-
Demonstration of a Mobile Optical Clock Ensemble at Sea
Authors:
E. Ahern,
J. W. Allison,
C. Billington,
N. Bourbeau Hébert,
A. P. Hilton,
E. Klantsataya,
C. Locke,
A. N. Luiten,
M. Nelligan,
R. F. Offer,
C. Perrella,
S. K. Scholten,
B. White,
B. M. Sparkes,
R. Beard,
J. D. Elgin,
K. W. Martin
Abstract:
Atomic clocks have been at the leading edge of accuracy and precision since their inception in the 1950s. However, typically the most capable of these clocks have been confined to laboratories despite the fact that there are compelling reasons to apply them in the field and/or while in motion. These applications include synchronization of distributed critical infrastructure (e.g. data servers, com…
▽ More
Atomic clocks have been at the leading edge of accuracy and precision since their inception in the 1950s. However, typically the most capable of these clocks have been confined to laboratories despite the fact that there are compelling reasons to apply them in the field and/or while in motion. These applications include synchronization of distributed critical infrastructure (e.g. data servers, communications, electricity grids), scientific applications (e.g. radio-astronomy) and to mitigate the effects of interruption to Global Navigation Satellite Systems.
Over the last 20 years, there has been a breakthrough in the performance of atomic clocks by transitioning from an atomic reference based on a microwave transition to an optical frequency transition. The $10^5$-fold increase in reference frequency confers the potential for significantly higher performance. However, this performance increase has come at the cost of size, complexity and fragility which has continued the confinement of these clocks to the laboratory.
Here we report on a recent international collaboration where three emerging optical clocks, each operating on different principles, were trialed at sea. These clocks incorporate optical frequency combs so that their stable frequency outputs can be used directly in electronic apparatus and were also automated so that they do not require expert supervision. We present the frequency stability and reliability of these three clocks over multiple weeks of unsupervised naval trials, both in harbour and on the ocean. The performance of all three devices was orders of magnitude superior to existing best-in-class commercial solutions over short and medium timescales. This demonstrates that optical clocks are ready to deliver advantages for real-world applications.
△ Less
Submitted 21 June, 2024; v1 submitted 5 June, 2024;
originally announced June 2024.
-
Correcting photodetector nonlinearity in dual-comb interferometry
Authors:
Philippe Guay,
Nicolas Bourbeau Hébert,
Alex Tourigny-Plante,
Vincent Michaud-Belleau,
Jérôme Genest
Abstract:
Photodetector nonlinearity, the main limiting factor in terms of optical power in the detection chain, is corrected to improve the signal-to-noise ratio of a short-time measurement in dual-comb spectroscopy. An iterative correction algorithm minimizing out-of-band spectral artifacts based on nonlinearity correction methods used in classical Fourier-transform spectrometers is presented. The exactit…
▽ More
Photodetector nonlinearity, the main limiting factor in terms of optical power in the detection chain, is corrected to improve the signal-to-noise ratio of a short-time measurement in dual-comb spectroscopy. An iterative correction algorithm minimizing out-of-band spectral artifacts based on nonlinearity correction methods used in classical Fourier-transform spectrometers is presented. The exactitude of the nonlinearity correction is validated using a low power linear measurement. Spectroscopic lines of H$^{12}$CN are provided and the error caused by the saturation of the detector is corrected yielding residuals limited by the measurement noise.
△ Less
Submitted 16 August, 2021; v1 submitted 5 July, 2021;
originally announced July 2021.
-
Understanding photodetector nonlinearity in dual-comb interferometry
Authors:
Philippe Guay,
Alex Tourigny-Plante,
Vincent Michaud-Belleau,
Nicolas Bourbeau Hébert,
Ariane Gouin,
Jérôme Genest
Abstract:
The impact of photodetector nonlinearity on dual-comb spectrometers is described and compared to that of Michelson-based Fourier transform spectrometers (FTS). The optical sampling occurring in the dual-comb approach, being the key difference with FTS, causes optical aliasing of the nonlinear spectral artifacts. Measured linear and nonlinear interferograms are presented to validate the model. Abso…
▽ More
The impact of photodetector nonlinearity on dual-comb spectrometers is described and compared to that of Michelson-based Fourier transform spectrometers (FTS). The optical sampling occurring in the dual-comb approach, being the key difference with FTS, causes optical aliasing of the nonlinear spectral artifacts. Measured linear and nonlinear interferograms are presented to validate the model. Absorption lines of H$^{13}$CN are provided to understand the impact of nonlinearity on spectroscopic measurements.
△ Less
Submitted 15 June, 2021;
originally announced June 2021.
