The ABC130 barrel module prototy** programme for the ATLAS strip tracker
Authors:
Luise Poley,
Craig Sawyer,
Sagar Addepalli,
Anthony Affolder,
Bruno Allongue,
Phil Allport,
Eric Anderssen,
Francis Anghinolfi,
Jean-François Arguin,
Jan-Hendrik Arling,
Olivier Arnaez,
Nedaa Alexandra Asbah,
Joe Ashby,
Eleni Myrto Asimakopoulou,
Naim Bora Atlay,
Ludwig Bartsch,
Matthew J. Basso,
James Beacham,
Scott L. Beaupré,
Graham Beck,
Carl Beichert,
Laura Bergsten,
Jose Bernabeu,
Prajita Bhattarai,
Ingo Bloch
, et al. (224 additional authors not shown)
Abstract:
For the Phase-II Upgrade of the ATLAS Detector, its Inner Detector, consisting of silicon pixel, silicon strip and transition radiation sub-detectors, will be replaced with an all new 100 % silicon tracker, composed of a pixel tracker at inner radii and a strip tracker at outer radii. The future ATLAS strip tracker will include 11,000 silicon sensor modules in the central region (barrel) and 7,000…
▽ More
For the Phase-II Upgrade of the ATLAS Detector, its Inner Detector, consisting of silicon pixel, silicon strip and transition radiation sub-detectors, will be replaced with an all new 100 % silicon tracker, composed of a pixel tracker at inner radii and a strip tracker at outer radii. The future ATLAS strip tracker will include 11,000 silicon sensor modules in the central region (barrel) and 7,000 modules in the forward region (end-caps), which are foreseen to be constructed over a period of 3.5 years. The construction of each module consists of a series of assembly and quality control steps, which were engineered to be identical for all production sites. In order to develop the tooling and procedures for assembly and testing of these modules, two series of major prototy** programs were conducted: an early program using readout chips designed using a 250 nm fabrication process (ABCN-25) and a subsequent program using a follow-up chip set made using 130 nm processing (ABC130 and HCC130 chips). This second generation of readout chips was used for an extensive prototy** program that produced around 100 barrel-type modules and contributed significantly to the development of the final module layout. This paper gives an overview of the components used in ABC130 barrel modules, their assembly procedure and findings resulting from their tests.
△ Less
Submitted 7 September, 2020;
originally announced September 2020.
Updated Results of a Solid-State Sensor Irradiation Study for ILC Extreme Forward Calorimetry
Authors:
Paul Anderson,
Wyatt Crockett,
Luc D'Hauthuille,
Vitaliy Fadeyev,
Caleb Fink,
Cesar Gonzalez-Renteria,
Benjamin Gruey,
Jane Gunnell,
Forest Martinez-McKinney,
Greg Rischbieter,
Kyle Rocha,
Bruce A. Schumm,
Edwin Spencer,
Max Wilder
Abstract:
Detectors proposed for the International Linear Collider (ILC) incorporate a tungsten sampling calorimeter (`BeamCal') intended to reconstruct showers of electrons, positrons and photons that emerge from the interaction point of the collider with angles between 5 and 50 milliradians. For the innermost radius of this calorimeter, radiation doses at shower max are expected to reach 100 Mrad per year…
▽ More
Detectors proposed for the International Linear Collider (ILC) incorporate a tungsten sampling calorimeter (`BeamCal') intended to reconstruct showers of electrons, positrons and photons that emerge from the interaction point of the collider with angles between 5 and 50 milliradians. For the innermost radius of this calorimeter, radiation doses at shower max are expected to reach 100 Mrad per year, primarily due to minimum-ionizing electrons and positrons that arise in the induced electromagnetic showers of e$^+$e$^-$ `beamstrahlung' pairs produced in the ILC beam-beam interaction. However, radiation damage to calorimeter sensors may be dominated by hadrons induced by nuclear interactions of shower photons, which are much more likely to contribute to the non-ionizing energy loss that has been observed to damage sensors exposed to hadronic radiation. We report here on prior highlights and recent results of SLAC Experiment T-506, for which several different types of semiconductor sensors were exposed to doses of radiation induced by showering electrons of energy 3.5-13.3 GeV. By embedding the sensor under irradiation within a tungsten radiator, the exposure incorporated hadronic species that would potentially contribute to the degradation of a sensor mounted in a precision sampling calorimeter. Depending on sensor technology, significant post-irradiation charge collection was observed for doses of several hundred Mrad.
△ Less
Submitted 15 March, 2017;
originally announced March 2017.