surfaces. They provide a possibility to build fast, wide-angle and high-resolution systems, which are very compact and free of obscuration. However, the field of freeform surfaces design techniques still remains underexplored. In the present paper we use the mathematical apparatus of orthogonal polynomials defined over a square aperture, which was developed before for the tasks of wavefront reconstruction, to describe shape of a mirror surface. Two cases, namely Legendre polynomials and generalization of the Zernike polynomials on a square, are considered. The potential advantages of these polynomials sets are demonstrated on example of a three-mirror unobscured telescope with F/#=2.5 and FoV=7.2x7.2°. In addition, we discuss possibility of use of curved detectors in such a design.
△ Less
Submitted 17 June, 2017;
originally announced June 2017.
-
Wave-front error breakdown in LGS MOAO validated on-sky by CANARY
Authors:
O. A. Martin,
É. Gendron.,
G. Rousset,
D. Gratadour,
F. Vidal,
T. J. Morris,
A. G. Basden,
R. M. Myers,
C. M. Correia,
D. Henry
Abstract:
CANARY is the multi-object adaptive optics (MOAO) on-sky pathfinder developed in the perspective of Multi-Object Spectrograph on Extremely Large Telescopes~(ELTs). In 2013, CANARY was operated on-sky at the William Herschel telescope~(WHT), using three off-axis natural guide stars~(NGS) and four off-axis Rayleigh laser guide stars~(LGS), in open-loop, with the on-axis compensated turbulence observ…
▽ More
CANARY is the multi-object adaptive optics (MOAO) on-sky pathfinder developed in the perspective of Multi-Object Spectrograph on Extremely Large Telescopes~(ELTs). In 2013, CANARY was operated on-sky at the William Herschel telescope~(WHT), using three off-axis natural guide stars~(NGS) and four off-axis Rayleigh laser guide stars~(LGS), in open-loop, with the on-axis compensated turbulence observed with a H-band imaging camera and a Truth wave-front sensor~(TS) for diagnostic purposes. Our purpose is to establish a reliable and accurate wave-front error breakdown for LGS MOAO. This will enable a comprehensive analysis of \cana on-sky results and provide tools for validating simulations of MOAO systems for ELTs. To evaluate the MOAO performance, we compared the CANARY on-sky results running in MOAO, in Single Conjugated Adaptive Optics~(SCAO) and in Ground Layer Adaptive Optics~(GLAO) modes, over a large set of data acquired in 2013. We provide a statistical study of the seeing. We also evaluated the wave-front error breakdown from both analytic computations, one based on a MOAO system modelling and the other on the measurements from the CANARY TS. We have focussed especially on the tomographic error and we detail its vertical error decomposition~(VED). We show that CANARY obtained 30.1\%, 21.4\% and 17.1\% H-band Strehl ratios in SCAO, MOAO and GLAO respectively, for median seeing conditions with 0.66" of total seeing including 0.59" at the ground. Moreover, we get 99\% of correlation over 4,500 samples, for any AO modes, between two analytic computations of residual phase variance. Based on these variances, we obtain a reasonable Strehl-ratio~(SR) estimation when compared to the measured IR image SR. We evaluate the gain in compensation for the altitude turbulence brought by MOAO when compared to GLAO.
△ Less
Submitted 20 October, 2016; v1 submitted 15 October, 2016;
originally announced October 2016.
-
Flexible focal plane arrays for UVOIR wide field instrumentation
Authors:
Emmanuel Hugot,
Wilfried Jahn,
Bertrand Chambion,
Gaid Moulin,
Liubov Nikitushkina,
Christophe Gaschet,
David Henry,
Stéphane Getin,
Marc Ferrari,
Yann Gaeremynck
Abstract:
LAM and CEA-LETI are develo** the technology of deformable detectors, for UV, VIS or NIR applications. Such breakthrough devices will be a revolution for future wide field imagers and spectrographs, firstly by improving the image quality with better off-axis sharpness, resolution, brightness while scaling down the optical system, secondly by overcoming the manufacturing issues identified so far…
▽ More
LAM and CEA-LETI are develo** the technology of deformable detectors, for UV, VIS or NIR applications. Such breakthrough devices will be a revolution for future wide field imagers and spectrographs, firstly by improving the image quality with better off-axis sharpness, resolution, brightness while scaling down the optical system, secondly by overcoming the manufacturing issues identified so far and by offering a flexibility and versatility in optical design. The technology of curved detectors can benefit of the developments of active and deformable structures, to provide a flexibility and a fine tuning of the detectors curvature by thinning down the substrate without modifying the fabrication process of the active pixels. We present studies done so far on optical design improvements, the technological demonstrators we developed and their performances as well as the future five-years roadmap for these developments.
