Laboratory demonstration of a cryogenic deformable mirror for wavefront correction of space-borne infrared telescopes
Authors:
Aoi Takahashi,
Keigo Enya,
Kanae Haze,
Hirokazu Kataza,
Takayuki Kotani,
Hideo Matsuhara,
Tomohiro Kamiya,
Tomoyasu Yamamuro,
Paul Bierden,
Steven Cornelissen,
Charlie Lam,
Michael Feinberg
Abstract:
This paper demonstrates a cryogenic deformable mirror (DM) with 1,020 actuators based on micro-electrical mechanical systems (MEMS) technology. Cryogenic space-borne infrared telescopes can experience a wavefront error due to a figure error of their mirror surface, which makes the imaging performance worse. For on-orbit wavefront correction as one solution, we developed a MEMS-processed electro-st…
▽ More
This paper demonstrates a cryogenic deformable mirror (DM) with 1,020 actuators based on micro-electrical mechanical systems (MEMS) technology. Cryogenic space-borne infrared telescopes can experience a wavefront error due to a figure error of their mirror surface, which makes the imaging performance worse. For on-orbit wavefront correction as one solution, we developed a MEMS-processed electro-static DM with a special surrounding structure for use under the cryogenic temperature. We conducted a laboratory demonstration of its operation in three cooling cycles between 5 K and 295 K. Using a laser interferometer, we detected the deformation corresponding to the applied voltages under the cryogenic temperature for the first time. The relationship between voltages and displacements was qualitatively expressed by the quadratic function, which is assumed based on the principle of electro-static DMs. We also found that it had a high operating repeatability of a few nm RMS and no significant hysteresis. Using the measured values of repeatability, we simulated the improvement of PSF by wavefront correction with our DM. These results show that our developed DM is effective in improving imaging performance and PSF contrast of space-borne infrared telescopes.
△ Less
Submitted 29 September, 2017;
originally announced October 2017.
-
Experimental demonstration of binary shaped pupil mask coronagraphs for telescopes with obscured pupils
Authors:
Kanae Haze,
Keigo Enya,
Lyu Abe,
Aoi Takahashi,
Takayuki Kotani,
Tomoyasu Yamamuro
Abstract:
We present the fabrication and experimental demonstration of three free-standing binary shaped pupil mask coronagraphs, which are applicable for telescopes with partially obscured pupils. Three masks, designed to be complementary (labeled Mask-A, Mask-B, and Mask-C), were formed in 5 micron thick nickel. The design of Mask-A is based on a one-dimensional barcode mask. The design principle of Mask-…
▽ More
We present the fabrication and experimental demonstration of three free-standing binary shaped pupil mask coronagraphs, which are applicable for telescopes with partially obscured pupils. Three masks, designed to be complementary (labeled Mask-A, Mask-B, and Mask-C), were formed in 5 micron thick nickel. The design of Mask-A is based on a one-dimensional barcode mask. The design principle of Mask-B is similar, but has a smaller inner working angle and a lower contrast than Mask-A. Mask-C is based on a concentric ring mask and provides the widest dark region and a symmetric point spread function. Mask-A and Mask-C were both designed to produce a flexibly tailored dark region (i.e., non-uniform contrast). The contrast was evaluated using a light source comprising a broadband super-luminescent light-emitting diode with a center wavelength of 650 nm, and the measurements were carried out in a large vacuum chamber. Active wavefront control was not applied in this work. The coronagraphic images obtained by experiment were mostly consistent with the designs. The contrast of Mask-A within the ranges 3.3 - 8 lambda/D and 8 - 12 lambda/D was ~10^{-4} - 10^{-7} and ~10^{-7}, respectively, where lambda is the wavelength and D is the pupil diameter. The contrast close to the center of Mask-B was ~10^{-4} and that of Mask-C over an extended field of view (5 - 25 lambda/D) was ~10^{-5} - 10^{-6}. The effect of tilting the masks was investigated, and found to be irrelevant at the ~10^{-7} contrast level. Therefore the masks can be tilted to avoid ghosting. These high-contrast free-standing masks have the potential to enable coronagraphic imaging over a wide wavelength range using both ground-based and space-borne general-purpose telescopes with pupil structures not specifically designed for coronagraphy.
△ Less
Submitted 30 March, 2016;
originally announced March 2016.
