-
Correlations between X-rays, Visible Light and Drive-Beam Energy Loss Observed in Plasma Wakefield Acceleration Experiments at FACET-II
Authors:
Chaojie Zhang,
Doug Storey,
Pablo San Miguel Claveria,
Zan Nie,
Ken A. Marsh,
Warren B. Mori,
Erik Adli,
Weiming An,
Robert Ariniello,
Gevy J. Cao,
Christine Clark,
Sebastien Corde,
Thamine Dalichaouch,
Christopher E. Doss,
Claudio Emma,
Henrik Ekerfelt,
Elias Gerstmayr,
Spencer Gessner,
Claire Hansel,
Alexander Knetsch,
Valentina Lee,
Fei Li,
Mike Litos,
Brendan O'Shea,
Glen White
, et al. (4 additional authors not shown)
Abstract:
This study documents several correlations observed during the first run of the plasma wakefield acceleration experiment E300 conducted at FACET-II, using a single drive electron bunch. The established correlations include those between the measured maximum energy loss of the drive electron beam and the integrated betatron x-ray signal, the calculated total beam energy deposited in the plasma and t…
▽ More
This study documents several correlations observed during the first run of the plasma wakefield acceleration experiment E300 conducted at FACET-II, using a single drive electron bunch. The established correlations include those between the measured maximum energy loss of the drive electron beam and the integrated betatron x-ray signal, the calculated total beam energy deposited in the plasma and the integrated x-ray signal, among three visible light emission measuring cameras, and between the visible plasma light and x-ray signal. The integrated x-ray signal correlates almost linearly with both the maximum energy loss of the drive beam and the energy deposited into the plasma, demonstrating its usability as a measure of energy transfer from the drive beam to the plasma. Visible plasma light is found to be a useful indicator of the presence of wake at three locations that overall are two meters apart. Despite the complex dynamics and vastly different timescales, the x-ray radiation from the drive bunch and visible light emission from the plasma may prove to be effective non-invasive diagnostics for monitoring the energy transfer from the beam to the plasma in future high-repetition-rate experiments.
△ Less
Submitted 29 April, 2024;
originally announced April 2024.
-
Generation of meter-scale hydrogen plasmas and efficient, pump-depletion-limited wakefield excitation using 10 GeV electron bunches
Authors:
C. Zhang,
D. Storey,
P. San Miguel Claveria,
Z. Nie,
K. A. Marsh,
M. Hogan,
W. B. Mori,
E. Adli,
W. An,
R. Ariniello,
G. J. Cao,
C. Clarke,
S. Corde,
T. Dalichaouch,
C. E. Doss,
C. Emma,
H. Ekerfelt,
E. Gerstmayr,
S. Gessner,
C. Hansel,
A. Knetsch,
V. Lee,
F. Li,
M. Litos,
B. O'Shea
, et al. (4 additional authors not shown)
Abstract:
High repetition rates and efficient energy transfer to the accelerating beam are important for a future linear collider based on the beam-driven plasma wakefield acceleration scheme (PWFA-LC). This paper reports the first results from the Plasma Wakefield Acceleration Collaboration (E300) that are beginning to address both of these issues using the recently commissioned FACET-II facility at SLAC.…
▽ More
High repetition rates and efficient energy transfer to the accelerating beam are important for a future linear collider based on the beam-driven plasma wakefield acceleration scheme (PWFA-LC). This paper reports the first results from the Plasma Wakefield Acceleration Collaboration (E300) that are beginning to address both of these issues using the recently commissioned FACET-II facility at SLAC. We have generated meter-scale hydrogen plasmas using time-structured 10 GeV electron bunches from FACET-II, which hold the promise of dramatically increasing the repetition rate of PWFA by rapidly replenishing the gas between each shot compared to the hitherto used lithium plasmas that operate at 1-10 Hz. Furthermore, we have excited wakes in such plasmas that are suitable for high gradient particle acceleration with high drive-bunch to wake energy transfer efficiency -- a first step in achieving a high overall energy transfer efficiency. We have done this by using time-structured electron drive bunches that typically have one or more ultra-high current (>30 kA) femtosecond spike(s) superimposed on a longer (~0.4 ps) lower current (<10 kA) bunch structure. The first spike effectively field-ionizes the gas and produces a meter-scale (30-160 cm) plasma, whereas the subsequent beam charge creates a wake. The length and amplitude of the wake depends on the longitudinal current profile of the bunch and plasma density. We find that the onset of pump depletion, when some of the drive beam electrons are nearly fully depleted of their energy, occurs for hydrogen pressure >1.5 Torr. We also show that some electrons in the rear of the bunch can gain several GeV energies from the wake. These results are reproduced by particle-in-cell simulations using the QPAD code. At a pressure of ~2 Torr, simulations results and experimental data show that the beam transfers about 60% of its energy to the wake.
