-
Transmission grating arrays for the X-ray spectrometer on Arcus Probe
Authors:
Ralf K. Heilmann,
Alexander R. Bruccoleri,
James A. Gregory,
Eric M. Gullikson,
Hans Moritz Günther,
Edward Hertz,
Renee D. Lambert,
Douglas J. Young,
Mark L. Schattenburg
Abstract:
The Arcus Probe mission concept has been submitted as an Astrophysics Probe Explorer candidate. It features two co-aligned high-resolution grating spectrometers: one for the soft x-ray band and one for the far UV. Together, these instruments can provide unprecedented performance to address important key questions about the structure and dynamics of our universe across a large range of length scale…
▽ More
The Arcus Probe mission concept has been submitted as an Astrophysics Probe Explorer candidate. It features two co-aligned high-resolution grating spectrometers: one for the soft x-ray band and one for the far UV. Together, these instruments can provide unprecedented performance to address important key questions about the structure and dynamics of our universe across a large range of length scales. The X-ray Spectrometer (XRS) consists of four parallel optical channels, each featuring an x-ray telescope with a fixed array of 216 lightweight, high-efficiency blazed transmission gratings, and two CCD readout arrays. Average spectral resolving power $λ/Δλ> 2,500$ ($\sim 3500$ expected) across the 12-50 Å\ band and combined effective area $> 350$ cm$^2$ ($> 470$ cm$^2$ expected) near OVII wavelengths are predicted, based on the measured x-ray performance of spectrometer prototypes and detailed ray trace modeling. We describe the optical and structural design of the grating arrays, from the macroscopic grating petals to the nanoscale gratings bars, grating fabrication, alignment, and x-ray testing. Recent x-ray diffraction efficiency results from chemically thinned grating bars are presented and show performance above mission assumptions.
△ Less
Submitted 24 May, 2024;
originally announced May 2024.
-
X-ray performance of critical-angle transmission grating prototypes for the Arcus mission
Authors:
Ralf K. Heilmann,
Alexander R. Bruccoleri,
Vadim Burwitz,
Casey deRoo,
Alan Garner,
Hans Moritz Guenther,
Eric M. Gullikson,
Gisela Hartner,
Ed Hertz,
Andreas Langmeier,
Thomas Mueller,
Surangkhana Rukdee,
Thomas Schmidt,
Randall K. Smith,
Mark L. Schattenburg
Abstract:
Arcus is a proposed soft x-ray grating spectrometer Explorer. It aims to explore cosmic feedback by map** hot gases within and between galaxies and galaxy clusters and characterizing jets and winds from supermassive black holes, and to investigate the dynamics of protoplanetary discs and stellar accretion. Arcus features 12 m-focal-length grazing-incidence silicon pore optics (SPO) developed for…
▽ More
Arcus is a proposed soft x-ray grating spectrometer Explorer. It aims to explore cosmic feedback by map** hot gases within and between galaxies and galaxy clusters and characterizing jets and winds from supermassive black holes, and to investigate the dynamics of protoplanetary discs and stellar accretion. Arcus features 12 m-focal-length grazing-incidence silicon pore optics (SPO) developed for the Athena mission. Critical-angle transmission (CAT) gratings efficiently disperse high diffraction orders onto CCDs. We report new and improved x-ray performance results for Arcus-like CAT gratings, including record resolving power for two co-aligned CAT gratings. Multiple Arcus prototype grating facets were illuminated by an SPO at the PANTER facility. The facets consist of $32\times32.5$ mm$^2$ patterned silicon membranes, bonded to metal frames. The bonding angle is adjusted according to the measured average tilt angle of the grating bars in the membrane. Two simultaneously illuminated facets show minor broadening of the Al-K$_α$ doublet in 18$^{\rm th}$ and 21$^{\rm st}$ orders with a best fit record effective resolving power of $R_G \approx 1.3^{+\infty}_{-0.5}\times10^4$ ($3σ$), about 3-4 times the Arcus requirement. We measured the diffraction efficiency of quasi-fully illuminated gratings at O-K wavelengths in orders 4-7 in an Arcus-like configuration and compare results with synchrotron spot measurements. After corrections for geometrical effects and bremsstrahlung continuum we find agreement between full and spot illumination at the two different facilities, as well as with the models used for Arcus effective area predictions. We find that these flight-like gratings meet diffraction efficiency and greatly exceed resolving power Arcus requirements.
