Charged Particle Tracking with the Timepix ASIC
Authors:
Kazuyoshi Akiba,
Marina Artuso,
Ryan Badman,
Alessandra Borgia,
Richard Bates,
Florian Bayer,
Martin van Beuzekom,
Jan Buytaert,
Enric Cabruja,
Michael Campbell,
Paula Collins,
Michael Crossley,
Raphael Dumps,
Lars Eklund,
Daniel Esperante,
Celeste Fleta,
Abraham Gallas,
Miriam Gandelman,
Justin Garofoli,
Marco Gersabeck,
Vladimir V. Gligorov,
Hamish Gordon,
Erik H. M. Heijne,
Veerle Heijne,
Daniel Hynds
, et al. (17 additional authors not shown)
Abstract:
A prototype particle tracking telescope has been constructed using Timepix and Medipix ASIC hybrid pixel assemblies as the six sensing planes. Each telescope plane consisted of one 1.4 cm2 assembly, providing a 256x256 array of 55 micron square pixels. The telescope achieved a pointing resolution of 2.3 micron at the position of the device under test. During a beam test in 2009 the telescope was u…
▽ More
A prototype particle tracking telescope has been constructed using Timepix and Medipix ASIC hybrid pixel assemblies as the six sensing planes. Each telescope plane consisted of one 1.4 cm2 assembly, providing a 256x256 array of 55 micron square pixels. The telescope achieved a pointing resolution of 2.3 micron at the position of the device under test. During a beam test in 2009 the telescope was used to evaluate in detail the performance of two Timepix hybrid pixel assemblies; a standard planar 300 micron thick sensor, and 285 micron thick double sided 3D sensor. This paper describes a detailed charge calibration study of the pixel devices, which allows the true charge to be extracted, and reports on measurements of the charge collection characteristics and Landau distributions. The planar sensor achieved a best resolution of 4.0 micron for angled tracks, and resolutions of between 4.4 and 11 micron for perpendicular tracks, depending on the applied bias voltage. The double sided 3D sensor, which has significantly less charge sharing, was found to have an optimal resolution of 9.0 micron for angled tracks, and a resolution of 16.0 micron for perpendicular tracks. Based on these studies it is concluded that the Timepix ASIC shows an excellent performance when used as a device for charged particle tracking.
△ Less
Submitted 14 June, 2011; v1 submitted 14 March, 2011;
originally announced March 2011.
-
The detection of single electrons by means of a Micromegas-covered MediPix2 pixel CMOS readout circuit
Authors:
M. Campbell,
M. Chefdeville,
P. Colas,
A. P. Colijn,
A. Fornaini,
Y. Giomataris,
H. van der Graaf,
E. H. M Heijne,
P. Kluit,
X. Llopart,
J. Schmitz,
J. Timmermans,
J. L. Visschers
Abstract:
A small drift chamber was read out by means of a MediPix2 readout chip as direct anode. A Micromegas foil was placed 50 $μ$m above the chip, and electron multiplication occurred in the gap. With a He/Isobutane 80/20 mixture, gas multiplication factors up to tens of thousands were achieved, resulting in an efficiency for detecting single electrons of better than 90% . We recorded many frames cont…
▽ More
A small drift chamber was read out by means of a MediPix2 readout chip as direct anode. A Micromegas foil was placed 50 $μ$m above the chip, and electron multiplication occurred in the gap. With a He/Isobutane 80/20 mixture, gas multiplication factors up to tens of thousands were achieved, resulting in an efficiency for detecting single electrons of better than 90% . We recorded many frames containing 2D images with tracks from cosmic muons. Along these tracks, electron clusters were observed, as well as delta-rays.
△ Less
Submitted 9 September, 2004;
originally announced September 2004.
-
X-ray Imaging Using a Hybrid Photon Counting GaAs Pixel Detector
Authors:
C. Schwarz,
M. Campbell,
R. Goeppert,
E. H. M. Heijne,
J. Ludwig,
G. Meddeler,
B. Mikulec,
E. Pernigotti,
M. Rogalla,
K. Runge,
A. Soldner-Rembold,
K. M. Smith,
W. Snoeys,
J. Watt
Abstract:
The performance of hybrid GaAs pixel detectors as X-ray imaging sensors were investigated at room temperature. These hybrids consist of 300 mu-m thick GaAs pixel detectors, flip-chip bonded to a CMOS Single Photon Counting Chip (PCC). This chip consists of a matrix of 64 x 64 identical square pixels (170 mu-m x 170 mu-m) and covers a total area of 1.2 cm**2. The electronics in each cell comprise…
▽ More
The performance of hybrid GaAs pixel detectors as X-ray imaging sensors were investigated at room temperature. These hybrids consist of 300 mu-m thick GaAs pixel detectors, flip-chip bonded to a CMOS Single Photon Counting Chip (PCC). This chip consists of a matrix of 64 x 64 identical square pixels (170 mu-m x 170 mu-m) and covers a total area of 1.2 cm**2. The electronics in each cell comprises a preamplifier, a discriminator with a 3-bit threshold adjust and a 15-bit counter. The detector is realized by an array of Schottky diodes processed on semi-insulating LEC-GaAs bulk material. An IV-charcteristic and a detector bias voltage scan showed that the detector can be operated with voltages around 200 V. Images of various objects were taken by using a standard X-ray tube for dental diagnostics. The signal to noise ratio (SNR) was also determined. The applications of these imaging systems range from medical applications like digital mammography or dental X-ray diagnostics to non destructive material testing (NDT). Because of the separation of detector and readout chip, different materials can be investigated and compared.
△ Less
Submitted 21 December, 1998;
originally announced December 1998.