-
Muon polarization in the MEG experiment: predictions and measurements
Authors:
A. M. Baldini,
Y. Bao,
E. Baracchini,
C. Bemporad,
F. Berg,
M. Biasotti,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
G. Chiarello,
C. Chiri,
A. De Bari,
M. De Gerone,
A. DÓnofrio,
S. Dussoni,
Y. Fujii,
L. Galli,
F. Gatti,
F. Grancagnolo,
M. Grassi,
A. Graziosi,
D. N. Grigoriev,
T. Haruyama,
M. Hildebrandt
, et al. (45 additional authors not shown)
Abstract:
The MEG experiment makes use of one of the world's most intense low energy muon beams, in order to search for the lepton flavour violating process $μ^{+} \rightarrow {\rm e}^{+} γ$. We determined the residual beam polarization at the thin stop** target, by measuring the asymmetry of the angular distribution of Michel decay positrons as a function of energy. The initial muon beam polarization at…
▽ More
The MEG experiment makes use of one of the world's most intense low energy muon beams, in order to search for the lepton flavour violating process $μ^{+} \rightarrow {\rm e}^{+} γ$. We determined the residual beam polarization at the thin stop** target, by measuring the asymmetry of the angular distribution of Michel decay positrons as a function of energy. The initial muon beam polarization at the production is predicted to be $P_μ = -1$ by the Standard Model (SM) with massless neutrinos. We estimated our residual muon polarization to be $P_μ = -0.85 \pm 0.03 ~ {\rm (stat)} ~ { }^{+ 0.04}_{-0.05} ~ {\rm (syst)}$ at the stop** target, which is consistent with the SM predictions when the depolarizing effects occurring during the muon production, propagation and moderation in the target are taken into account. The knowledge of beam polarization is of fundamental importance in order to model the background of our ${\megsign}$ search induced by the muon radiative decay: $μ^{+} \rightarrow {\rm e}^{+} \barν_μ ν_{\rm e} γ$.
△ Less
Submitted 28 April, 2016; v1 submitted 15 October, 2015;
originally announced October 2015.
-
The Physics of the B Factories
Authors:
A. J. Bevan,
B. Golob,
Th. Mannel,
S. Prell,
B. D. Yabsley,
K. Abe,
H. Aihara,
F. Anulli,
N. Arnaud,
T. Aushev,
M. Beneke,
J. Beringer,
F. Bianchi,
I. I. Bigi,
M. Bona,
N. Brambilla,
J. B rodzicka,
P. Chang,
M. J. Charles,
C. H. Cheng,
H. -Y. Cheng,
R. Chistov,
P. Colangelo,
J. P. Coleman,
A. Drutskoy
, et al. (2009 additional authors not shown)
Abstract:
This work is on the Physics of the B Factories. Part A of this book contains a brief description of the SLAC and KEK B Factories as well as their detectors, BaBar and Belle, and data taking related issues. Part B discusses tools and methods used by the experiments in order to obtain results. The results themselves can be found in Part C.
Please note that version 3 on the archive is the auxiliary…
▽ More
This work is on the Physics of the B Factories. Part A of this book contains a brief description of the SLAC and KEK B Factories as well as their detectors, BaBar and Belle, and data taking related issues. Part B discusses tools and methods used by the experiments in order to obtain results. The results themselves can be found in Part C.
Please note that version 3 on the archive is the auxiliary version of the Physics of the B Factories book. This uses the notation alpha, beta, gamma for the angles of the Unitarity Triangle. The nominal version uses the notation phi_1, phi_2 and phi_3. Please cite this work as Eur. Phys. J. C74 (2014) 3026.
△ Less
Submitted 31 October, 2015; v1 submitted 24 June, 2014;
originally announced June 2014.
-
Measurement of the radiative decay of polarized muons in the MEG experiment
Authors:
MEG Collaboration,
A. M. Baldini,
Y. Bao,
E. Baracchini,
C. Bemporad,
F. Berg,
M. Biasotti,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
G. Chiarello,
C. Chiri,
A. de Bari,
M. De Gerone,
A. D'Onofrio,
S. Dussoni,
Y. Fujii,
L. Galli,
F. Gatti,
F. Grancagnolo,
M. Grassi,
A. Graziosi,
D. N. Grigoriev,
T. Haruyama
, et al. (46 additional authors not shown)
Abstract:
We studied the radiative muon decay $μ^+ \to e^+ν\barνγ$ by using for the first time an almost fully polarized muon source. We identified a large sample (~13000) of these decays in a total sample of 1.8x10^14 positive muon decays collected in the MEG experiment in the years 2009--2010 and measured the branching ratio B($μ^+ \to e^+ν\barνγ$) = (6.03+-0.14(stat.)+-0.53(sys.))x10^-8 for E_e > 45 MeV…
▽ More
We studied the radiative muon decay $μ^+ \to e^+ν\barνγ$ by using for the first time an almost fully polarized muon source. We identified a large sample (~13000) of these decays in a total sample of 1.8x10^14 positive muon decays collected in the MEG experiment in the years 2009--2010 and measured the branching ratio B($μ^+ \to e^+ν\barνγ$) = (6.03+-0.14(stat.)+-0.53(sys.))x10^-8 for E_e > 45 MeV and E_γ > 40 MeV, consistent with the Standard Model prediction. The precise measurement of this decay mode provides a basic tool for the timing calibration, a normalization channel, and a strong quality check of the complete MEG experiment in the search for $μ^+ \to e^+γ$ process.