△ Less
Submitted 17 June, 2022;
originally announced June 2022.
-
Calibration of the MaGIXS experiment II: Flight Instrument Calibration
Authors:
P. S. Athiray,
Amy R. Winebarger,
Patrick Champey,
Ken Kobayashi,
Sabrina Savage,
Brent Beabout,
Dyana Beabout,
David Broadway,
Alexander R. Bruccoleri,
Peter Cheimets,
Leon Golub,
Eric Gullikson,
Harlan Haight,
Ralf K. Heilmann,
Edward Hertz,
William Hogue,
Steven Johnson,
Jeffrey Kegley,
Jeffery Kolodziejczak,
Chad Madsen,
Mark L. Schattenburg,
Richard Siler,
Genevieve D. Vigil,
Ernest Wright
Abstract:
The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a sounding rocket experiment that observes the soft X-ray spectrum of the Sun from 6.0 - 24 Angstrom (0.5 - 2.0 keV), successfully launched on 30 July 2021. End-to-end alignment of the flight instrument and calibration experiments are carried out using the X-ray and Cryogenic Facility (XRCF) at NASA Marshall Space Flight Center. In this…
▽ More
The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a sounding rocket experiment that observes the soft X-ray spectrum of the Sun from 6.0 - 24 Angstrom (0.5 - 2.0 keV), successfully launched on 30 July 2021. End-to-end alignment of the flight instrument and calibration experiments are carried out using the X-ray and Cryogenic Facility (XRCF) at NASA Marshall Space Flight Center. In this paper, we present the calibration experiments of MaGIXS, which include wavelength calibration, measurement of line spread function, and determination of effective area. Finally, we use the measured instrument response function to predict the expected count rates for MaGIXS flight observation looking at a typical solar active region
△ Less
Submitted 3 September, 2021;
originally announced September 2021.
-
Near total reflection X-ray photoelectron spectroscopy: Quantifying chemistry at solid/liquid and solid/solid interfaces
Authors:
Henrique P. Martins,
Giuseppina Conti,
Isvar Cordova,
Lorenz Falling,
Heath Kersell,
Farhad Salmassi,
Eric Gullikson,
Inna Vishik,
Christoph Baeumer,
Patrick Naulleau,
Claus M. Schneider,
Slavomir Nemsak
Abstract:
Near total reflection regime has been widely used in X-ray science, specifically in grazing incidence small angle X-ray scattering and in hard X-ray photoelectron spectroscopy. In this work, we introduce some practical aspects of using near total reflection in ambient pressure X-ray photoelectron spectroscopy and apply this technique to study chemical concentration gradients in a substrate/photore…
▽ More
Near total reflection regime has been widely used in X-ray science, specifically in grazing incidence small angle X-ray scattering and in hard X-ray photoelectron spectroscopy. In this work, we introduce some practical aspects of using near total reflection in ambient pressure X-ray photoelectron spectroscopy and apply this technique to study chemical concentration gradients in a substrate/photoresist system. Experimental data are accompanied by X-ray optical and photoemission simulations to quantitatively probe the photoresist and the interface with the depth accuracy of ~1 nm. Together, our calculations and experiments confirm that near total reflection X-ray photoelectron spectroscopy is a suitable method to extract information from buried interfaces with highest depth-resolution, which can help address open research questions regarding our understanding of concentration profiles, electrical gradients, and charge transfer phenomena at such interfaces. The presented methodology is especially attractive for solid/liquid interface studies, since it provides all the strengths of a Bragg-reflection standing-wave spectroscopy without the need of an artificial multilayer mirror serving as a standing wave generator, thus dramatically simplifying the sample synthesis.
△ Less
Submitted 13 August, 2021;
originally announced August 2021.
