-
Measurement of the charged pion mass using a low-density target of light atoms
Authors:
M Trassinelli,
D. F. Anagnostopoulos,
G Borchert,
A Dax,
J. -P Egger,
D Gotta,
M Hennebach,
P Indelicato,
Y. -W Liu,
B Manil,
N Nelms,
L. M. Simons,
A Wells
Abstract:
We present a new evaluation of the negatively charged pion mass based on the simultaneous spec-troscopy of pionic nitrogen and muonic oxygen transitions using a gaseous target composed by a N 2 /O 2 mixture at 1.4 bar. We present the experimental setup and the methods for deriving the pion mass value from the spatial separation from the 5g -- 4 f $π$N transition line and the 5g -- 4 f $μ$O transit…
▽ More
We present a new evaluation of the negatively charged pion mass based on the simultaneous spec-troscopy of pionic nitrogen and muonic oxygen transitions using a gaseous target composed by a N 2 /O 2 mixture at 1.4 bar. We present the experimental setup and the methods for deriving the pion mass value from the spatial separation from the 5g -- 4 f $π$N transition line and the 5g -- 4 f $μ$O transition line used as reference. Moreover, we discuss the importance to use dilute targets in order to minimize the influence of additional spectral lines from the presence of remaining electrons during the radiative emission. The occurrence of possible satellite lines is investigated via hypothesis testing methods using the Bayes factor.
△ Less
Submitted 30 September, 2016;
originally announced September 2016.
-
Measurement of the charged pion mass using X-ray spectroscopy of exotic atoms
Authors:
M Trassinelli,
D. F. Anagnostopoulos,
G. Borchert,
A. Dax,
J. P Egger,
D. Gotta,
M. Hennebach,
P. Indelicato,
Y. -W. Liu,
B. Manil,
N. Nelms,
L. M. Simons,
A. Wells
Abstract:
The $5g-4f$ transitions in pionic nitrogen and muonic oxygen were measured simultaneously by using a gaseous nitrogen-oxygen mixture at 1.4\,bar. Due to the precise knowledge of the muon mass the muonic line provides the energy calibration for the pionic transition. A value of (139.57077\,$\pm$\,0.00018)\,MeV/c$^{2}$ ($\pm$\,1.3ppm) is derived for the mass of the negatively charged pion, which is…
▽ More
The $5g-4f$ transitions in pionic nitrogen and muonic oxygen were measured simultaneously by using a gaseous nitrogen-oxygen mixture at 1.4\,bar. Due to the precise knowledge of the muon mass the muonic line provides the energy calibration for the pionic transition. A value of (139.57077\,$\pm$\,0.00018)\,MeV/c$^{2}$ ($\pm$\,1.3ppm) is derived for the mass of the negatively charged pion, which is 4.2ppm larger than the present world average.
△ Less
Submitted 11 May, 2016;
originally announced May 2016.
-
MOCABA: a general Monte Carlo-Bayes procedure for improved predictions of integral functions of nuclear data
Authors:
Axel Hoefer,
Oliver Buss,
Maik Hennebach,
Michael Schmid,
Dieter Porsch
Abstract:
MOCABA is a combination of Monte Carlo sampling and Bayesian updating algorithms for the prediction of integral functions of nuclear data, such as reactor power distributions or neutron multiplication factors. Similarly to the established Generalized Linear Least Squares (GLLS) methodology, MOCABA offers the capability to utilize integral experimental data to reduce the prior uncertainty of integr…
▽ More
MOCABA is a combination of Monte Carlo sampling and Bayesian updating algorithms for the prediction of integral functions of nuclear data, such as reactor power distributions or neutron multiplication factors. Similarly to the established Generalized Linear Least Squares (GLLS) methodology, MOCABA offers the capability to utilize integral experimental data to reduce the prior uncertainty of integral observables. The MOCABA approach, however, does not involve any series expansions and, therefore, does not suffer from the breakdown of first-order perturbation theory for large nuclear data uncertainties. This is related to the fact that, in contrast to the GLLS method, the updating mechanism within MOCABA is applied directly to the integral observables without having to "adjust" any nuclear data. A central part of MOCABA is the nuclear data Monte Carlo program NUDUNA, which performs random sampling of nuclear data evaluations according to their covariance information and converts them into libraries for transport code systems like MCNP or SCALE. What is special about MOCABA is that it can be applied to any integral function of nuclear data, and any integral measurement can be taken into account to improve the prediction of an integral observable of interest. In this paper we present two example applications of the MOCABA framework: the prediction of the neutron multiplication factor of a water-moderated PWR fuel assembly based on 21 criticality safety benchmark experiments and the prediction of the power distribution within a toy model reactor containing 100 fuel assemblies.
△ Less
Submitted 12 November, 2014;
originally announced November 2014.
-
Hadronic shift in pionic hydrogen
Authors:
M. Hennebach,
D. F. Anagnostopoulos,
A. Dax,
H. Fuhrmann,
D. Gotta,
A. Gruber,
A. Hirtl,
P. Indelicato,
Y. -W. Liu,
B. Manil,
V. E. Markushin,
A. J. Rusi el Hassani,
L. M. Simons,
M. Trassinelli,
J. Zmeskal
Abstract:
The hadronic shift in pionic hydrogen has been redetermined to be $ε_{1s}=7.086\,\pm\,0.007(stat)\,\pm\,0.006(sys)$\,eV by X-ray spectroscopy of ground state transitions applying various energy calibration schemes. The experiment was performed at the high-intensity low-energy pion beam of the Paul Scherrer Institut by using the cyclotron trap and an ultimate-resolution Bragg spectrometer with bent…
▽ More
The hadronic shift in pionic hydrogen has been redetermined to be $ε_{1s}=7.086\,\pm\,0.007(stat)\,\pm\,0.006(sys)$\,eV by X-ray spectroscopy of ground state transitions applying various energy calibration schemes. The experiment was performed at the high-intensity low-energy pion beam of the Paul Scherrer Institut by using the cyclotron trap and an ultimate-resolution Bragg spectrometer with bent crystals.
△ Less
Submitted 17 December, 2014; v1 submitted 25 June, 2014;
originally announced June 2014.
-
Characterization of a CCD array for Bragg spectroscopy
Authors:
Paul Indelicato,
Eric-Olivier Le Bigot,
Martino Trassinelli,
Detlev Gotta,
Maik Hennebach,
Nick Nelms,
Christian David,
Leopold M. Simons
Abstract:
The average pixel distance as well as the relative orientation of an array of 6 CCD detectors have been measured with accuracies of about 0.5 nm and 50 $μ$rad, respectively. Such a precision satisfies the needs of modern crystal spectroscopy experiments in the field of exotic atoms and highly charged ions. Two different measurements have been performed by illuminating masks in front of the detec…
▽ More
The average pixel distance as well as the relative orientation of an array of 6 CCD detectors have been measured with accuracies of about 0.5 nm and 50 $μ$rad, respectively. Such a precision satisfies the needs of modern crystal spectroscopy experiments in the field of exotic atoms and highly charged ions. Two different measurements have been performed by illuminating masks in front of the detector array by remote sources of radiation. In one case, an aluminum mask was irradiated with X-rays and in a second attempt, a nanometric quartz wafer was illuminated by a light bulb. Both methods gave consistent results with a smaller error for the optical method. In addition, the thermal expansion of the CCD detectors was characterized between -105 C and -40 C.
△ Less
Submitted 23 February, 2006;
originally announced February 2006.