-
Study experimental time resolution limits of recent ASICs at Weeroc with different SiPMs and scintillators
Authors:
Tasneem Saleem,
Salleh Ahmad,
Jean-Baptiste Cizel,
Christophe De La Taille,
Maxime Morenas,
Vanessa Nadig,
Florent Perez,
Volkmar Schulz,
Stefan Gundacker,
Julien Fleury
Abstract:
Medical applications, such as Positron Emission Tomography (PET), and space applications, such as Light Detection and Ranging (LIDAR), are in need of highly specialized ASICs. Weeroc, in collaboration with different partners, is highly involved in develo** a new generation of front-end ASICs. In the context of a joined LIDAR project among Weeroc, CNES, and Airbus, Weeroc is working on the develo…
▽ More
Medical applications, such as Positron Emission Tomography (PET), and space applications, such as Light Detection and Ranging (LIDAR), are in need of highly specialized ASICs. Weeroc, in collaboration with different partners, is highly involved in develo** a new generation of front-end ASICs. In the context of a joined LIDAR project among Weeroc, CNES, and Airbus, Weeroc is working on the development of Liroc, an ASIC for space LIDAR application. Weeroc is also working on advancing ASICs for medical applications with Radioroc under development and intended to be used for PET applications. This study experimentally evaluates the time resolution limits of these ASICs in different configurations, with some of the most recent silicon photomultiplier (SiPM) technologies available on the market, coupled to different scintillation crystals. The best single-photon time resolution (SPTR) was achieved using FBK NUV-HD SiPMs with an FWHM of 90 ps with Liroc and 73 ps with Radioroc. Furthermore, the coincidence time resolution (CTR) of Radioroc was studied with different crystal sizes. Using a large LYSO:Ce,Ca crystal of (3 x 3 x 20 mm3) with Broadcom Near UltraViolet-Metal in Trench (NUV-MT) yields a CTR of 127 ps (FWHM). The best CTR of Radioroc was determined to 83 ps (FWHM) with Broadcom NUV-MT SiPMs coupled to LYSO:Ce,Ca (2 x 2 x 3 mm3) from Taiwan Applied Crystal (TAC).
△ Less
Submitted 5 October, 2023; v1 submitted 24 May, 2023;
originally announced May 2023.
-
Sub-10 ps time tagging of electromagnetic showers with scintillating glasses and SiPMs
Authors:
Marco T. Lucchini,
Andrea Benaglia,
Stefan Gundacker,
Jack Illare,
Paul Lecoq,
Alfred A. Margaryan,
Ashot A. Margaryan,
Kristof Pauwels,
Etiennette Auffray
Abstract:
The high energy physics community has recently identified an $e^+e^-$ Higgs factory as one of the next-generation collider experiments, following the completion of the High Luminosity LHC program at CERN.The moderate radiation levels expected at such colliders compared to hadron colliders, enable the use of less radiation tolerant but cheaper technologies for the construction of the particle detec…
▽ More
The high energy physics community has recently identified an $e^+e^-$ Higgs factory as one of the next-generation collider experiments, following the completion of the High Luminosity LHC program at CERN.The moderate radiation levels expected at such colliders compared to hadron colliders, enable the use of less radiation tolerant but cheaper technologies for the construction of the particle detectors. This opportunity has triggered a renewed interest in the development of scintillating glasses for the instrumentation of large detector volumes such as homogeneous calorimeters. While the performance of such scintillators remains typically inferior in terms of light yield and radiation tolerance compared to that of many scintillating crystals, substantial progress has been made over the recent years. In this paper we discuss the time resolution of cerium-doped Alkali Free Fluorophosphate scintillating glasses, read-out with silicon photo-multipliers in detecting single charged tracks and at different positions along the longitudinal development of an electromagnetic shower, using respectively 150~GeV pions and 100~GeV electron beams at the CERN SPS H2 beam line. A single sensor time resolution of 14.4~ps and 5-7~ps was measured respectively in the two cases. With such a performance the present technology has the potential to address an emerging requirement of future detectors at collider experiments: measuring the time-of-flight of single charged particles as well as that of neutral particles showering inside the calorimeter and the time development of showers.