-
A Small Satellite Version of a Broad-band Soft X-ray Polarimeter
Authors:
Herman L. Marshall,
Sarah N. T. Heine,
Alan Garner,
Eric M. Gullikson,
H. Moritz Günther,
Christopher Leitz,
Rebecca Masterson,
Eric D. Miller,
William Zhang,
Rozenn Boissay-Malaquin,
Ilaria Caiazzo,
Deepto Chakrabarty,
Rosemary Davidson,
Luigi C. Gallo,
Ralf K. Heilmann,
Jeremy Heyl,
Erin Kara,
Alan Marscher,
Norbert S. Schulz
Abstract:
We describe a new implementation of a broad-band soft X-ray polarimeter, substantially based on a previous design. This implementation, the Pioneer Soft X-ray Polarimeter (PiSoX) is a SmallSat, designed for NASA's call for Astrophysics Pioneers, small missions that could be CubeSats, balloon experiments, or SmallSats. As in the REDSoX Polarimeter, the grating arrangement is designed optimally for…
▽ More
We describe a new implementation of a broad-band soft X-ray polarimeter, substantially based on a previous design. This implementation, the Pioneer Soft X-ray Polarimeter (PiSoX) is a SmallSat, designed for NASA's call for Astrophysics Pioneers, small missions that could be CubeSats, balloon experiments, or SmallSats. As in the REDSoX Polarimeter, the grating arrangement is designed optimally for the purpose of polarimetry with broad-band focussing optics by matching the dispersion of the spectrometer channels to laterally graded multilayers (LGMLs). The system can achieve polarization modulation factors over 90%. For PiSoX, the optics are lightweight Si mirrors in a one-bounce parabolic configuration. High efficiency, blazed gratings from opposite sectors are oriented to disperse to a LGML forming a channel covering the wavelength range from 35 to 75 Angstroms (165 - 350 eV). Upon satellite rotation, the intensities of the dispersed spectra, after reflection and polarizing by the LGMLs, give the three Stokes parameters needed to determine a source's linear polarization fraction and orientation. The design can be extended to higher energies as LGMLs are developed further. We describe examples of the potential scientific return from instruments based on this design.
△ Less
Submitted 4 December, 2020;
originally announced December 2020.
-
Two-dimensional electron systems in perovskite oxide heterostructures: Role of the polarity-induced substitutional defects
Authors:
Shih-Chieh Lin,
Cheng-Tai Kuo,
Yu-Cheng Shao,
Yi-De Chuang,
Jaap Geessinck,
Mark Huijben,
Jean-Pascal Rueff,
Ismael L. Graff,
Giuseppina Conti,
Yingying Peng,
Aaron Bostwick,
Eli Rotenberg,
Eric Gullikson,
Slavomír Nemšák,
Arturas Vailionis,
Nicolas Gauquelin,
Johan Verbeeck,
Giacomo Ghiringhelli,
Claus M. Schneider,
Charles S. Fadley
Abstract:
The discovery of a two-dimensional electron system (2DES) at the interfaces of perovskite oxides such as LaAlO3 and SrTiO3 has motivated enormous efforts in engineering interfacial functionalities with this type of oxide heterostructures. However, its fundamental origins are still not understood, e.g. the microscopic mechanisms of coexisting interface conductivity and magnetism. Here we report a c…
▽ More
The discovery of a two-dimensional electron system (2DES) at the interfaces of perovskite oxides such as LaAlO3 and SrTiO3 has motivated enormous efforts in engineering interfacial functionalities with this type of oxide heterostructures. However, its fundamental origins are still not understood, e.g. the microscopic mechanisms of coexisting interface conductivity and magnetism. Here we report a comprehensive spectroscopic investigation of the depth profile of 2DES-relevant Ti 3d interface carriers using depth- and element-specific techniques, standing-wave excited photoemission and resonant inelastic scattering. We found that one type of Ti 3d interface carriers, which give rise to the 2DES are located within 3 unit cells from the n-type interface in the SrTiO3 layer. Unexpectedly, another type of interface carriers, which are polarity-induced Ti-on-Al antisite defects, reside in the first 3 unit cells of the opposing LaAlO3 layer (~10 Å). Our findings provide a microscopic picture of how the localized and mobile Ti 3d interface carriers distribute across the interface and suggest that the 2DES and 2D magnetism at the LaAlO3/SrTiO3 interface have disparate explanations as originating from different types of interface carriers.