△ Less
Submitted 21 July, 2016;
originally announced July 2016.
-
HiPERCAM: A high-speed, quintuple-beam CCD camera for the study of rapid variability in the Universe
Authors:
V. S. Dhillon,
T. R. Marsh,
N. Bezawada,
M. Black,
S. Dixon,
T. Gamble,
D. Henry,
P. Kerry,
S. P. Littlefair,
D. W. Lunney,
T. Morris,
J. Osborn,
R. W. Wilson
Abstract:
HiPERCAM is a high-speed camera for the study of rapid variability in the Universe. The project is funded by a 3.5MEuro European Research Council Advanced Grant. HiPERCAM builds on the success of our previous instrument, ULTRACAM, with very significant improvements in performance thanks to the use of the latest technologies. HiPERCAM will use 4 dichroic beamsplitters to image simultaneously in 5 o…
▽ More
HiPERCAM is a high-speed camera for the study of rapid variability in the Universe. The project is funded by a 3.5MEuro European Research Council Advanced Grant. HiPERCAM builds on the success of our previous instrument, ULTRACAM, with very significant improvements in performance thanks to the use of the latest technologies. HiPERCAM will use 4 dichroic beamsplitters to image simultaneously in 5 optical channels covering the u'g'r'i'z' bands. Frame rates of over 1000 per second will be achievable using an ESO CCD controller (NGC), with every frame GPS timestamped. The detectors are custom-made, frame-transfer CCDs from e2v, with 4 low-noise (2.5e-) outputs, mounted in small thermoelectrically-cooled heads operated at 180 K, resulting in virtually no dark current. The two reddest CCDs will be deep-depletion devices with anti-etaloning, providing high quantum efficiencies across the red part of the spectrum with no fringing. The instrument will also incorporate scintillation noise correction via the conjugate-plane photometry technique. The opto-mechanical chassis will make use of additive manufacturing techniques in metal to make a light-weight, rigid and temperature-invariant structure. First light is expected on the 4.2m William Herschel Telescope on La Palma in 2017 (on which the field of view will be 10' with a 0.3"/pixel scale), with subsequent use planned on the 10.4m Gran Telescopio Canarias on La Palma (on which the field of view will be 4' with a 0.11"/pixel scale) and the 3.5m New Technology Telescope in Chile.
△ Less
Submitted 29 June, 2016;
originally announced June 2016.
-
Experience with wavefront sensor and deformable mirror interfaces for wide-field adaptive optics systems
Authors:
A. G. Basden,
D. Atkinson,
N. A. Bharmal,
U. Bitenc,
M. Brangier,
T. Buey,
T. Butterley,
D. Cano,
F. Chemla,
P. Clark,
M. Cohen,
J. -M. Conan,
F. J. de Cos,
C. Dickson,
N. A. Dipper,
C. N. Dunlop,
P. Feautrier,
T. Fusco,
J. L. Gach,
E. Gendron,
D. Geng,
S. J. Goodsell,
D. Gratadour,
A. H. Greenaway,
A. Guesalaga
, et al. (34 additional authors not shown)
Abstract:
Recent advances in adaptive optics (AO) have led to the implementation of wide field-of-view AO systems. A number of wide-field AO systems are also planned for the forthcoming Extremely Large Telescopes. Such systems have multiple wavefront sensors of different types, and usually multiple deformable mirrors (DMs).
Here, we report on our experience integrating cameras and DMs with the real-time c…
▽ More
Recent advances in adaptive optics (AO) have led to the implementation of wide field-of-view AO systems. A number of wide-field AO systems are also planned for the forthcoming Extremely Large Telescopes. Such systems have multiple wavefront sensors of different types, and usually multiple deformable mirrors (DMs).
Here, we report on our experience integrating cameras and DMs with the real-time control systems of two wide-field AO systems. These are CANARY, which has been operating on-sky since 2010, and DRAGON, which is a laboratory adaptive optics real-time demonstrator instrument. We detail the issues and difficulties that arose, along with the solutions we developed. We also provide recommendations for consideration when develo** future wide-field AO systems.
