A method for mechanical generation of radio frequency fields in nuclear magnetic resonance force microscopy
Abstract: We present an innovative method for magnetic resonance force microscopy (MRFM) with ultra-low dissipation, by using the higher modes of the mechanical detector as radio frequency (rf) source. This method allows MRFM on samples without the need to be close to an rf source. Furthermore, since rf sources require currents that give dissipation, our method enables nuclear magnetic resonance experiments… ▽ More
Submitted 19 September, 2016; originally announced September 2016.
Comments: 7 pages, 5 figures, to be submitted to Physical Review Applied
Journal ref: Phys. Rev. Applied 7, 024019 (2017)
-
Probing the Nuclear Spin-Lattice Relaxation Time at the Nanoscale
Abstract: Nuclear spin-lattice relaxation times are measured on copper using magnetic resonance force microscopy performed at temperatures down to 42 mK. The low temperature is verified by comparison with the Korringa relation. Measuring spin-lattice relaxation times locally at very low temperatures opens up the possibility to measure the magnetic properties of inhomogeneous electron systems realized in oxi… ▽ More
Submitted 27 June, 2016; v1 submitted 14 March, 2016; originally announced March 2016.
Comments: We revised the manuscript by including the supplemental material. The manuscript is changed from a Letter to a Research Article after change of journal
-
Spin-mediated dissipation and frequency shifts of a cantilever at milliKelvin temperatures
Abstract: We measure the dissipation and frequency shift of a magnetically coupled cantilever in the vicinity of a silicon chip, down to $25$ mK. The dissipation and frequency shift originates from the interaction with the unpaired electrons, associated with the dangling bonds in the native oxide layer of the silicon, which form a two dimensional system of electron spins. We approach the sample with a… ▽ More
Submitted 21 January, 2016; v1 submitted 3 September, 2015; originally announced September 2015.
Comments: 5 pages, 3 figures
Journal ref: Phys. Rev. B 92, 235441 (2015)
-
arXiv:1504.07104 [pdf, ps, other]
Probing the magnetic moment of FePt micromagnets prepared by Focused Ion Beam milling
Abstract: We investigate the degradation of the magnetic moment of a 300 nm thick FePt film induced by Focused Ion Beam (FIB) milling. A $1~μ\mathrm{m} \times 8~μ\mathrm{m}$ rod is milled out of a film by a FIB process and is attached to a cantilever by electron beam induced deposition. Its magnetic moment is determined by frequency-shift cantilever magnetometry. We find that the magnetic moment of the rod… ▽ More
Submitted 23 August, 2015; v1 submitted 27 April, 2015; originally announced April 2015.
Comments: 4 pages, 4 figures
Journal ref: Appl. Phys. Lett. 107, 072402 (2015)
-
arXiv:1312.6011 [pdf, ps, other]
Atomic resolution STM in a cryogen free dilution refrigerator at 15 mK
Abstract: Pulse tube refrigerators are becoming more common, because they are cost efficient and demand less handling than conventional (wet) refrigerators. However, a downside of a pulse tube system is the vibration level at the cold-head, which is in most designs several micrometers. We implemented vibration isolation techniques which significantly reduced vibration levels at the experiment. These optimiz… ▽ More
Submitted 2 February, 2014; v1 submitted 20 December, 2013; originally announced December 2013.
Comments: 6 pages, 10 figures and 1 video 1st revision: added label a and b to figures 2 and 3 typo at page 5 at the end of section 4 (Results): replaced 10^-10 m/sqrt(Hz) to 10^-12 m/sqrt(Hz) (contact [email protected] for the calculation)
Journal ref: Rev. Sci. Instrum. 85, 035112 (2014)