-
Fabrication and characterization of optical filters from polymeric aerogels loaded with diamond scattering particles
Authors:
Alyssa Barlis,
Haiquan Guo,
Kyle Helson,
Charles Bennett,
Yan Yan Chan,
Tobias Marriage,
Manuel Quijada,
Ariel Tokarz,
Stephanie Vivod,
Edward Wollack,
Thomas Essinger-Hileman
Abstract:
We have developed a suite of infrared-blocking filters made by embedding diamond scattering particles in a polyimide aerogel substrate. We demonstrate the ability to tune the spectral performance of the filters based on both the composition of the base aerogel material and the properties of the scattering particles. We summarize the fabrication, optical modeling, and characterization of these filt…
▽ More
We have developed a suite of infrared-blocking filters made by embedding diamond scattering particles in a polyimide aerogel substrate. We demonstrate the ability to tune the spectral performance of the filters based on both the composition of the base aerogel material and the properties of the scattering particles. We summarize the fabrication, optical modeling, and characterization of these filters. We investigate two polyimide base aerogel formulations and the effects of loading them with diamond scattering particles of varying sizes and relative densities. We describe a model for the filters' behavior using a combination of Maxwell Garnett and Mie Scattering techniques. We present optical characterization results for diamond-loaded aerogel filters with cutoff frequencies (50% transmittance) ranging between 2.5 and 15 THz, and confirm that the measured spectral performance is in agreement with our optical models. We also measure the filters' refractive index in the microwave and report findings in agreement with Maxwell Garnett model predictions (typically n < 1.08).
△ Less
Submitted 17 April, 2024; v1 submitted 29 January, 2024;
originally announced January 2024.
-
Cosmology Large Angular Scale Surveyor (CLASS): 90 GHz Telescope Pointing, Beam Profile, Window Function, and Polarization Performance
Authors:
Rahul Datta,
Michael K. Brewer,
Jullianna Denes Couto,
Joseph Eimer,
Yunyang Li,
Zhilei Xu,
Aamir Ali,
John W. Appel,
Charles L. Bennett,
Ricardo Bustos,
David T. Chuss,
Joseph Cleary,
Sumit Dahal,
Francisco Espinoza,
Thomas Essinger-Hileman,
Pedro Fluxá,
Kathleen Harrington,
Kyle Helson,
Jeffrey Iuliano,
John Karakla,
Tobias A. Marriage,
Sasha Novack,
Carolina Núñez,
Ivan L. Padilla,
Lucas Parker
, et al. (9 additional authors not shown)
Abstract:
The Cosmology Large Angular Scale Surveyor (CLASS) is a telescope array that observes the cosmic microwave background (CMB) over ~75% of the sky from the Atacama Desert, Chile, at frequency bands centered near 40, 90, 150, and 220 GHz. CLASS measures the large angular scale CMB polarization to constrain the tensor-to-scalar ratio and the optical depth to last scattering. This paper presents the op…
▽ More
The Cosmology Large Angular Scale Surveyor (CLASS) is a telescope array that observes the cosmic microwave background (CMB) over ~75% of the sky from the Atacama Desert, Chile, at frequency bands centered near 40, 90, 150, and 220 GHz. CLASS measures the large angular scale CMB polarization to constrain the tensor-to-scalar ratio and the optical depth to last scattering. This paper presents the optical characterization of the 90GHz telescope, which has been observing since July 2018. Observations of the Moon establish the pointing while dedicated observations of Jupiter are used for beam calibration. The standard deviations of the pointing error in azimuth, elevation, and boresight angle are 1.3, 2.1, and 2.0 arcminutes, respectively, over the first 3 years of observations. This corresponds to a pointing uncertainty ~7% of the beam's full width at half maximum (FWHM). The effective azimuthally-symmetrized 1D beam estimated at 90 GHz from per detector intensity beam maps has a FWHM of 0.614+/-0.003 deg and a solid angle of 136.3+/-0.6(stats.)+/-1.1(sys.) usr integrated to a radius of 4 deg. The corresponding beam window function drops to b_ell^2 = 0.92, 0.70, 0.14 at ell = 30, 100, 300, respectively, with relative uncertainties < 2% for ell < 200. Far-sidelobes are studied using detector-centered intensity maps of the Moon and measured to be at a level of 10^-3 or below relative to the peak. The polarization angle of Tau A estimated from preliminary survey maps is 149.6+/-0.2(stats.) deg in equatorial coordinates consistent with prior measurements. Instrumental temperature-to-polarization (T-to-P) leakage is measured at a 95% confidence upper limit of (1.7+/-0.1) x 10^-3 in single detector demodulated data using observations of Jupiter and the Moon. Using pair-differenced demodulated data, a 95% confidence upper limit of 3.6 x 10^-4 is obtained on the T-to-P leakage.
△ Less
Submitted 25 August, 2023;
originally announced August 2023.
-
On-sky performance of new 90 GHz detectors for the Cosmology Large Angular Scale Surveyor (CLASS)
Authors:
Carolina Núñez,
John W. Appel,
Michael K. Brewer,
Sarah Marie Bruno,
Rahul Datta,
Charles L. Bennett,
Ricardo Bustos,
David T. Chuss,
Sumit Dahal,
Kevin L. Denis,
Joseph Eimer,
Thomas Essinger-Hileman,
Kyle Helson,
Tobias Marriage,
Carolina Morales Pérez,
Ivan L. Padilla,
Matthew A. Petroff,
Karwan Rostem,
Duncan J. Watts,
Edward J. Wollack,
Zhilei Xu
Abstract:
The Cosmology Large Angular Scale Surveyor (CLASS) is a polarization-sensitive telescope array located at an altitude of 5,200 m in the Chilean Atacama Desert and designed to measure the polarized Cosmic Microwave Background (CMB) over large angular scales. The CLASS array is currently observing with three telescopes covering four frequency bands: one at 40 GHz (Q); one at 90 GHz (W1); and one dic…
▽ More
The Cosmology Large Angular Scale Surveyor (CLASS) is a polarization-sensitive telescope array located at an altitude of 5,200 m in the Chilean Atacama Desert and designed to measure the polarized Cosmic Microwave Background (CMB) over large angular scales. The CLASS array is currently observing with three telescopes covering four frequency bands: one at 40 GHz (Q); one at 90 GHz (W1); and one dichroic system at 150/220 GHz (HF). During the austral winter of 2022, we upgraded the first 90 GHz telescope (W1) by replacing four of the seven focal plane modules. These new modules contain detector wafers with an updated design, aimed at improving the optical efficiency and detector stability. We present a description of the design changes and measurements of on-sky optical efficiencies derived from observations of Jupiter.
