-
Q-Net: A Quantitative Susceptibility Map**-based Deep Neural Network for Differential Diagnosis of Brain Iron Deposition in Hemochromatosis
Authors:
Soheil Zabihi,
Elahe Rahimian,
Soumya Sharma,
Sean K. Sethi,
Sara Gharabaghi,
Amir Asif,
E. Mark Haacke,
Mandar S. Jog,
Arash Mohammadi
Abstract:
Brain iron deposition, in particular deep gray matter nuclei, increases with advancing age. Hereditary Hemochromatosis (HH) is the most common inherited disorder of systemic iron excess in Europeans and recent studies claimed high brain iron accumulation in patient with Hemochromatosis. In this study, we focus on Artificial Intelligence (AI)-based differential diagnosis of brain iron deposition in…
▽ More
Brain iron deposition, in particular deep gray matter nuclei, increases with advancing age. Hereditary Hemochromatosis (HH) is the most common inherited disorder of systemic iron excess in Europeans and recent studies claimed high brain iron accumulation in patient with Hemochromatosis. In this study, we focus on Artificial Intelligence (AI)-based differential diagnosis of brain iron deposition in HH via Quantitative Susceptibility Map** (QSM), which is an established Magnetic Resonance Imaging (MRI) technique to study the distribution of iron in the brain. Our main objective is investigating potentials of AI-driven frameworks to accurately and efficiently differentiate individuals with Hemochromatosis from those of the healthy control group. More specifically, we developed the Q-Net framework, which is a data-driven model that processes information on iron deposition in the brain obtained from multi-echo gradient echo imaging data and anatomical information on T1-Weighted images of the brain. We illustrate that the Q-Net framework can assist in differentiating between someone with HH and Healthy control (HC) of the same age, something that is not possible by just visualizing images. The study is performed based on a unique dataset that was collected from 52 subjects with HH and 47 HC. The Q-Net provides a differential diagnosis accuracy of 83.16% and 80.37% in the scan-level and image-level classification, respectively.
△ Less
Submitted 1 October, 2021;
originally announced October 2021.
-
Mass production and characterization of 3-inch PMTs for the JUNO experiment
Authors:
Chuanya Cao,
Jilei Xu,
Miao He,
Angel Abusleme,
Mathieu Bongrand,
Clément Bordereau,
Dominique Breton,
Anatael Cabrera,
Agustin Campeny,
Cédric Cerna,
Haoqiang Chen,
Po-An Chen,
Gérard Claverie,
Selma Conforti Di Lorenzo,
Christophe De La Taille,
Frédéric Druillole,
Amélie Fournier,
Marco Grassi,
Xiaofei Gu,
Michael Haacke,
Yang Han,
Patrick Hellmuth,
Yuekun Heng,
Rafael Herrera,
Yee Hsiung
, et al. (42 additional authors not shown)
Abstract:
26,000 3-inch photomultiplier tubes (PMTs) have been produced for Jiangmen Underground Neutrino Observatory (JUNO) by the Hainan Zhanchuang Photonics Technology Co., Ltd (HZC) company in China and passed all acceptance tests with only 15 tubes rejected. The mass production began in 2018 and elapsed for about 2 years at a rate of $\sim$1,000~PMTs per month. The characterization of the PMTs was perf…
▽ More
26,000 3-inch photomultiplier tubes (PMTs) have been produced for Jiangmen Underground Neutrino Observatory (JUNO) by the Hainan Zhanchuang Photonics Technology Co., Ltd (HZC) company in China and passed all acceptance tests with only 15 tubes rejected. The mass production began in 2018 and elapsed for about 2 years at a rate of $\sim$1,000~PMTs per month. The characterization of the PMTs was performed in the factory concurrently with production as a joint effort between HZC and JUNO. Fifteen performance parameters were tracked at different sampling rates, and novel working strategies were implemented to improve quality assurance. This constitutes the largest sample of 3-inch PMTs ever produced and studied in detail to date.
△ Less
Submitted 26 February, 2021; v1 submitted 23 February, 2021;
originally announced February 2021.
