-
Transmission grating arrays for the X-ray spectrometer on Arcus Probe
Authors:
Ralf K. Heilmann,
Alexander R. Bruccoleri,
James A. Gregory,
Eric M. Gullikson,
Hans Moritz Günther,
Edward Hertz,
Renee D. Lambert,
Douglas J. Young,
Mark L. Schattenburg
Abstract:
The Arcus Probe mission concept has been submitted as an Astrophysics Probe Explorer candidate. It features two co-aligned high-resolution grating spectrometers: one for the soft x-ray band and one for the far UV. Together, these instruments can provide unprecedented performance to address important key questions about the structure and dynamics of our universe across a large range of length scale…
▽ More
The Arcus Probe mission concept has been submitted as an Astrophysics Probe Explorer candidate. It features two co-aligned high-resolution grating spectrometers: one for the soft x-ray band and one for the far UV. Together, these instruments can provide unprecedented performance to address important key questions about the structure and dynamics of our universe across a large range of length scales. The X-ray Spectrometer (XRS) consists of four parallel optical channels, each featuring an x-ray telescope with a fixed array of 216 lightweight, high-efficiency blazed transmission gratings, and two CCD readout arrays. Average spectral resolving power $λ/Δλ> 2,500$ ($\sim 3500$ expected) across the 12-50 Å\ band and combined effective area $> 350$ cm$^2$ ($> 470$ cm$^2$ expected) near OVII wavelengths are predicted, based on the measured x-ray performance of spectrometer prototypes and detailed ray trace modeling. We describe the optical and structural design of the grating arrays, from the macroscopic grating petals to the nanoscale gratings bars, grating fabrication, alignment, and x-ray testing. Recent x-ray diffraction efficiency results from chemically thinned grating bars are presented and show performance above mission assumptions.
△ Less
Submitted 24 May, 2024;
originally announced May 2024.
-
Arcus X-ray telescope performance and alignment
Authors:
Hans Moritz Günther,
Peter Cheimets,
Eric D. Miller,
Casey DeRoo,
Randall K. Smith,
Andrew Ptak,
Ralf K. Heilmann
Abstract:
Arcus is a concept for a probe class mission to deliver high-resolution FUV and X-ray spectroscopy. For X-rays, it combines cost-effective silicon pore optics (SPO) with high-throughput critical-angle transmission (CAT) gratings to achieve $R> 3000$ in a bandpass from 12-50 Angstroem. We show in detail how the X-ray and the UV spectrographs (XRS and UVS) on Arcus will be aligned to each other. For…
▽ More
Arcus is a concept for a probe class mission to deliver high-resolution FUV and X-ray spectroscopy. For X-rays, it combines cost-effective silicon pore optics (SPO) with high-throughput critical-angle transmission (CAT) gratings to achieve $R> 3000$ in a bandpass from 12-50 Angstroem. We show in detail how the X-ray and the UV spectrographs (XRS and UVS) on Arcus will be aligned to each other. For XRS we present ray-tracing studies to derive performance characteristics such as the spectral resolving power and effective area, study the effect of misalignments on the performance, and conclude that most tolerances can be achieved with mechanical means alone. We also present an estimate of the expected on-orbit background.
△ Less
Submitted 28 September, 2023;
originally announced September 2023.