△ Less
Submitted 23 March, 2023; v1 submitted 3 January, 2023;
originally announced January 2023.
-
Design and characterization of new 90 GHz detectors for the Cosmology Large Angular Scale Surveyor (CLASS)
Authors:
Carolina Núñez,
John W. Appel,
Sarah Marie Bruno,
Rahul Datta,
Aamir Ali,
Charles L. Bennett,
Sumit Dahal,
Jullianna Denes Couto,
Kevin L. Denis,
Joseph Eimer,
Francisco Espinoza,
Tom Essinger-Hileman,
Kyle Helson,
Jeffrey Iuliano,
Tobias A. Marriage,
Carolina Morales Pérez,
Deniz Augusto Nunes Valle,
Matthew A. Petroff,
Karwan Rostem,
Rui Shi,
Duncan J. Watts,
Edward J. Wollack,
Zhilei Xu
Abstract:
The Cosmology Large Angular Scale Surveyor (CLASS) is a polarization-sensitive telescope array located at an altitude of 5,200 m in the Chilean Atacama Desert. CLASS is designed to measure "E-mode" (even parity) and "B-mode" (odd parity) polarization patterns in the Cosmic Microwave Background (CMB) over large angular scales with the aim of improving our understanding of inflation, reionization, a…
▽ More
The Cosmology Large Angular Scale Surveyor (CLASS) is a polarization-sensitive telescope array located at an altitude of 5,200 m in the Chilean Atacama Desert. CLASS is designed to measure "E-mode" (even parity) and "B-mode" (odd parity) polarization patterns in the Cosmic Microwave Background (CMB) over large angular scales with the aim of improving our understanding of inflation, reionization, and dark matter. CLASS is currently observing with three telescopes covering four frequency bands: one at 40 GHz (Q); one at 90 GHz (W1); and one dichroic system at 150/220 GHz (G). In these proceedings, we discuss the updated design and in-lab characterization of new 90 GHz detectors. The new detectors include design changes to the transition-edge sensor (TES) bolometer architecture, which aim to improve stability and optical efficiency. We assembled and tested four new detector wafers, to replace four modules of the W1 focal plane. These detectors were installed into the W1 telescope, and will achieve first light in the austral winter of 2022. We present electrothermal parameters and bandpass measurements from in-lab dark and optical testing. From in-lab dark tests, we also measure a median NEP of 12.3 $\mathrm{aW\sqrt{s}}$ across all four wafers about the CLASS signal band, which is below the expected photon NEP of 32 $\mathrm{aW\sqrt{s}}$ from the field. We therefore expect the new detectors to be photon noise limited.
△ Less
Submitted 9 August, 2022;
originally announced August 2022.
-
Characterization of aerogel scattering filters for astronomical telescopes
Authors:
Alyssa Barlis,
Stefan Arseneau,
Charles L. Bennett,
Thomas Essinger-Hileman,
Haiquan Guo,
Kyle R. Helson,
Tobias Marriage,
Manuel A. Quijada,
Ariel E. Tokarz,
Stephanie L. Vivod,
Edward J. Wollack
Abstract:
We have developed a suite of novel infrared-blocking filters made by embedding scattering particles in a polymer aerogel substrate. Our developments allow us to tune the spectral performance of the filters based on both the composition of the base aerogel material and the properties of the scattering particles. Our filters are targeted for use in a variety of applications, from ground-based CMB ex…
▽ More
We have developed a suite of novel infrared-blocking filters made by embedding scattering particles in a polymer aerogel substrate. Our developments allow us to tune the spectral performance of the filters based on both the composition of the base aerogel material and the properties of the scattering particles. Our filters are targeted for use in a variety of applications, from ground-based CMB experiments to planetary science probes. We summarize the formulations we have fabricated and tested to date, including several polyimide base aerogel formulations incorporating a range of size distributions of diamond scattering particles. We also describe the spectral characterization techniques used to measure the filters' optical properties, including the development of a mm-wave Fourier transform spectrometer testbed.
△ Less
Submitted 8 August, 2022;
originally announced August 2022.
-
Novel infrared-blocking aerogel scattering filters and their applications in astrophysical and planetary science
Authors:
Kyle R. Helson,
Stefan Arseneau,
Alyssa Barlis,
Charles L. Bennett,
Thomas M. Essinger-Hileman,
Haiquan Guo,
Tobias Marriage,
Manuel A. Quijada,
Ariel E. Tokarz,
Stephanie L. Vivod,
Edward J. Wollack
Abstract:
Infrared-blocking scattering aerogel filters have a broad range of potential applications in astrophysics and planetary science observations in the far-infrared, sub-millimeter, and microwave regimes. Successful dielectric modeling of aerogel filters allowed the fabrication of samples to meet the mechanical and science instrument requirements for several experiments, including the Sub-millimeter S…
▽ More
Infrared-blocking scattering aerogel filters have a broad range of potential applications in astrophysics and planetary science observations in the far-infrared, sub-millimeter, and microwave regimes. Successful dielectric modeling of aerogel filters allowed the fabrication of samples to meet the mechanical and science instrument requirements for several experiments, including the Sub-millimeter Solar Observation Lunar Volatiles Experiment (SSOLVE), the Cosmology Large Angular Scale Surveyor (CLASS), and the Experiment for Cryogenic Large-Aperture Intensity Map** (EXCLAIM). Thermal multi-physics simulations of the filters predict their performance when integrated into a cryogenic receiver. Prototype filters have survived cryogenic cycling to 4K with no degradation in mechanical properties.