△ Less
Submitted 7 March, 2016; v1 submitted 11 December, 2013;
originally announced December 2013.
-
The MEG detector for $μ+\to e+γ$ decay search
Authors:
J. Adam,
X. Bai,
A. M. Baldini,
E. Baracchini,
C. Bemporad,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
C. Cerri,
M. Corbo,
N. Curalli,
A. De Bari,
M. De Gerone,
L. Del Frate,
S. Doke,
S. Dussoni,
J. Egger,
K. Fratini,
Y. Fujii,
L. Galli,
S. Galeotti,
G. Gallucci,
F. Gatti,
B. Golden
, et al. (51 additional authors not shown)
Abstract:
The MEG (Mu to Electron Gamma) experiment has been running at the Paul Scherrer Institut (PSI), Switzerland since 2008 to search for the decay \meg\ by using one of the most intense continuous $μ^+$ beams in the world. This paper presents the MEG components: the positron spectrometer, including a thin target, a superconducting magnet, a set of drift chambers for measuring the muon decay vertex and…
▽ More
The MEG (Mu to Electron Gamma) experiment has been running at the Paul Scherrer Institut (PSI), Switzerland since 2008 to search for the decay \meg\ by using one of the most intense continuous $μ^+$ beams in the world. This paper presents the MEG components: the positron spectrometer, including a thin target, a superconducting magnet, a set of drift chambers for measuring the muon decay vertex and the positron momentum, a timing counter for measuring the positron time, and a liquid xenon detector for measuring the photon energy, position and time. The trigger system, the read-out electronics and the data acquisition system are also presented in detail. The paper is completed with a description of the equipment and techniques developed for the calibration in time and energy and the simulation of the whole apparatus.
△ Less
Submitted 10 April, 2013; v1 submitted 10 March, 2013;
originally announced March 2013.
-
New constraint on the existence of the mu+-> e+ gamma decay
Authors:
MEG Collaboration,
J. Adam,
X. Bai,
A. M. Baldini,
E. Baracchini,
C. Bemporad,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
C. Cerri,
A. de Bari,
M. De Gerone,
T. Doke,
S. Dussoni,
J. Egger,
K. Fratini,
Y. Fujii,
L. Galli,
G. Gallucci,
F. Gatti,
B. Golden,
M. Grassi,
A. Graziosi,
D. N. Grigoriev
, et al. (49 additional authors not shown)
Abstract:
The analysis of a combined data set, totaling 3.6 \times 10^14 stopped muons on target, in the search for the lepton flavour violating decay mu^+ -> e^+ gamma is presented. The data collected by the MEG experiment at the Paul Scherrer Institut show no excess of events compared to background expectations and yield a new upper limit on the branching ratio of this decay of 5.7 \times 10^-13 (90% conf…
▽ More
The analysis of a combined data set, totaling 3.6 \times 10^14 stopped muons on target, in the search for the lepton flavour violating decay mu^+ -> e^+ gamma is presented. The data collected by the MEG experiment at the Paul Scherrer Institut show no excess of events compared to background expectations and yield a new upper limit on the branching ratio of this decay of 5.7 \times 10^-13 (90% confidence level). This represents a four times more stringent limit than the previous world best limit set by MEG.
△ Less
Submitted 23 April, 2013; v1 submitted 4 March, 2013;
originally announced March 2013.
-
MEG Upgrade Proposal
Authors:
A. M. Baldini,
F. Cei,
C. Cerri,
S. Dussoni,
L. Galli,
M. Grassi,
D. Nicolò,
F. Raffaelli,
F. Sergiampietri,
G. Signorelli,
F. Tenchini,
D. Bagliani,
M. De Gerone,
F. Gatti,
E. Baracchini,
Y. Fujii,
T. Iwamoto,
D. Kaneko,
T. Mori,
M. Nishimura,
W. Ootani,
R. Sawada,
Y. Uchiyama,
G. Boca,
P. W. Cattaneo
, et al. (43 additional authors not shown)
Abstract:
We propose the continuation of the MEG experiment to search for the charged lepton flavour violating decay (cLFV) μ\to e γ, based on an upgrade of the experiment, which aims for a sensitivity enhancement of one order of magnitude compared to the final MEG result, down to the $6 \times 10^{-14}$ level. The key features of this new MEG upgrade are an increased rate capability of all detectors to ena…
▽ More
We propose the continuation of the MEG experiment to search for the charged lepton flavour violating decay (cLFV) μ\to e γ, based on an upgrade of the experiment, which aims for a sensitivity enhancement of one order of magnitude compared to the final MEG result, down to the $6 \times 10^{-14}$ level. The key features of this new MEG upgrade are an increased rate capability of all detectors to enable running at the intensity frontier and improved energy, angular and timing resolutions, for both the positron and photon arms of the detector. On the positron-side a new low-mass, single volume, high granularity tracker is envisaged, in combination with a new highly segmented, fast timing counter array, to track positron from a thinner stop** target. The photon-arm, with the largest liquid xenon (LXe) detector in the world, totalling 900 l, will also be improved by increasing the granularity at the incident face, by replacing the current photomultiplier tubes (PMTs) with a larger number of smaller photosensors and optimizing the photosensor layout also on the lateral faces. A new DAQ scheme involving the implementation of a new combined readout board capable of integrating the diverse functions of digitization, trigger capability and splitter functionality into one condensed unit, is also under development. We describe here the status of the MEG experiment, the scientific merits of the upgrade and the experimental methods we plan to use.
