Beam test measurements of Low Gain Avalanche Detector single pads and arrays for the ATLAS High Granularity Timing Detector
Authors:
C. Allaire,
J. Benitez,
M. Bomben,
G. Calderini,
M. Carulla,
E. Cavallaro,
A. Falou,
D. Flores,
P. Freeman,
Z. Galloway,
E. L. Gkougkousis,
H. Grabas,
S. Grinstein,
B. Gruey,
S. Guindon,
A. M. Henriques Correia,
S. Hidalgo,
A. Kastanas,
C. Labitan,
D. Lacour,
J. Lange,
F. Lanni,
B. Lenzi,
Z. Luce,
N. Makovec
, et al. (19 additional authors not shown)
Abstract:
For the high luminosity upgrade of the LHC at CERN, ATLAS is considering the addition of a High Granularity Timing Detector (HGTD) in front of the end cap and forward calorimeters at |z| = 3.5 m and covering the region 2.4 < |η| < 4 to help reducing the effect of pile-up. The chosen sensors are arrays of 50 μm thin Low Gain Avalanche Detectors (LGAD). This paper presents results on single LGAD sen…
▽ More
For the high luminosity upgrade of the LHC at CERN, ATLAS is considering the addition of a High Granularity Timing Detector (HGTD) in front of the end cap and forward calorimeters at |z| = 3.5 m and covering the region 2.4 < |η| < 4 to help reducing the effect of pile-up. The chosen sensors are arrays of 50 μm thin Low Gain Avalanche Detectors (LGAD). This paper presents results on single LGAD sensors with a surface area of 1.3x1.3 mm2 and arrays with 2x2 pads with a surface area of 2x2 mm^2 or 3x3 mm^2 each and different implant doses of the p+ multiplication layer. They are obtained from data collected during a beam test campaign in Autumn 2016 with a pion beam of 120 GeV energy at the CERN SPS. In addition to several quantities measured inclusively for each pad, the gain, efficiency and time resolution have been estimated as a function of the position of the incident particle inside the pad by using a beam telescope with a position resolution of few μm. Different methods to measure the time resolution are compared, yielding consistent results. The sensors with a surface area of 1.3x1.3 mm^2 have a time resolution of about 40 ps for a gain of 20 and of about 27 ps for a gain of 50 and fulfill the HGTD requirements. Larger sensors have, as expected, a degraded time resolution. All sensors show very good efficiency and time resolution uniformity.
△ Less
Submitted 9 August, 2018; v1 submitted 2 April, 2018;
originally announced April 2018.
-
Properties of HPK UFSD after neutron irradiation up to 6e15 n/cm2
Authors:
Z. Galloway,
V. Fadeyev,
P. Freeman,
E. Gkougkousis,
B. Gruey,
C. A. Labitan,
Z. Luce,
F. McKinney-Martinez,
H. F. -W. Sadrozinski,
A. Seiden,
E. Spencer,
M. Wilder,
N. Woods,
A. Zatserklyaniy,
Y. Zhao,
N. Cartiglia,
M. Ferrero,
S. Giordanengo,
M. Mandurrino,
A. Staiano,
V. Sola,
F. Cenna,
F. Fausti,
R. Arcidiacono,
F. Carnasecchi
, et al. (5 additional authors not shown)
Abstract:
In this paper we report results from a neutron irradiation campaign of Ultra-Fast Silicon Detectors (UFSD) with fluences of 1e14, 3e14, 6e14, 1e15, 3e15, 6e15 n/cm2. The UFSD used in this study are circular 50 micro-meter thick Low-Gain Avalanche Detectors (LGAD), with a 1.0 mm diameter active area. They have been produced by Hamamatsu Photonics (HPK), Japan, with pre-radiation internal gain in th…
▽ More
