-
Batch VUV4 Characterization for the SBC-LAr10 scintillating bubble chamber
Authors:
H. Hawley-Herrera,
E. Alfonso-Pita,
E. Behnke,
M. Bressler,
B. Broerman,
K. Clark,
J. Corbett,
C. E. Dahl,
K. Dering,
A. de St. Croix,
D. Durnford,
P. Giampa,
J. Hall,
O. Harris,
N. Lamb,
M. Laurin,
I. Levine,
W. H. Lippincott,
X. Liu,
N. Moss,
R. Neilson,
M. -C. Piro,
D. Pyda,
Z. Sheng,
G. Sweeney
, et al. (6 additional authors not shown)
Abstract:
The Scintillating Bubble Chamber (SBC) collaboration purchased 32 Hamamatsu VUV4 silicon photomultipliers (SiPMs) for use in SBC-LAr10, a bubble chamber containing 10~kg of liquid argon. The VUV4 SiPMs, or Quads, underwent a characterization at two temperatures which measured the breakdown voltage ($V_{\text{BD}}$), the SiPM gain ($g_{\text{SiPM}}$), the rate of change of $g_{\text{SiPM}}$ with re…
▽ More
The Scintillating Bubble Chamber (SBC) collaboration purchased 32 Hamamatsu VUV4 silicon photomultipliers (SiPMs) for use in SBC-LAr10, a bubble chamber containing 10~kg of liquid argon. The VUV4 SiPMs, or Quads, underwent a characterization at two temperatures which measured the breakdown voltage ($V_{\text{BD}}$), the SiPM gain ($g_{\text{SiPM}}$), the rate of change of $g_{\text{SiPM}}$ with respect to voltage ($m$), the dark count rate (DCR), and the probability of a correlated avalanche (P$_{\text{CA}}$) as well as the temperature coefficients of these parameters. A Peltier-based chilled vacuum chamber was developed at Queen's University to cool down the Quads to $233.15\pm0.2$~K and $255.15\pm0.2$~K with average stability of $\pm20$~mK. A mostly assumption-free analysis was derived to estimate $V_{\text{BD}}$ to tens of mV precision and DCR close to Poissonian error. The temperature dependence of $V_{\text{BD}}$ was found to be $56\pm2$~mV~K$^{-1}$, and $m$ on average across all Quads was found to be $(459\pm3(\rm{stat.})\pm23(\rm{sys.}))\times 10^{3}~e^-$~PE$^{-1}$~V$^{-1}$. The average DCR temperature coefficient was estimated to be $0.099\pm0.008$~K$^{-1}$ corresponding to a reduction factor of 7 for every 20~K drop in temperature. The average temperature dependence of P$_{\text{CA}}$ was estimated to be $4000\pm1000$~ppm~K$^{-1}$. P$_{\text{CA}}$ estimated from the average across all SiPMs is a better estimator than the P$_{\text{CA}}$ calculated from individual SiPMs, whereas all of the other parameters, the opposite is true. All the estimated parameters were measured to the precision required for SBC-LAr10, and the Quads will be used in conditions to optimize the signal-to-noise ratio.
△ Less
Submitted 28 May, 2024;
originally announced May 2024.