△ Less
Submitted 17 August, 2022; v1 submitted 7 August, 2022;
originally announced August 2022.
-
Four-year Cosmology Large Angular Scale Surveyor (CLASS) Observations: On-sky Receiver Performance at 40, 90, 150, and 220 GHz Frequency Bands
Authors:
Sumit Dahal,
John W. Appel,
Rahul Datta,
Michael K. Brewer,
Aamir Ali,
Charles L. Bennett,
Ricardo Bustos,
Manwei Chan,
David T. Chuss,
Joseph Cleary,
Jullianna D. Couto,
Kevin L. Denis,
Rolando Dünner,
Joseph Eimer,
Francisco Espinoza,
Thomas Essinger-Hileman,
Joseph E. Golec,
Kathleen Harrington,
Kyle Helson,
Jeffrey Iuliano,
John Karakla,
Yunyang Li,
Tobias A. Marriage,
Jeffrey J. McMahon,
Nathan J. Miller
, et al. (15 additional authors not shown)
Abstract:
The Cosmology Large Angular Scale Surveyor (CLASS) observes the polarized cosmic microwave background (CMB) over the angular scales of 1$^\circ \lesssim θ\leq$ 90$^\circ$ with the aim of characterizing primordial gravitational waves and cosmic reionization. We report on the on-sky performance of the CLASS Q-band (40 GHz), W-band (90 GHz), and dichroic G-band (150/220 GHz) receivers that have been…
▽ More
The Cosmology Large Angular Scale Surveyor (CLASS) observes the polarized cosmic microwave background (CMB) over the angular scales of 1$^\circ \lesssim θ\leq$ 90$^\circ$ with the aim of characterizing primordial gravitational waves and cosmic reionization. We report on the on-sky performance of the CLASS Q-band (40 GHz), W-band (90 GHz), and dichroic G-band (150/220 GHz) receivers that have been operational at the CLASS site in the Atacama desert since June 2016, May 2018, and September 2019, respectively. We show that the noise-equivalent power measured by the detectors matches the expected noise model based on on-sky optical loading and lab-measured detector parameters. Using Moon, Venus, and Jupiter observations, we obtain power-to-antenna-temperature calibrations and optical efficiencies for the telescopes. From the CMB survey data, we compute instantaneous array noise-equivalent-temperature sensitivities of 22, 19, 23, and 71 $\mathrm{μK}_\mathrm{cmb}\sqrt{\mathrm{s}}$ for the 40, 90, 150, and 220 GHz frequency bands, respectively. These noise temperatures refer to white noise amplitudes, which contribute to sky maps at all angular scales. Future papers will assess additional noise sources impacting larger angular scales.
△ Less
Submitted 9 February, 2022; v1 submitted 16 July, 2021;
originally announced July 2021.
-
Anti-reflection Coated Vacuum Window for the Primordial Inflation Polarization ExploreR (PIPER) balloon-borne instrument
Authors:
Rahul Datta,
David T. Chuss,
Joseph Eimer,
Thomas Essinger-Hileman,
Natalie N. Gandilo,
Kyle Helson,
Alan J. Kogut,
Luke Lowe,
Paul Mirel,
Karwan Rostem,
Marco Sagliocca,
Danielle Sponseller,
Eric R. Switzer,
Peter A. Taraschi,
Edward J. Wollack
Abstract:
Measuring the faint polarization signal of the cosmic microwave background (CMB) not only requires high optical throughput and instrument sensitivity but also control over systematic effects. Polarimetric cameras or receivers used in this setting often employ dielectric vacuum windows, filters, or lenses to appropriately prepare light for detection by cooled sensor arrays. These elements in the op…
▽ More
Measuring the faint polarization signal of the cosmic microwave background (CMB) not only requires high optical throughput and instrument sensitivity but also control over systematic effects. Polarimetric cameras or receivers used in this setting often employ dielectric vacuum windows, filters, or lenses to appropriately prepare light for detection by cooled sensor arrays. These elements in the optical chain are typically designed to minimize reflective losses and hence improve sensitivity while minimizing potential imaging artifacts such as glint and ghosting. The Primordial Inflation Polarization ExploreR (PIPER) is a balloon-borne instrument designed to measure the polarization of the CMB radiation at the largest angular scales and characterize astrophysical dust foregrounds. PIPER's twin telescopes and detector systems are submerged in an open-aperture liquid helium bucket dewar. A fused-silica window anti-reflection (AR) coated with polytetrafluoroethylene (PTFE) is installed on the vacuum cryostat that houses the cryogenic detector arrays. Light passes from the skyward portions of the telescope to the detector arrays though this window, which utilizes an indium seal to prevent superfluid helium leaks into the vacuum cryostat volume. The AR coating implemented reduces reflections from each interface to <1% compared to ~10% from an uncoated window surface. The AR coating procedure and room temperature optical measurements of the window are presented. The indium vacuum sealing process is also described in detail and test results characterizing its integrity to superfluid helium leaks are provided.
△ Less
Submitted 14 March, 2021;
originally announced March 2021.