△ Less
Submitted 9 October, 2023;
originally announced October 2023.
-
Temporal Evolution of the Light Emitted by a Thin, Laser-ionized Plasma Source
Authors:
Valentina Lee,
Robert Ariniello,
Christopher Doss,
Kathryn Wolfinger,
Peter Stoltz,
Claire Hansel,
Spencer Gessner,
John Cary,
Michael Litos
Abstract:
We present an experimental and simulation-based investigation of the temporal evolution of light emission from a thin, laser-ionized Helium plasma source. We demonstrate an analytic model to calculate the approximate scaling of the time-integrated, on-axis light emission with the initial plasma density and temperature, supported by the experiment, which enhances the understanding of plasma light m…
▽ More
We present an experimental and simulation-based investigation of the temporal evolution of light emission from a thin, laser-ionized Helium plasma source. We demonstrate an analytic model to calculate the approximate scaling of the time-integrated, on-axis light emission with the initial plasma density and temperature, supported by the experiment, which enhances the understanding of plasma light measurement for plasma wakefield accelerator (PWFA) plasma sources. Our model simulates the plasma density and temperature using a split-step Fourier code and a particle-in-cell (PIC) code. A fluid simulation is then used to model the plasma and neutral density, and the electron temperature as a function of time and position. We then show the numerical results of the space-and-time-resolved light emission and that collisional excitation is the dominant source of light emission. We validate our model by measuring the light emitted by a laser-ionized plasma using a novel statistical method capable of resolving the nanosecond-scale temporal dynamics of the plasma light using a cost-effective camera with microsecond-scale timing jitter. This method is ideal for deployment in the high radiation environment of a particle accelerator that precludes the use of expensive nanosecond-gated cameras. Our results show that our models can effectively simulate the dynamics of a thin, laser-ionized plasma source and this work is useful to understand the plasma light measurement, which plays an important role in the PWFA.
△ Less
Submitted 16 September, 2023;
originally announced September 2023.
-
Modeling betatron radiation using particle-in-cell codes for plasma wakefield accelerator diagnostics
Authors:
M. Yadav,
C. Hansel,
B. Naranjo,
G. Andonian,
P. Manwani,
O. Apsimon,
C. P. Welsch,
J. B. Rosenzweig
Abstract:
The characterization of plasma wakefield acceleration experiments using emitted photons from betatron radiation requires numerical models in support of instrumentation of single-shot, double-differential angular-energy spectra. Precision characterization for relevant experiments necessitates covering a wide energy range extending from tens of keV through 10~GeV, with an angular resolution on the o…
▽ More
The characterization of plasma wakefield acceleration experiments using emitted photons from betatron radiation requires numerical models in support of instrumentation of single-shot, double-differential angular-energy spectra. Precision characterization for relevant experiments necessitates covering a wide energy range extending from tens of keV through 10~GeV, with an angular resolution on the order of $100 \;μ\text{rad}$. In this paper, we present a numerical model for betatron radiation from plasma accelerated beams, that are based on integration of Lienard Wiechert (LW) potentials for computed particle trajectories. The particle trajectories are generated in three different ways: first, by particle tracking through idealized fields in the blowout regime of PWFA; second, by obtaining trajectories from the Quasi-static Particle-in-Cell (PIC) code QuickPIC; and third, by obtaining trajectories from the full PIC code OSIRIS. We performed various benchmarks with analytical expressions and the PIC code EPOCH, which uses a Monte-Carlo QED radiation model. Finally, we present simulations of the expected betatron radiation for parameters from the Facility for Advanced Accelerator Experimental Tests II (FACET-II) PWFA and plasma photocathode experiments.