-
The First Flight of the Marshall Grazing Incidence X-ray Spectrometer (MaGIXS)
Authors:
Sabrina L. Savage,
Amy R. Winebarger,
Ken Kobayashi,
P. S. Athiray,
Dyana Beabout,
Leon Golub,
Robert W. Walsh,
Brent Beabout,
Stephen Bradshaw,
Alexander R. Bruccoleri,
Patrick R. Champey,
Peter Cheimets,
Jonathan Cirtain,
Edward DeLuca,
Giulio Del Zanna,
Anthony Guillory,
Harlan Haight,
Ralf K. Heilmann,
Edward Hertz,
William Hogue,
Jeffery Kegley,
Jeffery Kolodziejczak,
Chad Madsen,
Helen Mason,
David E. McKenzie
, et al. (12 additional authors not shown)
Abstract:
The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) sounding rocket experiment launched on July 30, 2021 from the White Sands Missile Range in New Mexico. MaGIXS is a unique solar observing telescope developed to capture X-ray spectral images, in the 6 - 24 Angstrom wavelength range, of coronal active regions. Its novel design takes advantage of recent technological advances related to fabr…
▽ More
The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) sounding rocket experiment launched on July 30, 2021 from the White Sands Missile Range in New Mexico. MaGIXS is a unique solar observing telescope developed to capture X-ray spectral images, in the 6 - 24 Angstrom wavelength range, of coronal active regions. Its novel design takes advantage of recent technological advances related to fabricating and optimizing X-ray optical systems as well as breakthroughs in inversion methodologies necessary to create spectrally pure maps from overlap** spectral images. MaGIXS is the first instrument of its kind to provide spatially resolved soft X-ray spectra across a wide field of view. The plasma diagnostics available in this spectral regime make this instrument a powerful tool for probing solar coronal heating. This paper presents details from the first MaGIXS flight, the captured observations, the data processing and inversion techniques, and the first science results.
△ Less
Submitted 7 December, 2022; v1 submitted 1 December, 2022;
originally announced December 2022.
-
X-ray performance of critical-angle transmission grating prototypes for the Arcus mission
Authors:
Ralf K. Heilmann,
Alexander R. Bruccoleri,
Vadim Burwitz,
Casey deRoo,
Alan Garner,
Hans Moritz Guenther,
Eric M. Gullikson,
Gisela Hartner,
Ed Hertz,
Andreas Langmeier,
Thomas Mueller,
Surangkhana Rukdee,
Thomas Schmidt,
Randall K. Smith,
Mark L. Schattenburg
Abstract:
Arcus is a proposed soft x-ray grating spectrometer Explorer. It aims to explore cosmic feedback by map** hot gases within and between galaxies and galaxy clusters and characterizing jets and winds from supermassive black holes, and to investigate the dynamics of protoplanetary discs and stellar accretion. Arcus features 12 m-focal-length grazing-incidence silicon pore optics (SPO) developed for…
▽ More
Arcus is a proposed soft x-ray grating spectrometer Explorer. It aims to explore cosmic feedback by map** hot gases within and between galaxies and galaxy clusters and characterizing jets and winds from supermassive black holes, and to investigate the dynamics of protoplanetary discs and stellar accretion. Arcus features 12 m-focal-length grazing-incidence silicon pore optics (SPO) developed for the Athena mission. Critical-angle transmission (CAT) gratings efficiently disperse high diffraction orders onto CCDs. We report new and improved x-ray performance results for Arcus-like CAT gratings, including record resolving power for two co-aligned CAT gratings. Multiple Arcus prototype grating facets were illuminated by an SPO at the PANTER facility. The facets consist of $32\times32.5$ mm$^2$ patterned silicon membranes, bonded to metal frames. The bonding angle is adjusted according to the measured average tilt angle of the grating bars in the membrane. Two simultaneously illuminated facets show minor broadening of the Al-K$_α$ doublet in 18$^{\rm th}$ and 21$^{\rm st}$ orders with a best fit record effective resolving power of $R_G \approx 1.3^{+\infty}_{-0.5}\times10^4$ ($3σ$), about 3-4 times the Arcus requirement. We measured the diffraction efficiency of quasi-fully illuminated gratings at O-K wavelengths in orders 4-7 in an Arcus-like configuration and compare results with synchrotron spot measurements. After corrections for geometrical effects and bremsstrahlung continuum we find agreement between full and spot illumination at the two different facilities, as well as with the models used for Arcus effective area predictions. We find that these flight-like gratings meet diffraction efficiency and greatly exceed resolving power Arcus requirements.
△ Less
Submitted 17 June, 2022;
originally announced June 2022.
