Nano-fabricated solid immersion lenses registered to single emitters in diamond
Authors:
L. Marseglia,
J. P. Hadden,
A. C. Stanley-Clarke,
J. P. Harrison,
B. Patton,
Y. -L. D. Ho,
B. Naydenov,
F. Jelezko,
J. Meijer,
P. R. Dolan,
J. M. Smith,
J. G. Rarity,
J. L. O'Brien
Abstract:
We describe a technique for fabricating micro- and nano-structures incorporating fluorescent defects in diamond with a positional accuracy in the hundreds of nanometers. Using confocal fluorescence microscopy and focused ion beam (FIB) etching we first locate a suitable defect with respect to registration marks on the diamond surface and then etch a structure using these coordinates. We demonstrat…
▽ More
We describe a technique for fabricating micro- and nano-structures incorporating fluorescent defects in diamond with a positional accuracy in the hundreds of nanometers. Using confocal fluorescence microscopy and focused ion beam (FIB) etching we first locate a suitable defect with respect to registration marks on the diamond surface and then etch a structure using these coordinates. We demonstrate the technique here by etching an 8 micron diameter hemisphere positioned such that a single negatively charged nitrogen-vacancy defect lies at its origin. This type of structure increases the photon collection efficiency by removing refraction and aberration losses at the diamond-air interface. We make a direct comparison of the fluorescence photon count rate before and after fabrication and observe an 8-fold increase due to the presence of the hemisphere.
△ Less
Submitted 22 February, 2011; v1 submitted 6 December, 2010;
originally announced December 2010.
-
Strongly enhanced photon collection from diamond defect centres under micro-fabricated integrated solid immersion lenses
Authors:
J. P. Hadden,
J. P. Harrison,
A. C. Stanley-Clarke,
L. Marseglia,
Y-L. D. Ho,
B. R. Patton,
J. L. O'Brien,
J. G. Rarity
Abstract:
The efficiency of collecting photons from optically active defect centres in bulk diamond is greatly reduced by refraction and reflection at the diamond-air interface. We report on the fabrication and measurement of a geometrical solution to the problem; integrated solid immersion lenses (SILs) etched directly into the surface of diamond. An increase of a factor of 10 was observed in the saturated…
▽ More
The efficiency of collecting photons from optically active defect centres in bulk diamond is greatly reduced by refraction and reflection at the diamond-air interface. We report on the fabrication and measurement of a geometrical solution to the problem; integrated solid immersion lenses (SILs) etched directly into the surface of diamond. An increase of a factor of 10 was observed in the saturated count-rate from a single negatively charged nitrogen-vacancy (NV-) within a 5um diameter SIL compared with NV-s under a planar surface in the same crystal. A factor of 3 reduction in background emission was also observed due to the reduced excitation volume with a SIL present. Such a system is potentially scalable and easily adaptable to other defect centres in bulk diamond.
△ Less
Submitted 11 June, 2010; v1 submitted 10 June, 2010;
originally announced June 2010.
-
Cavity Enhanced Spin Measurement of an NV Centre in Diamond
Authors:
A. Young,
C. Y. Hu,
L. Marseglia,
J. P. Harrison,
J. L. O'Brien,
J. G. Rarity
Abstract:
We propose a high efficiency high fidelity measurement of the ground state spin of a single NV center in diamond, using the effects of cavity quantum electrodynamics. The scheme we propose is based in the one dimensional atom or Purcell regime, removing the need for high Q cavities that are challenging to fabricate. The ground state of the NV center consists of three spin levels $^{3}A_{(m=0)}$…
▽ More
We propose a high efficiency high fidelity measurement of the ground state spin of a single NV center in diamond, using the effects of cavity quantum electrodynamics. The scheme we propose is based in the one dimensional atom or Purcell regime, removing the need for high Q cavities that are challenging to fabricate. The ground state of the NV center consists of three spin levels $^{3}A_{(m=0)}$ and $^{3}A_{(m=\pm1)}$ (the $\pm1$ states are near degenerate in zero field). These two states can undergo transitions to the excited ($^{3}E$) state, with an energy difference of $\approx7-10$ $μ$eV between the two. By choosing the correct Q factor, this small detuning between the two transitions results in a dramatic change in the intensity of reflected light. We show the change in reflected intensity can allow us to read out the ground state spin using a low intensity laser with an error rate of $\approx5.5\times10^{-3}$, when realistic cavity and experimental parameters are considered. Since very low levels of light are used to probe the state of the spin we limit the number of florescence cycles, thereby limiting the non spin preserving transitions through the intermediate singlet state $^{1}A$.
△ Less
Submitted 1 July, 2008;
originally announced July 2008.
-
The nitrogen-vacancy center in diamond re-visited
Authors:
N. B. Manson,
J. P. Harrison,
M. J. Sellars
Abstract:
Symmetry considerations are used in presenting a model of the electronic structure and the associated dynamics of the nitrogen-vacancy center in diamond. The model accounts for the occurrence of optically induced spin polarization, for the change of emission level with spin polarization and for new measurements of transient emission. The rate constants given are in variance to those reported pre…
▽ More
Symmetry considerations are used in presenting a model of the electronic structure and the associated dynamics of the nitrogen-vacancy center in diamond. The model accounts for the occurrence of optically induced spin polarization, for the change of emission level with spin polarization and for new measurements of transient emission. The rate constants given are in variance to those reported previously.
△ Less
Submitted 5 June, 2006; v1 submitted 16 January, 2006;
originally announced January 2006.
-
Giant Thermomechanical Effect in Normal Liquid He-3
Authors:
D. L. Sawkey,
D. Deptuck,
D. Greenwood,
J. P. Harrison
Abstract:
Measurements are presented of the thermomechanical coefficient of normal liquid He-3 confined in a porous plug pre-plated with four monoloyers of He-4. These non-magnetic monolayers displace the magnetic solid-like He-3 monolayers that are adjacent to the pore surfaces when the plug is filled with pure He-3. In the low temperature limit (T < 10 mK) the coefficient can be described by dP/dT ~ s/6…
▽ More
Measurements are presented of the thermomechanical coefficient of normal liquid He-3 confined in a porous plug pre-plated with four monoloyers of He-4. These non-magnetic monolayers displace the magnetic solid-like He-3 monolayers that are adjacent to the pore surfaces when the plug is filled with pure He-3. In the low temperature limit (T < 10 mK) the coefficient can be described by dP/dT ~ s/6v, where dP is the pressure difference across the plug generated by the temperature difference dT and s and v are the molar entropy and volume. This low temperature limit corresponds to the condition d << l_q, where d is the pore diameter and l_q is the bulk liquid He-3 quasiparticle mean free path; that is, the quasiparticles are predominantly boundary scattered in the pores. The measured coefficient is half that calculated by Edwards, Culman and He. When compared with this new experimental result for the He-4 plated porous plug, the earlier result for pure liquid He-3 is strikingly larger (by up to 30x at 2 mK). This enhancement is reminiscent of the giant thermopowers measured in Kondo and other dilute magnetic alloys. It is speculated that the enhanced thermomechanical coefficient for pure liquid He-3 is due to magnetic scattering of the He-3 quasiparticles by the two magnetic solid-like He-3 monolayers adjacent to the pore surfaces.
△ Less
Submitted 12 December, 1997;
originally announced December 1997.