All-mirror wavefront division interferometer for mid-infrared spectrometry
Authors:
Ivan Zorin,
Paul Gattinger,
Giovanna Ricchiuti,
Bernhard Lendl,
Bettina Heise,
Markus Brandstetter
Abstract:
In this contribution, we address the core of any Fourier transform (FT) spectrometer$\unicode{x2013}$the interferometer$\unicode{x2013}$in perspective of the recent emergence of spatially coherent broadband infrared (IR) sources. As a result, we report on the design of a wavefront-division interferometer for spectroscopic applications in the mid-IR and beyond. The theoretical framework of the prop…
▽ More
In this contribution, we address the core of any Fourier transform (FT) spectrometer$\unicode{x2013}$the interferometer$\unicode{x2013}$in perspective of the recent emergence of spatially coherent broadband infrared (IR) sources. As a result, we report on the design of a wavefront-division interferometer for spectroscopic applications in the mid-IR and beyond. The theoretical framework of the proposed wavefront division interferometer is discussed, and an analytical solution to determine the far-field interference pattern is derived. The solution is verified by both optical propagation simulations and experimentally. In view of the practical significance, we apply the wavefront division interferometer for FTIR spectroscopy. It features a simple architecture, ultra-broad achromaticity (limited only by the spectral profiles of the mirrors), high optical throughput, variable arms split ratio, and a two-fold increase in scan length and spectral resolution (demonstrated up to 0.2 $cm^{-1}$), respectively. Further, the employed design inherently enables the measurement of the complex refractive index. Experimental verification of the mentioned properties is provided by coupling the spectrometer with a mid-IR supercontinuum source for various applied spectroscopic studies: high-resolution transmission measurements of polymers (polypropylene) and gas (methane), as well as reflectance measurements of dried pharmaceuticals (insulin products on a metal surface).
△ Less
Submitted 28 May, 2024;
originally announced May 2024.
-
Time-encoded mid-infrared Fourier-domain optical coherence tomography
Authors:
Ivan Zorin,
Paul Gattinger,
Andrii Prylepa,
Bettina Heise
Abstract:
We report on a technically simple approach to achieve high-resolution and high-sensitivity Fourier-domain OCT imaging in the mid-infrared range. The proposed OCT system employs an InF3 supercontinuum source. A specially designed dispersive scanning spectrometer based on a single InAsSb point detector is employed for detection. The spectrometer enables structural OCT imaging in the spectral range f…
▽ More
We report on a technically simple approach to achieve high-resolution and high-sensitivity Fourier-domain OCT imaging in the mid-infrared range. The proposed OCT system employs an InF3 supercontinuum source. A specially designed dispersive scanning spectrometer based on a single InAsSb point detector is employed for detection. The spectrometer enables structural OCT imaging in the spectral range from 3140 nm to 4190 nm with a characteristic sensitivity of over 80 dB and an axial resolution below 8 um. The capabilities of the system are demonstrated for imaging of porous ceramic samples and transition-stage green parts fabricated using an emerging method of lithography-based ceramic manufacturing. Additionally, we demonstrate the performance and flexibility of the system by OCT imaging using an inexpensive low-power (average power of 16 mW above 3 um wavelength) mid-IR supercontinuum source.
△ Less
Submitted 14 September, 2021; v1 submitted 11 May, 2021;
originally announced May 2021.
-
Frequency-domain optical coherence tomography with undetected mid-infrared photons
Authors:
Aron Vanselow,
Paul Kaufmann,
Ivan Zorin,
Bettina Heise,
Helen M. Chrzanowski,
Sven Ramelow
Abstract:
Mid-infrared light scatters much less than shorter wavelengths, allowing greatly enhanced penetration depths for optical imaging techniques such as optical coherence tomography (OCT). However, both detection and broadband sources in the mid-IR are technologically challenging. Interfering entangled photons in a nonlinear interferometer enables sensing with undetected photons making mid-IR sources a…
▽ More
Mid-infrared light scatters much less than shorter wavelengths, allowing greatly enhanced penetration depths for optical imaging techniques such as optical coherence tomography (OCT). However, both detection and broadband sources in the mid-IR are technologically challenging. Interfering entangled photons in a nonlinear interferometer enables sensing with undetected photons making mid-IR sources and detectors obsolete. Here we implement mid-infrared frequency-domain OCT based on ultra-broadband entangled photon pairs. We demonstrate 10 $μ$m axial and 20 $μ$m lateral resolution 2D and 3D imaging of strongly scattering ceramic and paint samples. Together with $10^6$ times less noise scaled for the same amount of probe light and also vastly reduced footprint and technical complexity this technique can outperform conventional approaches with classical mid-IR light.
△ Less
Submitted 12 June, 2020;
originally announced June 2020.