-
Search for inelastic dark matter-nucleus scattering with the PICO-60 CF$_{3}$I and C$_{3}$F$_{8}$ bubble chambers
Authors:
E. Adams,
B. Ali,
I. J. Arnquist,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
C. J. Chen,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. Cripe,
M. Crisler,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
R. Filgas,
A. García Viltres,
G. Giroux,
O. Harris,
T. Hillier,
E. W. Hoppe,
C. M. Jackson,
M. **
, et al. (30 additional authors not shown)
Abstract:
PICO bubble chambers have exceptional sensitivity to inelastic dark matter-nucleus interactions due to a combination of their extended nuclear recoil energy detection window from a few keV to $O$(100 keV) or more and the use of iodine as a heavy target. Inelastic dark matter-nucleus scattering is interesting for studying the properties of dark matter, where many theoretical scenarios have been dev…
▽ More
PICO bubble chambers have exceptional sensitivity to inelastic dark matter-nucleus interactions due to a combination of their extended nuclear recoil energy detection window from a few keV to $O$(100 keV) or more and the use of iodine as a heavy target. Inelastic dark matter-nucleus scattering is interesting for studying the properties of dark matter, where many theoretical scenarios have been developed. This study reports the results of a search for dark matter inelastic scattering with the PICO-60 bubble chambers. The analysis reported here comprises physics runs from PICO-60 bubble chambers using CF$_{3}$I and C$_{3}$F$_{8}$. The CF$_{3}$I run consisted of 36.8 kg of CF$_{3}$I reaching an exposure of 3415 kg-day operating at thermodynamic thresholds between 7 and 20 keV. The C$_{3}$F$_{8}$ runs consisted of 52 kg of C$_{3}$F$_{8}$ reaching exposures of 1404 kg-day and 1167 kg-day running at thermodynamic thresholds of 2.45 keV and 3.29 keV, respectively. The analysis disfavors various scenarios, in a wide region of parameter space, that provide a feasible explanation of the signal observed by DAMA, assuming an inelastic interaction, considering that the PICO CF$_{3}$I bubble chamber used iodine as the target material.
△ Less
Submitted 21 January, 2023;
originally announced January 2023.
-
Snowmass 2021 Scintillating Bubble Chambers: Liquid-noble Bubble Chambers for Dark Matter and CE$ν$NS Detection
Authors:
E. Alfonso-Pita,
M. Baker,
E. Behnke,
A. Brandon,
M. Bressler,
B. Broerman,
K. Clark,
R. Coppejans,
J. Corbett,
C. Cripe,
M. Crisler,
C. E. Dahl,
K. Dering,
A. de St. Croix,
D. Durnford,
K. Foy,
P. Giampa,
J. Gresl,
J. Hall,
O. Harris,
H. Hawley-Herrera,
C. M. Jackson,
M. Khatri,
Y. Ko,
N. Lamb
, et al. (20 additional authors not shown)
Abstract:
The Scintillating Bubble Chamber (SBC) Collaboration is develo** liquid-noble bubble chambers for the quasi-background-free detection of low-mass (GeV-scale) dark matter and coherent scattering of low-energy (MeV-scale) neutrinos (CE$ν$NS). The first physics-scale demonstrator of this technique, a 10-kg liquid argon bubble chamber dubbed SBC-LAr10, is now being commissioned at Fermilab. This dev…
▽ More
The Scintillating Bubble Chamber (SBC) Collaboration is develo** liquid-noble bubble chambers for the quasi-background-free detection of low-mass (GeV-scale) dark matter and coherent scattering of low-energy (MeV-scale) neutrinos (CE$ν$NS). The first physics-scale demonstrator of this technique, a 10-kg liquid argon bubble chamber dubbed SBC-LAr10, is now being commissioned at Fermilab. This device will calibrate the background discrimination power and sensitivity of superheated argon to nuclear recoils at energies down to 100 eV. A second functionally-identical detector with a focus on radiopure construction is being built for SBC's first dark matter search at SNOLAB. The projected spin-independent sensitivity of this search is approximately $10^{-43}$ cm$^2$ at 1 GeV$/c^2$ dark matter particle mass. The scalability and background discrimination power of the liquid-noble bubble chamber make this technique a compelling candidate for future dark matter searches to the solar neutrino fog at 1 GeV$/c^2$ particle mass (requiring a $\sim$ton-year exposure with non-neutrino backgrounds sub-dominant to the solar CE$ν$NS signal) and for high-statistics CE$ν$NS studies at nuclear reactors.
△ Less
Submitted 29 September, 2022; v1 submitted 21 July, 2022;
originally announced July 2022.