△ Less
Submitted 4 February, 2013; v1 submitted 30 January, 2013;
originally announced January 2013.
-
Improvement of xenon purification system using a combination of a pulse tube refrigerator and a coaxial heat exchanger
Authors:
Wan-Ting Chen,
D. Chbib,
J. -P. Cussonneau,
J. Donnard,
S. Duval,
O. Lemaire,
M. Le Calloch,
P. Le Ray,
A. -F. Mohamad-Hadi,
E. Morteau,
T. Oger,
L. Scotto-Lavina,
J. -S. Stutzmann,
D. Thers,
P. Briend,
T. Haruyama,
S. Mihara,
T. Tauchi
Abstract:
We have developed a compact cryogenic system with a pulse tube refrigerator and a coaxial heat exchanger. This liquefaction-purification system not only saves the cooling power used to reach high gaseous recirculation rate, but also reduces the impurity level with high speed. The heat exchanger operates with an efficiency of 99%, which indicates the possibility for fast xenon gas recirculation in…
▽ More
We have developed a compact cryogenic system with a pulse tube refrigerator and a coaxial heat exchanger. This liquefaction-purification system not only saves the cooling power used to reach high gaseous recirculation rate, but also reduces the impurity level with high speed. The heat exchanger operates with an efficiency of 99%, which indicates the possibility for fast xenon gas recirculation in a highpressurized large-scale xenon storage with much less thermal losses.
△ Less
Submitted 17 May, 2012;
originally announced May 2012.
-
Reduction of thermal fluctuations in a cryogenic laser interferometric gravitational wave detector
Authors:
Takashi Uchiyama,
Shinji Miyoki,
Souichi Telada,
Kazuhiro Yamamoto,
Masatake Ohashi,
Kazuhiro Agatsuma,
Koji Arai,
Masa-Katsu Fujimoto,
Tomiyoshi Haruyama,
Seiji Kawamura,
Osamu Miyakawa,
Naoko Ohishi,
Takanori Saito,
Takakazu Shintomi,
Toshikazu Suzuki,
Ryutaro Takahashi,
Daisuke Tatsumi
Abstract:
The thermal fluctuation of mirror surfaces is the fundamental limitation for interferometric gravitational wave (GW) detectors. Here, we experimentally demonstrate for the first time a reduction in a mirror's thermal fluctuation in a GW detector with sapphire mirrors from the Cryogenic Laser Interferometer Observatory at 17\,K and 18\,K. The detector sensitivity, which was limited by the mirror's…
▽ More
The thermal fluctuation of mirror surfaces is the fundamental limitation for interferometric gravitational wave (GW) detectors. Here, we experimentally demonstrate for the first time a reduction in a mirror's thermal fluctuation in a GW detector with sapphire mirrors from the Cryogenic Laser Interferometer Observatory at 17\,K and 18\,K. The detector sensitivity, which was limited by the mirror's thermal fluctuation at room temperature, was improved in the frequency range of 90\,Hz to 240\,Hz by cooling the mirrors. The improved sensitivity reached a maximum of $2.2 \times 10^{-19}\,\textrm{m}/\sqrt{\textrm{Hz}}$ at 165\,Hz.
△ Less
Submitted 16 February, 2012;
originally announced February 2012.
-
First Muon-Neutrino Disappearance Study with an Off-Axis Beam
Authors:
T2K Collaboration,
K. Abe,
N. Abgrall,
Y. Ajima,
H. Aihara,
J. B. Albert,
C. Andreopoulos,
B. Andrieu,
M. D. Anerella,
S. Aoki,
O. Araoka,
J. Argyriades,
A. Ariga,
T. Ariga,
S. Assylbekov,
D. Autiero,
A. Badertscher,
M. Barbi,
G. J. Barker,
G. Barr,
M. Bass,
M. Batkiewicz,
F. Bay,
S. Bentham,
V. Berardi
, et al. (422 additional authors not shown)
Abstract:
We report a measurement of muon-neutrino disappearance in the T2K experiment. The 295-km muon-neutrino beam from Tokai to Kamioka is the first implementation of the off-axis technique in a long-baseline neutrino oscillation experiment. With data corresponding to 1.43 10**20 protons on target, we observe 31 fully-contained single muon-like ring events in Super-Kamiokande, compared with an expectati…
▽ More
We report a measurement of muon-neutrino disappearance in the T2K experiment. The 295-km muon-neutrino beam from Tokai to Kamioka is the first implementation of the off-axis technique in a long-baseline neutrino oscillation experiment. With data corresponding to 1.43 10**20 protons on target, we observe 31 fully-contained single muon-like ring events in Super-Kamiokande, compared with an expectation of 104 +- 14 (syst) events without neutrino oscillations. The best-fit point for two-flavor nu_mu -> nu_tau oscillations is sin**2(2 theta_23) = 0.98 and |Δm**2_32| = 2.65 10**-3 eV**2. The boundary of the 90 % confidence region includes the points (sin**2(2 theta_23),|Δm**2_32|) = (1.0, 3.1 10**-3 eV**2), (0.84, 2.65 10**-3 eV**2) and (1.0, 2.2 10**-3 eV**2).
△ Less
Submitted 6 January, 2012;
originally announced January 2012.
