Skip to main content

Showing 1–5 of 5 results for author: Haan, A M J d

.
  1. arXiv:1609.05685  [pdf, other

    cond-mat.mes-hall physics.ins-det

    A method for mechanical generation of radio frequency fields in nuclear magnetic resonance force microscopy

    Authors: J. J. T. Wagenaar, A. M. J. den Haan, R. J. Donkersloot, F. Marsman, M. de Wit, L. Bossoni, T. H. Oosterkamp

    Abstract: We present an innovative method for magnetic resonance force microscopy (MRFM) with ultra-low dissipation, by using the higher modes of the mechanical detector as radio frequency (rf) source. This method allows MRFM on samples without the need to be close to an rf source. Furthermore, since rf sources require currents that give dissipation, our method enables nuclear magnetic resonance experiments… ▽ More

    Submitted 19 September, 2016; originally announced September 2016.

    Comments: 7 pages, 5 figures, to be submitted to Physical Review Applied

    Journal ref: Phys. Rev. Applied 7, 024019 (2017)

  2. arXiv:1603.04238  [pdf, other

    cond-mat.mes-hall physics.ins-det

    Probing the Nuclear Spin-Lattice Relaxation Time at the Nanoscale

    Authors: J. J. T. Wagenaar, A. M. J. den Haan, J. M. de Voogd, L. Bossoni, T. A. de Jong, M. de Wit, K. M. Bastiaans, D. J. Thoen, A. Endo, T. M. Klapwijk, J. Zaanen, T. H. Oosterkamp

    Abstract: Nuclear spin-lattice relaxation times are measured on copper using magnetic resonance force microscopy performed at temperatures down to 42 mK. The low temperature is verified by comparison with the Korringa relation. Measuring spin-lattice relaxation times locally at very low temperatures opens up the possibility to measure the magnetic properties of inhomogeneous electron systems realized in oxi… ▽ More

    Submitted 27 June, 2016; v1 submitted 14 March, 2016; originally announced March 2016.

    Comments: We revised the manuscript by including the supplemental material. The manuscript is changed from a Letter to a Research Article after change of journal

  3. Spin-mediated dissipation and frequency shifts of a cantilever at milliKelvin temperatures

    Authors: A. M. J. den Haan, J. J. T. Wagenaar, J. M. de Voogd, G. Koning, T. H. Oosterkamp

    Abstract: We measure the dissipation and frequency shift of a magnetically coupled cantilever in the vicinity of a silicon chip, down to $25$ mK. The dissipation and frequency shift originates from the interaction with the unpaired electrons, associated with the dangling bonds in the native oxide layer of the silicon, which form a two dimensional system of electron spins. We approach the sample with a… ▽ More

    Submitted 21 January, 2016; v1 submitted 3 September, 2015; originally announced September 2015.

    Comments: 5 pages, 3 figures

    Journal ref: Phys. Rev. B 92, 235441 (2015)

  4. arXiv:1504.07104  [pdf, ps, other

    cond-mat.mes-hall cond-mat.mtrl-sci

    Probing the magnetic moment of FePt micromagnets prepared by Focused Ion Beam milling

    Authors: H. C. Overweg, A. M. J. den Haan, H. J. Eerkens, P. F. A. Alkemade, A. L. La Rooij, R. J. C. Spreeuw, L. Bossoni, T. H. Oosterkamp

    Abstract: We investigate the degradation of the magnetic moment of a 300 nm thick FePt film induced by Focused Ion Beam (FIB) milling. A $1~μ\mathrm{m} \times 8~μ\mathrm{m}$ rod is milled out of a film by a FIB process and is attached to a cantilever by electron beam induced deposition. Its magnetic moment is determined by frequency-shift cantilever magnetometry. We find that the magnetic moment of the rod… ▽ More

    Submitted 23 August, 2015; v1 submitted 27 April, 2015; originally announced April 2015.

    Comments: 4 pages, 4 figures

    Journal ref: Appl. Phys. Lett. 107, 072402 (2015)

  5. arXiv:1312.6011  [pdf, ps, other

    physics.ins-det

    Atomic resolution STM in a cryogen free dilution refrigerator at 15 mK

    Authors: A. M. J. den Haan, G. H. C. J. Wijts, F. Galli, O. Usenko, G. J. C. van Baarle, D. J. van der Zalm, T. H. Oosterkamp

    Abstract: Pulse tube refrigerators are becoming more common, because they are cost efficient and demand less handling than conventional (wet) refrigerators. However, a downside of a pulse tube system is the vibration level at the cold-head, which is in most designs several micrometers. We implemented vibration isolation techniques which significantly reduced vibration levels at the experiment. These optimiz… ▽ More

    Submitted 2 February, 2014; v1 submitted 20 December, 2013; originally announced December 2013.

    Comments: 6 pages, 10 figures and 1 video 1st revision: added label a and b to figures 2 and 3 typo at page 5 at the end of section 4 (Results): replaced 10^-10 m/sqrt(Hz) to 10^-12 m/sqrt(Hz) (contact [email protected] for the calculation)

    Journal ref: Rev. Sci. Instrum. 85, 035112 (2014)