-
Determining the bubble nucleation efficiency of low-energy nuclear recoils in superheated C$_3$F$_8$ dark matter detectors
Authors:
B. Ali,
I. J. Arnquist,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. Cripe,
M. Crisler,
C. E. Dahl,
M. Das,
D. Durnford,
S. Fallows,
J. Farine,
R. Filgas,
A. García-Viltres,
F. Girard,
G. Giroux,
O. Harris,
E. W. Hoppe,
C. M. Jackson,
M. **,
C. B. Krauss
, et al. (32 additional authors not shown)
Abstract:
The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massive particle (WIMP) dark matter. The PICO Collaboration presents the results of the efficiencies for bubble nucleation from carbon and fluorine recoils in superheated C$_3$F$_8$ from calibration data taken with 5 distinct…
▽ More
The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massive particle (WIMP) dark matter. The PICO Collaboration presents the results of the efficiencies for bubble nucleation from carbon and fluorine recoils in superheated C$_3$F$_8$ from calibration data taken with 5 distinct neutron spectra at various thermodynamic thresholds ranging from 2.1 keV to 3.9 keV. Instead of assuming any particular functional forms for the nuclear recoil efficiency, a generalized piecewise linear model is proposed with systematic errors included as nuisance parameters to minimize model-introduced uncertainties. A Markov-Chain Monte-Carlo (MCMC) routine is applied to sample the nuclear recoil efficiency for fluorine and carbon at 2.45 keV and 3.29 keV thermodynamic thresholds simultaneously. The nucleation efficiency for fluorine was found to be $\geq 50\, \%$ for nuclear recoils of 3.3 keV (3.7 keV) at a thermodynamic Seitz threshold of 2.45 keV (3.29 keV), and for carbon the efficiency was found to be $\geq 50\, \%$ for recoils of 10.6 keV (11.1 keV) at a threshold of 2.45 keV (3.29 keV). Simulated data sets are used to calculate a p-value for the fit, confirming that the model used is compatible with the data. The fit paradigm is also assessed for potential systematic biases, which although small, are corrected for. Additional steps are performed to calculate the expected interaction rates of WIMPs in the PICO-60 detector, a requirement for calculating WIMP exclusion limits.
△ Less
Submitted 7 November, 2022; v1 submitted 11 May, 2022;
originally announced May 2022.
-
Results on photon-mediated dark matter-nucleus interactions from the PICO-60 C$_{3}$F$_{8}$ bubble chamber
Authors:
B. Ali,
I. J. Arnquist,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
C. J. Chen,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. Cripe,
M. Crisler,
C. E. Dahl,
M. Das,
D. Durnford,
S. Fallows,
J. Farine,
R. Filgas,
A. García-Viltres,
G. Giroux,
O. Harris,
T. Hillier,
E. W. Hoppe,
C. M. Jackson,
M. **
, et al. (30 additional authors not shown)
Abstract:
Many compelling models predict dark matter coupling to the electromagnetic current through higher multipole interactions, while remaining electrically neutral. Different multipole couplings have been studied, among them anapole moment, electric and magnetic dipole moments, and millicharge. This study sets limits on the couplings for these photon-mediated interactions using non-relativistic contact…
▽ More
Many compelling models predict dark matter coupling to the electromagnetic current through higher multipole interactions, while remaining electrically neutral. Different multipole couplings have been studied, among them anapole moment, electric and magnetic dipole moments, and millicharge. This study sets limits on the couplings for these photon-mediated interactions using non-relativistic contact operators in an effective field theory framework. Using data from the PICO-60 bubble chamber leading limits for dark matter masses between 2.7 GeV/c$^2$ and 24 GeV/c$^2$ are reported for the coupling of these photon-mediated dark matter-nucleus interactions. The detector was filled with 52 kg of C$_3$F$_8$ operating at thermodynamic thresholds of 2.45 keV and 3.29 keV, reaching exposures of 1404 kg-day and 1167 kg-day, respectively.
△ Less
Submitted 21 April, 2022;
originally announced April 2022.
