-
A Cryogenic Torsion Balance Using a Liquid-Cryogen Free, Ultra-Low Vibration Cryostat
Authors:
S. M. Fleischer,
M. P. Ross,
K. Venkateswara,
C. A. Hagedorn,
E. A. Shaw,
E. Swanson,
B. R. Heckel,
J. H. Gundlach
Abstract:
We describe a liquid-cryogen free cryostat with ultra-low vibration levels which allows for continuous operation of a torsion balance at cryogenic temperatures. The apparatus uses a commercially available two-stage pulse-tube cooler and passive vibration isolation. The torsion balance exhibits torque noise levels lower than room temperature thermal noise by a factor of about four in the frequency…
▽ More
We describe a liquid-cryogen free cryostat with ultra-low vibration levels which allows for continuous operation of a torsion balance at cryogenic temperatures. The apparatus uses a commercially available two-stage pulse-tube cooler and passive vibration isolation. The torsion balance exhibits torque noise levels lower than room temperature thermal noise by a factor of about four in the frequency range of 3-10mHz, limited by residual seismic motion and by radiative heating of the pendulum body. In addition to lowering thermal noise below room-temperature limits, the low-temperature environment enables novel torsion balance experiments. Currently, the maximum duration of a continuous measurement run is limited by accumulation of cryogenic surface contamination on the optical elements inside the cryostat.
△ Less
Submitted 8 November, 2022; v1 submitted 6 June, 2022;
originally announced June 2022.
-
A torsion-balance search for ultra low-mass bosonic dark matter
Authors:
E. A. Shaw,
M. P. Ross,
C. A. Hagedorn,
E. G. Adelberger,
J. H. Gundlach
Abstract:
We used a stationary torsion balance with a beryllium-aluminum composition dipole to search for ultra low-mass bosonic dark matter coupled to baryon minus lepton number. We set 95% confidence limits on the coupling constant $g_{\rm B-L}$ for bosons with masses between $10^{-18}$ and $10^{-16}$ eV/$c^2$ with the best performance at $m_{\rm DM} = 8\times 10^{-18}$ eV/$c^2$ constraining…
▽ More
We used a stationary torsion balance with a beryllium-aluminum composition dipole to search for ultra low-mass bosonic dark matter coupled to baryon minus lepton number. We set 95% confidence limits on the coupling constant $g_{\rm B-L}$ for bosons with masses between $10^{-18}$ and $10^{-16}$ eV/$c^2$ with the best performance at $m_{\rm DM} = 8\times 10^{-18}$ eV/$c^2$ constraining $g_{B-L}(\hbar c)^{-1/2} < 1 \times 10^{-25}$. This provides a complimentary limit to equivalence-principle experiments that search for ultra low-mass bosons as force-mediating particles.
△ Less
Submitted 10 January, 2022; v1 submitted 17 September, 2021;
originally announced September 2021.
-
A Low-Frequency Torsion Pendulum with Interferometric Readout
Authors:
M. P. Ross,
K. Venkateswara,
C. A. Hagedorn,
C. J. Leupold,
P. W. F. Forsyth,
J. D. Wegner,
E. A. Shaw,
J. G. Lee,
J. H. Gundlach
Abstract:
We describe a torsion pendulum with a large mass-quadrupole moment and a resonant frequency of 2.8 mHz, whose angle is measured using a modified Michelson interferometer. The system achieved noise levels of $\sim200\ \text{prad}/\sqrt{\text{Hz}}$ between 0.2-30 Hz and $\sim10\ \text{prad}/\sqrt{\text{Hz}}$ above 100 Hz. Such a system can be applied to a broad range of fields from the study of rota…
▽ More
We describe a torsion pendulum with a large mass-quadrupole moment and a resonant frequency of 2.8 mHz, whose angle is measured using a modified Michelson interferometer. The system achieved noise levels of $\sim200\ \text{prad}/\sqrt{\text{Hz}}$ between 0.2-30 Hz and $\sim10\ \text{prad}/\sqrt{\text{Hz}}$ above 100 Hz. Such a system can be applied to a broad range of fields from the study of rotational seismic motion and elastogravity signals to gravitational wave observation and tests of gravity.
△ Less
Submitted 20 April, 2021; v1 submitted 4 January, 2021;
originally announced January 2021.