-
Coronagraphic demonstration experiment using aluminum mirrors for space infrared astronomical observations
Authors:
Shinji Oseki,
Shinki Oyabu,
Daisuke Ishihara,
Keigo Enya,
Kanae Haze,
Takayuki Kotani,
Hidehiro Kaneda,
Miho Nishiyama,
Lyu Abe,
Tomoyasu Yamamuro
Abstract:
For future space infrared astronomical coronagraphy, we perform experimental studies on the application of aluminum mirrors to a coronagraph. Cooled reflective optics is required for broad-band mid-infrared observations in space, while high-precision optics is required for coronagraphy. For the coronagraph instrument originally proposed for the next-generation infrared astronomical satellite proje…
▽ More
For future space infrared astronomical coronagraphy, we perform experimental studies on the application of aluminum mirrors to a coronagraph. Cooled reflective optics is required for broad-band mid-infrared observations in space, while high-precision optics is required for coronagraphy. For the coronagraph instrument originally proposed for the next-generation infrared astronomical satellite project SPICA (SCI: SPICA Coronagraph Instrument), we fabricated and evaluated the optics consisting of high-precision aluminum off-axis mirrors with diamond-turned surfaces, and conducted a coronagraphic demonstration experiment using the optics with a coronagraph mask. We first measured the wave front errors (WFEs) of the aluminum mirrors with a He-Ne Fizeau interferometer to confirm that the power spectral densities of the WFEs satisfy the SCI requirements. Then we integrated the mirrors into an optical system and evaluated the overall performance of the system. As a result, we estimate the total WFE of the optics to be 33 nm (rms), each mirror contributing 10-20 nm (rms) for the central 14 mm area of the optics, and obtain a contrast of 10^(-5.4) as a coronagraph in the visible light. At a wavelength of 5 um, the coronagraphic system is expected to achieve a contrast of ~10^(-7) based on our model calculation with the measured optical performance. Thus our experiment demonstrates that aluminum mirror optics is applicable to a highly WFE-sensitive instrument such as a coronagraph in space.
△ Less
Submitted 4 September, 2015;
originally announced September 2015.
-
Comparative study of manufacturing techniques for coronagraphic binary pupil masks: masks on substrates and free-standing masks
Authors:
Keigo Enya,
Kanae Haze,
Takayuki Kotani,
Lyu Abe
Abstract:
We present a comparative study of the manufacture of binary pupil masks for coronagraphic observations of exoplanets. A checkerboard mask design, a type of binary pupil mask design, was adopted, and identical patterns of the same size were used for all the masks in order that we could compare the differences resulting from the different manufacturing methods. The masks on substrates had aluminum c…
▽ More
We present a comparative study of the manufacture of binary pupil masks for coronagraphic observations of exoplanets. A checkerboard mask design, a type of binary pupil mask design, was adopted, and identical patterns of the same size were used for all the masks in order that we could compare the differences resulting from the different manufacturing methods. The masks on substrates had aluminum checkerboard patterns with thicknesses of 0.1/0.2/0.4/0.8/1.6$μ$m constructed on substrates of BK7 glass, silicon, and germanium using photolithography and chemical processes. Free-standing masks made of copper and nickel with thicknesses of 2/5/10/20$μ$m were also realized using photolithography and chemical processes, which included careful release from the substrate used as an intermediate step in the manufacture. Coronagraphic experiments using a visible laser were carried out for all the masks on BK7 glass substrate and the free-standing masks. The average contrasts were 8.4$\times10^{-8}$, 1.2$\times10^{-7}$, and 1.2$\times10^{-7}$ for the masks on BK7 substrates, the free-standing copper masks, and the free-standing nickel masks, respectively. No significant correlation was concluded between the contrast and the mask properties. The high contrast masks have the potential to cover the needs of coronagraphs for both ground-based and space-borne telescopes over a wide wavelength range. Especially, their application to the infrared space telescope, SPICA, is appropriate.
△ Less
Submitted 2 June, 2012;
originally announced June 2012.
-
Development of binary shaped pupil mask coronagraph for the observation of exoplanets
Authors:
Kanae Haze
Abstract:
Direct observation of extra-solar planets (exoplanets) is essential to understand how planetary systems were born, how they evolve, and ultimately, to identify biological signatures on these planets. However, the enormous contrast in flux between the central star and associated planets is the primary difficulty in the direct observation. This has required stellar coronagraphs which can improve the…
▽ More
Direct observation of extra-solar planets (exoplanets) is essential to understand how planetary systems were born, how they evolve, and ultimately, to identify biological signatures on these planets. However, the enormous contrast in flux between the central star and associated planets is the primary difficulty in the direct observation. This has required stellar coronagraphs which can improve the contrast between the star and the planet to be developed. Of the various kinds of coronagraphs, we focused on a binary-shaped pupil mask coronagraph. The reasons for using this coronagraph are robust against pointing errors, essentially achromatic and relatively simple. We conducted a number of coronagraph experiments using a vacuum chamber and a checker-board mask, a kind of binary-shaped pupil mask, without active wavefront control. We demonstrated PSF subtraction is potentially beneficial for improving contrast of a binary-shaped pupil mask coronagraph, this coronagraph produces a significant improvement in contrast with multi-color/broadband light sources, and the new free-standing mask for practical use provides superior performance of improving contrast. We performed the tasks necessary to make the coronagraph fit for practical use. In conclusion, we carried out verification test for more real coronagraphic observations.