-
Effect of Differential Rotation on Magnetic Braking of Low-Mass and Solar-Like Stars: A Proof-of-Concept Study
Authors:
Lewis G. Ireland,
Sean P. Matt,
Charlie R. Davey,
Owain L. Harris,
Tobias W. Slade-Harajda,
Adam J. Finley,
Claudio Zanni
Abstract:
On the main sequence, low-mass and solar-like stars are observed to spin-down over time, and magnetized stellar winds are thought to be predominantly responsible for this significant angular momentum loss. Previous studies have demonstrated that the wind torque can be predicted via formulations dependent on stellar properties, such as magnetic field strength and geometry, stellar radius and mass,…
▽ More
On the main sequence, low-mass and solar-like stars are observed to spin-down over time, and magnetized stellar winds are thought to be predominantly responsible for this significant angular momentum loss. Previous studies have demonstrated that the wind torque can be predicted via formulations dependent on stellar properties, such as magnetic field strength and geometry, stellar radius and mass, wind mass-loss rate, and stellar rotation rate. Although these stars are observed to experience surface differential rotation, torque formulations so far have assumed solid-body rotation. Surface differential rotation is expected to affect the rotation of the wind and thus the angular momentum loss. To investigate how differential rotation affects the torque, we use the PLUTO code to perform 2.5D magnetohydrodynamic, axisymmetric simulations of stellar winds, using a colatitude-dependent surface differential rotation profile that is solar-like (i.e., rotation is slower at the poles than the equator). We demonstrate that the torque is determined by the average rotation rate in the wind, so that the net torque is less than that predicted by assuming solid-body rotation at the equatorial rate. The magnitude of the effect is essentially proportional to the magnitude of the surface differential rotation, for example, resulting in a torque for the Sun that is $\sim 20 \%$ smaller than predicted by the solid-body assumption. We derive and fit a semi-analytic formulation that predicts the torque as a function of the equatorial spin rate, magnitude of differential rotation, and wind magnetization (depending on the dipolar magnetic field strength and mass-loss rate, combined).
△ Less
Submitted 23 November, 2021; v1 submitted 22 November, 2021;
originally announced November 2021.
-
Physics reach of a low threshold scintillating argon bubble chamber in coherent elastic neutrino-nucleus scattering reactor experiments
Authors:
L. J. Flores,
Eduardo Peinado,
E. Alfonso-Pita,
K. Allen,
M. Baker,
E. Behnke,
M. Bressler,
K. Clark,
R. Coppejans,
C. Cripe,
M. Crisler,
C. E. Dahl,
A. de St. Croix,
D. Durnford,
P. Giampa,
O. Harris,
P. Hatch,
H. Hawley,
C. M. Jackson,
Y. Ko,
C. Krauss,
N. Lamb,
M. Laurin,
I. Levine,
W. H. Lippincott
, et al. (9 additional authors not shown)
Abstract:
The physics reach of a low threshold (100 eV) scintillating argon bubble chamber sensitive to Coherent Elastic neutrino-Nucleus Scattering (CE$ν$NS) from reactor neutrinos is studied. The sensitivity to the weak mixing angle, neutrino magnetic moment, and a light $Z'$ gauge boson mediator are analyzed. A Monte Carlo simulation of the backgrounds is performed to assess their contribution to the sig…
▽ More
The physics reach of a low threshold (100 eV) scintillating argon bubble chamber sensitive to Coherent Elastic neutrino-Nucleus Scattering (CE$ν$NS) from reactor neutrinos is studied. The sensitivity to the weak mixing angle, neutrino magnetic moment, and a light $Z'$ gauge boson mediator are analyzed. A Monte Carlo simulation of the backgrounds is performed to assess their contribution to the signal. The analysis shows that world-leading sensitivities are achieved with a one-year exposure for a 10 kg chamber at 3 m from a 1 MW$_{th}$ research reactor or a 100 kg chamber at 30 m from a 2000 MW$_{th}$ power reactor. Such a detector has the potential to become the leading technology to study CE$ν$NS using nuclear reactors.
