Investigation of the aptness of newly developed epoxy-based equivalent tissues for newborn and 5-years old in paediatric radiology
Authors:
Nabeel Ibrahim Ashour,
Muhammad Fahmi Rizal Abdul Hadi,
Nurul Ab. Aziz Hashikin,
Mohammed Ali Dheyab,
Ahmed Sadeq Musa,
Nik Noor Ashikin Nik Ab Razak,
Mohd Zahri Abdul Aziz
Abstract:
The varied radiological applications of tissue equivalent (TE) materials encompass quality checks, diagnostic imaging and dose evaluations. Nevertheless, the availability of compounds representative of paediatric patient tissues for scientific use in lower diagnostic photon energy spectra is limited. In this study, several TE substitutes were developed which replicate the radiographic characterist…
▽ More
The varied radiological applications of tissue equivalent (TE) materials encompass quality checks, diagnostic imaging and dose evaluations. Nevertheless, the availability of compounds representative of paediatric patient tissues for scientific use in lower diagnostic photon energy spectra is limited. In this study, several TE substitutes were developed which replicate the radiographic characteristics of human tissue within these energy ranges, i.e. TE materials for neonatal soft tissue (ESST-NB), neonatal skeletal tissue (ESTB-NB), and the equivalent tissue types representative of a 5 year old child (ESST and ESBT, respectively). The ORNL stylised computational model series was used as a source for the desired elemental proportions. The density, effective atomic number, CT numbers and electron densities calculated for the developed tissue substitutes approximated those of the phantom system used as a reference. Additionally, in kee** with the material choice and production limitations, as close correlations as possible were achieved for all the materials in relation to the reference data for mass densities, mass attenuation coefficients and mass energy-absorption coefficients. The TE substitutes for the newborn over an energy range of 47 keV to 66 keV exhibited maximum discrepancies for μ/\r{ho} of 1.6% to -3.01%, and for μ_en/\r{ho} of 1.15% to -1.4% in relation to the ORNL reference samples. The respective equivalent data ranges were 1.09 % to -3.02% and 1.92% to -2.53% for the TE materials representative of a 5-year-old. Given the excellent concordance achieved between the newly constructed TE materials and the reference data, these compounds can subsequently be utilised to create physical phantoms representative of tissue types in neonates and children aged 5 years.
△ Less
Submitted 25 December, 2022;
originally announced December 2022.
-
HARMONI at ELT: designing a laser guide star wavefront sensors for the ELT
Authors:
Anne Costille,
Anne Bonnefoi,
Edgard Renault,
William Ceria,
Kjetil Dohlen,
Benoit Neichel,
Zoltan Hubert,
Jean-Jacques Correia,
Thibaut Moulin,
Saul Menendez Mendoza,
Thierry Fusco,
Pascal Vola,
Felipe Pedreros,
Pierre Jouve,
El Kacem,
Fraser Hadi,
Hermine Schnetler,
Dave Melotte,
Niranjan Thatte
Abstract:
HARMONI is the first light visible and near-IR integral field spectrograph for the ELT covering a large spectral range from 450nm to 2450nm with resolving powers from 3500 to 18000 and spatial sampling from 60mas to 4mas. It can operate in two Adaptive Optics modes-SCAO and LTAO-or with no AO. The project is preparing for Final Design Reviews. The laser Tomographic AO (LTAO) system provides AO cor…
▽ More
HARMONI is the first light visible and near-IR integral field spectrograph for the ELT covering a large spectral range from 450nm to 2450nm with resolving powers from 3500 to 18000 and spatial sampling from 60mas to 4mas. It can operate in two Adaptive Optics modes-SCAO and LTAO-or with no AO. The project is preparing for Final Design Reviews. The laser Tomographic AO (LTAO) system provides AO correction with very high sky-coverage thanks to two systems: the Laser Guide Star Sensors (LGSS) and the Natural Guide Star Sensors (NGSS). LGSS is dedicated to the analysis of the wavefront coming from 6 laser guide stars created by the ELT. It is made of 6 independent wavefront sensor (WFS) modules mounted on a rotator of 600mm diameter to stabilise the pupil onto the microlens array in front of the detector. The optical design accepts elongated spots of up to 16 arcsec with no truncation using a CMOS detector from SONY. We will present the final optical and mechanical design of the LGSS based on freeform lenses to minimize the numbers of optical components and to accommodate for the diversity of sodium layer configurations. We will focus on rotator design, illustrating how we will move 1 tons with 90" accuracy in restrictive environment. Finally, we will present the strategy to verify the system in HARMONI context. The main challenge for the verification being how to test an AO system without access to the deformable mirror, part of the ELT.
△ Less
Submitted 18 July, 2022;
originally announced July 2022.
-
A liquid xenon TPC for a medical imaging Compton telescope
Authors:
T. Oger,
W-T. Chen,
J-P. Cussonneau,
J. Donnard,
S. Duval,
J. Lamblin,
O. Lemaire,
A. F. Mohamad Hadi,
P. Le Ray,
E. Morteau,
L. Scotto Lavina,
J-S. Stutzmann,
D. Thers
Abstract:
A new technique for medical imaging, "3γ imaging", is studied by our group at SUBATECH for few years. A small liquid xenon time projection chamber prototype has been built in order to demonstrate the feasibility of this technique. With an ultra-low-noise front-end electronics, the energy deposit and resolution of 511 keV γ-ray as a function of drift electric field (E) is measured with high precisi…
▽ More
A new technique for medical imaging, "3γ imaging", is studied by our group at SUBATECH for few years. A small liquid xenon time projection chamber prototype has been built in order to demonstrate the feasibility of this technique. With an ultra-low-noise front-end electronics, the energy deposit and resolution of 511 keV γ-ray as a function of drift electric field (E) is measured with high precision. 500 μm of z resolution is estimated by measuring the charge carriers drift velocity and time resolution.
△ Less
Submitted 5 December, 2011; v1 submitted 16 September, 2011;
originally announced September 2011.
-
Fluorescence spectrum analysis using Fourier series modeling for Fluorescein solution in Ethanol
Authors:
Mahasin F. Hadi
Abstract:
We have measured the fluorescence spectrum for fluorescein solution in ethanol with concentration 1 {\times} 10-3 mol/liter at different temperatures from room temperature to freezing point of solvent, (T = 153, 183, 223, 253, and 303 K) using liquid nitrogen. Table curve 2D version 5.01 program has been used to determine the fitting curve and fitting equation for each fluorescence spectrum. Fouri…
▽ More
We have measured the fluorescence spectrum for fluorescein solution in ethanol with concentration 1 {\times} 10-3 mol/liter at different temperatures from room temperature to freezing point of solvent, (T = 153, 183, 223, 253, and 303 K) using liquid nitrogen. Table curve 2D version 5.01 program has been used to determine the fitting curve and fitting equation for each fluorescence spectrum. Fourier series (3 {\times} 2) was the most suitable fitting equation for all spectra. Theoretical fluorescence spectrum of fluorescein in ethanol at T = 183K was calculated and compared with experimental fluorescence spectrum at the same temperature. There is a good similarity between them.
△ Less
Submitted 22 August, 2011;
originally announced September 2011.