-
Ultrafast Radiographic Imaging and Tracking: An overview of instruments, methods, data, and applications
Authors:
Zhehui Wang,
Andrew F. T. Leong,
Angelo Dragone,
Arianna E. Gleason,
Rafael Ballabriga,
Christopher Campbell,
Michael Campbell,
Samuel J. Clark,
Cinzia Da Vià,
Dana M. Dattelbaum,
Marcel Demarteau,
Lorenzo Fabris,
Kamel Fezzaa,
Eric R. Fossum,
Sol M. Gruner,
Todd Hufnagel,
Xiaolu Ju,
Ke Li,
Xavier Llopart,
Bratislav Lukić,
Alexander Rack,
Joseph Strehlow,
Audrey C. Therrien,
Julia Thom-Levy,
Feixiang Wang
, et al. (3 additional authors not shown)
Abstract:
Ultrafast radiographic imaging and tracking (U-RadIT) use state-of-the-art ionizing particle and light sources to experimentally study sub-nanosecond dynamic processes in physics, chemistry, biology, geology, materials science and other fields. These processes, fundamental to nuclear fusion energy, advanced manufacturing, green transportation and others, often involve one mole or more atoms, and t…
▽ More
Ultrafast radiographic imaging and tracking (U-RadIT) use state-of-the-art ionizing particle and light sources to experimentally study sub-nanosecond dynamic processes in physics, chemistry, biology, geology, materials science and other fields. These processes, fundamental to nuclear fusion energy, advanced manufacturing, green transportation and others, often involve one mole or more atoms, and thus are challenging to compute by using the first principles of quantum physics or other forward models. One of the central problems in U-RadIT is to optimize information yield through, e.g. high-luminosity X-ray and particle sources, efficient imaging and tracking detectors, novel methods to collect data, and large-bandwidth online and offline data processing, regulated by the underlying physics, statistics, and computing power. We review and highlight recent progress in: a.) Detectors; b.) U-RadIT modalities; c.) Data and algorithms; and d.) Applications. Hardware-centric approaches to U-RadIT optimization are constrained by detector material properties, low signal-to-noise ratio, high cost and long development cycles of critical hardware components such as ASICs. Interpretation of experimental data, including comparisons with forward models, is frequently hindered by sparse measurements, model and measurement uncertainties, and noise. Alternatively, U-RadIT make increasing use of data science and machine learning algorithms, including experimental implementations of compressed sensing. Machine learning and artificial intelligence approaches, refined by physics and materials information, may also contribute significantly to data interpretation, uncertainty quantification, and U-RadIT optimization.
△ Less
Submitted 4 September, 2023; v1 submitted 21 August, 2023;
originally announced August 2023.
-
ChatGPT for PLC/DCS Control Logic Generation
Authors:
Heiko Koziolek,
Sten Gruener,
Virendra Ashiwal
Abstract:
Large language models (LLMs) providing generative AI have become popular to support software engineers in creating, summarizing, optimizing, and documenting source code. It is still unknown how LLMs can support control engineers using typical control programming languages in programming tasks. Researchers have explored GitHub CoPilot or DeepMind AlphaCode for source code generation but did not yet…
▽ More
Large language models (LLMs) providing generative AI have become popular to support software engineers in creating, summarizing, optimizing, and documenting source code. It is still unknown how LLMs can support control engineers using typical control programming languages in programming tasks. Researchers have explored GitHub CoPilot or DeepMind AlphaCode for source code generation but did not yet tackle control logic programming. The contribution of this paper is an exploratory study, for which we created 100 LLM prompts in 10 representative categories to analyze control logic generation for of PLCs and DCS from natural language. We tested the prompts by generating answers with ChatGPT using the GPT-4 LLM. It generated syntactically correct IEC 61131-3 Structured Text code in many cases and demonstrated useful reasoning skills that could boost control engineer productivity. Our prompt collection is the basis for a more formal LLM benchmark to test and compare such models for control logic generation.
△ Less
Submitted 25 May, 2023;
originally announced May 2023.