-
Dual-comb correction with spectrally broadened fiber lasers
Authors:
Philippe Guay,
Alex Tourigny-Plante,
Nicolas Bourbeau Hébert,
Vincent Michaud-Belleau,
Steeve Larouche,
Khaoula Fdil,
Jérôme Genest
Abstract:
The phase information provided by the beat note between frequency combs and two continuous-wave lasers is used to extrapolate the phase evolution of comb modes found in a spectral region obtained via nonlinear broadening. This thereafter enables using interferogram self-correction to fully retrieve the coherence of a dual-comb beat note between two independent fiber lasers. This approach allows to…
▽ More
The phase information provided by the beat note between frequency combs and two continuous-wave lasers is used to extrapolate the phase evolution of comb modes found in a spectral region obtained via nonlinear broadening. This thereafter enables using interferogram self-correction to fully retrieve the coherence of a dual-comb beat note between two independent fiber lasers. This approach allows to forego the $f - 2f$ self-referencing of both combs, which is a significant simplification. Broadband near-infrared methane spectroscopy has been conducted as a demonstration of the simplified system's preserved performance.
△ Less
Submitted 20 September, 2019;
originally announced September 2019.
-
Single-frequency mid-infrared chip laser with a sub-hertz Lorentzian linewidth
Authors:
Philippe Guay,
Jérôme Genest,
Vincent Michaud-Belleau,
Nicolas Bourbeau Hébert,
David G. Lancaster
Abstract:
A guided-wave chip laser operating in a single longitudinal mode at 2860 nm is presented. The cavity was set in the Littman-Metcalf configuration to achieve single-frequency operation with a side-mode suppression ratio above 33 dB. The chip laser's linewidth was found to be limited by mechanical fluctuations, but its Lorentzian contribution was estimated to be lower than 1 Hz using a heterodyne te…
▽ More
A guided-wave chip laser operating in a single longitudinal mode at 2860 nm is presented. The cavity was set in the Littman-Metcalf configuration to achieve single-frequency operation with a side-mode suppression ratio above 33 dB. The chip laser's linewidth was found to be limited by mechanical fluctuations, but its Lorentzian contribution was estimated to be lower than 1 Hz using a heterodyne technique. This demonstration incorporates a high coherence source with the simplicity provided by the compactness of chip lasers.
△ Less
Submitted 20 September, 2019;
originally announced September 2019.
-
Self-corrected chip-based dual-comb spectrometer
Authors:
Nicolas Bourbeau Hébert,
Jérôme Genest,
Jean-Daniel Deschênes,
Hugo Bergeron,
George Y. Chen,
Champak Khurmi,
David G. Lancaster
Abstract:
We present a dual-comb spectrometer based on two passively mode-locked waveguide lasers integrated in a single Er-doped ZBLAN chip. This original design yields two free-running frequency combs having a high level of mutual stability. We developed in parallel a self-correction algorithm that compensates residual relative fluctuations and yields mode-resolved spectra without the help of any referenc…
▽ More
We present a dual-comb spectrometer based on two passively mode-locked waveguide lasers integrated in a single Er-doped ZBLAN chip. This original design yields two free-running frequency combs having a high level of mutual stability. We developed in parallel a self-correction algorithm that compensates residual relative fluctuations and yields mode-resolved spectra without the help of any reference laser or control system. Fluctuations are extracted directly from the interferograms using the concept of ambiguity function, which leads to a significant simplification of the instrument that will greatly ease its widespread adoption. Comparison with a correction algorithm relying on a single-frequency laser indicates discrepancies of only 50 attoseconds on optical timings. The capacities of this instrument are finally demonstrated with the acquisition of a high-resolution molecular spectrum covering 20 nm. This new chip-based multi-laser platform is ideal for the development of high-repetition-rate, compact and fieldable comb spectrometers in the near- and mid-infrared.
△ Less
Submitted 27 February, 2017;
originally announced February 2017.
-
Ultrafast pulse generation in a mode-locked Erbium chip waveguide laser
Authors:
Champak Khurmi,
Nicolas Bourbeau Hébert,
Wen Qi Zhang,
Shahraam Afshar V.,
George Chen,
Jérôme Genest,
Tanya M. Monro,
David G Lancaster
Abstract:
We report mode-locked ~1550 nm output of transform-limited ~180 fs pulses from a large mode-area (diameter ~ 50 μm) guided-wave erbium fluorozirconate glass laser. The passively mode-locked oscillator generates pulses with 25 nm bandwidth at 156 MHz repetition rate and peak-power of 260 W. Scalability to higher repetition rate is demonstrated by transform-limited 410 fs pulse output at 1.3 GHz. To…
▽ More
We report mode-locked ~1550 nm output of transform-limited ~180 fs pulses from a large mode-area (diameter ~ 50 μm) guided-wave erbium fluorozirconate glass laser. The passively mode-locked oscillator generates pulses with 25 nm bandwidth at 156 MHz repetition rate and peak-power of 260 W. Scalability to higher repetition rate is demonstrated by transform-limited 410 fs pulse output at 1.3 GHz. To understand the origins of the broad spectral output, the laser cavity is simulated by using a numerical solution to the Ginzburg-Landau equation. This paper reports the widest bandwidth and shortest pulses achieved from an ultra-fast laser inscribed waveguide laser.
△ Less
Submitted 22 October, 2016;
originally announced October 2016.