-
VC-Net: Deep Volume-Composition Networks for Segmentation and Visualization of Highly Sparse and Noisy Image Data
Authors:
Yifan Wang,
Guoli Yan,
Haikuan Zhu,
Sagar Buch,
Ying Wang,
Ewart Mark Haacke,
**g Hua,
Zichun Zhong
Abstract:
The motivation of our work is to present a new visualization-guided computing paradigm to combine direct 3D volume processing and volume rendered clues for effective 3D exploration such as extracting and visualizing microstructures in-vivo. However, it is still challenging to extract and visualize high fidelity 3D vessel structure due to its high sparseness, noisiness, and complex topology variati…
▽ More
The motivation of our work is to present a new visualization-guided computing paradigm to combine direct 3D volume processing and volume rendered clues for effective 3D exploration such as extracting and visualizing microstructures in-vivo. However, it is still challenging to extract and visualize high fidelity 3D vessel structure due to its high sparseness, noisiness, and complex topology variations. In this paper, we present an end-to-end deep learning method, VC-Net, for robust extraction of 3D microvasculature through embedding the image composition, generated by maximum intensity projection (MIP), into 3D volume image learning to enhance the performance. The core novelty is to automatically leverage the volume visualization technique (MIP) to enhance the 3D data exploration at deep learning level. The MIP embedding features can enhance the local vessel signal and are adaptive to the geometric variability and scalability of vessels, which is crucial in microvascular tracking. A multi-stream convolutional neural network is proposed to learn the 3D volume and 2D MIP features respectively and then explore their inter-dependencies in a joint volume-composition embedding space by unprojecting the MIP features into 3D volume embedding space. The proposed framework can better capture small / micro vessels and improve vessel connectivity. To our knowledge, this is the first deep learning framework to construct a joint convolutional embedding space, where the computed vessel probabilities from volume rendering based 2D projection and 3D volume can be explored and integrated synergistically. Experimental results are compared with the traditional 3D vessel segmentation methods and the deep learning state-of-the-art on public and real patient (micro-)cerebrovascular image datasets. Our method demonstrates the potential in a powerful MR arteriogram and venogram diagnosis of vascular diseases.
△ Less
Submitted 14 September, 2020;
originally announced September 2020.
-
Automated Segmentation of Brain Gray Matter Nuclei on Quantitative Susceptibility Map** Using Deep Convolutional Neural Network
Authors:
Chao Chai,
Pengchong Qiao,
Bin Zhao,
Huiying Wang,
Guohua Liu,
Hong Wu,
E Mark Haacke,
Wen Shen,
Chen Cao,
Xinchen Ye,
Zhiyang Liu,
Shuang Xia
Abstract:
Abnormal iron accumulation in the brain subcortical nuclei has been reported to be correlated to various neurodegenerative diseases, which can be measured through the magnetic susceptibility from the quantitative susceptibility map** (QSM). To quantitively measure the magnetic susceptibility, the nuclei should be accurately segmented, which is a tedious task for clinicians. In this paper, we pro…
▽ More
Abnormal iron accumulation in the brain subcortical nuclei has been reported to be correlated to various neurodegenerative diseases, which can be measured through the magnetic susceptibility from the quantitative susceptibility map** (QSM). To quantitively measure the magnetic susceptibility, the nuclei should be accurately segmented, which is a tedious task for clinicians. In this paper, we proposed a double-branch residual-structured U-Net (DB-ResUNet) based on 3D convolutional neural network (CNN) to automatically segment such brain gray matter nuclei. To better tradeoff between segmentation accuracy and the memory efficiency, the proposed DB-ResUNet fed image patches with high resolution and the patches with low resolution but larger field of view into the local and global branches, respectively. Experimental results revealed that by jointly using QSM and T$_\text{1}$ weighted imaging (T$_\text{1}$WI) as inputs, the proposed method was able to achieve better segmentation accuracy over its single-branch counterpart, as well as the conventional atlas-based method and the classical 3D-UNet structure. The susceptibility values and the volumes were also measured, which indicated that the measurements from the proposed DB-ResUNet are able to present high correlation with values from the manually annotated regions of interest.
△ Less
Submitted 3 August, 2020;
originally announced August 2020.