-
The CLASS 150/220 GHz Polarimeter Array: Design, Assembly, and Characterization
Authors:
Sumit Dahal,
Mandana Amiri,
John W. Appel,
Charles L. Bennett,
Lance Corbett,
Rahul Datta,
Kevin Denis,
Thomas Essinger-Hileman,
Mark Halpern,
Kyle Helson,
Gene Hilton,
Johannes Hubmayr,
Benjamin Keller,
Tobias Marriage,
Carolina Nunez,
Matthew Petroff,
Carl Reintsema,
Karwan Rostem,
Kongpop U-Yen,
Edward Wollack
Abstract:
We report on the development of a polarization-sensitive dichroic (150/220 GHz) detector array for the Cosmology Large Angular Scale Surveyor (CLASS) delivered to the telescope site in June 2019. In concert with existing 40 and 90 GHz telescopes, the 150/220 GHz telescope will make observations of the cosmic microwave background over large angular scales aimed at measuring the primordial B-mode si…
▽ More
We report on the development of a polarization-sensitive dichroic (150/220 GHz) detector array for the Cosmology Large Angular Scale Surveyor (CLASS) delivered to the telescope site in June 2019. In concert with existing 40 and 90 GHz telescopes, the 150/220 GHz telescope will make observations of the cosmic microwave background over large angular scales aimed at measuring the primordial B-mode signal, the optical depth to reionization, and other fundamental physics and cosmology. The 150/220 GHz focal plane array consists of three detector modules with 1020 transition edge sensor (TES) bolometers in total. Each dual-polarization pixel on the focal plane contains four bolometers to measure the two linear polarization states at 150 and 220 GHz. Light is coupled through a planar orthomode transducer (OMT) fed by a smooth-walled feedhorn array made from an aluminum-silicon alloy (CE7). In this work, we discuss the design, assembly, and in-lab characterization of the 150/220 GHz detector array. The detectors are photon-noise limited, and we estimate the total array noise-equivalent power (NEP) to be 2.5 and 4 aW$\sqrt{\mathrm{s}}$ for 150 and 220 GHz arrays, respectively.
△ Less
Submitted 16 January, 2020; v1 submitted 1 August, 2019;
originally announced August 2019.
-
Dielectric Properties of Conductively Loaded Polyimides in the Far Infrared
Authors:
Kyle R. Helson,
Kevin H. Miller Karwan Rostem,
Manuel Quijada,
Edward J. Wollack
Abstract:
The dielectric properties of selected conductively-loaded polyimide samples are characterized in microwave through far infrared wavebands. These materials, belonging to the Vespel\textsuperscript{\textregistered} family, are more readily formed by direct machining than their ceramic loaded epoxy counterparts and present an interesting solution for realizing absorptive optical control structures. M…
▽ More
The dielectric properties of selected conductively-loaded polyimide samples are characterized in microwave through far infrared wavebands. These materials, belonging to the Vespel\textsuperscript{\textregistered} family, are more readily formed by direct machining than their ceramic loaded epoxy counterparts and present an interesting solution for realizing absorptive optical control structures. Measurements spanning a spectral range from 1 to 600\,${\rm cm^{-1}}$ (0.03 to 18\,THz) were preformed and used in parametrization of the media's dielectric function at frequencies below $\approx3\,$THz.
△ Less
Submitted 11 October, 2018; v1 submitted 30 August, 2018;
originally announced October 2018.
-
Aerogel scattering filters for cosmic microwave background observations
Authors:
Thomas Essinger-Hileman,
Charles L. Bennett,
Lance Corbett,
Haiquan Guo,
Kyle Helson,
Tobias Marriage,
Mary Ann B. Meador,
Karwan Rostem,
Edward J. Wollack
Abstract:
We present the design and performance of broadband and tunable infrared-blocking filters for millimeter and sub-millimeter astronomy composed of small scattering particles embedded in an aerogel substrate. The ultra-low-density (typically < 150 mg/cm^3) aerogel substrate provides an index of refraction as low as 1.05, removing the need for anti-reflection coatings and allowing for broadband operat…
▽ More
We present the design and performance of broadband and tunable infrared-blocking filters for millimeter and sub-millimeter astronomy composed of small scattering particles embedded in an aerogel substrate. The ultra-low-density (typically < 150 mg/cm^3) aerogel substrate provides an index of refraction as low as 1.05, removing the need for anti-reflection coatings and allowing for broadband operation from DC to above 1 THz. The size distribution of the scattering particles can be tuned to provide a variable cutoff frequency. Aerogel filters with embedded high-resistivity silicon powder are being produced at 40-cm diameter to enable large-aperture cryogenic receivers for cosmic microwave background polarimeters, which require large arrays of sub-Kelvin detectors in their search for the signature of an inflationary gravitational-wave background.
△ Less
Submitted 13 May, 2020; v1 submitted 11 July, 2018;
originally announced July 2018.
-
The Cosmology Large Angular Scale Surveyor Receiver Design
Authors:
Jeffrey Iuliano,
Joseph Eimer,
Lucas Parker,
Gary Rhoades,
Aamir Ali,
John W. Appel,
Charles Bennett,
Michael Brewer,
Ricardo Bustos,
David Chuss,
Joseph Cleary,
Jullianna Couto,
Sumit Dahal,
Kevin Denis,
Rolando Dünner,
Thomas Essinger-Hileman,
Pedro Fluxa,
Mark Halpern,
Kathleen Harrington,
Kyle Helson,
Gene Hilton,
Gary Hinshaw,
Johannes Hubmayr,
John Karakla,
Tobias Marriage
, et al. (20 additional authors not shown)
Abstract:
The Cosmology Large Angular Scale Surveyor consists of four instruments performing a CMB polarization survey. Currently, the 40 GHz and first 90 GHz instruments are deployed and observing, with the second 90 GHz and a multichroic 150/220 GHz instrument to follow. The receiver is a central component of each instrument's design and functionality. This paper describes the CLASS receiver design, using…
▽ More
The Cosmology Large Angular Scale Surveyor consists of four instruments performing a CMB polarization survey. Currently, the 40 GHz and first 90 GHz instruments are deployed and observing, with the second 90 GHz and a multichroic 150/220 GHz instrument to follow. The receiver is a central component of each instrument's design and functionality. This paper describes the CLASS receiver design, using the first 90 GHz receiver as a primary reference. Cryogenic cooling and filters maintain a cold, low-noise environment for the detectors. We have achieved receiver detector temperatures below 50 mK in the 40 GHz instrument for 85% of the initial 1.5 years of operation, and observed in-band efficiency that is consistent with pre-deployment estimates. At 90 GHz, less than 26% of in-band power is lost to the filters and lenses in the receiver, allowing for high optical efficiency. We discuss the mounting scheme for the filters and lenses, the alignment of the cold optics and detectors, stray light control, and magnetic shielding.