-
Limits on the Stochastic Gravitational Wave Background and Prospects for Single Source Detection with GRACE Follow-On
Authors:
M. P. Ross,
C. A. Hagedorn,
E. A. Shaw,
A. L. Lockwood,
B. M. Iritani,
J. G. Lee,
K. Venkateswara,
J. H. Gundlach
Abstract:
With a reinterpretation of recent results, the GRACE Follow-On mission can be applied to gravitational wave astronomy. Existing GRACE Follow-On data constrain the stochastic gravitational wave background to $Ω_{GW}<3.3\times10^{7}$ at 100 mHz. With a dedicated analysis, GRACE Follow-On may be able to detect the inspiral of local neutron star binaries, inspiral of subgalactic stellar-mass black hol…
▽ More
With a reinterpretation of recent results, the GRACE Follow-On mission can be applied to gravitational wave astronomy. Existing GRACE Follow-On data constrain the stochastic gravitational wave background to $Ω_{GW}<3.3\times10^{7}$ at 100 mHz. With a dedicated analysis, GRACE Follow-On may be able to detect the inspiral of local neutron star binaries, inspiral of subgalactic stellar-mass black hole binaries, or mergers of intermediate-mass black hole binaries within the Milky Way.
△ Less
Submitted 13 May, 2020; v1 submitted 5 February, 2020;
originally announced February 2020.
-
Inter-Party Avalanche Involvements May Increase Quadratically With Party Density
Authors:
Charles A. Hagedorn
Abstract:
We estimate, from first-principles, the rate of inter-party avalanche involvements. The model suggests that the likelihood of inter-party involvements is quadratic in the density of parties -- twice as many parties quadruples the likelihood. The model predicts that when the product of the party-density and the area of a day's potential avalanches approaches one, inter-party avalanche involvements…
▽ More
We estimate, from first-principles, the rate of inter-party avalanche involvements. The model suggests that the likelihood of inter-party involvements is quadratic in the density of parties -- twice as many parties quadruples the likelihood. The model predicts that when the product of the party-density and the area of a day's potential avalanches approaches one, inter-party avalanche involvements will become a substantial fraction of all avalanche involvements. As a corollary, the relative rate of inter-party involvements is expected to increase with avalanche size. We argue, with selected North American inter-party incidents from 2001-2019, that inter-party involvements are a timely concern. To spur conversation, we enumerate a variety of strategies that may mitigate inter-party hazard.
△ Less
Submitted 23 October, 2019;
originally announced October 2019.
-
Constraints on axionlike dark matter with masses down to $10^{-23}$ eV/c$^2$
Authors:
William A. Terrano,
Eric G. Adelberger,
Charles A. Hagedorn,
Blayne R. Heckel
Abstract:
We analyzed an 6.7-year span of data from a rotating torsion-pendulum containing $\approx 10^{23}$ polarized electrons to search for the "wind" arising from ultralight, axionlike dark matter with masses between $10^{-23}$ and $10^{-18}$ eV/c$^2$. Over most of this range we obtain a 95\% confidence limit $F_{\rm a}/C_{\rm e} \geq 1 \times 10^{15}$ eV on the axionlike decay constant.
We analyzed an 6.7-year span of data from a rotating torsion-pendulum containing $\approx 10^{23}$ polarized electrons to search for the "wind" arising from ultralight, axionlike dark matter with masses between $10^{-23}$ and $10^{-18}$ eV/c$^2$. Over most of this range we obtain a 95\% confidence limit $F_{\rm a}/C_{\rm e} \geq 1 \times 10^{15}$ eV on the axionlike decay constant.
△ Less
Submitted 28 May, 2019; v1 submitted 12 February, 2019;
originally announced February 2019.
-
Low Frequency Tilt Seismology with a Precision Ground Rotation Sensor
Authors:
M. P. Ross,
K. Venkateswara,
C. A. Hagedorn,
J. H. Gundlach,
J. S. Kissel,
J. Warner,
H. Radkins,
T. J. Shaffer,
M. W. Coughlin,
P. Bodin
Abstract:
We describe measurements of the rotational component of teleseismic surface waves using an inertial high-precision ground-rotation-sensor installed at the LIGO Hanford Observatory (LHO). The sensor has a noise floor of 0.4 nrad$/ \sqrt{\rm Hz}$ at 50 mHz and a translational coupling of less than 1 $μ$rad/m enabling translation-free measurement of small rotations. We present observations of the rot…
▽ More
We describe measurements of the rotational component of teleseismic surface waves using an inertial high-precision ground-rotation-sensor installed at the LIGO Hanford Observatory (LHO). The sensor has a noise floor of 0.4 nrad$/ \sqrt{\rm Hz}$ at 50 mHz and a translational coupling of less than 1 $μ$rad/m enabling translation-free measurement of small rotations. We present observations of the rotational motion from Rayleigh waves of six teleseismic events from varied locations and with magnitudes ranging from M6.7 to M7.9. These events were used to estimate phase dispersion curves which shows agreement with a similar analysis done with an array of three STS-2 seismometers also located at LHO.
△ Less
Submitted 25 July, 2017; v1 submitted 10 July, 2017;
originally announced July 2017.