-
Calibration of the MaGIXS experiment II: Flight Instrument Calibration
Authors:
P. S. Athiray,
Amy R. Winebarger,
Patrick Champey,
Ken Kobayashi,
Sabrina Savage,
Brent Beabout,
Dyana Beabout,
David Broadway,
Alexander R. Bruccoleri,
Peter Cheimets,
Leon Golub,
Eric Gullikson,
Harlan Haight,
Ralf K. Heilmann,
Edward Hertz,
William Hogue,
Steven Johnson,
Jeffrey Kegley,
Jeffery Kolodziejczak,
Chad Madsen,
Mark L. Schattenburg,
Richard Siler,
Genevieve D. Vigil,
Ernest Wright
Abstract:
The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a sounding rocket experiment that observes the soft X-ray spectrum of the Sun from 6.0 - 24 Angstrom (0.5 - 2.0 keV), successfully launched on 30 July 2021. End-to-end alignment of the flight instrument and calibration experiments are carried out using the X-ray and Cryogenic Facility (XRCF) at NASA Marshall Space Flight Center. In this…
▽ More
The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a sounding rocket experiment that observes the soft X-ray spectrum of the Sun from 6.0 - 24 Angstrom (0.5 - 2.0 keV), successfully launched on 30 July 2021. End-to-end alignment of the flight instrument and calibration experiments are carried out using the X-ray and Cryogenic Facility (XRCF) at NASA Marshall Space Flight Center. In this paper, we present the calibration experiments of MaGIXS, which include wavelength calibration, measurement of line spread function, and determination of effective area. Finally, we use the measured instrument response function to predict the expected count rates for MaGIXS flight observation looking at a typical solar active region
△ Less
Submitted 3 September, 2021;
originally announced September 2021.
-
Toward volume manufacturing of high-performance soft x-ray critical-angle transmission gratings
Authors:
Ralf K. Heilmann,
Alexander R. Bruccoleri,
Jungki Song,
Matthew T. Cook,
James A. Gregory,
Renee D. Lambert,
Dimitri A. Shapiro,
Douglas J. Young,
Miranda Bradshaw,
Vadim Burwitz,
Gisela D. Hartner,
Andreas Langmeier,
Randall K. Smith,
Mark L. Schattenburg
Abstract:
High-resolution ($R = λ/Δλ> 2000$) x-ray absorption and emission line spectroscopy in the soft x-ray band is a crucial diagnostic for the exploration of the properties of ubiquitous warm and hot plasmas and their dynamics in the cosmic web, galaxy clusters, galaxy halos, intragalactic space, and star atmospheres. Soft x-ray grating spectroscopy with $R > 10{,}000$ has been demonstrated with critic…
▽ More
High-resolution ($R = λ/Δλ> 2000$) x-ray absorption and emission line spectroscopy in the soft x-ray band is a crucial diagnostic for the exploration of the properties of ubiquitous warm and hot plasmas and their dynamics in the cosmic web, galaxy clusters, galaxy halos, intragalactic space, and star atmospheres. Soft x-ray grating spectroscopy with $R > 10{,}000$ has been demonstrated with critical-angle transmission (CAT) gratings. CAT gratings combine the relaxed alignment and temperature tolerances and low mass of transmission gratings with high diffraction efficiency blazed in high orders. They are an enabling technology for the proposed Arcus grating explorer and were selected for the Lynx design reference mission grating spectrometer instrument. Both Arcus and Lynx require the manufacture of hundreds to perhaps $\approx 2000$ large-area CAT gratings. We are develo** new patterning and fabrication process sequences that are conducive to large-format volume processing on state-of-the-art 200 mm wafer tools. Recent x-ray tests on 200 nm-period gratings patterned using e-beam-written masks and 4x projection lithography in conjunction with silicon pore focusing optics demonstrated $R \approx 10^4$ at 1.49 keV. Extending the grating depth from 4 $μ$m to 6 $μ$m is predicted to lead to significant improvements in diffraction efficiency and is part of our current efforts using a combination of deep reactive-ion etching and wet etching in KOH solution. We describe our recent progress in grating fabrication and report our latest diffraction efficiency and modeling results.