△ Less
Submitted 29 October, 2020; v1 submitted 21 December, 2019;
originally announced December 2019.
-
Interface properties and built-in potential profile of a LaCrO$_3$/SrTiO$_3$ superlattice determined by standing-wave excited photoemission spectroscopy
Authors:
Shih-Chieh Lin,
Cheng-Tai Kuo,
Ryan B. Comes,
Julien E. Rault,
Jean-Pascal Rueff,
Slavomir Nemšák,
Amina Taleb,
Jeffrey B. Kortright,
Julia Meyer-Ilse,
Eric Gullikson,
Peter V. Sushko,
Steven R. Spurgeon,
Mathias Gehlmann,
Mark E. Bowden,
Lukasz Plucinski,
Scott A. Chambers,
Charles S. Fadley
Abstract:
LaCrO$_3$ (LCO) / SrTiO$_3$ (STO) heterojunctions are intriguing due to a polar discontinuity along (001), two distinct and controllable interface structures [(LaO)$^+$/(TiO$_2$)$^0$ and (SrO)$^0$/(CrO$_2$)$^-$], and interface-induced polarization. In this study, we have used soft- and hard x-ray standing-wave excited photoemission spectroscopy (SW-XPS) to generate a quantitative determination of…
▽ More
LaCrO$_3$ (LCO) / SrTiO$_3$ (STO) heterojunctions are intriguing due to a polar discontinuity along (001), two distinct and controllable interface structures [(LaO)$^+$/(TiO$_2$)$^0$ and (SrO)$^0$/(CrO$_2$)$^-$], and interface-induced polarization. In this study, we have used soft- and hard x-ray standing-wave excited photoemission spectroscopy (SW-XPS) to generate a quantitative determination of the elemental depth profiles and interface properties, band alignments, and the depth distribution of the interface-induced built-in potentials in the two constituent oxides. We observe an alternating charged interface configuration: a positively charged (LaO)$^+$/(TiO$_2$)$^0$ intermediate layer at the LCO$_\textbf{top}$/STO$_\textbf{bottom}$ interface and a negatively charged (SrO)$^0$/(CrO$_2$)$^-$ intermediate layer at the STO$_\textbf{top}$/LCO$_\textbf{bottom}$ interface. Using core-level SW data, we have determined the depth distribution of species, including through the interfaces, and these results are in excellent agreement with scanning transmission electron microscopy and electron energy loss spectroscopy (STEM-EELS) map** of local structure and composition. SW-XPS also enabled deconvolution of the LCO-contributed and STO- contributed matrix-element-weighted density of states (MEWDOSs) from the valence band (VB) spectra for the LCO/STO superlattice (SL). Monitoring the VB edges of the deconvoluted MEWDOS shifts with a change in probing profile, the alternating charge- induced built-in potentials are observed in both constituent oxides. Finally, using a two-step simulation approach involving first core-level binding energy shifts and then valence-band modeling, the built-in potential gradients across the SL are resolved in detail and represented by the depth distribution of VB edges.
△ Less
Submitted 31 August, 2018; v1 submitted 27 February, 2018;
originally announced February 2018.