△ Less
Submitted 24 March, 2016;
originally announced March 2016.
-
The Visible and Infrared Survey Telescope for Astronomy (VISTA): Design, Technical Overview and Performance
Authors:
Will Sutherland,
Jim Emerson,
Gavin Dalton,
Eli Atad-Ettedgui,
Steven Beard,
Richard Bennett,
Naidu Bezawada,
Andrew Born,
Martin Caldwell,
Paul Clark,
Simon Craig,
David Henry,
Paul Jeffers,
Bryan Little,
Alistair McPherson,
John Murray,
Malcolm Stewart,
Brian Stobie,
David Terrett,
Kim Ward,
Martin Whalley,
Guy Woodhouse
Abstract:
The Visible and Infrared Survey Telescope for Astronomy (VISTA) is the 4-metre wide-field survey telescope at ESO's Paranal Observatory, equipped with the world's largest near-infrared imaging camera (VISTA IR Camera, VIRCAM), with 1.65 degree diameter field of view, and 67 Mpixels giving 0.6 square degrees active pixel area, operating at wavelengths 0.8 - 2.3 microns. We provide a short history o…
▽ More
The Visible and Infrared Survey Telescope for Astronomy (VISTA) is the 4-metre wide-field survey telescope at ESO's Paranal Observatory, equipped with the world's largest near-infrared imaging camera (VISTA IR Camera, VIRCAM), with 1.65 degree diameter field of view, and 67 Mpixels giving 0.6 square degrees active pixel area, operating at wavelengths 0.8 - 2.3 microns. We provide a short history of the project, and an overview of the technical details of the full system including the optical design, mirrors, telescope structure, IR camera, active optics, enclosure and software. The system includes several innovative design features such as the f/1 primary mirror, the dichroic cold-baffle camera design and the sophisticated wavefront sensing system delivering closed-loop 5-axis alignment of the secondary mirror. We conclude with a summary of the delivered performance, and a short overview of the six ESO public surveys in progress on VISTA.
△ Less
Submitted 11 March, 2015; v1 submitted 16 September, 2014;
originally announced September 2014.
-
Analysis of on-sky MOAO performance of CANARY using natural guide stars
Authors:
Fabrice Vidal,
Eric Gendron,
Gerard Rousset,
Tim Morris,
Alastair Basden,
Richard Myers,
Matthieu Brangier,
Fanny Chemla,
Nigel Dipper,
Damien Gratadour,
David Henry,
Zoltan Hubert,
Andy Longmore,
Olivier Martin,
Gordon Talbot,
Eddy Younger
Abstract:
The first on-sky results obtained by CANARY, the Multi-Object Adaptive Optics (MOAO) demonstrator, are analysed. The data were recorded at the William Herschel Telescope, at the end of September 2010. We describe the command and calibrations algorithms used during the run and present the observing conditions. The processed data are MOAO-loop engaged or disengaged slope buffers, comprising the sync…
▽ More
The first on-sky results obtained by CANARY, the Multi-Object Adaptive Optics (MOAO) demonstrator, are analysed. The data were recorded at the William Herschel Telescope, at the end of September 2010. We describe the command and calibrations algorithms used during the run and present the observing conditions. The processed data are MOAO-loop engaged or disengaged slope buffers, comprising the synchronised measurements of the four Natural Guide Stars (NGS) wavefront sensors running in parallel, and near Infra-Red (IR) images. We describe the method we use to establish the error budget of CANARY. We are able to evaluate the to- mographic and the open loop errors, having median values around 216 nm and 110 nm respectively. In addition, we identify an unexpected residual quasi-static field aberration term of mean value 110 nm. We present the detailed error budget analysed for three sets of data for three different asterisms. We compare the experimental budgets with the numerically simulated ones and demonstrate a good agreement. We find also a good agreement between the computed error budget from the slope buffers and the measured Strehl ratio on the IR images, ranging between 10% and 20% at 1 530 nm. These results make us confident in our ability to establish the error budget of future MOAO instruments.
△ Less
Submitted 23 June, 2014;
originally announced June 2014.