-
Measurements of the T2K neutrino beam properties using the INGRID on-axis near detector
Authors:
K. Abe,
N. Abgrall,
Y. Ajima,
H. Aihara,
J. B. Albert,
C. Andreopoulos,
B. Andrieu,
M. D. Anerella,
S. Aoki,
O. Araoka,
J. Argyriades,
A. Ariga,
T. Ariga,
S. Assylbekov,
D. Autiero,
A. Badertscher,
M. Barbi,
G. J. Barker,
G. Barr,
M. Bass,
M. Batkiewicz,
F. Bay,
S. Bentham,
V. Berardi,
B. E. Berger
, et al. (407 additional authors not shown)
Abstract:
Precise measurement of neutrino beam direction and intensity was achieved based on a new concept with modularized neutrino detectors. INGRID (Interactive Neutrino GRID) is an on-axis near detector for the T2K long baseline neutrino oscillation experiment. INGRID consists of 16 identical modules arranged in horizontal and vertical arrays around the beam center. The module has a sandwich structure o…
▽ More
Precise measurement of neutrino beam direction and intensity was achieved based on a new concept with modularized neutrino detectors. INGRID (Interactive Neutrino GRID) is an on-axis near detector for the T2K long baseline neutrino oscillation experiment. INGRID consists of 16 identical modules arranged in horizontal and vertical arrays around the beam center. The module has a sandwich structure of iron target plates and scintillator trackers. INGRID directly monitors the muon neutrino beam profile center and intensity using the number of observed neutrino events in each module. The neutrino beam direction is measured with accuracy better than 0.4 mrad from the measured profile center. The normalized event rate is measured with 4% precision.
△ Less
Submitted 14 November, 2011;
originally announced November 2011.
-
New limit on the lepton-flavour violating decay mu -> e gamma
Authors:
MEG collaboration,
J. Adam,
X. Bai,
A. M. Baldini,
E. Baracchini,
C. Bemporad,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
C. Cerri,
A. de Bari,
M. De Gerone,
T. Doke,
S. Dussoni,
J. Egger,
K. Fratini,
Y. Fujii,
L. Galli,
G. Gallucci,
F. Gatti,
B. Golden,
M. Grassi,
D. N. Grigoriev,
T. Haruyama
, et al. (42 additional authors not shown)
Abstract:
We present a new result based on an analysis of the data collected by the MEG detector at the Paul Scherrer Institut in 2009 and 2010, in search of the lepton flavour violating decay mu->e gamma. The likelihood analysis of the combined data sample, which corresponds to a total of 1.8 x 10**14 muon decays, gives a 90% C.L. upper limit of 2.4 x 10**-12 on the branching ratio of the mu->e gamma decay…
▽ More
We present a new result based on an analysis of the data collected by the MEG detector at the Paul Scherrer Institut in 2009 and 2010, in search of the lepton flavour violating decay mu->e gamma. The likelihood analysis of the combined data sample, which corresponds to a total of 1.8 x 10**14 muon decays, gives a 90% C.L. upper limit of 2.4 x 10**-12 on the branching ratio of the mu->e gamma decay, constituting the most stringent limit on the existence of this decay to date.
△ Less
Submitted 2 September, 2011; v1 submitted 27 July, 2011;
originally announced July 2011.
-
Indication of Electron Neutrino Appearance from an Accelerator-produced Off-axis Muon Neutrino Beam
Authors:
T2K Collaboration,
K. Abe,
N. Abgrall,
Y. Ajima,
H. Aihara,
J. B. Albert,
C. Andreopoulos,
B. Andrieu,
S. Aoki,
O. Araoka,
J. Argyriades,
A. Ariga,
T. Ariga,
S. Assylbekov,
D. Autiero,
A. Badertscher,
M. Barbi,
G. J. Barker,
G. Barr,
M. Bass,
F. Bay,
S. Bentham,
V. Berardi,
B. E. Berger,
I. Bertram
, et al. (387 additional authors not shown)
Abstract:
The T2K experiment observes indications of $ν_μ\rightarrow ν_e$ appearance in data accumulated with $1.43\times10^{20}$ protons on target. Six events pass all selection criteria at the far detector. In a three-flavor neutrino oscillation scenario with $|Δm_{23}^2|=2.4\times10^{-3}$ eV$^2$, $\sin^2 2θ_{23}=1$ and $\sin^2 2θ_{13}=0$, the expected number of such events is 1.5$\pm$0.3(syst.). Under th…
▽ More
The T2K experiment observes indications of $ν_μ\rightarrow ν_e$ appearance in data accumulated with $1.43\times10^{20}$ protons on target. Six events pass all selection criteria at the far detector. In a three-flavor neutrino oscillation scenario with $|Δm_{23}^2|=2.4\times10^{-3}$ eV$^2$, $\sin^2 2θ_{23}=1$ and $\sin^2 2θ_{13}=0$, the expected number of such events is 1.5$\pm$0.3(syst.). Under this hypothesis, the probability to observe six or more candidate events is 7$\times10^{-3}$, equivalent to 2.5$σ$ significance. At 90% C.L., the data are consistent with 0.03(0.04)$<\sin^2 2θ_{13}<$ 0.28(0.34) for $δ_{\rm CP}=0$ and a normal (inverted) hierarchy.
△ Less
Submitted 25 July, 2011; v1 submitted 14 June, 2011;
originally announced June 2011.