△ Less
Submitted 7 March, 2023;
originally announced March 2023.
-
Chromatic Dynamics of an Electron Beam in a Plasma Based Accelerator
Authors:
R. Ariniello,
C. E. Doss,
V. Lee,
C. Hansel,
J. R. Cary,
M. D. Litos
Abstract:
We present a theoretical investigation of the chromatic dynamics of the witness beam within a plasma based accelerator. We derive the single particle motion of an electron in an ion column within a nonlinear, blowout wake including adiabatic dampening and adiabatic variations in plasma density. Using this, we calculate the evolution of the beam moments and emittance for an electron beam. Our model…
▽ More
We present a theoretical investigation of the chromatic dynamics of the witness beam within a plasma based accelerator. We derive the single particle motion of an electron in an ion column within a nonlinear, blowout wake including adiabatic dampening and adiabatic variations in plasma density. Using this, we calculate the evolution of the beam moments and emittance for an electron beam. Our model can handle near arbitrary longitudinal phase space distributions. We include the effects of energy change in the beam, imperfect wake loading, initial transverse offsets of the beam, and mismatch between the beam and plasma. We use our model to derive analytic saturation lengths for the projected, longitudinal slice, and energy slice emittance under different beam loading conditions. Further, we show that the centroid oscillations and spot sizes vary between the slices and the variation depends strongly on the beam loading. Next, we show how a beam evolves in a full plasma source with density ramps and show that the integral of the plasma density along the ramp determines the impact on the beam. Finally, we derive several simple scaling laws that show how to design a plasma based injector to produce a target beam energy and energy spread.
△ Less
Submitted 3 November, 2021;
originally announced November 2021.
-
Favorable Interfacial Chemomechanics Enables Stable Cycling of High Li-Content Li-In/Sn Anodes in Sulfide Electrolyte Based Solid-State Batteries
Authors:
Christian Hänsel,
Baltej Singh,
David Kiwic,
Pieremanuele Canepa,
Dipan Kundu
Abstract:
Solid-state batteries (SSBs) can offer a paradigm shift in battery safety and energy density. Yet, the promise hinges on the ability to integrate high-performance electrodes with state-of-the-art solid electrolytes. For example, lithium (Li) metal, the most energy-dense anode candidate, suffers from severe interfacial chemomechanical issues that lead to cell failure. Li alloys of In/Sn are attract…
▽ More
Solid-state batteries (SSBs) can offer a paradigm shift in battery safety and energy density. Yet, the promise hinges on the ability to integrate high-performance electrodes with state-of-the-art solid electrolytes. For example, lithium (Li) metal, the most energy-dense anode candidate, suffers from severe interfacial chemomechanical issues that lead to cell failure. Li alloys of In/Sn are attractive alternatives, but their exploration has mostly been limited to the low capacity(low Li content)and In rich Li$_x$In (x$\leq$0.5). Here, the fundamental electro-chemo-mechanical behavior of Li-In and Li-Sn alloys of varied Li stoichiometries is unravelled in sulfide electrolyte based SSBs. The intermetallic electrodes developed through a controlled synthesis and fabrication technique display impressive (electro)chemical stability with Li$_6$PS$_5$Cl as the solid electrolyte and maintain nearly perfect interfacial contact during the electrochemical Li insertion/deinsertion under an optimal stack pressure. Their intriguing variation in the Li migration barrier with composition and its influence on the observed Li cycling overpotential is revealed through combined computational and electrochemical studies. Stable interfacial chemomechanics of the alloys allow long-term dendrite free Li cycling (>1000 h) at relatively high current densities (1 mA cm$^{-2}$) and capacities (1 mAh cm$^{-2}$), as demonstrated for Li$_{13}$In$_3$ and Li$_{17}$Sn$_4$, which are more desirable from a capacity and cost consideration compared to the low Li content analogues. The presented understanding can guide the development of high-capacity Li-In/Sn alloy anodes for SSBs.