-
Depth-resolved resonant inelastic x-ray scattering at a superconductor/half-metallic ferromagnet interface through standing-wave excitation
Authors:
Cheng-Tai Kuo,
Shih-Chieh Lin,
Giacomo Ghiringhelli,
Yingying Peng,
Gabriella Maria De Luca,
Daniele Di Castro,
Davide Betto,
Mathias Gehlmann,
Tom Wijnands,
Mark Huijben,
Julia Meyer-Ilse,
Eric Gullikson,
Jeffrey B. Kortright,
Arturas Vailionis,
Nicolas Gauquelin,
Johan Verbeeck,
Timm Gerber,
Giuseppe Balestrino,
Nicholas B. Brookes,
Lucio Braicovich,
Charles S. Fadley
Abstract:
We demonstrate that combining standing-wave (SW) excitation with resonant inelastic x-ray scattering (RIXS) can lead to depth resolution and interface sensitivity for studying orbital and magnetic excitations in correlated oxide heterostructures. SW-RIXS has been applied to multilayer heterostructures consisting of a superconductor La$_{1.85}$Sr$_{0.15}$CuO$_{4}$(LSCO) and a half-metallic ferromag…
▽ More
We demonstrate that combining standing-wave (SW) excitation with resonant inelastic x-ray scattering (RIXS) can lead to depth resolution and interface sensitivity for studying orbital and magnetic excitations in correlated oxide heterostructures. SW-RIXS has been applied to multilayer heterostructures consisting of a superconductor La$_{1.85}$Sr$_{0.15}$CuO$_{4}$(LSCO) and a half-metallic ferromagnet La$_{0.67}$Sr$_{0.33}$MnO$_{3}$ (LSMO). Easily observable SW effects on the RIXS excitations were found in these LSCO/LSMO multilayers. In addition, we observe different depth distribution of the RIXS excitations. The magnetic excitations are found to arise from the LSCO/LSMO interfaces, and there is also a suggestion that one of the dd excitations comes from the interfaces. SW-RIXS measurements of correlated-oxide and other multilayer heterostructures should provide unique layer-resolved insights concerning their orbital and magnetic excitations, as well as a challenge for RIXS theory to specifically deal with interface effects.
△ Less
Submitted 6 December, 2018; v1 submitted 27 February, 2018;
originally announced February 2018.
-
Atomic-layer-resolved composition and electronic structure of the cuprate Bi$_2$Sr$_2$CaCu$_2$O$_{8+δ}$ from soft x-ray standing-wave photoemission
Authors:
Cheng-Tai Kuo,
Shih-Chieh Lin,
Giuseppina Conti,
Shu-Ting Pi,
Luca Moreschini,
Aaron Bostwick,
Julia Meyer-Ilse,
Eric Gullikson,
Jeffrey B. Kortright,
Slavomir Nemšák,
Julien E. Rault,
Patrick Le Fèvre,
François Bertran,
Andrés F. Santander-Syro,
Ivan A. Vartanyants,
Warren E. Pickett,
Romuald Saint-Martin,
Amina Taleb,
Charles S. Fadley
Abstract:
A major remaining challenge in the superconducting cuprates is the unambiguous differentiation of the composition and electronic structure of the CuO$_2$ layers and those of the intermediate layers. The large c axis for these materials permits employing soft x-ray (930.3 eV) standing wave (SW) excitation in photoemission that yields atomic layer-by-atomic layer depth resolution of these properties…
▽ More
A major remaining challenge in the superconducting cuprates is the unambiguous differentiation of the composition and electronic structure of the CuO$_2$ layers and those of the intermediate layers. The large c axis for these materials permits employing soft x-ray (930.3 eV) standing wave (SW) excitation in photoemission that yields atomic layer-by-atomic layer depth resolution of these properties. Applying SW photoemission to Bi$_2$Sr$_2$CaCu$_2$O$_{8+δ}$ yields the depth distribution of atomic composition and the layer-resolved densities of states. We detect significant Ca presence in the SrO layers and oxygen bonding to three different cations. The layer-resolved valence electronic structure is found to be strongly influenced by the supermodulation structure--as determined by comparison to DFT calculations, by Ca-Sr intermixing, and by the Cu 3d-3d Coulomb interaction, further clarifying the complex interactions in this prototypical cuprate. Measurements of this type for other quasi-two-dimensional materials with large-c represent a promising future direction.
△ Less
Submitted 24 September, 2018; v1 submitted 16 January, 2018;
originally announced January 2018.