-
Two-component equations modelling water waves with constant vorticity
Authors:
Joachim Escher,
David Henry,
Boris Kolev,
Tony Lyons
Abstract:
In this paper we derive a two-component system of nonlinear equations which model two-dimensional shallow water waves with constant vorticity. Then we prove well-posedness of this equation using a geometrical framework which allows us to recast this equation as a geodesic flow on an infinite dimensional manifold. Finally, we provide a criteria for global existence.
In this paper we derive a two-component system of nonlinear equations which model two-dimensional shallow water waves with constant vorticity. Then we prove well-posedness of this equation using a geometrical framework which allows us to recast this equation as a geodesic flow on an infinite dimensional manifold. Finally, we provide a criteria for global existence.
△ Less
Submitted 30 September, 2014; v1 submitted 6 June, 2014;
originally announced June 2014.
-
Instability of equatorial water waves with an underlying current
Authors:
François Genoud,
David Henry
Abstract:
In this paper we use the short-wavelength instability approach to derive an instability threshold for exact trapped equatorial waves propagating eastwards in the presence of an underlying current.
In this paper we use the short-wavelength instability approach to derive an instability threshold for exact trapped equatorial waves propagating eastwards in the presence of an underlying current.
△ Less
Submitted 9 April, 2014; v1 submitted 7 March, 2014;
originally announced March 2014.
-
One-dimensional weakly nonlinear model equations for Rossby waves
Authors:
David Henry,
Rossen Ivanov
Abstract:
In this study we explore several possibilities for modelling weakly nonlinear Rossby waves in fluid of constant depth, which propagate predominantly in one direction. The model equations obtained include the BBM equation, as well as the integrable KdV and Degasperis-Procesi equations.
In this study we explore several possibilities for modelling weakly nonlinear Rossby waves in fluid of constant depth, which propagate predominantly in one direction. The model equations obtained include the BBM equation, as well as the integrable KdV and Degasperis-Procesi equations.
△ Less
Submitted 3 February, 2014;
originally announced February 2014.
-
On the persistence properties of the cross-coupled Camassa-Holm system
Authors:
David Henry,
Darryl D. Holm,
Rossen I. Ivanov
Abstract:
In this paper we examine the evolution of solutions, that initially have compact support, of a recently-derived system of cross-coupled Camassa-Holm equations. The analytical methods which we employ provide a full picture for the persistence of compact support for the momenta. For solutions of the system itself, the answer is more convoluted, and we determine when the compactness of the support is…
▽ More
In this paper we examine the evolution of solutions, that initially have compact support, of a recently-derived system of cross-coupled Camassa-Holm equations. The analytical methods which we employ provide a full picture for the persistence of compact support for the momenta. For solutions of the system itself, the answer is more convoluted, and we determine when the compactness of the support is lost, replaced instead by an exponential decay rate.
△ Less
Submitted 8 November, 2013;
originally announced November 2013.
-
On the existence of steady periodic capillary-gravity stratified water waves
Authors:
David Henry,
Bogdan-Vasile Matioc
Abstract:
We prove the existence of small steady periodic capillary-gravity water waves for general stratified flows, where we allow for stagnation points in the flow. We establish the existence of both laminar and non-laminar flow solutions for the governing equations. This is achieved by using bifurcation theory and estimates based on the ellipticity of the system, where we regard, in turn, the mass-flux…
▽ More
We prove the existence of small steady periodic capillary-gravity water waves for general stratified flows, where we allow for stagnation points in the flow. We establish the existence of both laminar and non-laminar flow solutions for the governing equations. This is achieved by using bifurcation theory and estimates based on the ellipticity of the system, where we regard, in turn, the mass-flux and surface tension as bifurcation parameters.
△ Less
Submitted 24 May, 2013;
originally announced May 2013.
