Contextual Isotope Ranking Criteria for Peak Identification in Gamma Spectroscopy Using a Large Database
Authors:
Alexis Aguilar-Arevalo,
Xavier Bertou,
Carles Canet,
Miguel A. Cruz-Pérez,
Alexander Deisting,
Adriana Dias,
Juan Carlos D'Olivo,
J. Francisco Favela-Pérez,
Estela A. Garcés,
Adiv González Muñoz,
Jaime Octavio Guerra-Pulido,
Javier Mancera-Alejandrez,
Daniel José Marín-Lámbarri,
Mauricio Martínez-Montero,
Jocelyn Monroe,
Sean Paling,
Simon Peeters,
Paul R. Scovell,
Cenk Türkoglu,
Eric Vázquez-Jáuregui,
Joseph Walding
Abstract:
Isotope identification is a recurrent problem in gamma spectroscopy with high purity germanium detectors. In this work, new strategies are introduced to facilitate this type of analysis. Five criteria are used to identify the parent isotopes making a query on a large database of gamma-lines from a multitude of isotopes producing an output list whose entries are sorted so that the gamma-lines with…
▽ More
Isotope identification is a recurrent problem in gamma spectroscopy with high purity germanium detectors. In this work, new strategies are introduced to facilitate this type of analysis. Five criteria are used to identify the parent isotopes making a query on a large database of gamma-lines from a multitude of isotopes producing an output list whose entries are sorted so that the gamma-lines with the highest chance of being present in a sample are placed at the top. A metric to evaluate the performance of the different criteria is introduced and used to compare them. Two of the criteria are found to be superior than the others: one based on fuzzy logic, and another that makes use of the gamma relative emission probabilities. A program called histoGe implements these criteria using a SQLite database containing the gamma-lines of isotopes which was parsed from WWW Table of Radioactive Isotopes. histoGe is Free Software and is provided along with the database so they can be used to analyze spectra obtained with generic gamma-ray detectors.
△ Less
Submitted 22 June, 2022;
originally announced June 2022.
-
Volume reduction of water samples to increase sensitivity for radioassay of lead contamination
Authors:
A. Aguilar-Arevalo,
C. Canet,
M. A. Cruz-Pérez,
A. Deisting,
A. Dias,
J. C. D'Olivo,
F. Favela-Pérez,
E. A. Garcés,
A. González Muñoz,
J. O. Guerra-Pulido,
J. Mancera-Alejandrez,
D. J. Marín-Lámbarri,
M. Martinez Montero,
J. R. Monroe,
S. Paling,
S. J. M. Peeters,
P. R. Scovell,
C. Türkoğlu,
E. Vázquez-Jáuregui,
J. Walding
Abstract:
The World Health Organisation (WHO) presents an upper limit for lead in drinking water of 10 parts per billion ppb. Typically, to reach this level of sensitivity, expensive metrology is required. To increase the sensitivity of low cost devices, this paper explores the prospects of using a volume reduction technique of a boiled water sample doped with Lead-210 ($^{210}Pb$), as a means to increase t…
▽ More
The World Health Organisation (WHO) presents an upper limit for lead in drinking water of 10 parts per billion ppb. Typically, to reach this level of sensitivity, expensive metrology is required. To increase the sensitivity of low cost devices, this paper explores the prospects of using a volume reduction technique of a boiled water sample doped with Lead-210 ($^{210}Pb$), as a means to increase the solute's concentration. $^{210}$Pb is a radioactive lead isotope and its concentration in a water sample can be measured with e.g. High Purity Germanium (HPGe) detectors at the Boulby Underground Germanium Suite. Concentrations close to the WHO limit have not been examined. This paper presents a measurement of the volume reduction technique retaining $99\pm(9)\%$ of $^{210}$Pb starting from a concentration of $1.9\times10^{-6}$ ppb before reduction and resulting in $2.63\times10^{-4}$ ppb after reduction. This work also applies the volume reduction technique to London tap water and reports the radioassay results from gamma counting in HPGe detectors. Among other radio-isotopes, $^{40}$K, $^{210}$Pb, $^{131}$I and $^{177}$Lu were identified at measured concentrations of $2.83\times10^{3}$ ppb, $2.55\times10^{-7}$ ppb, $5.06\times10^{-10}$ ppb and $5.84\times10^{-10}$ ppb in the London tap water sample. This technique retained $90\pm50\%$ of $^{40}$K. Stable lead was inferred from the same water sample at a measured concentration of 0.012 ppb, prior to reduction.
△ Less
Submitted 9 May, 2022;
originally announced May 2022.
-
PlomBOX -- development of a low-cost CMOS device for environmental monitoring
Authors:
A. Aguilar-Arevalo,
E. Alba Posse,
M. Alvarez,
H. Arnaldi,
H. Asorey,
X. Bertou,
A. Colque,
A. Deisting,
A. Dias,
J. C. D'Olivo,
F. Favela-Pérez,
Y. Gándola,
E. A. Garcés,
J. Gasulla,
M. Gómez Berisso,
A. González Muñoz,
J. O. Guerra-Pulido,
S. Gutierrez,
S. Jois,
J. Lipovetzky,
J. Lovera,
M. B. Lovino,
D. J. Marín-Lámbarri,
L. Marpegan,
D. Martín
, et al. (14 additional authors not shown)
Abstract:
This paper reports on the development of a novel CMOS device employing lead-sensing bacteria to assay lead in drinking water. The objective of the PlomBOX project is to develop a low-cost sensor (£10) which can expedite access to on-demand assay methods and thus help mitigate lead intake through contaminated drinking water. The project follows three development paths: a) Certain bacteria can fluor…
▽ More
This paper reports on the development of a novel CMOS device employing lead-sensing bacteria to assay lead in drinking water. The objective of the PlomBOX project is to develop a low-cost sensor (£10) which can expedite access to on-demand assay methods and thus help mitigate lead intake through contaminated drinking water. The project follows three development paths: a) Certain bacteria can fluoresce or change colour when in the presence of lead. A genetically modified strain of Escherichia coli sensitive to lead concentrations up to 10 ppb is being developed. This constitutes the biosensor that fluoresces in proportion to the presence of lead. b) Bacteria response is imaged using a microprocessor (ESP32) with a camera module. This constitutes the optical metrology component of the PlomBOX. c) Data acquisition and control of the PlomBOX is achieved through a Bluetooth connection with the PlomApp, a custom-developed mobile phone application. Data are sent from the PlomApp to a database where a bespoke automated analysis software provides a result of the lead concentration in a sample of water. This paper reports on the instrumentation challenges of develo** the electronics for the PlomBOX and on the first prototype.