-
A high-precision mechanical absolute-rotation sensor
Authors:
Krishna Venkateswara,
Charles A. Hagedorn,
Matthew D. Turner,
Trevor Arp,
Jens H. Gundlach
Abstract:
We have developed a mechanical absolute-rotation sensor capable of resolving ground rotation angle of less than 1 nrad$/\sqrt{\text{Hz}}$ above $30$ mHz and 0.2 nrad$/\sqrt{\text{Hz}}$ above $100$ mHz about a single horizontal axis. The device consists of a meter-scale beam balance, suspended by a pair of flexures, with a resonance frequency of 10.8 mHz. The center of mass is located 3 $μ$m above…
▽ More
We have developed a mechanical absolute-rotation sensor capable of resolving ground rotation angle of less than 1 nrad$/\sqrt{\text{Hz}}$ above $30$ mHz and 0.2 nrad$/\sqrt{\text{Hz}}$ above $100$ mHz about a single horizontal axis. The device consists of a meter-scale beam balance, suspended by a pair of flexures, with a resonance frequency of 10.8 mHz. The center of mass is located 3 $μ$m above the pivot, giving an excellent horizontal displacement rejection of better than $3\times10^{-5}$ rad/m. The angle of the beam is read out optically using a high-sensitivity autocollimator. We have also built a tiltmeter with better than 1 nrad$/\sqrt{\text{Hz}}$ sensitivity above 30 mHz. Co-located measurements using the two instruments allowed us to distinguish between background rotation signal at low frequencies and intrinsic instrument noise. The rotation sensor is useful for rotational seismology and for rejecting background rotation signal from seismometers in experiments demanding high levels of seismic isolation, such as Advanced LIGO.
△ Less
Submitted 16 January, 2014;
originally announced January 2014.
-
A reference-beam autocollimator with nanoradian sensitivity from mHz to kHz and dynamic range of 10^7
Authors:
T. B. Arp,
C. A. Hagedorn,
S. Schlamminger,
J. H. Gundlach
Abstract:
We describe an autocollimating optical angle sensor with a dynamic range of 9 mrad and nrad/sqrt(Hz) sensitivity at frequencies from 5 mHz to 3 kHz. This work improves the standard multi-slit autocollimator design by adding two optical components, a reference mirror and a condensing lens. This autocollimator makes a differential measurement between a reference mirror and a target mirror, suppressi…
▽ More
We describe an autocollimating optical angle sensor with a dynamic range of 9 mrad and nrad/sqrt(Hz) sensitivity at frequencies from 5 mHz to 3 kHz. This work improves the standard multi-slit autocollimator design by adding two optical components, a reference mirror and a condensing lens. This autocollimator makes a differential measurement between a reference mirror and a target mirror, suppressing common-mode noise sources. The condensing lens reduces optical aberrations, increases intensity, and improves image quality. To further improve the stability of the device at low frequencies the body of the autocollimator is designed to reduce temperature variations and their effects. A new data processing technique was developed in order to suppress the effects of imperfections in the CCD.
△ Less
Submitted 18 September, 2013;
originally announced September 2013.
-
Brownian force noise from molecular collisions and the sensitivity of advanced gravitational wave observatories
Authors:
R. Dolesi,
M. Hueller,
D. Nicolodi,
D. Tombolato,
S. Vitale,
P. J. Wass,
W. J. Weber,
M. Evans,
P. Fritschel,
R. Weiss,
J. H. Gundlach,
C. A. Hagedorn,
S. Schlamminger,
G. Ciani,
A. Cavalleri
Abstract:
We present an analysis of Brownian force noise from residual gas dam** of reference test masses as a fundamental sensitivity limit in small force experiments. The resulting acceleration noise increases significantly when the distance of the test mass to the surrounding experimental apparatus is smaller than the dimension of the test mass itself. For the Advanced LIGO interferometric gravitationa…
▽ More
We present an analysis of Brownian force noise from residual gas dam** of reference test masses as a fundamental sensitivity limit in small force experiments. The resulting acceleration noise increases significantly when the distance of the test mass to the surrounding experimental apparatus is smaller than the dimension of the test mass itself. For the Advanced LIGO interferometric gravitational wave observatory, where the relevant test mass is a suspended 340 mm diameter cylindrical end mirror, the force noise power is increased by roughly a factor 40 by the presence of a similarly shaped reaction mass at a nominal separation of 5 mm. The force noise, of order 20 fN\rthz\ for $2 \times 10^{-6}$ Pa of residual H$_2$ gas, rivals quantum optical fluctuations as the dominant noise source between 10 and 30 Hz. We present here a numerical and analytical analysis for the gas dam** force noise for Advanced LIGO, backed up by experimental evidence from several recent measurements. Finally, we discuss the impact of residual gas dam** on the gravitational wave sensitivity and possible mitigation strategies.
△ Less
Submitted 30 September, 2011; v1 submitted 16 August, 2011;
originally announced August 2011.