△ Less
Submitted 10 January, 2012; v1 submitted 29 December, 2011;
originally announced December 2011.
-
High contrast experiment of an AO-free coronagraph with a checkerboard pupil mask
Authors:
K. Enya,
L. Abe,
S. Tanaka,
T. Nakagawa,
K. Haze,
T. Sato,
T. Wakayama
Abstract:
A high contrast coronagraph is expected to provide one of the promising ways to directly observe extra-solar planets. We present the newest results of our laboratory experiment investigating "rigid" coronagraph with a binary shaped checkerboard pupil mask, which should offer a highly stable solution for telescopes without adaptive optics (AO) for wavefront correction in space missions. The primary…
▽ More
A high contrast coronagraph is expected to provide one of the promising ways to directly observe extra-solar planets. We present the newest results of our laboratory experiment investigating "rigid" coronagraph with a binary shaped checkerboard pupil mask, which should offer a highly stable solution for telescopes without adaptive optics (AO) for wavefront correction in space missions. The primary aim of this work was to study the stability of the coronagraph, and to demonstrate its performance without adaptive wavefront correction. Estimation of both the raw contrast and the gain of the point spread function (PSF) subtraction were needed. The limiting factor of the contrast was also important. A binary shaped pupil mask of a checkerboard type has been designed. The mask, consisting of an aluminum film on a glass substrate, was manufactured using nano-fabrication techniques with electron beam lithography. Careful evaluation of coronagraphic performance, including PSF subtraction, was carried out in air using the developed mask. A contrast of $6.7 \times 10^{-8}$ was achieved for the raw coronagraphic image by areal averaging of all of the observed dark regions. Following PSF subtraction, the contrast reached $6.8 \times 10^{-9}$. Speckles were a major limiting factor throughout the dark regions of both the raw image and the PSF subtracted image. A rigid coronagraph with PSF subtraction without AO is a useful method to achieve high contrast observations. Applications of a rigid coronagraph to a Space Infrared telescope for Cosmology and Astrophysics (SPICA) and other platforms are discussed.
△ Less
Submitted 16 August, 2011;
originally announced August 2011.
-
The SPICA coronagraphic instrument (SCI) for the study of exoplanets
Authors:
K. Enya,
T. Kotani,
K. Haze,
K. Aono,
T. Nakagawa,
H. Matsuhara,
H. Kataza,
T. Wada,
M. Kawada,
K. Fujiwara,
M. Mita,
S. Takeuchi,
K. Komatsu,
S. Sakai,
H. Uchida,
S. Mitani,
T. Yamawaki,
T. Miyata,
S. Sako,
T. Nakamura,
K. Asano,
T. Yamashita,
N. Narita,
T. Matsuo,
M. Tamura
, et al. (17 additional authors not shown)
Abstract:
We present the SPICA Coronagraphic Instrument (SCI), which has been designed for a concentrated study of extra-solar planets (exoplanets). SPICA mission provides us with a unique opportunity to make high contrast observations because of its large telescope aperture, the simple pupil shape, and the capability for making infrared observations from space. The primary objectives for the SCI are the di…
▽ More
We present the SPICA Coronagraphic Instrument (SCI), which has been designed for a concentrated study of extra-solar planets (exoplanets). SPICA mission provides us with a unique opportunity to make high contrast observations because of its large telescope aperture, the simple pupil shape, and the capability for making infrared observations from space. The primary objectives for the SCI are the direct coronagraphic detection and spectroscopy of Jovian exoplanets in infrared, while the monitoring of transiting planets is another important target. The specification and an overview of the design of the instrument are shown. In the SCI, coronagraphic and non-coronagraphic modes are applicable for both an imaging and a spectroscopy. The core wavelength range and the goal contrast of the coronagraphic mode are 3.5--27$μ$m, and 10$^{-6}$, respectively. Two complemental designs of binary shaped pupil mask coronagraph are presented. The SCI has capability of simultaneous observations of one target using two channels, a short channel with an InSb detector and a long wavelength channel with a Si:As detector. We also give a report on the current progress in the development of key technologies for the SCI.