△ Less
Submitted 10 January, 2022;
originally announced January 2022.
-
Characterization of Germanium Detectors for the First Underground Laboratory in Mexico
Authors:
A. Aguilar-Arevalo,
S. Alvarado-Mijangos,
X. Bertou,
C. Canet,
M. A. Cruz-Pérez,
A. Deisting,
A. Dias,
J. C. D'Olivo,
F. Favela-Pérez,
E. A. Garcés,
A. González Muñoz,
J. O. Guerra-Pulido,
J. Mancera-Alejandrez,
D. J. Marín-Lámbarri,
M. Martínez Montero,
J. Monroe,
C. Iván Ortega-Hernández,
S. Paling,
S. Peeters,
D. Ruíz Esparza Rodríguez,
P. R. Scovell,
C. Türkoğlu,
E. Vázquez-Jáuregui,
J. Walding
Abstract:
This article reports the characterization of two High Purity Germanium detectors performed by extracting and comparing their efficiencies using experimental data and Monte Carlo simulations. The efficiencies were calculated for pointlike $γ$-ray sources as well as for extended calibration sources. Characteristics of the detectors such as energy linearity, energy resolution, and full energy peak ef…
▽ More
This article reports the characterization of two High Purity Germanium detectors performed by extracting and comparing their efficiencies using experimental data and Monte Carlo simulations. The efficiencies were calculated for pointlike $γ$-ray sources as well as for extended calibration sources. Characteristics of the detectors such as energy linearity, energy resolution, and full energy peak efficiencies are reported from measurements performed on surface laboratories. The detectors will be deployed in a $γ$-ray assay facility that will be located in the first underground laboratory in Mexico, Laboratorio Subterráneo de Mineral del Chico (LABChico), in the Comarca Minera UNESCO Global Geopark
△ Less
Submitted 24 September, 2020;
originally announced September 2020.
-
Dosimetry and calorimetry performance of a scientific CMOS camera for environmental monitoring
Authors:
Alexis Aguilar-Arevalo,
Xavier Bertou,
Carles Canet,
Miguel Angel Cruz-Perez,
Alexander Deisting,
Adriana Dias,
Juan Carlos D'Olivo,
Francisco Favela-Perez,
Estela A. Garces,
Adiv Gonzalez Munoz,
Jaime Octavio Guerra-Pulido,
Javier Mancera-Alejandrez,
Daniel Jose Marin-Lambarri,
Mauricio Martinez Montero,
Jocelyn Monroe,
Sean Paling,
Simon J. M. Peeters,
Paul Scovell,
Cenk Turkoglu,
Eric Vazquez-Jauregui,
Joseph Walding
Abstract:
This paper explores the prospect of CMOS devices to assay lead in drinking water, using calorimetry. Lead occurs together with traces of radioisotopes, e.g. Lead-210, producing $γ$-emissions with energies ranging from 10 keV to several 100 keV when they decay; this range is detectable in silicon sensors. In this paper we test a CMOS camera (Oxford Instruments Neo 5.5) for its general performance a…
▽ More
This paper explores the prospect of CMOS devices to assay lead in drinking water, using calorimetry. Lead occurs together with traces of radioisotopes, e.g. Lead-210, producing $γ$-emissions with energies ranging from 10 keV to several 100 keV when they decay; this range is detectable in silicon sensors. In this paper we test a CMOS camera (Oxford Instruments Neo 5.5) for its general performance as a detector of x-rays and low energy $γ$-rays and assess its sensitivity relative to the World Health Organization upper limit on lead in drinking water. Energies from 6 keV to 60 keV are examined. The CMOS camera has a linear energy response over this range and its energy resolution is for the most part slightly better than 2 %. The Neo sCMOS is not sensitive to x-rays with energies below $\sim\!\!10 keV$. The smallest detectable rate is 40$\pm$3 mHz, corresponding to an incident activity on the chip of 7$\pm$4 Bq. The estimation of the incident activity sensitivity from the detected activity relies on geometric acceptance and the measured efficiency vs. energy. We report the efficiency measurement, which is 0.08$\pm$0.02 % (0.0011$\pm$0.0002 %) at 26.3 keV (59.5 keV). Taking calorimetric information into account we measure a minimal detectable rate of 4$\pm$1 mHz (1.5$\pm$0.1 mHz) for 26.3 keV (59.5 keV) $γ$-rays, which corresponds to an incident activity of 1.0$\pm$0.6 Bq (57$\pm$33 Bq). Toy Monte Carlo and Geant4 simulations agree with these results. These results show this CMOS sensor is well-suited as a $γ$- and x-ray detector with sensitivity at the few to 100 ppb level for Lead-210 in a sample.
△ Less
Submitted 23 September, 2020;
originally announced September 2020.