△ Less
Submitted 22 July, 2021;
originally announced August 2021.
-
Modeling Betatron Radiation Diagnostics for E-310 -- Trojan Horse
Authors:
M. Yadav,
C. Hansel,
Y. Zhuang,
B. Naranjo,
N. Majernik,
A. Perera,
Y. Sakai,
G. Andonian,
O. Williams,
P. Manwani,
J. Resta-Lopez,
O. Apsimon,
C. Welsch,
B. Hidding,
J. Rosenzweig
Abstract:
The E-310 experiment at the Facility for Advanced Accelerator Experimental Tests II (FACET-II) at SLAC National Accelerator Laboratory aims to demonstrate the creation of high brightness beams from a plasma photocathode. Betatron radiation will be measured by a Compton spectrometer, currently under development at UCLA, to provide single-shot, nondestructive beam diagnostics. We give a brief overvi…
▽ More
The E-310 experiment at the Facility for Advanced Accelerator Experimental Tests II (FACET-II) at SLAC National Accelerator Laboratory aims to demonstrate the creation of high brightness beams from a plasma photocathode. Betatron radiation will be measured by a Compton spectrometer, currently under development at UCLA, to provide single-shot, nondestructive beam diagnostics. We give a brief overview of this spectrometer as well as double differential spectrum reconstruction from the spectrometer image and beam parameter reconstruction from this double differential spectrum. We discuss three models for betatron radiation: an idealized particle tracking code which computes radiation from Liénard-Wiechert potentials, a quasi-static particle-in-cell (PIC) code which computes radiation from Liénard-Wiechert potentials, and a full PIC code which computes radiation using a Monte Carlo QED method. Spectra computed by the three models for a simple case are compared.
△ Less
Submitted 30 June, 2021;
originally announced July 2021.
-
Plasma Wakefield Accelerators with Ion Motion and the E-314 Experiment at FACET-II
Authors:
C. Hansel,
M. Yadav,
P. Manwani,
W. An,
W. Mori,
J. Rosenzweig
Abstract:
A future plasma based linear collider has the potential to reach unprecedented energies and transform our understanding of high energy physics. The extremely dense beams in such a device would cause the plasma ions to fall toward the axis. For more mild ion motion, this introduces a nonlinear perturbation to the focusing fields inside of the bubble. However, for extreme ion motion, the ion distrib…
▽ More
A future plasma based linear collider has the potential to reach unprecedented energies and transform our understanding of high energy physics. The extremely dense beams in such a device would cause the plasma ions to fall toward the axis. For more mild ion motion, this introduces a nonlinear perturbation to the focusing fields inside of the bubble. However, for extreme ion motion, the ion distribution collapses to a quasi-equilibrium characterized by a thin filament of extreme density on the axis which generates strong, nonlinear focusing fields. These fields can provoke unacceptable emittance growth that can be reduced through careful beam matching. In this paper, we discuss the rich physics of ion motion, give a brief overview of plans for the E-314 experiment at FACET-II which will experimentally demonstrate ion motion in plasma accelerators, and present results of particle-in-cell simulations of ion motion relevant to the E-314 experiment.
△ Less
Submitted 30 June, 2021;
originally announced July 2021.