△ Less
Submitted 8 December, 2020;
originally announced December 2020.
-
A Small Satellite Version of a Broad-band Soft X-ray Polarimeter
Authors:
Herman L. Marshall,
Sarah N. T. Heine,
Alan Garner,
Eric M. Gullikson,
H. Moritz Günther,
Christopher Leitz,
Rebecca Masterson,
Eric D. Miller,
William Zhang,
Rozenn Boissay-Malaquin,
Ilaria Caiazzo,
Deepto Chakrabarty,
Rosemary Davidson,
Luigi C. Gallo,
Ralf K. Heilmann,
Jeremy Heyl,
Erin Kara,
Alan Marscher,
Norbert S. Schulz
Abstract:
We describe a new implementation of a broad-band soft X-ray polarimeter, substantially based on a previous design. This implementation, the Pioneer Soft X-ray Polarimeter (PiSoX) is a SmallSat, designed for NASA's call for Astrophysics Pioneers, small missions that could be CubeSats, balloon experiments, or SmallSats. As in the REDSoX Polarimeter, the grating arrangement is designed optimally for…
▽ More
We describe a new implementation of a broad-band soft X-ray polarimeter, substantially based on a previous design. This implementation, the Pioneer Soft X-ray Polarimeter (PiSoX) is a SmallSat, designed for NASA's call for Astrophysics Pioneers, small missions that could be CubeSats, balloon experiments, or SmallSats. As in the REDSoX Polarimeter, the grating arrangement is designed optimally for the purpose of polarimetry with broad-band focussing optics by matching the dispersion of the spectrometer channels to laterally graded multilayers (LGMLs). The system can achieve polarization modulation factors over 90%. For PiSoX, the optics are lightweight Si mirrors in a one-bounce parabolic configuration. High efficiency, blazed gratings from opposite sectors are oriented to disperse to a LGML forming a channel covering the wavelength range from 35 to 75 Angstroms (165 - 350 eV). Upon satellite rotation, the intensities of the dispersed spectra, after reflection and polarizing by the LGMLs, give the three Stokes parameters needed to determine a source's linear polarization fraction and orientation. The design can be extended to higher energies as LGMLs are developed further. We describe examples of the potential scientific return from instruments based on this design.
△ Less
Submitted 4 December, 2020;
originally announced December 2020.
-
Lynx grating spectrometer design: Optimizing chirped transmission gratings
Authors:
Hans Moritz Günther,
Ralf K. Heilmann
Abstract:
Lynx is one of four large-mission concept studies for NASA's 2020 Decadal survey. The design reference mission includes an X-ray grating spectrometer (XGS) based on critical-angle transmission (CAT) gratings. In the past we studied different grating sizes and arrangements using traditional flat CAT gratings with constant bar spacing. However, new technology development brings chirped gratings in r…
▽ More
Lynx is one of four large-mission concept studies for NASA's 2020 Decadal survey. The design reference mission includes an X-ray grating spectrometer (XGS) based on critical-angle transmission (CAT) gratings. In the past we studied different grating sizes and arrangements using traditional flat CAT gratings with constant bar spacing. However, new technology development brings chirped gratings in reach. Using chirped gratings where the grating bar spacing varies over a grating allows us to fill the aperture with larger gratings because the chirp can compensate for some aberrations caused by the deviation of large flat gratings from the Rowland torus. This reduces the area blocked by grating support structures. Using larger gratings also carries potential cost savings. We use ray-tracing to study an XGS design with chirped grating and find that using chirped gratings of $80 * 160$ mm size allows us to reduce the number of gratings from a few thousand to a few hundred, while simultaneously increasing the effective area by 25% and kee** the resolving power constant. Bending those gratings to maintain a constant blaze angle over the entire grating increases the effective area by another 5-10%.
△ Less
Submitted 30 November, 2020;
originally announced November 2020.