-
The T2K Experiment
Authors:
T2K Collaboration,
K. Abe,
N. Abgrall,
H. Aihara,
Y. Ajima,
J. B. Albert,
D. Allan,
P. -A. Amaudruz,
C. Andreopoulos,
B. Andrieu,
M. D. Anerella,
C. Angelsen,
S. Aoki,
O. Araoka,
J. Argyriades,
A. Ariga,
T. Ariga,
S. Assylbekov,
J. P. A. M. de André,
D. Autiero,
A. Badertscher,
O. Ballester,
M. Barbi,
G. J. Barker,
P. Baron
, et al. (499 additional authors not shown)
Abstract:
The T2K experiment is a long-baseline neutrino oscillation experiment. Its main goal is to measure the last unknown lepton sector mixing angle θ_{13} by observing ν_e appearance in a ν_μ beam. It also aims to make a precision measurement of the known oscillation parameters, Δm^{2}_{23} and sin^{2} 2θ_{23}, via ν_μ disappearance studies. Other goals of the experiment include various neutrino cross…
▽ More
The T2K experiment is a long-baseline neutrino oscillation experiment. Its main goal is to measure the last unknown lepton sector mixing angle θ_{13} by observing ν_e appearance in a ν_μ beam. It also aims to make a precision measurement of the known oscillation parameters, Δm^{2}_{23} and sin^{2} 2θ_{23}, via ν_μ disappearance studies. Other goals of the experiment include various neutrino cross section measurements and sterile neutrino searches. The experiment uses an intense proton beam generated by the J-PARC accelerator in Tokai, Japan, and is composed of a neutrino beamline, a near detector complex (ND280), and a far detector (Super-Kamiokande) located 295 km away from J-PARC. This paper provides a comprehensive review of the instrumentation aspect of the T2K experiment and a summary of the vital information for each subsystem.
△ Less
Submitted 8 June, 2011; v1 submitted 6 June, 2011;
originally announced June 2011.
-
Xenon Recirculation-Purification with a Heat Exchanger
Authors:
K. L. Giboni,
E. Aprile,
B. Choi,
T. Haruyama,
R. F. Lang,
K. E. Lim,
A. J. Melgarejo,
G. Plante
Abstract:
Liquid-xenon based particle detectors have been dramatically growing in size during the last years, and are now exceeding the one-ton scale. The required high xenon purity is usually achieved by continuous recirculation of xenon gas through a high-temperature getter. This challenges the traditional way of cooling these large detectors, since in a thermally well insulated detector, most of the cool…
▽ More
Liquid-xenon based particle detectors have been dramatically growing in size during the last years, and are now exceeding the one-ton scale. The required high xenon purity is usually achieved by continuous recirculation of xenon gas through a high-temperature getter. This challenges the traditional way of cooling these large detectors, since in a thermally well insulated detector, most of the cooling power is spent to compensate losses from recirculation. The phase change during recondensing requires five times more cooling power than cooling the gas from ambient temperature to -100C (173 K). Thus, to reduce the cooling power requirements for large detectors, we propose to use the heat from the purified incoming gas to evaporate the outgoing xenon gas, by means of a heat exchanger. Generally, a heat exchanger would appear to be only of very limited use, since evaporation and liquefaction occur at zero temperature difference. However, the use of a recirculation pump reduces the pressure of the extracted liquid, forces it to evaporate, and thus cools it down. We show that this temperature difference can be used for an efficient heat exchange process. We investigate the use of a commercial parallel plate heat exchanger with a small liquid xenon detector. Although we expected to be limited by the available cooling power to flow rates of about 2 SLPM, rates in excess of 12 SLPM can easily be sustained, limited only by the pump speed and the impedance of the flow loop. The heat exchanger operates with an efficiency of (96.8 +/- 0.5)%. This opens the possibility for fast xenon gas recirculation in large-scale experiments, while minimizing thermal losses.
△ Less
Submitted 4 March, 2011;
originally announced March 2011.
-
Belle II Technical Design Report
Authors:
T. Abe,
I. Adachi,
K. Adamczyk,
S. Ahn,
H. Aihara,
K. Akai,
M. Aloi,
L. Andricek,
K. Aoki,
Y. Arai,
A. Arefiev,
K. Arinstein,
Y. Arita,
D. M. Asner,
V. Aulchenko,
T. Aushev,
T. Aziz,
A. M. Bakich,
V. Balagura,
Y. Ban,
E. Barberio,
T. Barvich,
K. Belous,
T. Bergauer,
V. Bhardwaj
, et al. (387 additional authors not shown)
Abstract:
The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been pr…
▽ More
The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been proposed. A new international collaboration Belle-II, is being formed. The Technical Design Report presents physics motivation, basic methods of the accelerator upgrade, as well as key improvements of the detector.
△ Less
Submitted 1 November, 2010;
originally announced November 2010.
-
A limit for the mu -> e gamma decay from the MEG experiment
Authors:
MEG collaboration,
J. Adam,
X. Bai,
A. Baldini,
E. Baracchini,
A. Barchiesi,
C. Bemporad,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
G. Cecchet,
F. Cei,
C. Cerri,
A. De Bari,
M. De Gerone,
T. Doke,
S. Dussoni,
J. Egger,
L. Galli,
G. Gallucci,
F. Gatti,
B. Golden,
M. Grassi,
D. N. Grigoriev,
T. Haruyama
, et al. (45 additional authors not shown)
Abstract:
A search for the decay mu -> e gamma, performed at PSI and based on data from the initial three months of operation of the MEG experiment, yields an upper limit on the branching ratio of BR(mu -> e gamma) < 2.8 x 10**-11 (90% C.L.). This corresponds to the measurement of positrons and photons from ~ 10**14 stopped mu-decays by means of a superconducting positron spectrometer and a 900 litre liqu…
▽ More
A search for the decay mu -> e gamma, performed at PSI and based on data from the initial three months of operation of the MEG experiment, yields an upper limit on the branching ratio of BR(mu -> e gamma) < 2.8 x 10**-11 (90% C.L.). This corresponds to the measurement of positrons and photons from ~ 10**14 stopped mu-decays by means of a superconducting positron spectrometer and a 900 litre liquid xenon photon detector.