△ Less
Submitted 23 July, 2018; v1 submitted 11 July, 2018;
originally announced July 2018.
-
Design and characterization of the Cosmology Large Angular Scale Surveyor (CLASS) 93 GHz focal plane
Authors:
Sumit Dahal,
Aamir Ali,
John W. Appel,
Thomas Essinger-Hileman,
Charles Bennett,
Michael Brewer,
Ricardo Bustos,
Manwei Chan,
David T. Chuss,
Joseph Cleary,
Felipe Colazo,
Jullianna Couto,
Kevin Denis,
Rolando Dünner,
Joseph Eimer,
Trevor Engelhoven,
Pedro Fluxa,
Mark Halpern,
Kathleen Harrington,
Kyle Helson,
Gene Hilton,
Gary Hinshaw,
Johannes Hubmayr,
Jeffrey Iuliano,
Tobias Marriage
, et al. (22 additional authors not shown)
Abstract:
The Cosmology Large Angular Scale Surveyor (CLASS) aims to detect and characterize the primordial B-mode signal and make a sample-variance-limited measurement of the optical depth to reionization. CLASS is a ground-based, multi-frequency microwave polarimeter that surveys 70% of the microwave sky every day from the Atacama Desert. The focal plane detector arrays of all CLASS telescopes contain smo…
▽ More
The Cosmology Large Angular Scale Surveyor (CLASS) aims to detect and characterize the primordial B-mode signal and make a sample-variance-limited measurement of the optical depth to reionization. CLASS is a ground-based, multi-frequency microwave polarimeter that surveys 70% of the microwave sky every day from the Atacama Desert. The focal plane detector arrays of all CLASS telescopes contain smooth-walled feedhorns that couple to transition-edge sensor (TES) bolometers through symmetric planar orthomode transducer (OMT) antennas. These low noise polarization-sensitive detector arrays are fabricated on mono-crystalline silicon wafers to maintain TES uniformity and optimize optical efficiency throughout the wafer. In this paper, we discuss the design and characterization of the first CLASS 93 GHz detector array. We measure the dark parameters, bandpass, and noise spectra of the detectors and report that the detectors are photon-noise limited. With current array yield of 82%, we estimate the total array noise-equivalent power (NEP) to be 2.1 aW$\sqrt[]{\mathrm{s}}$.
△ Less
Submitted 10 July, 2018;
originally announced July 2018.
-
The EBEX Balloon Borne Experiment - Detectors and Readout
Authors:
The EBEX Collaboration,
Maximilian Abitbol,
Asad M. Aboobaker,
Peter Ade,
Derek Araujo,
François Aubin,
Carlo Baccigalupi,
Chaoyun Bao,
Daniel Chapman,
Joy Didier,
Matt Dobbs,
Stephen M. Feeney,
Christopher Geach,
Will Grainger,
Shaul Hanany,
Kyle Helson,
Seth Hillbrand,
Gene Hilton,
Johannes Hubmayr,
Kent Irwin,
Andrew Jaffe,
Bradley Johnson,
Terry Jones,
Jeff Klein,
Andrei Korotkov
, et al. (15 additional authors not shown)
Abstract:
EBEX was a long-duration balloon-borne experiment to measure the polarization of the cosmic microwave background. The experiment had three frequency bands centered at 150, 250, and 410 GHz and was the first to use a kilo-pixel array of transition edge sensor (TES) bolometers aboard a balloon platform; shortly after reaching float we operated 504, 342, and 109 TESs at each of the bands, respectivel…
▽ More
EBEX was a long-duration balloon-borne experiment to measure the polarization of the cosmic microwave background. The experiment had three frequency bands centered at 150, 250, and 410 GHz and was the first to use a kilo-pixel array of transition edge sensor (TES) bolometers aboard a balloon platform; shortly after reaching float we operated 504, 342, and 109 TESs at each of the bands, respectively. We describe the design and characterization of the array and the readout system. We give the distributions of measured thermal conductances, normal resistances, and transition temperatures. With the exception of the thermal conductance at 150 GHz. We measured median low-loop-gain time constants $τ_{0}=$ 88, 46, and 57 ms and compare them to predictions. Two measurements of bolometer absorption efficiency show high ($\sim$0.9) efficiency at 150 GHz and medium ($\sim$0.35, and $\sim$0.25) at the two higher bands, respectively. We measure a median total optical load of 3.6, 5.3 and 5.0 pW absorbed at the three bands, respectively. EBEX pioneered the use of the digital version of the frequency domain multiplexing (FDM) system which multiplexed the bias and readout of 16 bolometers onto two wires. We present accounting of the measured noise equivalent power. The median per-detector noise equivalent temperatures referred to a black body with a temperature of 2.725 K are 400, 920, and 14500 $μ$K$\sqrt{s}$ for the three bands, respectively. We compare these values to our pre-flight predictions and to a previous balloon payload, discuss the sources of excess noise, and the path for a future payload to make full use of the balloon environment.
△ Less
Submitted 30 July, 2018; v1 submitted 2 March, 2018;
originally announced March 2018.