-
Optical design of diffraction-limited X-ray telescopes
Authors:
Brandon D. Chalifoux,
Ralf K. Heilmann,
Herman L. Marshall,
Mark L. Schattenburg
Abstract:
Astronomical imaging with micro-arcsecond ($μ$as) angular resolution could enable breakthrough scientific discoveries. Previously-proposed $μ$as X-ray imager designs have been interferometers with limited effective collecting area. Here we describe X-ray telescopes achieving diffraction-limited performance over a wide energy band with large effective area, employing a nested-shell architecture wit…
▽ More
Astronomical imaging with micro-arcsecond ($μ$as) angular resolution could enable breakthrough scientific discoveries. Previously-proposed $μ$as X-ray imager designs have been interferometers with limited effective collecting area. Here we describe X-ray telescopes achieving diffraction-limited performance over a wide energy band with large effective area, employing a nested-shell architecture with grazing-incidence mirrors, while matching the optical path lengths between all shells. We present two compact nested-shell Wolter Type 2 grazing-incidence telescope designs for diffraction-limited X-ray imaging: a micro-arcsecond telescope design with 14 $μ$as angular resolution and 2.9 m$^2$ of effective area at 5 keV photon energy ($λ$=0.25 nm), and a smaller milli-arcsecond telescope design with 525 $μ$as resolution and 645 cm$^2$ effective area at 1 keV ($λ$=1.24 nm). We describe how to match the optical path lengths between all shells in a compact mirror assembly, and investigate chromatic and off-axis aberrations. Chromatic aberration results from total external reflection off of mirror surfaces, and we greatly mitigate its effects by slightly adjusting the path lengths in each mirror shell. The mirror surface height error and alignment requirements for diffraction-limited performance are challenging but arguably achieveable in the coming decades. Since the focal ratio for a diffraction-limited X-ray telescope is extremely large ($f/D$~10$^5$), the only important off-axis aberration is curvature of field, so a 1 arcsecond field of view is feasible with a flat detector. The detector must fly in formation with the mirror assembly, but relative positioning tolerances are on the order of 1 m over a distance of some tens to hundreds of kilometers. While there are many challenges to achieving diffraction-limited X-ray imaging, we did not find any fundamental barriers.
△ Less
Submitted 24 April, 2020;
originally announced April 2020.
-
Demonstration of resolving power $λ/Δλ> 10,000$ for a space-based x-ray transmission grating spectrometer
Authors:
Ralf K. Heilmann,
Jeffery Kolodziejczak,
Alexander R. Bruccoleri,
Jessica A. Gaskin,
Mark L. Schattenburg
Abstract:
We present measurements of the resolving power of a soft x-ray spectrometer consisting of 200 nm-period lightweight, alignment-insensitive critical-angle transmission (CAT) gratings and a lightweight slumped-glass Wolter-I focusing mirror pair. We measure and model contributions from source, mirrors, detector pixel size, and grating period variation to the natural line width spectrum of the Al and…
▽ More
We present measurements of the resolving power of a soft x-ray spectrometer consisting of 200 nm-period lightweight, alignment-insensitive critical-angle transmission (CAT) gratings and a lightweight slumped-glass Wolter-I focusing mirror pair. We measure and model contributions from source, mirrors, detector pixel size, and grating period variation to the natural line width spectrum of the Al and Mg K$_{α_1 α_2}$ doublets. Measuring up to 18$^{\rm th}$ diffraction order at characteristic Al-K wavelengths we consistently obtain small broadening due to gratings corresponding to a minimum effective grating resolving power $R_g > 10,000$ with 90\% confidence. Upper limits are often compatible with $R_g = \infty$. Independent fitting of different diffraction orders, as well as ensemble fitting of multiple orders at multiple wavelengths, gives compatible results. Our data leads to uncertainties for the Al-K$_α$ doublet line width and line separation parameters 2-3 times smaller than values found in the literature. Data from three different gratings are mutually compatible. This demonstrates that CAT gratings perform in excess of the requirements for the Arcus Explorer mission and are suitable for next-generation space-based x-ray spectrometer designs with resolving power 5-10 times higher than the transmission grating spectrometer on the Chandra X-ray Observatory.