-
Correlative infrared optical coherence tomography and hyperspectral chemical imaging
Authors:
Ivan Zorin,
Rong Su,
Bettina Heise,
Bernhard Lendl,
Markus Brandstetter
Abstract:
Optical coherence tomography (OCT) is a high-resolution three-dimensional imaging technique that enables non-destructive measurements of surface and subsurface microstructures. Recent developments of OCT operating in the mid-infrared (MIR) range (around 4 μm) lifted fundamental scattering limitations and initiated applied material research in formerly inaccessible fields. The MIR spectral region,…
▽ More
Optical coherence tomography (OCT) is a high-resolution three-dimensional imaging technique that enables non-destructive measurements of surface and subsurface microstructures. Recent developments of OCT operating in the mid-infrared (MIR) range (around 4 μm) lifted fundamental scattering limitations and initiated applied material research in formerly inaccessible fields. The MIR spectral region, however, is also of great interest for spectroscopy and hyperspectral imaging, which allow highly selective and sensitive chemical studies of materials. In this contribution, we introduce an OCT system (dual-band, central wavelengths of 2 μm m and 4 μm) combined with MIR spectroscopy that is implemented as a raster scanning chemical imaging modality. The fully-integrated and cost-effective optical instrument is based on a single supercontinuum laser source (emission spectrum spanning from 1.1 μm to 4.4 μm). Capabilities of the in-situ correlative measurements are experimentally demonstrated by obtaining complex multidimensional material data, comprising morphological and chemical information, from a multi-layered composite ceramic-polymer specimen.
△ Less
Submitted 5 June, 2020;
originally announced June 2020.
-
Sensitivity-enhanced Fourier transform mid-infrared spectroscopy using a supercontinuum laser source
Authors:
Ivan Zorin,
Jakob Kilgus,
Kristina Duswald,
Bernhard Lendl,
Bettina Heise,
Markus Brandstetter
Abstract:
Fourier transform infrared (FTIR) spectrometers have been the dominant technology in the field of mid-infrared (MIR)spectroscopy for decades. Supercontinuum laser sources operating in the MIR spectral region now offer the potential to enrich the field of FTIR spectroscopy due to their distinctive properties, such as high-brightness, broadband spectral coverage and enhanced stability. In our contri…
▽ More
Fourier transform infrared (FTIR) spectrometers have been the dominant technology in the field of mid-infrared (MIR)spectroscopy for decades. Supercontinuum laser sources operating in the MIR spectral region now offer the potential to enrich the field of FTIR spectroscopy due to their distinctive properties, such as high-brightness, broadband spectral coverage and enhanced stability. In our contribution, we introduce this advanced light source as a replacement for conventional thermal emitters. Furthermore, an approach to efficient coupling of pulsed MIR supercontinuum sources to FTIR spectrometers is proposed and considered in detail. The experimental part is devoted to pulse-to-pulse energy fluctuations of the applied supercontinuum laser, performance of the system, as well as the noise and long-term stability. Comparative measurements performed with a conventional FTIR instrument equipped with a thermal emitter illustrate that similar noise levels can be achieved with the supercontinuum-based system. The analytical performance of the supercontinuum-based FTIR spectrometer was tested for a concentration series of aqueous formaldehyde solutions in a liquid flow cell (500 $μ$m path length) and compared with the conventional FTIR (130 $μ$m path length). The results show a four-times-enhanced detection limit due to the extended path length enabled by the high brightness of the laser. In conclusion, FTIR spectrometers equipped with novel broadband MIR supercontinuum lasers could outperform traditional systems providing superior performance, e.g., interaction path lengths formerly unattainable, while maintaining low noise levels known from highly stable thermal emitters.
△ Less
Submitted 16 April, 2020; v1 submitted 26 February, 2020;
originally announced March 2020.
-
Quantitative phase reconstruction for orthogonal-scanning differential phase-contrast optical coherence tomography
Authors:
Bettina Heise,
David Stifter
Abstract:
We present differential phase-contrast optical coherence tomography (DPC-OCT) with two transversally separated probing beams to sense phase gradients in various directions by employing a rotatable Wollaston prism. In combination with a two-dimensional mathe- matical reconstruction algorithm based on a regularized shape from shading (SfS) method accurate quantitative phase maps can be determined fr…
▽ More
We present differential phase-contrast optical coherence tomography (DPC-OCT) with two transversally separated probing beams to sense phase gradients in various directions by employing a rotatable Wollaston prism. In combination with a two-dimensional mathe- matical reconstruction algorithm based on a regularized shape from shading (SfS) method accurate quantitative phase maps can be determined from a set of two orthogonal en-face DPC-OCT images, as exemplified on various technical samples.
△ Less
Submitted 10 November, 2011;
originally announced November 2011.
-
Spatially resolved stress measurements in materials with polarization-sensitive optical coherence tomography: image acquisition and processing aspects
Authors:
Bettina Heise,
Karin Wiesauer,
Erich Götzinger,
Michael Pircher,
Christoph K. Hitzenberger,
Rainer Engelke,
Gisela Ahrens,
Gabi Grützner,
David Stifter
Abstract:
We demonstrate that polarization-sensitive optical coherence tomography (PS-OCT) is suitable to map the stress distribution within materials in a contactless and non-destructive way. In contrast to transmission photoelasticity measurements the samples do not have to be transparent but can be of scattering nature. Denoising and analysis of fringe patterns in single PS-OCT retardation images are dem…
▽ More
We demonstrate that polarization-sensitive optical coherence tomography (PS-OCT) is suitable to map the stress distribution within materials in a contactless and non-destructive way. In contrast to transmission photoelasticity measurements the samples do not have to be transparent but can be of scattering nature. Denoising and analysis of fringe patterns in single PS-OCT retardation images are demonstrated to deliver the basis for a quantitative whole-field evaluation of the internal stress state of samples under investigation.
△ Less
Submitted 8 November, 2011;
originally announced November 2011.