-
Prediction of post-radiotherapy recurrence volumes in head and neck squamous cell carcinoma using 3D U-Net segmentation
Authors:
Denis Kutnár,
Ivan R Vogelius,
Katrin Elisabet Håkansson,
Jens Petersen,
Jeppe Friborg,
Lena Specht,
Mogens Bernsdorf,
Anita Gothelf,
Claus Kristensen,
Abraham George Smith
Abstract:
Locoregional recurrences (LRR) are still a frequent site of treatment failure for head and neck squamous cell carcinoma (HNSCC) patients.
Identification of high risk subvolumes based on pretreatment imaging is key to biologically targeted radiation therapy. We investigated the extent to which a Convolutional neural network (CNN) is able to predict LRR volumes based on pre-treatment 18F-fluorodeo…
▽ More
Locoregional recurrences (LRR) are still a frequent site of treatment failure for head and neck squamous cell carcinoma (HNSCC) patients.
Identification of high risk subvolumes based on pretreatment imaging is key to biologically targeted radiation therapy. We investigated the extent to which a Convolutional neural network (CNN) is able to predict LRR volumes based on pre-treatment 18F-fluorodeoxyglucose positron emission tomography (FDG-PET)/computed tomography (CT) scans in HNSCC patients and thus the potential to identify biological high risk volumes using CNNs.
For 37 patients who had undergone primary radiotherapy for oropharyngeal squamous cell carcinoma, five oncologists contoured the relapse volumes on recurrence CT scans. Datasets of pre-treatment FDG-PET/CT, gross tumour volume (GTV) and contoured relapse for each of the patients were randomly divided into training (n=23), validation (n=7) and test (n=7) datasets. We compared a CNN trained from scratch, a pre-trained CNN, a SUVmax threshold approach, and using the GTV directly.
The SUVmax threshold method included 5 out of the 7 relapse origin points within a volume of median 4.6 cubic centimetres (cc). Both the GTV contour and best CNN segmentations included the relapse origin 6 out of 7 times with median volumes of 28 and 18 cc respectively.
The CNN included the same or greater number of relapse volume POs, with significantly smaller relapse volumes. Our novel findings indicate that CNNs may predict LRR, yet further work on dataset development is required to attain clinically useful prediction accuracy.
△ Less
Submitted 16 August, 2023;
originally announced August 2023.
-
Entanglement-assisted quantum communication with simple measurements
Authors:
Amélie Piveteau,
Jef Pauwels,
Emil Håkansson,
Sadiq Muhammad,
Mohamed Bourennane,
Armin Tavakoli
Abstract:
Dense coding is the seminal example of how entanglement can boost qubit communication, from sending one bit to sending two bits. This is made possible by projecting separate particles onto a maximally entangled basis. We investigate more general communication tasks, in both theory and experiment, and show that simpler measurements enable strong and sometimes even optimal entanglement-assisted qubi…
▽ More
Dense coding is the seminal example of how entanglement can boost qubit communication, from sending one bit to sending two bits. This is made possible by projecting separate particles onto a maximally entangled basis. We investigate more general communication tasks, in both theory and experiment, and show that simpler measurements enable strong and sometimes even optimal entanglement-assisted qubit communication protocols. Using only partial Bell state analysers for two qubits, we demonstrate quantum correlations that cannot be simulated with two bits of classical communication. Then, we show that there exists an established and operationally meaningful task for which product measurements are sufficient for the strongest possible quantum predictions based on a maximally entangled two-qubit state. Our results reveal that there are scenarios in which the power of entanglement in enhancing quantum communication can be harvested in simple and scalable optical experiments.
△ Less
Submitted 20 May, 2023; v1 submitted 19 May, 2022;
originally announced May 2022.
