RAIDER: Rapid, anatomy-independent deep learning-based chemical shift-encoded MRI
Authors:
T. J. P. Bray,
G. V. Minore,
A. Bainbridge,
S. A. Taylor,
M. A. Hall-Craggs,
H. Zhang
Abstract:
Purpose: Despite recent advances, chemical shift-encoded MRI (CSE-MRI) remains a challenging problem and many algorithms are computationally expensive, leading to interest in deep learning-based methods. However, initial attempts have used convolutional neural networks (CNNs), which are limited by data requirements, poor generalisability across different anatomies (anatomy-dependence) and training…
▽ More
Purpose: Despite recent advances, chemical shift-encoded MRI (CSE-MRI) remains a challenging problem and many algorithms are computationally expensive, leading to interest in deep learning-based methods. However, initial attempts have used convolutional neural networks (CNNs), which are limited by data requirements, poor generalisability across different anatomies (anatomy-dependence) and training time. To address these limitations, we propose RAIDER, a method for rapid, anatomy-independent deep learning-based CSE-MRI.
Theory and Methods: RAIDER uses two multilayer perceptrons (MLPs), each trained separately with simulated single-voxel data, thus avoiding the degeneracy encountered during training when using only one network. During inference, the solution from one of the two networks is chosen based on likelihood. Performance and speed are investigated in a series of simulation experiments, in phantoms and in vivo.
Results: RAIDER is approximately 700 times faster than conventional fitting, taking 14us per voxel rather than 10ms, and offers performance similar to that of conventional fitting. It produces accurate fat fraction measurements in phantoms and in vivo images with different anatomies, despite having been trained only on simulation data.
Conclusion: RAIDER resolves the problems posed by degeneracy, avoids the training data requirements of CNN-based methods and markedly reduces computational cost compared to conventional fitting.
△ Less
Submitted 2 March, 2024;
originally announced March 2024.
-
MAGORINO: Magnitude-only fat fraction and R2* estimation with Rician noise modelling
Authors:
Timothy JP Bray,
Alan Bainbridge,
Margaret A Hall-Craggs,
Hui Zhang
Abstract:
Purpose: Magnitude-based fitting of chemical shift-encoded data enables proton density fat fraction (PDFF) and R2* estimation where complex-based methods fail or when phase data is inaccessible or unreliable, such as in multi-centre studies. However, traditional magnitude-based fitting algorithms suffer from Rician noise-related bias and fat-water swaps. To address these issues, we propose an algo…
▽ More
Purpose: Magnitude-based fitting of chemical shift-encoded data enables proton density fat fraction (PDFF) and R2* estimation where complex-based methods fail or when phase data is inaccessible or unreliable, such as in multi-centre studies. However, traditional magnitude-based fitting algorithms suffer from Rician noise-related bias and fat-water swaps. To address these issues, we propose an algorithm for Magnitude-Only PDFF and R2* estimation with Rician Noise modelling (MAGORINO).
Methods: Simulations of multi-echo gradient echo signal intensities are used to investigate the performance and behavior of MAGORINO over the space of clinically plausible PDFF, R2* and SNR values. Fitting performance is assessed in terms of parameter bias, precision and fitting error. To gain deeper insights into algorithm behavior, the paths on the likelihood functions are visualized and statistics describing correct optimization are generated. MAGORINO is compared against Gaussian noise-based magnitude fitting and complex fitting.
Results: Simulations show that MAGORINO reduces bias in both PDFF and R2* measurements compared to Gaussian fitting, through two main mechanisms: (i) a greater chance of selecting the true (non-swapped) optimum, and (ii) a shift in the position of the optima such that the estimates are closer to ground truth solutions, as a result of the correct noise model.
Conclusion: MAGORINO reduces fat-water swaps and Rician noise-related bias in PDFF and R2* estimation, thus addressing key limitations of traditional Gaussian noise-based magnitude-only fitting.
△ Less
Submitted 3 March, 2022; v1 submitted 11 October, 2021;
originally announced October 2021.
-
Volume of hyperintense inflammation (VHI): a deep learning-enabled quantitative imaging biomarker of inflammation load in spondyloarthritis
Authors:
Carolyna Hepburn,
Alexis Jones,
Alan Bainbridge,
Coziana Ciurtin,
Juan Eugenio Iglesias,
Hui Zhang,
Margaret A. Hall-Craggs,
Timothy JP Bray,
. Joint senior authorship.
Abstract:
Short inversion time inversion recovery (STIR) MRI is widely used in clinical practice to identify and quantify inflammation in axial spondyloarthritis. However, assessment of STIR images is limited by the need for qualitative evaluation, which depends on observer experience and expertise, creating substantial variability in inflammation assessments. To address this problem, we developed a deep le…
▽ More
Short inversion time inversion recovery (STIR) MRI is widely used in clinical practice to identify and quantify inflammation in axial spondyloarthritis. However, assessment of STIR images is limited by the need for qualitative evaluation, which depends on observer experience and expertise, creating substantial variability in inflammation assessments. To address this problem, we developed a deep learning-enabled, semiautomated workflow for segmentation of inflammatory lesions, whereby an initial segmentation is generated automatically and a radiologist then 'cleans' the segmentation by removing extraneous segmented voxels. The final cleaned segmentation defines the volume of hyperintense inflammation (VHI), which we propose as a quantitative imaging biomarker of inflammation load in spondyloarthritis. The data, code and models used in the study are available at https://github.com/c-hepburn/Bone_MRI.