△ Less
Submitted 26 May, 2021; v1 submitted 21 January, 2021;
originally announced January 2021.
-
Velocity independent constraints on spin-dependent DM-nucleon interactions from IceCube and PICO
Authors:
IceCube Collaboration,
M. G. Aartsen,
M. Ackermann,
J. Adams,
J. A. Aguilar,
M. Ahlers,
M. Ahrens,
C. Alispach,
K. Andeen,
T. Anderson,
I. Ansseau,
G. Anton,
C. Argüelles,
J. Auffenberg,
S. Axani,
P. Backes,
H. Bagherpour,
X. Bai,
A. Balagopal V.,
A. Barbano,
S. W. Barwick,
B. Bastian,
V. Baum,
S. Baur,
R. Bay
, et al. (398 additional authors not shown)
Abstract:
Adopting the Standard Halo Model (SHM) of an isotropic Maxwellian velocity distribution for dark matter (DM) particles in the Galaxy, the most stringent current constraints on their spin-dependent scattering cross-section with nucleons come from the IceCube neutrino observatory and the PICO-60 C$_3$F$_8$ superheated bubble chamber experiments. The former is sensitive to high energy neutrinos from…
▽ More
Adopting the Standard Halo Model (SHM) of an isotropic Maxwellian velocity distribution for dark matter (DM) particles in the Galaxy, the most stringent current constraints on their spin-dependent scattering cross-section with nucleons come from the IceCube neutrino observatory and the PICO-60 C$_3$F$_8$ superheated bubble chamber experiments. The former is sensitive to high energy neutrinos from the self-annihilation of DM particles captured in the Sun, while the latter looks for nuclear recoil events from DM scattering off nucleons. Although slower DM particles are more likely to be captured by the Sun, the faster ones are more likely to be detected by PICO. Recent N-body simulations suggest significant deviations from the SHM for the smooth halo component of the DM, while observations hint at a dominant fraction of the local DM being in substructures. We use the method of Ferrer et al. (2015) to exploit the complementarity between the two approaches and derive conservative constraints on DM-nucleon scattering. Our results constrain $σ_{\mathrm{SD}} \lesssim 3 \times 10^{-39} \mathrm{cm}^2$ (6 $ \times 10^{-38} \mathrm{cm}^2$) at $\gtrsim 90\%$ C.L. for a DM particle of mass 1~TeV annihilating into $τ^+ τ^-$ ($b\bar{b}$) with a local density of $ρ_{\mathrm{DM}} = 0.3~\mathrm{ GeV/cm}^3$. The constraints scale inversely with $ρ_{\mathrm{DM}}$ and are independent of the DM velocity distribution.
△ Less
Submitted 25 May, 2020; v1 submitted 29 July, 2019;
originally announced July 2019.
-
Data-Driven Modeling of Electron Recoil Nucleation in PICO C$_3$F$_8$ Bubble Chambers
Authors:
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
G. Cao,
C. J. Chen,
S. Chen,
U. Chowdhury,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. B. Coutu,
C. Cowles,
M. Crisler,
G. Crowder,
N. A. Cruz-Venegas,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
R. Filgas
, et al. (54 additional authors not shown)
Abstract:
The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from WIMP dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one driven by…
▽ More
The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from WIMP dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one driven by a hot-spike as previously supposed. Using this semi-empirical model, bubble chamber nucleation thresholds may be tuned to be sensitive to lower energy nuclear recoils while maintaining excellent electron recoil rejection. The PICO-40L detector will exploit this model to achieve thermodynamic thresholds as low as 2.8 keV while being dominated by single-scatter events from coherent elastic neutrino-nucleus scattering of solar neutrinos. In one year of operation, PICO-40L can improve existing leading limits from PICO on spin-dependent WIMP-proton coupling by nearly an order of magnitude for WIMP masses greater than 3 GeV c$^{-2}$ and will have the ability to surpass all existing non-xenon bounds on spin-independent WIMP-nucleon coupling for WIMP masses from 3 to 40 GeV c$^{-2}$.