△ Less
Submitted 15 March, 2023; v1 submitted 6 December, 2022;
originally announced December 2022.
-
Test beam characterization of sensor prototypes for the CMS Barrel MIP Timing Detector
Authors:
R. Abbott,
A. Abreu,
F. Addesa,
M. Alhusseini,
T. Anderson,
Y. Andreev,
A. Apresyan,
R. Arcidiacono,
M. Arenton,
E. Auffray,
D. Bastos,
L. A. T. Bauerdick,
R. Bellan,
M. Bellato,
A. Benaglia,
M. Benettoni,
R. Bertoni,
M. Besancon,
S. Bharthuar,
A. Bornheim,
E. Brücken,
J. N. Butler,
C. Campagnari,
M. Campana,
R. Carlin
, et al. (174 additional authors not shown)
Abstract:
The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector, the Barrel Timing Layer (BTL), will be instrumented with LYSO:Ce crystals and Silicon Photomultipliers (SiPMs) providing a time resolution of about…
▽ More
The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector, the Barrel Timing Layer (BTL), will be instrumented with LYSO:Ce crystals and Silicon Photomultipliers (SiPMs) providing a time resolution of about 30 ps at the beginning of operation, and degrading to 50-60 ps at the end of the detector lifetime as a result of radiation damage. In this work, we present the results obtained using a 120 GeV proton beam at the Fermilab Test Beam Facility to measure the time resolution of unirradiated sensors. A proof-of-concept of the sensor layout proposed for the barrel region of the MTD, consisting of elongated crystal bars with dimensions of about 3 x 3 x 57 mm$^3$ and with double-ended SiPM readout, is demonstrated. This design provides a robust time measurement independent of the impact point of the MIP along the crystal bar. We tested LYSO:Ce bars of different thickness (2, 3, 4 mm) with a geometry close to the reference design and coupled to SiPMs manufactured by Hamamatsu and Fondazione Bruno Kessler. The various aspects influencing the timing performance such as the crystal thickness, properties of the SiPMs (e.g. photon detection efficiency), and impact angle of the MIP are studied. A time resolution of about 28 ps is measured for MIPs crossing a 3 mm thick crystal bar, corresponding to an MPV energy deposition of 2.6 MeV, and of 22 ps for the 4.2 MeV MPV energy deposition expected in the BTL, matching the detector performance target for unirradiated devices.
△ Less
Submitted 16 July, 2021; v1 submitted 15 April, 2021;
originally announced April 2021.
-
Observation of the rare $B^0_s\toμ^+μ^-$ decay from the combined analysis of CMS and LHCb data
Authors:
The CMS,
LHCb Collaborations,
:,
V. Khachatryan,
A. M. Sirunyan,
A. Tumasyan,
W. Adam,
T. Bergauer,
M. Dragicevic,
J. Erö,
M. Friedl,
R. Frühwirth,
V. M. Ghete,
C. Hartl,
N. Hörmann,
J. Hrubec,
M. Jeitler,
W. Kiesenhofer,
V. Knünz,
M. Krammer,
I. Krätschmer,
D. Liko,
I. Mikulec,
D. Rabady,
B. Rahbaran
, et al. (2807 additional authors not shown)
Abstract:
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six sta…
▽ More
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six standard deviations, and the best measurement of its branching fraction so far. Furthermore, evidence for the $B^0\toμ^+μ^-$ decay is obtained with a statistical significance of three standard deviations. The branching fraction measurements are statistically compatible with SM predictions and impose stringent constraints on several theories beyond the SM.
△ Less
Submitted 17 August, 2015; v1 submitted 17 November, 2014;
originally announced November 2014.