-
Picoradian deflection measurement with an interferometric quasi-autocollimator using weak value amplification
Authors:
Matthew D. Turner,
Charles A. Hagedorn,
Stephan Schlamminger,
Jens H. Gundlach
Abstract:
We present an "interferometric quasi-autocollimator" that employs weak value amplification to measure angular deflections of a target mirror. The device has been designed to be insensitive to all translations of the target. We present a conceptual explanation of the amplification effect used by the device. An implementation of the device demonstrates sensitivities better than 10 picoradians per ro…
▽ More
We present an "interferometric quasi-autocollimator" that employs weak value amplification to measure angular deflections of a target mirror. The device has been designed to be insensitive to all translations of the target. We present a conceptual explanation of the amplification effect used by the device. An implementation of the device demonstrates sensitivities better than 10 picoradians per root hertz between 10 and 200 hertz.
△ Less
Submitted 22 March, 2011;
originally announced March 2011.
-
Indirect Evidence for Lévy Walks in Squeeze Film Dam**
Authors:
Stephan Schlamminger,
Charles A. Hagedorn,
Jens H. Gundlach
Abstract:
Molecular flow gas dam** of mechanical motion in confined geometries, and its associated noise, is important in a variety of fields, including precision measurement, gravitational wave detection, and MEMS devices. We used two torsion balance instruments to measure the strength and distance-dependence of `squeeze film' dam**. Measured quality factors derived from free decay of oscillation are c…
▽ More
Molecular flow gas dam** of mechanical motion in confined geometries, and its associated noise, is important in a variety of fields, including precision measurement, gravitational wave detection, and MEMS devices. We used two torsion balance instruments to measure the strength and distance-dependence of `squeeze film' dam**. Measured quality factors derived from free decay of oscillation are consistent with gas particle superdiffusion in Lévy walks and inconsistent with those expected from traditional Gaussian random walk particle motion. The distance-dependence of squeeze film dam** observed in our experiments is in agreement with a parameter-free Monte Carlo simulation. The squeeze film dam** of the motion of a plate suspended a distance d away from a parallel surface scales with a fractional power between 1/d and 1/d^2.
△ Less
Submitted 29 May, 2010; v1 submitted 26 May, 2010;
originally announced May 2010.
-
Charge Management for Gravitational Wave Observatories using UV LEDs
Authors:
S. E. Pollack,
M. D. Turner,
S. Schlamminger,
C. A. Hagedorn,
J. H. Gundlach
Abstract:
Accumulation of electrical charge on the end mirrors of gravitational wave observatories, such as the space-based LISA mission and ground-based LIGO detectors, can become a source of noise limiting the sensitivity of such detectors through electronic couplings to nearby surfaces. Torsion balances provide an ideal means for testing gravitational wave technologies due to their high sensitivity to…
▽ More
Accumulation of electrical charge on the end mirrors of gravitational wave observatories, such as the space-based LISA mission and ground-based LIGO detectors, can become a source of noise limiting the sensitivity of such detectors through electronic couplings to nearby surfaces. Torsion balances provide an ideal means for testing gravitational wave technologies due to their high sensitivity to small forces. Our torsion pendulum apparatus consists of a movable Au-coated Cu plate brought near a Au-coated Si plate pendulum suspended from a non-conducting quartz fiber. A UV LED located near the pendulum photoejects electrons from the surface, and a UV LED driven electron gun directs photoelectrons towards the pendulum surface. We have demonstrated both charging and discharging of the pendulum with equivalent charging rates of $\sim$$10^5 e/\mathrm{s}$, as well as spectral measurements of the pendulum charge resulting in a white noise level equivalent to $3\times10^5 e/\sqrt{Hz}$.
△ Less
Submitted 9 December, 2009;
originally announced December 2009.
-
High Sensitivity Torsion Balance Tests for LISA Proof Mass Modeling
Authors:
S. Schlamminger,
C. A. Hagedorn,
M. G. Famulare,
S. E. Pollack,
J. H. Gundlach
Abstract:
We have built a highly sensitive torsion balance to investigate small forces between closely spaced gold coated surfaces. Such forces will occur between the LISA proof mass and its housing. These forces are not well understood and experimental investigations are imperative. We describe our torsion balance and present the noise of the system. A significant contribution to the LISA noise budget at…
▽ More
We have built a highly sensitive torsion balance to investigate small forces between closely spaced gold coated surfaces. Such forces will occur between the LISA proof mass and its housing. These forces are not well understood and experimental investigations are imperative. We describe our torsion balance and present the noise of the system. A significant contribution to the LISA noise budget at low frequencies is the fluctuation in the surface potential difference between the proof mass and its housing. We present first results of these measurements with our apparatus.
△ Less
Submitted 8 February, 2007;
originally announced February 2007.