In this paper we report results from a neutron irradiation campaign of Ultra-Fast Silicon Detectors (UFSD) with fluences of 1e14, 3e14, 6e14, 1e15, 3e15, 6e15 n/cm2. The UFSD used in this study are circular 50 micro-meter thick Low-Gain Avalanche Detectors (LGAD), with a 1.0 mm diameter active area. They have been produced by Hamamatsu Photonics (HPK), Japan, with pre-radiation internal gain in the range 10-100 depending on the bias voltage. The sensors were tested pre-irradiation and post-irradiation with minimum ionizing particle (MIPs) from a 90Sr based \b{eta}-source. The leakage current, internal gain and the timing resolution were measured as a function of bias voltage at -20C and -30C. The timing resolution was extracted from the time difference with a second calibrated UFSD in coincidence, using the constant fraction method for both. The dependence of the gain upon the irradiation fluence is consistent with the concept of acceptor removal and the gain decreases from about 80 pre-irradiation to 7 after a fluence of 6e15 n/cm2. Consequently, the timing resolution was found to deteriorate from 20 ps to 50 ps. The results indicate that the most accurate time resolution is obtained at a value of the constant fraction discriminator (CFD) threshold used to determine the time of arrival varying with fluence, from 10% pre-radiation to 60% at the highest fluence. Key changes to the pulse shape induced by irradiation, i.e. (i) a reduce sensitivity of the pulse shape on the initial non-uniform charge deposition, (ii) the shortening of the rise time and (iii) the reduced pulse height, were compared with the WF2 simulation program and found to be in agreement.
△ Less
Submitted 10 April, 2020; v1 submitted 16 July, 2017;
originally announced July 2017.
-
Updated Results of a Solid-State Sensor Irradiation Study for ILC Extreme Forward Calorimetry
Authors:
Paul Anderson,
Wyatt Crockett,
Luc D'Hauthuille,
Vitaliy Fadeyev,
Caleb Fink,
Cesar Gonzalez-Renteria,
Benjamin Gruey,
Jane Gunnell,
Forest Martinez-McKinney,
Greg Rischbieter,
Kyle Rocha,
Bruce A. Schumm,
Edwin Spencer,
Max Wilder
Abstract:
Detectors proposed for the International Linear Collider (ILC) incorporate a tungsten sampling calorimeter (`BeamCal') intended to reconstruct showers of electrons, positrons and photons that emerge from the interaction point of the collider with angles between 5 and 50 milliradians. For the innermost radius of this calorimeter, radiation doses at shower max are expected to reach 100 Mrad per year…
▽ More
Detectors proposed for the International Linear Collider (ILC) incorporate a tungsten sampling calorimeter (`BeamCal') intended to reconstruct showers of electrons, positrons and photons that emerge from the interaction point of the collider with angles between 5 and 50 milliradians. For the innermost radius of this calorimeter, radiation doses at shower max are expected to reach 100 Mrad per year, primarily due to minimum-ionizing electrons and positrons that arise in the induced electromagnetic showers of e$^+$e$^-$ `beamstrahlung' pairs produced in the ILC beam-beam interaction. However, radiation damage to calorimeter sensors may be dominated by hadrons induced by nuclear interactions of shower photons, which are much more likely to contribute to the non-ionizing energy loss that has been observed to damage sensors exposed to hadronic radiation. We report here on prior highlights and recent results of SLAC Experiment T-506, for which several different types of semiconductor sensors were exposed to doses of radiation induced by showering electrons of energy 3.5-13.3 GeV. By embedding the sensor under irradiation within a tungsten radiator, the exposure incorporated hadronic species that would potentially contribute to the degradation of a sensor mounted in a precision sampling calorimeter. Depending on sensor technology, significant post-irradiation charge collection was observed for doses of several hundred Mrad.
△ Less
Submitted 15 March, 2017;
originally announced March 2017.