-
Intensity-Coupled-Polarization in Instruments with a Continuously Rotating Half-Wave Plate
Authors:
Joy Didier,
Amber D. Miller,
Derek Araujo,
François Aubin,
Christopher Geach,
Bradley Johnson,
Andrei Korotkov,
Kate Raach,
Benjamin Westbrook,
Karl Young,
Asad M. Aboobaker,
Peter Ade,
Carlo Baccigalupi,
Chaoyun Bao,
Daniel Chapman,
Matt Dobbs,
Will Grainger,
Shaul Hanany,
Kyle Helson,
Seth Hillbrand,
Johannes Hubmayr,
Andrew Jaffe,
Terry Jones,
Jeff Klein,
Adrian Lee
, et al. (9 additional authors not shown)
Abstract:
We discuss a systematic effect associated with measuring polarization with a continuously rotating half-wave plate. The effect was identified with the data from the E and B Experiment (EBEX), which was a balloon-borne instrument designed to measure the polarization of the CMB as well as that from Galactic dust. The data show polarization fraction larger than 10\% while less than 3\% were expected…
▽ More
We discuss a systematic effect associated with measuring polarization with a continuously rotating half-wave plate. The effect was identified with the data from the E and B Experiment (EBEX), which was a balloon-borne instrument designed to measure the polarization of the CMB as well as that from Galactic dust. The data show polarization fraction larger than 10\% while less than 3\% were expected from instrumental polarization. We give evidence that the excess polarization is due to detector non-linearity in the presence of a continuously rotating HWP. The non-linearity couples intensity signals into polarization. We develop a map-based method to remove the excess polarization. Applying this method for the 150 (250) GHz bands data we find that 81\% (92\%) of the excess polarization was removed. Characterization and mitigation of this effect is important for future experiments aiming to measure the CMB B-modes with a continuously rotating HWP.
△ Less
Submitted 28 February, 2018; v1 submitted 3 November, 2017;
originally announced November 2017.
-
A Compact Cryogenic Thermal Source for Detector Array Characterization
Authors:
David T. Chuss,
Karwan Rostem,
Edward J. Wollack,
Leah Berman,
Felipe Colazo,
Martin DeGeorge,
Kyle Helson,
Marco Sagliocca
Abstract:
We describe the design, fabrication, and validation of a cryogenically-compatible quasioptical thermal source designed to be used for characterization of detector arrays. The source is constructed using a graphite-loaded epoxy mixture that is molded into a tiled pyramidal structure. The mold is fabricated using a hardened steel template produced via a wire EDM process. The absorptive mixture is bo…
▽ More
We describe the design, fabrication, and validation of a cryogenically-compatible quasioptical thermal source designed to be used for characterization of detector arrays. The source is constructed using a graphite-loaded epoxy mixture that is molded into a tiled pyramidal structure. The mold is fabricated using a hardened steel template produced via a wire EDM process. The absorptive mixture is bonded to a copper backplate enabling thermalization of the entire structure. The source reflectance is measured from 30-300 GHz and compared to models.
△ Less
Submitted 18 July, 2017;
originally announced July 2017.
-
The EBEX Balloon Borne Experiment - Optics, Receiver, and Polarimetry
Authors:
The EBEX Collaboration,
Asad M. Aboobaker,
Peter Ade,
Derek Araujo,
François Aubin,
Carlo Baccigalupi,
Chaoyun Bao,
Daniel Chapman,
Joy Didier,
Matt Dobbs,
Christopher Geach,
Will Grainger,
Shaul Hanany,
Kyle Helson,
Seth Hillbrand,
Johannes Hubmayr,
Andrew Jaffe,
Bradley Johnson,
Terry Jones,
Jeff Klein,
Andrei Korotkov,
Adrian Lee,
Lorne Levinson,
Michele Limon,
Kevin MacDermid
, et al. (13 additional authors not shown)
Abstract:
The E and B Experiment (EBEX) was a long-duration balloon-borne cosmic microwave background polarimeter that flew over Antarctica in 2013. We describe the experiment's optical system, receiver, and polarimetric approach, and report on their in-flight performance. EBEX had three frequency bands centered on 150, 250, and 410 GHz. To make efficient use of limited mass and space we designed a 115 cm…
▽ More
The E and B Experiment (EBEX) was a long-duration balloon-borne cosmic microwave background polarimeter that flew over Antarctica in 2013. We describe the experiment's optical system, receiver, and polarimetric approach, and report on their in-flight performance. EBEX had three frequency bands centered on 150, 250, and 410 GHz. To make efficient use of limited mass and space we designed a 115 cm$^{2}$sr high throughput optical system that had two ambient temperature mirrors and four anti-reflection coated polyethylene lenses per focal plane. All frequency bands shared the same optical train. Polarimetry was achieved with a continuously rotating achromatic half-wave plate (AHWP) that was levitated with a superconducting magnetic bearing (SMB). Rotation stability was 0.45 % over a period of 10 hours, and angular position accuracy was 0.01 degrees. This is the first use of a SMB in astrophysics. The measured modulation efficiency was above 90 % for all bands. To our knowledge the 109 % fractional bandwidth of the AHWP was the broadest implemented to date. The receiver that contained one lens and the AHWP at a temperature of 4 K, the polarizing grid and other lenses at 1 K, and the two focal planes at 0.25 K performed according to specifications giving focal plane temperature stability with fluctuation power spectrum that had $1/f$ knee at 2 mHz. EBEX was the first balloon-borne instrument to implement technologies characteristic of modern CMB polarimeters including high throughput optical systems, and large arrays of transition edge sensor bolometric detectors with mutiplexed readouts.
△ Less
Submitted 30 May, 2017; v1 submitted 10 March, 2017;
originally announced March 2017.