△ Less
Submitted 25 November, 2020; v1 submitted 29 May, 2019;
originally announced May 2019.
-
Dark Matter Search Results from the Complete Exposure of the PICO-60 C$_3$F$_8$ Bubble Chamber
Authors:
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
G. Cao,
C. J. Chen,
U. Chowdhury,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. B. Coutu,
C. Cowles,
M. Crisler,
G. Crowder,
N. A. Cruz-Venegas,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
I. Felis,
R. Filgas
, et al. (47 additional authors not shown)
Abstract:
Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total backgr…
▽ More
Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total background rate as the previous 1167-kg-day exposure at 3.3 keV. This increased exposure is enabled in part by a new optical tracking analysis to better identify events near detector walls, permitting a larger fiducial volume. These results set the most stringent direct-detection constraint to date on the WIMP-proton spin-dependent cross section at 2.5 $\times$ 10$^{-41}$ cm$^2$ for a 25 GeV WIMP, and improve on previous PICO results for 3-5 GeV WIMPs by an order of magnitude.
△ Less
Submitted 11 February, 2019;
originally announced February 2019.
-
Develo** a Bubble Chamber Particle Discriminator Using Semi-Supervised Learning
Authors:
B. Matusch,
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
G. Cao,
C. J. Chen,
U. Chowdhury,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. B. Coutu,
C. Cowles,
M. Crisler,
G. Crowder,
N. A. Cruz-Venegas,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
I. Felis
, et al. (48 additional authors not shown)
Abstract:
The identification of non-signal events is a major hurdle to overcome for bubble chamber dark matter experiments such as PICO-60. The current practice of manually develo** a discriminator function to eliminate background events is difficult when available calibration data is frequently impure and present only in small quantities. In this study, several different discriminator input/preprocessing…
▽ More
The identification of non-signal events is a major hurdle to overcome for bubble chamber dark matter experiments such as PICO-60. The current practice of manually develo** a discriminator function to eliminate background events is difficult when available calibration data is frequently impure and present only in small quantities. In this study, several different discriminator input/preprocessing formats and neural network architectures are applied to the task. First, they are optimized in a supervised learning context. Next, two novel semi-supervised learning algorithms are trained, and found to replicate the Acoustic Parameter (AP) discriminator previously used in PICO-60 with a mean of 97% accuracy.
△ Less
Submitted 27 November, 2018;
originally announced November 2018.
-
Dark Matter Search Results from the PICO-60 C$_3$F$_8$ Bubble Chamber
Authors:
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
P. Bhattacharjee,
H. Borsodi,
M. Bou-Cabo,
P. Campion,
G. Cao,
C. J. Chen,
U. Chowdhury,
K. Clark,
J. I. Collar,
P. S. Cooper,
M. Crisler,
G. Crowder,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
I. Felis,
R. Filgas,
F. Girard
, et al. (37 additional authors not shown)
Abstract:
New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60 C$_3$F$_8$ exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less th…
▽ More
New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60 C$_3$F$_8$ exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less than 1 event per month. A blind analysis of an efficiency-corrected 1167-kg-day exposure at a 3.3-keV thermodynamic threshold reveals no single-scattering nuclear recoil candidates, consistent with the predicted background. These results set the most stringent direct-detection constraint to date on the WIMP-proton spin-dependent cross section at 3.4 $\times$ 10$^{-41}$ cm$^2$ for a 30-GeV$\thinspace$c$^{-2}$ WIMP, more than one order of magnitude improvement from previous PICO results.
△ Less
Submitted 2 August, 2017; v1 submitted 24 February, 2017;
originally announced February 2017.