-
Nonlinear equilibria and emittance growth in plasma wakefield accelerators with ion motion
Authors:
C. Hansel,
W. An,
W. Mori,
J. B. Rosenzweig
Abstract:
The plasma wakefield accelerator may accelerate particles to high energy in a future linear collider with unprecedented acceleration gradients, exceeding the GeV/m range. Beams for this application would have extremely high brightness and, subject to the intense plasma ion-derived focusing, they would achieve densities high enough to induce the plasma ions to collapse into the beam volume. This no…
▽ More
The plasma wakefield accelerator may accelerate particles to high energy in a future linear collider with unprecedented acceleration gradients, exceeding the GeV/m range. Beams for this application would have extremely high brightness and, subject to the intense plasma ion-derived focusing, they would achieve densities high enough to induce the plasma ions to collapse into the beam volume. This non-uniform ion density gives rise to strong nonlinear focusing which may lead to deleterious beam emittance growth. The effects of ion collapse and their mitigation has been investigated recently through particle-in-cell simulations, which show that by dynamically matching the beam to the focusing of the collapsed ion distribution, one may avoid serious emittance growth. We extend this work by exploring the near-equilibrium state of the beam-ion system reached after the ions have collapsed, a condition yielding the emittance growth mitigation observed. We show through PIC simulations and analytical theory that in this case a dual electron beam-ion Bennett-type equilibrium distribution is approached. Here, the beam and ion distributions share nearly the same shape, which generates nonlinear transverse electromagnetic fields. We exploit a Bennett-type model to study beam phase space dynamics and emittance growth over time scales much longer than permitted by PIC simulations through use of a 2D symplectic tracking code with Monte Carlo scattering based on Moliere's theory of small angle multiple scattering. We find that while phase space diffusion due to parametric excitations of the beam size due to plasma non-uniformity is negligible, scattering from collapsed ions gives rise to manageable emittance growth in the case of a linear collider. The implications of these results on experiments planned at FACET-II are examined.
△ Less
Submitted 27 March, 2020; v1 submitted 26 March, 2020;
originally announced March 2020.
-
Single-Shot Characterization of High Transformer Ratio Wakefields in Nonlinear Plasma Acceleration
Authors:
Ryan Roussel,
Gerard Andonian,
Walter Lynn,
Kunal Sanwalka,
River Robles,
Claire Hansel,
Aihua Deng,
Gerard Lawler,
James Rosenzweig
Abstract:
Plasma wakefields can enable very high accelerating gradients for frontier high energy particle accelerators, in excess of 10 GeV/m. To overcome limits on total acceleration achievable, specially shaped drive beams can be used in both linear and nonlinear plasma wakefield accelerators (PWFA), to increase the transformer ratio, implying that the drive beam deceleration is minimized relative to acce…
▽ More
Plasma wakefields can enable very high accelerating gradients for frontier high energy particle accelerators, in excess of 10 GeV/m. To overcome limits on total acceleration achievable, specially shaped drive beams can be used in both linear and nonlinear plasma wakefield accelerators (PWFA), to increase the transformer ratio, implying that the drive beam deceleration is minimized relative to acceleration obtained in the wake. In this Letter, we report the results of a nonlinear PWFA, high transformer ratio experiment using high-charge, longitudinally asymmetric drive beams in a plasma cell. An emittance exchange process is used to generate variable drive current profiles, in conjunction with a long (multiple plasma wavelength) witness beam. The witness beam is energy-modulated by the wakefield, yielding a response that contains detailed spectral information in a single-shot measurement. Using these methods, we generate a variety of beam profiles and characterize the wakefields, directly observing beam-loaded transformer ratios up to R=7.8. Furthermore, a spectrally-based reconstruction technique, validated by 3D particle-in-cell simulations, is introduced to obtain the drive beam current profile from the decelerating wake data.
△ Less
Submitted 18 October, 2019;
originally announced October 2019.