△ Less
Submitted 14 August, 2022; v1 submitted 21 June, 2021;
originally announced June 2021.
-
Negative-contrast neurography: Imaging the extracranial facial nerve and its branches using contrast-enhanced variable flip angle turbo spin echo MRI
Authors:
Timothy JP Bray,
Emma A Lim,
Susan Jawad,
Sumandeep Kaur,
Sofia Otero,
Timothy J Beale,
Mark McGurk,
Alan Bainbridge,
Margaret A Hall-Craggs,
Simon J Morley
Abstract:
Background and Purpose: Various 'positive-contrast' neurographic methods have been investigated for imaging the extracranial course of the facial nerve. However, nerve visibility can be inconsistent with these sequences and may depend on the composition of the parotid gland, limiting consistent identification. To address this, we describe and evaluate a 'negative-contrast' method for imaging of th…
▽ More
Background and Purpose: Various 'positive-contrast' neurographic methods have been investigated for imaging the extracranial course of the facial nerve. However, nerve visibility can be inconsistent with these sequences and may depend on the composition of the parotid gland, limiting consistent identification. To address this, we describe and evaluate a 'negative-contrast' method for imaging of the extracranial facial nerve using three-dimensional variable flip angle turbo spin echo (VFA-TSE) imaging. We investigate strategies for further optimization, including parotid-specific VFA-TSE optimization and the use of gadolinium-based contrast agent (GBCA). Materials and Methods: 6 healthy volunteers and 10 patients with parotid tumors underwent VFA-TSE and double echo steady state (DESS) imaging of the extracranial facial nerve at 3T. The main trunk, divisions and branches of the extracranial facial nerve were manually segmented by three radiologists, enabling CNR and Hausdorff distance computation and confidence scoring. CNR, Hausdorff distance and confidence scores were compared between sequences and between pre- and post-contrast imaging to evaluate the effect of GBCA. Results: CNR, Hausdorff distances and confidence scores were superior for VFA-TSE compared to DESS imaging. GBCA administration produced a further increase in CNR of nerve against parotid and improved differentiation of nerve from tumor. Conclusion: Imaging of the extracranial facial nerve with VFA-TSE depicts the nerve as a low signal structure ('black nerve') against the high signal parotid parenchyma ('white parotid') and outperforms positive-contrast DESS imaging in terms of CNR, segmentation consistency and confidence. GBCA further increases negative contrast and improves differentiation of nerve from tumor.
△ Less
Submitted 31 March, 2021; v1 submitted 24 March, 2021;
originally announced March 2021.
-
Task-driven assessment of experimental designs in diffusion MRI: a computational framework
Authors:
Sean C. Epstein,
Timothy J. P. Bray,
Margaret A. Hall-Craggs,
Hui Zhang
Abstract:
This paper proposes a task-driven computational framework for assessing diffusion MRI experimental designs which, rather than relying on parameter-estimation metrics, directly measures quantitative task performance. Traditional computational experimental design (CED) methods may be ill-suited to experimental tasks, such as clinical classification, where outcome does not depend on parameter-estimat…
▽ More
This paper proposes a task-driven computational framework for assessing diffusion MRI experimental designs which, rather than relying on parameter-estimation metrics, directly measures quantitative task performance. Traditional computational experimental design (CED) methods may be ill-suited to experimental tasks, such as clinical classification, where outcome does not depend on parameter-estimation accuracy or precision alone. Current assessment metrics evaluate experiments' ability to faithfully recover microstructural parameters rather than their task performance. The method we propose addresses this shortcoming. For a given MRI experimental design, experiments are simulated start-to-finish and task performance is computed from ROC curves and associated summary metrics (e.g. AUC). Two experiments were performed: first, a validation of the pipeline's task performance predictions against clinical results, comparing in-silico predictions to real-world ROC/AUC; and second, a demonstration of the pipeline's advantages over traditional CED approaches, using two simulated clinical classification tasks. Comparison with clinical datasets validates our method's predictions of (a) the qualitative form of ROC curves, (b) the relative task performance of different experimental designs, and (c) the absolute performance of each experimental design. Furthermore, we show that our method outperforms traditional task-agnostic assessment methods, enabling improved, more useful experimental design. Compared to current approaches, such task-driven assessment is more likely to identify experimental designs that perform well in practice. Our method is not limited to diffusion MRI; the pipeline generalises to any task-based quantitative MRI application, and provides the foundation for develo** future task-driven end-to end CED frameworks.
△ Less
Submitted 16 September, 2021; v1 submitted 15 March, 2021;
originally announced March 2021.