-
Optimization of the JUNO liquid scintillator composition using a Daya Bay antineutrino detector
Authors:
Daya Bay,
JUNO collaborations,
:,
A. Abusleme,
T. Adam,
S. Ahmad,
S. Aiello,
M. Akram,
N. Ali,
F. P. An,
G. P. An,
Q. An,
G. Andronico,
N. Anfimov,
V. Antonelli,
T. Antoshkina,
B. Asavapibhop,
J. P. A. M. de André,
A. Babic,
A. B. Balantekin,
W. Baldini,
M. Baldoncini,
H. R. Band,
A. Barresi,
E. Baussan
, et al. (642 additional authors not shown)
Abstract:
To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were…
▽ More
To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were increased in 12 steps from 0.5 g/L and <0.01 mg/L to 4 g/L and 13 mg/L, respectively. The numbers of total detected photoelectrons suggest that, with the optically purified solvent, the bis-MSB concentration does not need to be more than 4 mg/L. To bridge the one order of magnitude in the detector size difference between Daya Bay and JUNO, the Daya Bay data were used to tune the parameters of a newly developed optical model. Then, the model and tuned parameters were used in the JUNO simulation. This enabled to determine the optimal composition for the JUNO LS: purified solvent LAB with 2.5 g/L PPO, and 1 to 4 mg/L bis-MSB.
△ Less
Submitted 1 July, 2020;
originally announced July 2020.
-
TAO Conceptual Design Report: A Precision Measurement of the Reactor Antineutrino Spectrum with Sub-percent Energy Resolution
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Sebastiano Aiello,
Muhammad Akram,
Nawab Ali,
Fengpeng An,
Guangpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Enrico Bernieri,
David Biare
, et al. (568 additional authors not shown)
Abstract:
The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillator detector will be placed at about 30 m from a core of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be measured with sub-percent energy resolution, to provide a reference spectrum for future re…
▽ More
The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillator detector will be placed at about 30 m from a core of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be measured with sub-percent energy resolution, to provide a reference spectrum for future reactor neutrino experiments, and to provide a benchmark measurement to test nuclear databases. A spherical acrylic vessel containing 2.8 ton gadolinium-doped liquid scintillator will be viewed by 10 m^2 Silicon Photomultipliers (SiPMs) of >50% photon detection efficiency with almost full coverage. The photoelectron yield is about 4500 per MeV, an order higher than any existing large-scale liquid scintillator detectors. The detector operates at -50 degree C to lower the dark noise of SiPMs to an acceptable level. The detector will measure about 2000 reactor antineutrinos per day, and is designed to be well shielded from cosmogenic backgrounds and ambient radioactivities to have about 10% background-to-signal ratio. The experiment is expected to start operation in 2022.
△ Less
Submitted 18 May, 2020;
originally announced May 2020.
-
Higgs Physics at the HL-LHC and HE-LHC
Authors:
M. Cepeda,
S. Gori,
P. Ilten,
M. Kado,
F. Riva,
R. Abdul Khalek,
A. Aboubrahim,
J. Alimena,
S. Alioli,
A. Alves,
C. Asawatangtrakuldee,
A. Azatov,
P. Azzi,
S. Bailey,
S. Banerjee,
E. L. Barberio,
D. Barducci,
G. Barone,
M. Bauer,
C. Bautista,
P. Bechtle,
K. Becker,
A. Benaglia,
M. Bengala,
N. Berger
, et al. (352 additional authors not shown)
Abstract:
The discovery of the Higgs boson in 2012, by the ATLAS and CMS experiments, was a success achieved with only a percent of the entire dataset foreseen for the LHC. It opened a landscape of possibilities in the study of Higgs boson properties, Electroweak Symmetry breaking and the Standard Model in general, as well as new avenues in probing new physics beyond the Standard Model. Six years after the…
▽ More
The discovery of the Higgs boson in 2012, by the ATLAS and CMS experiments, was a success achieved with only a percent of the entire dataset foreseen for the LHC. It opened a landscape of possibilities in the study of Higgs boson properties, Electroweak Symmetry breaking and the Standard Model in general, as well as new avenues in probing new physics beyond the Standard Model. Six years after the discovery, with a conspicuously larger dataset collected during LHC Run 2 at a 13 TeV centre-of-mass energy, the theory and experimental particle physics communities have started a meticulous exploration of the potential for precision measurements of its properties. This includes studies of Higgs boson production and decays processes, the search for rare decays and production modes, high energy observables, and searches for an extended electroweak symmetry breaking sector. This report summarises the potential reach and opportunities in Higgs physics during the High Luminosity phase of the LHC, with an expected dataset of pp collisions at 14 TeV, corresponding to an integrated luminosity of 3 ab$^{-1}$. These studies are performed in light of the most recent analyses from LHC collaborations and the latest theoretical developments. The potential of an LHC upgrade, colliding protons at a centre-of-mass energy of 27 TeV and producing a dataset corresponding to an integrated luminosity of 15 ab$^{-1}$, is also discussed.
△ Less
Submitted 19 March, 2019; v1 submitted 31 January, 2019;
originally announced February 2019.