-
Improved dark matter search results from PICO-2L Run 2
Authors:
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
P. Bhattacharjee,
H. Borsodi,
M. Bou-Cabo,
S. J. Brice,
D. Broemmelsiek,
K. Clark,
J. I. Collar,
P. S. Cooper,
M. Crisler,
C. E. Dahl,
M. Das,
F. Debris,
S. Fallows,
J. Farine,
I. Felis,
R. Filgas,
M. Fines-Neuschild,
F. Girard,
G. Giroux
, et al. (33 additional authors not shown)
Abstract:
New data are reported from a second run of the 2-liter PICO-2L C$_3$F$_8$ bubble chamber with a total exposure of 129$\,$kg-days at a thermodynamic threshold energy of 3.3$\,$keV. These data show that measures taken to control particulate contamination in the superheated fluid resulted in the absence of the anomalous background events observed in the first run of this bubble chamber. One single nu…
▽ More
New data are reported from a second run of the 2-liter PICO-2L C$_3$F$_8$ bubble chamber with a total exposure of 129$\,$kg-days at a thermodynamic threshold energy of 3.3$\,$keV. These data show that measures taken to control particulate contamination in the superheated fluid resulted in the absence of the anomalous background events observed in the first run of this bubble chamber. One single nuclear-recoil event was observed in the data, consistent both with the predicted background rate from neutrons and with the observed rate of unambiguous multiple-bubble neutron scattering events. The chamber exhibits the same excellent electron-recoil and alpha decay rejection as was previously reported. These data provide the most stringent direct detection constraints on weakly interacting massive particle (WIMP)-proton spin-dependent scattering to date for WIMP masses $<$ 50$\,$GeV/c$^2$.
△ Less
Submitted 25 March, 2016; v1 submitted 14 January, 2016;
originally announced January 2016.
-
Dark Matter Search Results from the PICO-60 CF$_3$I Bubble Chamber
Authors:
C. Amole,
M. Ardid,
D. M. Asner,
D. Baxter,
E. Behnke,
P. Bhattacharjee,
H. Borsodi,
M. Bou-Cabo,
S. J. Brice,
D. Broemmelsiek,
K. Clark,
J. I. Collar,
P. S. Cooper,
M. Crisler,
C. E. Dahl,
S. Daley,
M. Das,
F. Debris,
N. Dhungana,
J. Farine,
I. Felis,
R. Filgas,
F. Girard,
G. Giroux,
A. Grandison
, et al. (34 additional authors not shown)
Abstract:
New data are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 36.8 kg of CF$_3$I and located in the SNOLAB underground laboratory. PICO-60 is the largest bubble chamber to search for dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60 exhibits the same excellent background rejection observed in smaller bubble chambers. Alpha decays…
▽ More
New data are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 36.8 kg of CF$_3$I and located in the SNOLAB underground laboratory. PICO-60 is the largest bubble chamber to search for dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60 exhibits the same excellent background rejection observed in smaller bubble chambers. Alpha decays in PICO-60 exhibit frequency-dependent acoustic calorimetry, similar but not identical to that reported recently in a C$_3$F$_8$ bubble chamber. PICO-60 also observes a large population of unknown background events, exhibiting acoustic, spatial, and timing behaviors inconsistent with those expected from a dark matter signal. These behaviors allow for analysis cuts to remove all background events while retaining $48.2\%$ of the exposure. Stringent limits on weakly interacting massive particles interacting via spin-dependent proton and spin-independent processes are set, and most interpretations of the DAMA/LIBRA modulation signal as dark matter interacting with iodine nuclei are ruled out.
△ Less
Submitted 3 March, 2016; v1 submitted 26 October, 2015;
originally announced October 2015.
