Flight model characterization of the wide-field off-axis telescope for the MATS satellite
Authors:
Woo** Park,
Arvid Hammar,
Soojong Pak,
Seunghyuk Chang,
Jörg Gumbel,
Linda Megner,
Ole Martin Christensen,
Jordan Rouse,
Dae Wook Kim
Abstract:
We present optical characterization, calibration, and performance tests of the Mesospheric Airglow/Aerosol Tomography Spectroscopy (MATS) satellite, which for the first time for a satellite applies a linear-astigmatism-free confocal off-axis reflective optical design. Mechanical tolerances of the telescope were investigated using Monte-Carlo methods and single-element perturbations. The sensitivit…
▽ More
We present optical characterization, calibration, and performance tests of the Mesospheric Airglow/Aerosol Tomography Spectroscopy (MATS) satellite, which for the first time for a satellite applies a linear-astigmatism-free confocal off-axis reflective optical design. Mechanical tolerances of the telescope were investigated using Monte-Carlo methods and single-element perturbations. The sensitivity analysis results indicate that tilt errors of the tertiary mirror and a surface RMS error of the secondary mirror mainly degrade optical performance. From the Monte-Carlo simulation, the tolerance limits were calculated to $\pm$0.5 mm, $\pm$1 mm, and $\pm$0.15$^\circ$ for decenter, despace, and tilt, respectively. We performed characterization measurements and optical tests with the flight model of the satellite. Multi-channel relative pointing, total optical system throughput, and distortion of each channel were characterized for end-users. Optical performance was evaluated by measuring modulation transfer function (MTF) and point spread function (PSF). The final MTF performance is 0.25 MTF at 20 lp/mm for the ultraviolet channel (304.5 nm), and 0.25 - 0.54 MTF at 10 lp/mm for infrared channels. The salient fact of the PSF measurement of this system is that there is no noticeable linear astigmatism detected over wide field of view (5.67$^\circ$ $\times$ 0.91$^\circ$). All things considered, the design method showed great advantages in wide field of view observations with satellite-level optical performance.
△ Less
Submitted 7 July, 2020;
originally announced July 2020.
Development of Linear Astigmatism Free -- Three Mirror System (LAF-TMS)
Authors:
Woo** Park,
Seunghyuk Chang,
Jae Hyuk Lim,
Sunwoo Lee,
Hojae Ahn,
Yunjong Kim,
Sanghyuk Kim,
Arvid Hammar,
Byeongjoon Jeong,
Geon Hee Kim,
Hyoungkwon Lee,
Dae Wook Kim,
Soojong Pak
Abstract:
We present the development of Linear Astigmatism Free - Three Mirror System (LAF-TMS). This is a prototype of an off-axis telescope that enables very wide field of view (FoV) infrared satellites that can observe Paschen-$α$ emission, zodiacal light, integrated star light, and other infrared sources. It has the entrance pupil diameter of 150 mm, the focal length of 500 mm, and the FoV of 5.5…
▽ More
We present the development of Linear Astigmatism Free - Three Mirror System (LAF-TMS). This is a prototype of an off-axis telescope that enables very wide field of view (FoV) infrared satellites that can observe Paschen-$α$ emission, zodiacal light, integrated star light, and other infrared sources. It has the entrance pupil diameter of 150 mm, the focal length of 500 mm, and the FoV of 5.5$^\circ$ $\times$ 4.1$^\circ$. LAF-TMS is an obscuration-free off-axis system with minimal out-of-field baffling and no optical support structure diffraction. This optical design is analytically optimized to remove linear astigmatism and to reduce high-order aberrations. Sensitivity analysis and Monte-Carlo simulation reveal that tilt errors are the most sensitive alignment parameters that allow $\sim$1$^\prime$. Optomechanical structure accurately mounts aluminum mirrors, and withstands satellite-level vibration environments. LAF-TMS shows optical performance with 37 $μ$m FWHM of the point source image satisfying Nyquist sampling requirements for typical 18 $μ$m pixel Infrared array detectors. The surface figure errors of mirrors and scattered light from the tertiary mirror with 4.9 nm surface micro roughness may affect the measured point spread function (PSF). Optical tests successfully demonstrate constant optical performance over wide FoV, indicating that LAF-TMS suppresses linear astigmatism and high-order aberrations.
△ Less
Submitted 13 February, 2020;
originally announced February 2020.