-
The EBEX Balloon-Borne Experiment - Gondola, Attitude Control, and Control Software
Authors:
The EBEX Collaboration,
Asad Aboobaker,
Peter Ade,
Derek Araujo,
François Aubin,
Carlo Baccigalupi,
Chaoyun Bao,
Daniel Chapman,
Joy Didier,
Matt Dobbs,
Will Grainger,
Shaul Hanany,
Kyle Helson,
Seth Hillbrand,
Johannes Hubmayr,
Andrew Jaffe,
Bradley Johnson,
Terry Jones,
Jeff Klein,
Andrei Korotkov,
Adrian Lee,
Lorne Levinson,
Michele Limon,
Kevin MacDermid,
Amber D. Miller
, et al. (11 additional authors not shown)
Abstract:
The E and B Experiment (EBEX) was a long-duration balloon-borne instrument designed to measure the polarization of the cosmic microwave background (CMB) radiation. EBEX was the first balloon-borne instrument to implement a kilo-pixel array of transition edge sensor (TES) bolometric detectors and the first CMB experiment to use the digital version of the frequency domain multiplexing system for rea…
▽ More
The E and B Experiment (EBEX) was a long-duration balloon-borne instrument designed to measure the polarization of the cosmic microwave background (CMB) radiation. EBEX was the first balloon-borne instrument to implement a kilo-pixel array of transition edge sensor (TES) bolometric detectors and the first CMB experiment to use the digital version of the frequency domain multiplexing system for readout of the TES array. The scan strategy relied on 40 s peak-to-peak constant velocity azimuthal scans. We discuss the unique demands on the design and operation of the payload that resulted from these new technologies and the scan strategy. We describe the solutions implemented including the development of a power system designed to provide a total of at least 2.3 kW, a cooling system to dissipate 590 W consumed by the detectors' readout system, software to manage and handle the data of the kilo-pixel array, and specialized attitude reconstruction software. We present flight performance data showing faultless management of the TES array, adequate powering and cooling of the readout electronics, and constraint of attitude reconstruction errors such that the spurious B-modes they induced were less than 10% of CMB B-mode power spectrum with $r=0.05$.
△ Less
Submitted 11 April, 2017; v1 submitted 22 February, 2017;
originally announced February 2017.
-
A high-resolution pointing system for fast scanning platforms: The EBEX example
Authors:
Joy Didier,
Daniel Chapman,
Asad Aboobaker,
Derek Araujo,
Will Grainger,
Shaul Hanany,
Kyle Helson,
Seth Hillbrand,
Andrei Korotkov,
Michele Limon,
Amber Miller,
Britt Reichborn-Kjennerud,
Ilan Sagiv,
Greg Tucker,
Yuri Vinokurov
Abstract:
The E and B experiment (EBEX) is a balloon-borne telescope designed to measure the polarization of the cosmic microwave background with 8' resolution employing a gondola scanning with speeds of order degree per second. In January 2013, EBEX completed 11 days of observations in a flight over Antarctica covering $\sim$ 6000 square degrees of the sky. The payload is equipped with two redundant star c…
▽ More
The E and B experiment (EBEX) is a balloon-borne telescope designed to measure the polarization of the cosmic microwave background with 8' resolution employing a gondola scanning with speeds of order degree per second. In January 2013, EBEX completed 11 days of observations in a flight over Antarctica covering $\sim$ 6000 square degrees of the sky. The payload is equipped with two redundant star cameras and two sets of three orthogonal gyroscopes to reconstruct the telescope attitude. The EBEX science goals require the pointing to be reconstructed to approximately 10" in the map domain, and in-flight attitude control requires the real time pointing to be accurate to $\sim$ 0.5$^{\circ}$ . The high velocity scan strategy of EBEX coupled to its float altitude only permits the star cameras to take images at scan turnarounds, every $\sim$ 40 seconds, and thus requires the development of a pointing system with low noise gyroscopes and carefully controlled systematic errors. Here we report on the design of the pointing system and on a simulation pipeline developed to understand and minimize the effects of systematic errors. The performance of the system is evaluated using the 2012/2013 flight data, and we show that we achieve a pointing error with RMS=25" on 40 seconds azimuth throws, corresponding to an error of $\sim$ 4.6" in the map domain.
△ Less
Submitted 9 February, 2016;
originally announced February 2016.
-
Temperature calibration of the E and B experiment
Authors:
Francois Aubin,
Asad M. Aboobaker,
Peter Ade,
Derek Araujo,
Carlo Baccigalupi,
Chaoyun Bao,
Julian Borrill,
Daniel Chapman,
Joy Didier,
Matt Dobbs,
Stephen Feeney,
Christopher Geach,
Shaul Hanany,
Kyle Helson,
Seth Hillbrand,
Gene Hilton,
Johannes Hubmayr,
Andrew Jaffe,
Bradley Johnson,
Terry Jones,
Theodore Kisner,
Jeff Klein,
Andrei Korotkov,
Adrian Lee,
Lorne Levinson
, et al. (18 additional authors not shown)
Abstract:
The E and B Experiment (EBEX) is a balloon-borne polarimeter designed to measure the polarization of the cosmic microwave background radiation and to characterize the polarization of galactic dust. EBEX was launched December 29, 2012 and circumnavigated Antarctica observing $\sim$6,000 square degrees of sky during 11 days at three frequency bands centered around 150, 250 and 410 GHz. EBEX was the…
▽ More
The E and B Experiment (EBEX) is a balloon-borne polarimeter designed to measure the polarization of the cosmic microwave background radiation and to characterize the polarization of galactic dust. EBEX was launched December 29, 2012 and circumnavigated Antarctica observing $\sim$6,000 square degrees of sky during 11 days at three frequency bands centered around 150, 250 and 410 GHz. EBEX was the first experiment to operate a kilo-pixel array of transition-edge sensor bolometers and a continuously rotating achromatic half-wave plate aboard a balloon platform. It also pioneered the use of detector readout based on digital frequency domain multiplexing.
We describe the temperature calibration of the experiment. The gain response of the experiment is calibrated using a two-step iterative process. We use signals measured on passes across the Galactic plane to convert from readout-system counts to power. The effective smoothing scale of the EBEX optics and the star camera-to-detector offset angles are determined through \c{hi}2 minimization using the compact HII region RCW 38. This two-step process is initially performed with parameters measured before the EBEX 2013 flight and then repeated until the calibration factor and parameters converge.