△ Less
Submitted 4 March, 2010; v1 submitted 18 August, 2009;
originally announced August 2009.
-
Summary of the J-PARC UCN Taskforce
Authors:
The J-Parc Ucn Taskforce,
:,
Tomokazu Aso,
Masatoshi Futakawa,
Tomiyoshi Haruyama,
Kazuo Hasegawa,
Yujiro Ikeda,
Masanori Ikegami,
Yukihide Kamiya,
Takashi Kato,
Nobuhiro Kimura,
Yoshiaki Kiyanagi,
Yasuo Maekawa,
Yasuhiro Masuda,
Taichi Miura,
Masaharu Numajiri,
Toru Ogitsu,
Nobuo Ouchi,
Kotaro Sato,
Hirohiko Shimizu,
Eiichi Takasaki,
Nobuyuki Takenaka,
Akira Yamamoto,
Satoru Yamashita
Abstract:
Discussions in the taskforce meetings in the period of Jan.-Mar. 2009 on the technical possibility of the ultracold neutron (UCN) source at the Japan Proton Accelerator Research Complex (J-PARC) is summarized.
Discussions in the taskforce meetings in the period of Jan.-Mar. 2009 on the technical possibility of the ultracold neutron (UCN) source at the Japan Proton Accelerator Research Complex (J-PARC) is summarized.
△ Less
Submitted 2 July, 2009;
originally announced July 2009.
-
Expected Performance of the ATLAS Experiment - Detector, Trigger and Physics
Authors:
The ATLAS Collaboration,
G. Aad,
E. Abat,
B. Abbott,
J. Abdallah,
A. A. Abdelalim,
A. Abdesselam,
O. Abdinov,
B. Abi,
M. Abolins,
H. Abramowicz,
B. S. Acharya,
D. L. Adams,
T. N. Addy,
C. Adorisio,
P. Adragna,
T. Adye,
J. A. Aguilar-Saavedra,
M. Aharrouche,
S. P. Ahlen,
F. Ahles,
A. Ahmad,
H. Ahmed,
G. Aielli,
T. Akdogan
, et al. (2587 additional authors not shown)
Abstract:
A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on…
▽ More
A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on simulations of the detector and physics processes, with particular emphasis given to the data expected from the first years of operation of the LHC at CERN.
△ Less
Submitted 14 August, 2009; v1 submitted 28 December, 2008;
originally announced January 2009.
-
Current status of the CLIO project
Authors:
K Yamamoto,
T Uchiyama,
S Miyoki,
M Ohashi,
K Kuroda,
H Ishitsuka,
T Akutsu,
S Telada,
T Tomaru,
T Suzuki,
N Sato,
Y Saito,
Y Higashi,
T Haruyama,
A Yamamoto,
T Shintomi,
D Tatsumi,
M Ando,
H Tagoshi,
N Kanda,
N Awaya,
S Yamagishi,
H Takahashi,
A Araya,
A Takamori
, et al. (5 additional authors not shown)
Abstract:
CLIO (Cryogenic Laser Interferometer Observatory) is a Japanese gravitational wave detector project. One of the main purposes of CLIO is to demonstrate thermal-noise suppression by cooling mirrors for a future Japanese project, LCGT (Large-scale Cryogenic Gravitational Telescope). The CLIO site is in Kamioka mine, as is LCGT. The progress of CLIO between 2005 and 2007 (room- and cryogenic-temper…
▽ More
CLIO (Cryogenic Laser Interferometer Observatory) is a Japanese gravitational wave detector project. One of the main purposes of CLIO is to demonstrate thermal-noise suppression by cooling mirrors for a future Japanese project, LCGT (Large-scale Cryogenic Gravitational Telescope). The CLIO site is in Kamioka mine, as is LCGT. The progress of CLIO between 2005 and 2007 (room- and cryogenic-temperature experiments) is introduced in this article. In a room-temperature experiment, we made efforts to improve the sensitivity. The current best sensitivity at 300 K is about $6 \times 10^{-21} /\sqrt{\rm Hz}$ around 400 Hz. Below 20 Hz, the strain (not displacement) sensitivity is comparable to that of LIGO, although the baselines of CLIO are 40-times shorter (CLIO: 100m, LIGO: 4km). This is because seismic noise is extremely small in Kamioka mine. We operated the interferometer at room temperature for gravitational wave observations. We obtained 86 hours of data. In the cryogenic experiment, it was confirmed that the mirrors were sufficiently cooled (14 K). However, we found that the radiation shield ducts transferred 300K radiation into the cryostat more effectively than we had expected. We observed that noise caused by pure aluminum wires to suspend a mirror was suppressed by cooling the mirror.
△ Less
Submitted 15 May, 2008;
originally announced May 2008.