△ Less
Submitted 16 August, 2011;
originally announced August 2011.
-
Multi-Color Coronagraph Experiment in a Vacuum Testbed with a Binary Shaped Pupil Mask
Authors:
Kanae Haze,
Keigo Enya,
Lyu Abe,
Takayuki Kotani,
Takao Nakagawa,
Toshimichi Sato,
Tomoyasu Yamamuro
Abstract:
We conducted a number of multi-band coronagraph experiments using a vacuum chamber and a binary-shaped pupil mask which in principle should work at all wavelengths, in the context of the research and development on a coronagraph to observe extra-solar planets (exoplanets) directly. The aim of this work is to demonstrate that subtraction of Point Spread Function (PSF) and multi-band experiments usi…
▽ More
We conducted a number of multi-band coronagraph experiments using a vacuum chamber and a binary-shaped pupil mask which in principle should work at all wavelengths, in the context of the research and development on a coronagraph to observe extra-solar planets (exoplanets) directly. The aim of this work is to demonstrate that subtraction of Point Spread Function (PSF) and multi-band experiments using a binary-shaped pupil mask coronagraph would help improve the contrast in the observation of exoplanets. A checkerboard mask, a kind of binary-shaped pupil mask, was used. We improved the temperature stability by installing the coronagraph optics in a vacuum chamber, controlling the temperature of the optical bench, and covering the vacuum chamber with thermal insulation layers. We evaluated how much the PSF subtraction contributes to the high contrast observation by subtracting the images obtained through the coronagraph. We also carried out multi- band experiments in order to demonstrate a more realistic observation using Super luminescent Light Emitting Diodes (SLEDs) with center wavelengths of 650nm, 750nm, 800nm and 850nm. A contrast of 2.3x10-7 was obtained for the raw coronagraphic image and a contrast of 1.3x10-9 was achieved after PSF subtraction with a He-Ne laser at 632.8nm wavelength. Thus, the contrast was improved by around two orders of magnitude from the raw contrast by subtracting the PSF. We achieved contrasts of 3.1x10-7, 1.1x10-6, 1.6x10-6 and 2.5x10-6 at the bands of 650nm, 750nm, 800nm and 850nm, respectively, in the multi-band experiments. The results show that contrast within each of the wavelength bands was significantly improved compared with non-coronagraphic optics. We demonstrated PSF subtraction is potentially beneficial for improving contrast of the coronagraph, and this coronagraph produces a significant improvement in contrast with multi-band light sources.
△ Less
Submitted 11 May, 2011;
originally announced May 2011.
-
Detection of an H-alpha Emission Line on a Quasar, RX J1759.4+6638, at z=4.3 with AKARI
Authors:
Shinki Oyabu,
Takehiko Wada,
Youichi Ohyama,
Hideo Matsuhara,
Toshinobu Takagi,
Takao Nakagawa,
Takashi Onaka,
Naofumi Fujishiro,
Daisuke Ishihara,
Yoshifusa Ita,
Hirokazu Kataza,
Woojung Kim,
Toshio Matsumoto,
Hiroshi Murakami,
Itsuki Sakon,
Toshihiko Tanabe,
Kazunori Uemizu,
Munetaka Ueno,
Fumihiko Usui,
Hidenori Watarai,
Kanae Haze
Abstract:
We report the detection of an H-alpha emission line in the low resolution spectrum of a quasar, RX J1759.4+6638, at a redshift of 4.3 with the InfraRed Camera (IRC) onboard the AKARI. This is the first spectroscopic detection of an H-alpha emission line in a quasar beyond z=4. The overall spectral energy distribution (SED) of RX J1759.4+6638 in the near- and mid-infrared wavelengths agrees with…
▽ More
We report the detection of an H-alpha emission line in the low resolution spectrum of a quasar, RX J1759.4+6638, at a redshift of 4.3 with the InfraRed Camera (IRC) onboard the AKARI. This is the first spectroscopic detection of an H-alpha emission line in a quasar beyond z=4. The overall spectral energy distribution (SED) of RX J1759.4+6638 in the near- and mid-infrared wavelengths agrees with a median SED of the nearby quasars and the flux ratio of F(Ly-alpha)/F(H-alpha) is consistent with those of previous reports for lower-redshift quasars.
△ Less
Submitted 2 June, 2007;
originally announced June 2007.