-
Experimental demonstration of full network nonlocality in the bilocal scenario
Authors:
E. Håkansson,
A. Piveteau,
S. Muhammad,
M. Bourennane
Abstract:
Quantum correlation between nodes in a network which consist of several independent sources of entanglement and in multipartite entanglement systems are important for general understanding of the nature of nonlocality, quantum information processing and communication. In previous years, demonstrations of network nonlocality for bilocal scenarios have been in the focus. Yet, it has been found that…
▽ More
Quantum correlation between nodes in a network which consist of several independent sources of entanglement and in multipartite entanglement systems are important for general understanding of the nature of nonlocality, quantum information processing and communication. In previous years, demonstrations of network nonlocality for bilocal scenarios have been in the focus. Yet, it has been found that the seminal protocols do not certify entanglement between end nodes, which otherwise require all sources in the network to be of nonlocal nature. This has motivated for development of even stronger concept, called full network nonlocality. Here, we experimentally demonstrate full network nonlocal correlations in a network. Specifically, we use two pairs of polarization entangled qubits created by two separate and independent entanglement sources and a partial Bell state measurement. Our results may pave the way for the use of nonlocality test in quantum communication protocols with a full network nonlocality certification.
△ Less
Submitted 23 January, 2022; v1 submitted 17 January, 2022;
originally announced January 2022.
-
A First Comparison of the responses of a He4-based fast-neutron detector and a NE-213 liquid-scintillator reference detector
Authors:
R. Jebali,
J. Scherzinger,
J. R. M. Annand,
R. Chandra,
G. Davatz,
K. G. Fissum,
H. Friederich,
U. Gendotti,
R. Hall-Wilton,
E. Håkansson,
K. Kanaki,
M. Lundin,
D. Murer,
B. Nilsson,
A. Rosborg,
H. Svensson
Abstract:
A first comparison has been made between the pulse-shape discrimination characteristics of a novel $^{4}$He-based pressurized scintillation detector and a NE-213 liquid-scintillator reference detector using an Am/Be mixed-field neutron and gamma-ray source and a high-resolution scintillation-pulse digitizer. In particular, the capabilities of the two fast neutron detectors to discriminate between…
▽ More
A first comparison has been made between the pulse-shape discrimination characteristics of a novel $^{4}$He-based pressurized scintillation detector and a NE-213 liquid-scintillator reference detector using an Am/Be mixed-field neutron and gamma-ray source and a high-resolution scintillation-pulse digitizer. In particular, the capabilities of the two fast neutron detectors to discriminate between neutrons and gamma-rays were investigated. The NE-213 liquid-scintillator reference cell produced a wide range of scintillation-light yields in response to the gamma-ray field of the source. In stark contrast, due to the size and pressure of the $^{4}$He gas volume, the $^{4}$He-based detector registered a maximum scintillation-light yield of 750~keV$_{ee}$ to the same gamma-ray field. Pulse-shape discrimination for particles with scintillation-light yields of more than 750~keV$_{ee}$ was excellent in the case of the $^{4}$He-based detector. Above 750~keV$_{ee}$ its signal was unambiguously neutron, enabling particle identification based entirely upon the amount of scintillation light produced.
△ Less
Submitted 27 April, 2015; v1 submitted 13 February, 2015;
originally announced February 2015.
-
Tagging fast neutrons from an 241Am/9Be source
Authors:
J. Scherzinger,
J. R. M. Annand,
G. Davatz,
K. G. Fissum,
U. Gendotti,
R. Hall-Wilton,
A. Rosborg,
E. Håkansson,
R. Jebali,
K. Kanaki,
M. Lundin,
B. Nilsson,
H. Svensson
Abstract:
We report on an investigation of the fast-neutron spectrum emitted by 241Am/9Be. Well-understood shielding, coincidence, and time-of-flight measurement techniques are employed to produce a continuous, polychromatic, energy-tagged neutron beam.
We report on an investigation of the fast-neutron spectrum emitted by 241Am/9Be. Well-understood shielding, coincidence, and time-of-flight measurement techniques are employed to produce a continuous, polychromatic, energy-tagged neutron beam.
△ Less
Submitted 3 January, 2015; v1 submitted 12 May, 2014;
originally announced May 2014.