-
Dark Matter Search Results from the PICO-2L C$_3$F$_8$ Bubble Chamber
Authors:
C. Amole,
M. Ardid,
D. M. Asner,
D. Baxter,
E. Behnke,
P. Bhattacharjee,
H. Borsodi,
M. Bou-Cabo,
S. J. Brice,
D. Broemmelsiek,
K. Clark,
J. I. Collar,
P. S. Cooper,
M. Crisler,
C. E. Dahl,
S. Daley,
M. Das,
F. Debris,
N. Dhungana,
J. Farine,
I. Felis,
R. Filgas,
M. Fines-Neuschild,
F. Girard,
G. Giroux
, et al. (32 additional authors not shown)
Abstract:
New data are reported from the operation of a 2-liter C$_3$F$_8$ bubble chamber in the 2100 meter deep SNOLAB underground laboratory, with a total exposure of 211.5 kg-days at four different recoil energy thresholds ranging from 3.2 keV to 8.1 keV. These data show that C3F8 provides excellent electron recoil and alpha rejection capabilities at very low thresholds, including the first observation o…
▽ More
New data are reported from the operation of a 2-liter C$_3$F$_8$ bubble chamber in the 2100 meter deep SNOLAB underground laboratory, with a total exposure of 211.5 kg-days at four different recoil energy thresholds ranging from 3.2 keV to 8.1 keV. These data show that C3F8 provides excellent electron recoil and alpha rejection capabilities at very low thresholds, including the first observation of a dependence of acoustic signal on alpha energy. Twelve single nuclear recoil event candidates were observed during the run. The candidate events exhibit timing characteristics that are not consistent with the hypothesis of a uniform time distribution, and no evidence for a dark matter signal is claimed. These data provide the most sensitive direct detection constraints on WIMP-proton spin-dependent scattering to date, with significant sensitivity at low WIMP masses for spin-independent WIMP-nucleon scattering.
△ Less
Submitted 29 June, 2015; v1 submitted 27 February, 2015;
originally announced March 2015.
-
Observation of inhibited electron-ion coupling in strongly heated graphite
Authors:
T. G. White,
J. Vorberger,
C. R. D. Brown,
B. J. B. Crowley,
P. Davis,
S. H. Glenzer,
J. W. O. Harris,
D. C. Hochhaus,
S. Le Pape,
T. Ma,
C. D. Murphy,
P. Neumayer,
L. K. Pattison,
S. Richardson,
D. O. Gericke,
G. Gregori
Abstract:
Creating non-equilibrium states of matter with highly unequal electron and lattice temperatures allows unsurpassed insight into the dynamic coupling between electrons and ions through time-resolved energy relaxation measurements. Recent studies on low-temperature laser-heated graphite suggest a complex energy exchange when compared to other materials. To avoid problems related to surface preparati…
▽ More
Creating non-equilibrium states of matter with highly unequal electron and lattice temperatures allows unsurpassed insight into the dynamic coupling between electrons and ions through time-resolved energy relaxation measurements. Recent studies on low-temperature laser-heated graphite suggest a complex energy exchange when compared to other materials. To avoid problems related to surface preparation, crystal quality and poor understanding of the energy deposition and transport mechanisms, we apply a different energy deposition mechanism, via laser-accelerated protons, to isochorically and non-radiatively heat macroscopic graphite samples up to temperatures close to the melting threshold. Using time-resolved x ray diffraction, we show clear evidence of a very small electron-ion energy transfer, yielding approximately three times longer relaxation times than previously reported. This is indicative of the existence of an energy transfer bottleneck in non-equilibrium warm dense matter.
△ Less
Submitted 6 March, 2013;
originally announced March 2013.
-
Expected Performance of the ATLAS Experiment - Detector, Trigger and Physics
Authors:
The ATLAS Collaboration,
G. Aad,
E. Abat,
B. Abbott,
J. Abdallah,
A. A. Abdelalim,
A. Abdesselam,
O. Abdinov,
B. Abi,
M. Abolins,
H. Abramowicz,
B. S. Acharya,
D. L. Adams,
T. N. Addy,
C. Adorisio,
P. Adragna,
T. Adye,
J. A. Aguilar-Saavedra,
M. Aharrouche,
S. P. Ahlen,
F. Ahles,
A. Ahmad,
H. Ahmed,
G. Aielli,
T. Akdogan
, et al. (2587 additional authors not shown)
Abstract:
A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on…
▽ More
A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on simulations of the detector and physics processes, with particular emphasis given to the data expected from the first years of operation of the LHC at CERN.
△ Less
Submitted 14 August, 2009; v1 submitted 28 December, 2008;
originally announced January 2009.