-
Conduction Effect of Thermal Radiation in a Metal Shield Pipe in a Cryostat for a Cryogenic Interferometric Gravitational Wave Detector
Authors:
Takayuki Tomaru,
Masao Tokunari,
Kazuaki Kuroda,
Takashi Uchiyama,
Akira Okutomi,
Masatake Ohashi,
Hiroyuki Kirihara,
Nobuhiro Kimura,
Yoshio Saito,
Nobuaki Sato,
Takakazu Shintomi,
Toshikazu Suzuki,
Tomiyoshi Haruyama,
Shinji Miyoki,
Kazuhiro Yamamoto,
Akira Yamamoto
Abstract:
A large heat load caused by thermal radiation through a metal shield pipe was observed in a cooling test of a cryostat for a prototype of a cryogenic interferometric gravitational wave detector. The heat load was approximately 1000 times larger than the value calculated by the Stefan-Boltzmann law. We studied this phenomenon by simulation and experiment and found that it was caused by the conduc…
▽ More
A large heat load caused by thermal radiation through a metal shield pipe was observed in a cooling test of a cryostat for a prototype of a cryogenic interferometric gravitational wave detector. The heat load was approximately 1000 times larger than the value calculated by the Stefan-Boltzmann law. We studied this phenomenon by simulation and experiment and found that it was caused by the conduction of thermal radiation in a metal shield pipe.
△ Less
Submitted 6 November, 2007;
originally announced November 2007.
-
Current status of Japanese detectors
Authors:
Daisuke Tatsumi,
Ryutaro Takahashi,
Koji Arai,
Noriyasu Nakagawa,
Kazuhiro Agatsuma,
Toshitaka Yamazaki,
Mitsuhiro Fukushima,
Masa-Katsu Fujimoto,
Akiteru Takamori,
Alessandro Bertolini,
Virginio Sannibale,
Riccardo DeSalvo,
Szabolcs Marka,
Masaki Ando,
Kimio Tsubono,
Tomomi Akutsu,
Kazuhiro Yamamoto,
Hideki Ishitsuka,
Takashi Uchiyama,
Shinji Miyoki,
Masatake Ohashi,
Kazuaki Kuroda,
Norichika Awaya,
Nobuyuki Kanda,
Akito Araya
, et al. (7 additional authors not shown)
Abstract:
Current status of TAMA and CLIO detectors in Japan is reported in this article. These two interferometric gravitational-wave detectors are being developed for the large cryogenic gravitational wave telescope (LCGT) which is a future plan for detecting gravitational wave signals at least once per year.
TAMA300 is being upgraded to improve the sensitivity in low frequency region after the last o…
▽ More
Current status of TAMA and CLIO detectors in Japan is reported in this article. These two interferometric gravitational-wave detectors are being developed for the large cryogenic gravitational wave telescope (LCGT) which is a future plan for detecting gravitational wave signals at least once per year.
TAMA300 is being upgraded to improve the sensitivity in low frequency region after the last observation experiment in 2004. To reduce the seismic noises, we are installing new seismic isolation system, which is called TAMA Seismic Attenuation System, for the four test masses. We confirmed stable mass locks of a cavity and improvements of length and angular fluctuations by using two SASs. We are currently optimizing the performance of the third and fourth SASs. We continue TAMA300 operation and R&D studies for LCGT. Next data taking in the summer of 2007 is planned.
CLIO is a 100-m baseline length prototype detector for LCGT to investigate interferometer performance in cryogenic condition. The key features of CLIO are that it locates Kamioka underground site for low seismic noise level, and adopts cryogenic Sapphire mirrors for low thermal noise level. The first operation of the cryogenic interferometer was successfully demonstrated in February of 2006. Current sensitivity at room temperature is close to the target sensitivity within a factor of 4. Several observation experiments at room temperature have been done. Once the displacement noise reaches at thermal noise level of room temperature, its improvement by cooling test mass mirrors should be demonstrated.
△ Less
Submitted 22 April, 2007;
originally announced April 2007.
-
Pulse tube cryocooler with self-cancellation of cold stage vibration
Authors:
T. Suzuki,
T. Tomaru,
T. Haruyama,
N. Sato,
A. Yamamoto,
T. Shintomi,
Y. Ikushima,
R. Li
Abstract:
We experimentally demonstrated a new method for reducing the vibration of the cold stage of a cryocooler. Comparing the RMS amplitude with the case of no phase shift of the driving gas pressure between the two pairs, the longitudinal vibration of the cold stage was reduced by 96.1% at 126 K by supplying gas pressure with 180 degrees of phase shift.
We experimentally demonstrated a new method for reducing the vibration of the cold stage of a cryocooler. Comparing the RMS amplitude with the case of no phase shift of the driving gas pressure between the two pairs, the longitudinal vibration of the cold stage was reduced by 96.1% at 126 K by supplying gas pressure with 180 degrees of phase shift.
△ Less
Submitted 3 November, 2006;
originally announced November 2006.
-
Measurement of the mechanical loss of a cooled reflective coating for gravitational wave detection
Authors:
Kazuhiro Yamamoto,
Shinji Miyoki,
Takashi Uchiyama,
Hideki Ishitsuka,
Masatake Ohashi,
Kazuaki Kuroda,
Takayuki Tomaru,
Nobuaki Sato,
Toshikazu Suzuki,
Tomiyoshi Haruyama,
Akira Yamamoto,
Takakazu Shintomi,
Kenji Numata,
Koichi Waseda,
Kazuhiko Ito,
Koji Watanabe
Abstract:
We have measured the mechanical loss of a dielectric multilayer reflective coating (ion-beam sputtered SiO$_2$ and Ta$_2$O$_5$) in cooled mirrors. The loss was nearly independent of the temperature (4 K $\sim$ 300 K), frequency, optical loss, and stress caused by the coating, and the details of the manufacturing processes. The loss angle was $(4 \sim 6) \times 10^{-4}$. The temperature independe…
▽ More
We have measured the mechanical loss of a dielectric multilayer reflective coating (ion-beam sputtered SiO$_2$ and Ta$_2$O$_5$) in cooled mirrors. The loss was nearly independent of the temperature (4 K $\sim$ 300 K), frequency, optical loss, and stress caused by the coating, and the details of the manufacturing processes. The loss angle was $(4 \sim 6) \times 10^{-4}$. The temperature independence of this loss implies that the amplitude of the coating thermal noise, which is a severe limit in any precise measurement, is proportional to the square root of the temperature. Sapphire mirrors at 20 K satisfy the requirement concerning the thermal noise of even future interferometric gravitational wave detector projects on the ground, for example, LCGT.