-
Depth-Resolved Composition and Electronic Structure of Buried Layers and Interfaces in a LaNiO$_3$/SrTiO$_3$ Superlattice from Soft- and Hard- X-ray Standing-Wave Angle-Resolved Photoemission
Authors:
D. Eiteneer,
G. K. Pálsson,
S. Nemšák,
A. X. Gray,
A. M. Kaiser,
J. Son,
J. LeBeau,
G. Conti,
A. A. Greer,
A. Keqi,
A. Rattanachata,
A. Y. Saw,
A. Bostwick,
E. Rotenberg,
E. M. Gullikson,
S. Ueda,
K. Kobayashi,
A. Janotti,
C. G. Van de Walle,
A. Blanca-Romero,
R. Pentcheva,
C. M. Schneider,
S. Stemmer,
C. S. Fadley
Abstract:
LaNiO$_3$ (LNO) is an intriguing member of the rare-earth nickelates in exhibiting a metal-insulator transition for a critical film thickness of about 4 unit cells [Son et al., Appl. Phys. Lett. 96, 062114 (2010)]; however, such thin films also show a transition to a metallic state in superlattices with SrTiO$_3$ (STO) [Son et al., Appl. Phys. Lett. 97, 202109 (2010)]. In order to better understan…
▽ More
LaNiO$_3$ (LNO) is an intriguing member of the rare-earth nickelates in exhibiting a metal-insulator transition for a critical film thickness of about 4 unit cells [Son et al., Appl. Phys. Lett. 96, 062114 (2010)]; however, such thin films also show a transition to a metallic state in superlattices with SrTiO$_3$ (STO) [Son et al., Appl. Phys. Lett. 97, 202109 (2010)]. In order to better understand this transition, we have studied a strained LNO/STO superlattice with 10 repeats of [4 unit-cell LNO/3 unit-cell STO] grown on an (LaAlO$_3$)$_{0.3}$(Sr$_2$AlTaO$_6$)$_{0.7}$ substrate using soft x-ray standing-wave-excited angle-resolved photoemission (SWARPES), together with soft- and hard- x-ray photoemission measurements of core levels and densities-of-states valence spectra. The experimental results are compared with state-of-the-art density functional theory (DFT) calculations of band structures and densities of states. Using core-level rocking curves and x-ray optical modeling to assess the position of the standing wave, SWARPES measurements are carried out for various incidence angles and used to determine interface-specific changes in momentum-resolved electronic structure. We further show that the momentum-resolved behavior of the Ni 3d eg and t2g states near the Fermi level, as well as those at the bottom of the valence bands, is very similar to recently published SWARPES results for a related La$_{0.7}$Sr$_{0.3}$MnO$_3$/SrTiO$_3$ superlattice that was studied using the same technique (Gray et al., Europhysics Letters 104, 17004 (2013)), which further validates this experimental approach and our conclusions. Our conclusions are also supported in several ways by comparison to DFT calculations for the parent materials and the superlattice, including layer-resolved density-of-states results.
△ Less
Submitted 27 May, 2016; v1 submitted 22 October, 2015;
originally announced October 2015.
-
The Use of Laterally Graded Multilayer Mirrors for Soft X-ray Polarimetry
Authors:
Herman L. Marshall,
Norbert S. Schulz,
David L. Windt,
Eric M. Gullikson,
Eric Blake,
Dan Getty,
Zane McInturff
Abstract:
We present continued development of laterally graded multilayer mirrors (LGMLs) for a telescope design capable of measuring linear X-ray polarization over a broad spectral band. The multilayer-coated mirrors are used as Bragg reflectors at the Brewster angle. By matching to the dispersion of a spectrometer, one may take advantage of high multilayer reflectivities and achieve modulation factors ove…
▽ More
We present continued development of laterally graded multilayer mirrors (LGMLs) for a telescope design capable of measuring linear X-ray polarization over a broad spectral band. The multilayer-coated mirrors are used as Bragg reflectors at the Brewster angle. By matching to the dispersion of a spectrometer, one may take advantage of high multilayer reflectivities and achieve modulation factors over 50% over the entire 0.2-0.8 keV band. In Phase II of the polarimetry beam-line development, we demonstrated that the system provides 100% polarized X-rays at 0.525 keV (Marshall et al. 2013). Here, we present results from phase III of our development, where a LGML is used at the source and laterally manipulated in order to select and polarize X-rays from emission lines for a variety of source anodes. The beamline will then provide the capability to test polarimeter components across the 0.15-0.70 keV band. We also present plans for a suborbital rocket experiment designed to detect a polarization level of better than 10% for an active galactic nucleus.
△ Less
Submitted 17 July, 2014;
originally announced July 2014.