△ Less
Submitted 19 December, 2018;
originally announced December 2018.
-
Critical-angle x-ray transmission grating spectrometer with extended bandpass and resolving power > 10,000
Authors:
Ralf K. Heilmann,
Alexander R. Bruccoleri,
Jeffery Kolodziejczak,
Jessica A. Gaskin,
Stephen L. O'Dell,
Ritwik Bhatia,
Mark L. Schattenburg
Abstract:
Several high priority subjects in astrophysics can be addressed by a state-of-the-art soft x-ray grating spectrometer (XGS). An Explorer-scale, large-area (> 1,000 cm2), high resolving power (R > 3,000) XGS is highly feasible based on Critical-Angle Transmission (CAT) gratings, even for telescopes with angular resolution of 5-10 arcsec. Significantly higher performance can be provided by a CAT XGS…
▽ More
Several high priority subjects in astrophysics can be addressed by a state-of-the-art soft x-ray grating spectrometer (XGS). An Explorer-scale, large-area (> 1,000 cm2), high resolving power (R > 3,000) XGS is highly feasible based on Critical-Angle Transmission (CAT) gratings, even for telescopes with angular resolution of 5-10 arcsec. Significantly higher performance can be provided by a CAT XGS on an X-ray-Surveyor-type mission. CAT gratings combine the advantages of blazed reflection gratings (high efficiency, use of higher diffraction orders) with those of transmission gratings (low mass, relaxed alignment and temperature requirements, transparent at high energies) with minimal mission resource demands. They are high-efficiency blazed transmission gratings that consist of freestanding, ultra-high aspect-ratio grating bars made from SOI wafers using anisotropic dry and wet etch techniques. Blazing is achieved through reflection off grating bar sidewalls. Silicon is well matched to the soft x-ray band, and existing silicon CAT gratings exceed 30% absolute diffraction efficiency, with clear paths for improvement. CAT gratings coated with heavier elements allow extension of the CAT grating principle to higher energies and larger angles, enabling higher resolving power at shorter wavelengths. We show x-ray data from CAT gratings coated with platinum using atomic layer deposition, and demonstrate blazing to higher energies and much larger blaze angles than possible with silicon. We measure resolving power of a CAT XGS consisting of a Wolter-I focusing mirror pair from GSFC and CAT gratings, performed at the MSFC SLF. Measurement of the Al Ka doublet in 18th order shows resolving power > 10,000, based on preliminary analysis. This demonstrates that currently fabricated CAT gratings are compatible with the most advanced XGS designs for future soft x-ray spectroscopy missions.
△ Less
Submitted 15 July, 2016;
originally announced July 2016.
-
Rotationally symmetric ordered phase in the three-state antiferromagnetic Potts model
Authors:
Ralf K. Heilmann,
Jian-Sheng Wang,
Robert H. Swendsen
Abstract:
We investigate the three-state antiferromagnetic Potts model on a simple cubic lattice with a cluster flip** Monte Carlo simulation algorithm in the temperature region below the transition into disorder at T_{c1}. We find both the well established broken-sublattice-symmetry (BSS) phase at low temperature and a new, rotationally symmetric phase at higher temperature, but below T_{c1}. The prope…
▽ More
We investigate the three-state antiferromagnetic Potts model on a simple cubic lattice with a cluster flip** Monte Carlo simulation algorithm in the temperature region below the transition into disorder at T_{c1}. We find both the well established broken-sublattice-symmetry (BSS) phase at low temperature and a new, rotationally symmetric phase at higher temperature, but below T_{c1}. The properties of the second phase and the transition temperature to the BSS phase are in disagreement with recent cluster-variation and Monte Carlo simulation results, but in agreement with simulations by Kolesik and Suzuki.
△ Less
Submitted 22 September, 1995;
originally announced September 1995.