-
Space-quality data from balloon-borne telescopes: the High Altitude Lensing Observatory (HALO)
Authors:
Jason Rhodes,
Benjamin Dobke,
Jeffrey Booth,
Richard Massey,
Kurt Liewer,
Roger Smith,
Adam Amara,
Jack Aldrich,
Joel Berge,
Naidu Bezawada,
Paul Brugarolas,
Paul Clark,
Cornelis M. Dubbeldam,
Richard Ellis,
Carlos Frenk,
Angus Gallie,
Alan Heavens,
David Henry,
Eric Jullo,
Thomas Kitching,
James Lanzi,
Simon Lilly,
David Lunney,
Satoshi Miyazaki,
David Morris
, et al. (14 additional authors not shown)
Abstract:
We present a method for attaining sub-arcsecond pointing stability during sub- orbital balloon flights, as designed for in the High Altitude Lensing Observatory (HALO) concept. The pointing method presented here has the potential to perform near-space quality optical astronomical imaging at 1-2% of the cost of space-based missions. We also discuss an architecture that can achieve sufficient thermo…
▽ More
We present a method for attaining sub-arcsecond pointing stability during sub- orbital balloon flights, as designed for in the High Altitude Lensing Observatory (HALO) concept. The pointing method presented here has the potential to perform near-space quality optical astronomical imaging at 1-2% of the cost of space-based missions. We also discuss an architecture that can achieve sufficient thermomechanical stability to match the pointing stability. This concept is motivated by advances in the development and testing of Ultra Long Duration Balloon (ULDB) flights which promise to allow observation campaigns lasting more than three months. The design incorporates a multi-stage pointing architecture comprising: a gondola coarse azimuth control system, a multi-axis nested gimbal frame structure with arcsecond stability, a telescope de-rotator to eliminate field rotation, and a fine guidance stage consisting of both a telescope mounted angular rate sensor and guide CCDs in the focal plane to drive a fast-steering mirror. We discuss the results of pointing tests together with a preliminary thermo-mechanical analysis required for sub-arcsecond pointing at high altitude. Possible future applications in the areas of wide-field surveys and exoplanet searches are also discussed.
△ Less
Submitted 14 May, 2012;
originally announced May 2012.
-
Surface Encapsulation for Low-Loss Silicon Photonics
Authors:
M. Borselli,
T. J. Johnson,
C. P. Michael,
M. D. Henry,
Oskar Painter
Abstract:
Encapsulation layers are explored for passivating the surfaces of silicon to reduce optical absorption in the 1500-nm wavelength band. Surface-sensitive test structures consisting of microdisk resonators are fabricated for this purpose. Based on previous work in silicon photovoltaics, coatings of SiNx and SiO2 are applied under varying deposition and annealing conditions. A short dry thermal oxi…
▽ More
Encapsulation layers are explored for passivating the surfaces of silicon to reduce optical absorption in the 1500-nm wavelength band. Surface-sensitive test structures consisting of microdisk resonators are fabricated for this purpose. Based on previous work in silicon photovoltaics, coatings of SiNx and SiO2 are applied under varying deposition and annealing conditions. A short dry thermal oxidation followed by a long high-temperature N2 anneal is found to be most effective at long-term encapsulation and reduction of interface absorption. Minimization of the optical loss is attributed to simultaneous reduction in sub-bandgap silicon surface states and hydrogen in the cap** material.
△ Less
Submitted 3 July, 2007;
originally announced July 2007.
-
Sur la laminarite de certains courants
Authors:
De Thelin Henry
Abstract:
We show that a sequence of smooth analytic curves of the unit ball of the complex plane, for which the genus is bounded by the area, converges to a lamination in a weak sense.
We show that a sequence of smooth analytic curves of the unit ball of the complex plane, for which the genus is bounded by the area, converges to a lamination in a weak sense.
△ Less
Submitted 31 October, 2002;
originally announced October 2002.
-
Gutzwiller-Jastrow Wavefunctions for the $1/r$ Hubbard Model
Authors:
D. F. Wang Joseph Henry,
Q. F. Zhong,
P. Coleman Serin
Abstract:
In this work, we study the wavefunctions of the one dimensional $1/r$ Hubbard model in the strong interaction limit $U =\infty$. A set of Gutzwiller-Jastorw wavefunctions are shown to be eigen-functions of the Hamiltonian. The entire excitation spectrum and the thermodynamics are also studied in terms of more generalized Jastrow wavefunctions. For the wavefunctions and integrability conditions a…
▽ More
In this work, we study the wavefunctions of the one dimensional $1/r$ Hubbard model in the strong interaction limit $U =\infty$. A set of Gutzwiller-Jastorw wavefunctions are shown to be eigen-functions of the Hamiltonian. The entire excitation spectrum and the thermodynamics are also studied in terms of more generalized Jastrow wavefunctions. For the wavefunctions and integrability conditions at finite on-site energy, further investigations are needed.
△ Less
Submitted 30 May, 1993; v1 submitted 29 May, 1993;
originally announced May 1993.