△ Less
Submitted 28 January, 2016;
originally announced January 2016.
-
The performance of the bolometer array and readout system during the 2012/2013 flight of the E and B experiment (EBEX)
Authors:
Kevin MacDermid,
Asad M. Aboobaker,
Peter Ade,
Francois Aubin,
Carlo Baccigalupi,
Kevin Bandura,
Chaoyun Bao,
Julian Borrill,
Daniel Chapman,
Joy Didier,
Matt Dobbs,
Julien Grain,
Will Grainger,
Shaul Hanany,
Kyle Helson,
Seth Hillbrand,
Gene Hilton,
Hannes Hubmayr,
Kent Irwin,
Bradley Johnson,
Andrew Jaffe,
Terry Jones,
Ted Kisner,
Jeff Klein,
Andrei Korotkov
, et al. (16 additional authors not shown)
Abstract:
EBEX is a balloon-borne telescope designed to measure the polarization of the cosmic microwave background radiation. During its eleven day science flight in the Austral Summer of 2012, it operated 955 spider-web transition edge sensor (TES) bolometers separated into bands at 150, 250 and 410 GHz. This is the first time that an array of TES bolometers has been used on a balloon platform to conduct…
▽ More
EBEX is a balloon-borne telescope designed to measure the polarization of the cosmic microwave background radiation. During its eleven day science flight in the Austral Summer of 2012, it operated 955 spider-web transition edge sensor (TES) bolometers separated into bands at 150, 250 and 410 GHz. This is the first time that an array of TES bolometers has been used on a balloon platform to conduct science observations. Polarization sensitivity was provided by a wire grid and continuously rotating half-wave plate. The balloon implementation of the bolometer array and readout electronics presented unique development requirements. Here we present an outline of the readout system, the remote tuning of the bolometers and Superconducting QUantum Interference Device (SQUID) amplifiers, and preliminary current noise of the bolometer array and readout system.
△ Less
Submitted 22 July, 2014;
originally announced July 2014.
-
Thermal architecture for the SPIDER flight cryostat
Authors:
J. E. Gudmundsson,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
R. Bihary,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
B. P. Crill,
D. O'Dea,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
N. N. Gandilo,
S. R. Golwala,
M. Halpern,
M. Hasselfield,
K. R. Helson,
G. Hilton,
W. Holmes,
V. V. Hristov,
K. D. Irwin
, et al. (18 additional authors not shown)
Abstract:
We describe the cryogenic system for SPIDER, a balloon-borne microwave polarimeter that will map 8% of the sky with degree-scale angular resolution. The system consists of a 1284 L liquid helium cryostat and a 16 L capillary-filled superfluid helium tank, which provide base operating temperatures of 4 K and 1.5 K, respectively. Closed-cycle helium-3 adsorption refrigerators supply sub-Kelvin cooli…
▽ More
We describe the cryogenic system for SPIDER, a balloon-borne microwave polarimeter that will map 8% of the sky with degree-scale angular resolution. The system consists of a 1284 L liquid helium cryostat and a 16 L capillary-filled superfluid helium tank, which provide base operating temperatures of 4 K and 1.5 K, respectively. Closed-cycle helium-3 adsorption refrigerators supply sub-Kelvin cooling power to multiple focal planes, which are housed in monochromatic telescope inserts. The main helium tank is suspended inside the vacuum vessel with thermally insulating fiberglass flexures, and shielded from thermal radiation by a combination of two vapor cooled shields and multi-layer insulation. This system allows for an extremely low instrumental background and a hold time in excess of 25 days. The total mass of the cryogenic system, including cryogens, is approximately 1000 kg. This enables conventional long duration balloon flights. We will discuss the design, thermal analysis, and qualification of the cryogenic system.
△ Less
Submitted 13 June, 2011;
originally announced June 2011.
-
Modeling and characterization of the SPIDER half-wave plate
Authors:
Sean A. Bryan,
Peter A. R. Ade,
Mandana Amiri,
Steve Benton,
Richard Bihary,
James J. Bock,
J. Richard Bond,
Joseph A. Bonetti,
H. Cynthia Chiang,
Carlo R. Contaldi,
Brendan P. Crill,
Daniel O'Dea,
Olivier Dore,
Marzieh Farhang,
Jeffrey P. Filippini,
Laura Fissel,
Natalie Gandilo,
Sunil Golwala,
Jon E. Gudmundsson,
Matthew Hasselfield,
Mark Halpern,
Kyle R. Helson,
Gene Hilton,
Warren Holmes,
Viktor V. Hristov
, et al. (20 additional authors not shown)
Abstract:
Spider is a balloon-borne array of six telescopes that will observe the Cosmic Microwave Background. The 2624 antenna-coupled bolometers in the instrument will make a polarization map of the CMB with approximately one-half degree resolution at 145 GHz. Polarization modulation is achieved via a cryogenic sapphire half-wave plate (HWP) skyward of the primary optic. We have measured millimeter-wave t…
▽ More
Spider is a balloon-borne array of six telescopes that will observe the Cosmic Microwave Background. The 2624 antenna-coupled bolometers in the instrument will make a polarization map of the CMB with approximately one-half degree resolution at 145 GHz. Polarization modulation is achieved via a cryogenic sapphire half-wave plate (HWP) skyward of the primary optic. We have measured millimeter-wave transmission spectra of the sapphire at room and cryogenic temperatures. The spectra are consistent with our physical optics model, and the data gives excellent measurements of the indices of A-cut sapphire. We have also taken preliminary spectra of the integrated HWP, optical system, and detectors in the prototype Spider receiver. We calculate the variation in response of the HWP between observing the CMB and foreground spectra, and estimate that it should not limit the Spider constraints on inflation.
△ Less
Submitted 19 June, 2010;
originally announced June 2010.