-
Beam test results of a 16 ps timing system based on ultra-fast silicon detectors
Authors:
N. Cartiglia,
A. Staiano,
V. Sola,
R. Arcidiacono,
R. Cirio,
F. Cenna,
M. Ferrero,
V. Monaco,
R. Mulargia,
M. Obertino,
F. Ravera,
R. Sacchi,
A. Bellora,
S. Durando,
M. Mandurrino,
N. Minafra,
V. Fadeyev,
P. Freeman,
Z. Galloway,
E. Gkougkousis,
H. Grabas,
B. Gruey,
C. A. Labitan,
R. Losakul,
Z. Luce
, et al. (18 additional authors not shown)
Abstract:
In this paper we report on the timing resolution of the first production of 50 micro-meter thick Ultra-Fast Silicon Detectors (UFSD) as obtained in a beam test with pions of 180 GeV/c momentum. UFSD are based on the Low-Gain Avalanche Detectors (LGAD) design, employing n-on-p silicon sensors with internal charge multiplication due to the presence of a thin, low-resistivity diffusion layer below th…
▽ More
In this paper we report on the timing resolution of the first production of 50 micro-meter thick Ultra-Fast Silicon Detectors (UFSD) as obtained in a beam test with pions of 180 GeV/c momentum. UFSD are based on the Low-Gain Avalanche Detectors (LGAD) design, employing n-on-p silicon sensors with internal charge multiplication due to the presence of a thin, low-resistivity diffusion layer below the junction. The UFSD used in this test belongs to the first production of thin (50 μm) sensors, with an pad area of 1.4 mm2. The gain was measured to vary between 5 and 70 depending on the bias voltage. The experimental setup included three UFSD and a fast trigger consisting of a quartz bar readout by a SiPM. The timing resolution, determined comparing the time of arrival of the particle in one or more UFSD and the trigger counter, for single UFSD was measured to be 35 ps for a bias voltage of 200 V, and 26 ps for a bias voltage of 240 V, and for the combination of 3 UFSD to be 20 ps for a bias voltage of 200 V, and 15 ps for a bias voltage of 240 V.
△ Less
Submitted 3 January, 2017; v1 submitted 30 August, 2016;
originally announced August 2016.
-
Updated Results of a Solid-State Sensor Irradiation Study for ILC Extreme Forward Calorimetry
Authors:
George Courcoubetis,
Wyatt Crockett,
Vitaliy Fadeyev,
Caleb Fink,
Nikolas Guillemaud,
Cesar Gonzalez Renteria,
Benjamin Gruey,
Patrick LaBarre,
Forest Martinez-McKinney,
Greg Rischbieter,
Bruce A. Schumm,
Edwin Spencer,
Max Wilder
Abstract:
Detectors proposed for the International Linear Collider (ILC) incorporate a tungsten sampling calorimeter (`BeamCal') intended to reconstruct showers of electrons, positrons and photons that emerge from the interaction point of the collider with angles between 5 and 50 milliradians. For the innermost radius of this calorimeter, radiation doses at shower max are expected to reach 100 Mrad per year…
▽ More
Detectors proposed for the International Linear Collider (ILC) incorporate a tungsten sampling calorimeter (`BeamCal') intended to reconstruct showers of electrons, positrons and photons that emerge from the interaction point of the collider with angles between 5 and 50 milliradians. For the innermost radius of this calorimeter, radiation doses at shower max are expected to reach 100 Mrad per year, primarily due to minimum-ionizing electrons and positrons that arise in the induced electromagnetic showers of e+e- `beamstrahlung' pairs produced in the ILC beam-beam interaction. However, radiation damage to calorimeter sensors may be dominated by hadrons induced by nuclear interactions of shower photons, which are much more likely to contribute to the non-ionizing energy loss that has been observed to damage sensors exposed to hadronic radiation. We report here on the results of SLAC Experiment T-506, for which several different types of silicon diode and gallium-arsenide sensors were exposed to doses of radiation induced by showering electrons of energy 3.5-13.3 GeV. By embedding the sensor under irradiation within a tungsten radiator, the exposure incorporated hadronic species that would potentially contribute to the degradation of a sensor mounted in a precision sampling calorimeter. Depending on sensor technology, efficient charge collection was observed for doses as large as 270 Mrad.
△ Less
Submitted 27 February, 2016;
originally announced February 2016.