△ Less
Submitted 22 July, 2006; v1 submitted 8 January, 2006;
originally announced January 2006.
-
Absorption of Scintillation Light in a 100 $\ell$ Liquid Xenon$γ$ Ray Detector and Expected Detector Performance
Authors:
A. Baldini,
C. Bemporad,
F. Cei,
T. Doke,
M. Grassi,
A. A. Grebenuk,
D. N. Grigoriev,
T. Haruyama,
K. Kasami,
J. Kikuchi,
A. Maki,
T. Mashimo,
S. Mihara,
T. Mitsuhashi,
T. Mori,
D. Nicolo`,
H. Nishiguchi,
W. Ootani,
K. Ozone,
A. Papa,
R. Pazzi,
S. Ritt,
R. Sawada,
F. Sergiampietri,
G. Signorelli
, et al. (6 additional authors not shown)
Abstract:
An 800L liquid xenon scintillation $γ$ ray detector is being developed for the MEG experiment which will search for $μ^+\to\mathrm{e}^+γ$ decay at the Paul Scherrer Institut. Absorption of scintillation light of xenon by impurities might possibly limit the performance of such a detector. We used a 100L prototype with an active volume of 372x372x496 mm$^3$ to study the scintillation light absorpt…
▽ More
An 800L liquid xenon scintillation $γ$ ray detector is being developed for the MEG experiment which will search for $μ^+\to\mathrm{e}^+γ$ decay at the Paul Scherrer Institut. Absorption of scintillation light of xenon by impurities might possibly limit the performance of such a detector. We used a 100L prototype with an active volume of 372x372x496 mm$^3$ to study the scintillation light absorption. We have developed a method to evaluate the light absorption, separately from elastic scattering of light, by measuring cosmic rays and $α$ sources. By using a suitable purification technique, an absorption length longer than 100 cm has been achieved. The effects of the light absorption on the energy resolution are estimated by Monte Carlo simulation.
△ Less
Submitted 6 July, 2004;
originally announced July 2004.
-
Liquid Xe scintillation calorimetry and Xe optical properties
Authors:
A. Baldini,
C. Bemporad,
F. Cei,
T. Doke,
M. Grassi,
T. Haruyama,
S. Mihara,
T. Mori,
D. Nicolò,
H. Nishiguchi,
W. Ootani,
K. Ozone,
A. Papa,
R. Pazzi,
R. Sawada,
F. Sergiampietri,
G. Signorelli,
S. Suzuki,
K. Terasawa
Abstract:
The optical properties of LXe in the vacuum ultra violet (VUV), determining the performance of a scintillation calorimeter, are discussed in detail. The available data, measured in a wider spectral region from visible to UV light, and in a large range of Xe densities, from gas to liquid, are examined. It is shown that this information can be used for deriving the LXe optical properties in the VU…
▽ More
The optical properties of LXe in the vacuum ultra violet (VUV), determining the performance of a scintillation calorimeter, are discussed in detail. The available data, measured in a wider spectral region from visible to UV light, and in a large range of Xe densities, from gas to liquid, are examined. It is shown that this information can be used for deriving the LXe optical properties in the VUV. A comparison is made with the few direct measurements in LXe for VUV light resulting from the LXe excitation by ionizing particles. A useful relation is obtained which connects the Rayleigh scattering length to the refractive index in LXe.
△ Less
Submitted 15 January, 2004;
originally announced January 2004.
-
Force measurements of a superconducting-film actuator for a cryogenic interferometric gravitational-wave detector
Authors:
N. Sato,
T. Haruyama,
N. Kanda,
K. Kuroda,
S. Miyoki,
M. Ohashi,
Y. Saito,
T. Shintomi,
T. Suzuki,
D. Tatsumi,
C. Taylor,
T. Tomaru,
T. Uchiyama,
A. Yamamoto
Abstract:
We measured forces applied by an actuator with a YBCO film at near 77 K for the Large-scale Cryogenic Gravitational-wave Telescope (LCGT) project. An actuator consisting of both a YBCO film of 1.6 micrometers thickness and 0.81 square centimeters area and a solenoid coil exerted a force of up to 0.2 mN on a test mass. The presented actuator system can be used to displace the mirror of LCGT for f…
▽ More
We measured forces applied by an actuator with a YBCO film at near 77 K for the Large-scale Cryogenic Gravitational-wave Telescope (LCGT) project. An actuator consisting of both a YBCO film of 1.6 micrometers thickness and 0.81 square centimeters area and a solenoid coil exerted a force of up to 0.2 mN on a test mass. The presented actuator system can be used to displace the mirror of LCGT for fringe lock of the interferometer.
△ Less
Submitted 4 June, 2002;
originally announced June 2002.