-
Progress toward a Soft X-ray Polarimeter
Authors:
Herman L. Marshall,
Norbert S. Schulz,
Brian Remlinger,
Eric S. Gentry,
David L. Windt,
Eric M. Gullikson
Abstract:
We are develo** instrumentation for a telescope design capable of measuring linear X-ray polarization over a broad-band using conventional spectroscopic optics. Multilayer-coated mirrors are key to this approach, being used as Bragg reflectors at the Brewster angle. By laterally grading the multilayer mirrors and matching to the dispersion of a spectrometer, one may take advantage of high multil…
▽ More
We are develo** instrumentation for a telescope design capable of measuring linear X-ray polarization over a broad-band using conventional spectroscopic optics. Multilayer-coated mirrors are key to this approach, being used as Bragg reflectors at the Brewster angle. By laterally grading the multilayer mirrors and matching to the dispersion of a spectrometer, one may take advantage of high multilayer reflectivities and achieve modulation factors over 50% over the entire 0.2-0.8 keV band. We present progress on laboratory work to demonstrate the capabilities of an existing laterally graded multilayer coated mirror pair. We also present plans for a suborbital rocket experiment designed to detect a polarization level of 12-17% for an active galactic nucleus in the 0.1-1.0 keV band.
△ Less
Submitted 17 September, 2013;
originally announced September 2013.
-
A Soft X-ray Beam-splitting Multilayer Optic for the NASA GEMS Bragg Reflection Polarimeter
Authors:
Ryan Allured,
Monica Fernandez-Perea,
Regina Soufli,
Jennifer B. Alameda,
Michael J. Pivovaroff,
Eric M. Gullikson,
Philip Kaaret
Abstract:
A soft X-ray, beam-splitting, multilayer optic has been developed for the Bragg Reflection Polarimeter (BRP) on the NASA Gravity and Extreme Magnetism Small Explorer Mission (GEMS). The optic is designed to reflect 0.5 keV X-rays through a 90 degree angle to the BRP detector, and transmit 2-10 keV X-rays to the primary polarimeter. The transmission requirement prevents the use of a thick substrate…
▽ More
A soft X-ray, beam-splitting, multilayer optic has been developed for the Bragg Reflection Polarimeter (BRP) on the NASA Gravity and Extreme Magnetism Small Explorer Mission (GEMS). The optic is designed to reflect 0.5 keV X-rays through a 90 degree angle to the BRP detector, and transmit 2-10 keV X-rays to the primary polarimeter. The transmission requirement prevents the use of a thick substrate, so a 2 micron thick polyimide membrane was used. Atomic force microscopy has shown the membrane to possess high spatial frequency roughness less than 0.2 nm rms, permitting adequate X-ray reflectance. A multilayer thin film was especially developed and deposited via magnetron sputtering with reflectance and transmission properties that satisfy the BRP requirements and with near-zero stress. Reflectance and transmission measurements of BRP prototype elements closely match theoretical predictions, both before and after rigorous environmental testing.
△ Less
Submitted 26 March, 2013;
originally announced March 2013.
-
Sensitivity of an image plate system in the XUV (60 eV < E < 900 eV)
Authors:
B. H. Failor,
E. M. Gullikson,
N. G. Link,
J. C. Riordan,
B. C. Wilson
Abstract:
Phosphor imaging plates (IPs) have been calibrated and proven useful for quantitative x-ray imaging in the 1 to over 1000 keV energy range. In this paper we report on calibration measurements made at XUV energies in the 60 to 900 eV energy range using beamline 6.3.2 at the Advanced Light Source at Lawrence Berkeley National Laboratory. We measured a sensitivity of ~25 plus or minus 15 counts/pJ ov…
▽ More
Phosphor imaging plates (IPs) have been calibrated and proven useful for quantitative x-ray imaging in the 1 to over 1000 keV energy range. In this paper we report on calibration measurements made at XUV energies in the 60 to 900 eV energy range using beamline 6.3.2 at the Advanced Light Source at Lawrence Berkeley National Laboratory. We measured a sensitivity of ~25 plus or minus 15 counts/pJ over the stated energy range which is compatible with the sensitivity of Si photodiodes that are used for time-resolved measurements. Our measurements at 900 eV are consistent with the measurements made by Meadowcroft et al. at ~1 keV.
△ Less
Submitted 6 February, 2012;
originally announced February 2012.