-
Genetic Micro-Programs for Automated Software Testing with Large Path Coverage
Authors:
Jarrod Goschen,
Anna Sergeevna Bosman,
Stefan Gruner
Abstract:
Ongoing progress in computational intelligence (CI) has led to an increased desire to apply CI techniques for the purpose of improving software engineering processes, particularly software testing. Existing state-of-the-art automated software testing techniques focus on utilising search algorithms to discover input values that achieve high execution path coverage. These algorithms are trained on t…
▽ More
Ongoing progress in computational intelligence (CI) has led to an increased desire to apply CI techniques for the purpose of improving software engineering processes, particularly software testing. Existing state-of-the-art automated software testing techniques focus on utilising search algorithms to discover input values that achieve high execution path coverage. These algorithms are trained on the same code that they intend to test, requiring instrumentation and lengthy search times to test each software component. This paper outlines a novel genetic programming framework, where the evolved solutions are not input values, but micro-programs that can repeatedly generate input values to efficiently explore a software component's input parameter domain. We also argue that our approach can be generalised such as to be applied to many different software systems, and is thus not specific to merely the particular software component on which it was trained.
△ Less
Submitted 14 February, 2023;
originally announced February 2023.
-
Multi-scale time-resolved electron diffraction: A case study in moiré materials
Authors:
C. J. R. Duncan,
M. Kaemingk,
W. H. Li,
M. B. Andorf,
A. C. Bartnik,
A. Galdi,
M. Gordon,
C. A. Pennington,
I. V. Bazarov,
H. J. Zeng,
F. Liu,
D. Luo,
A. Sood,
A. M. Lindenberg,
M. W. Tate,
D. A. Muller,
J. Thom-Levy,
S. M. Gruner,
J. M. Maxson
Abstract:
Ultrafast-optical-pump -- structural-probe measurements, including ultrafast electron and x-ray scattering, provide direct experimental access to the fundamental timescales of atomic motion, and are thus foundational techniques for studying matter out of equilibrium. High-performance detectors are needed in scattering experiments to obtain maximum scientific value from every probe particle. We dep…
▽ More
Ultrafast-optical-pump -- structural-probe measurements, including ultrafast electron and x-ray scattering, provide direct experimental access to the fundamental timescales of atomic motion, and are thus foundational techniques for studying matter out of equilibrium. High-performance detectors are needed in scattering experiments to obtain maximum scientific value from every probe particle. We deploy a hybrid pixel array direct electron detector to perform ultrafast electron diffraction experiments on a WSe$_2$/MoSe$_2$ 2D heterobilayer, resolving the weak features of diffuse scattering and moiré superlattice structure without saturating the zero order peak. Enabled by the detector's high frame rate, we show that a chop** technique provides diffraction difference images with signal-to-noise at the shot noise limit. Finally, we demonstrate that a fast detector frame rate coupled with a high repetition rate probe can provide continuous time resolution from femtoseconds to seconds, enabling us to perform a scanning ultrafast electron diffraction experiment that maps thermal transport in WSe$_2$/MoSe$_2$ and resolves distinct diffusion mechanisms in space and time.
△ Less
Submitted 27 July, 2023; v1 submitted 16 June, 2022;
originally announced June 2022.
-
Characterization of 128x128 MM-PAD-2.1 ASIC: A Fast Framing Hard X-Ray Detector with High Dynamic Range
Authors:
D. Gadkari,
K. S. Shanks,
H. Hu,
H. T. Philipp,
M. W. Tate,
J. Thom-Levy,
S. M. Gruner
Abstract:
We characterize a new x-ray Mixed-Mode Pixel Array Detector (MM-PAD-2.1) Application Specific Integrated Circuit (ASIC). Using an integrating pixel front-end with dynamic charge removal architecture, the MM-PAD-2.1 ASIC extends the maximum measurable x-ray signal (in 20 keV photon units) to > 10$^{7}$ x-rays/pixel/frame while maintaining a low read noise across the full dynamic range, all while im…
▽ More
We characterize a new x-ray Mixed-Mode Pixel Array Detector (MM-PAD-2.1) Application Specific Integrated Circuit (ASIC). Using an integrating pixel front-end with dynamic charge removal architecture, the MM-PAD-2.1 ASIC extends the maximum measurable x-ray signal (in 20 keV photon units) to > 10$^{7}$ x-rays/pixel/frame while maintaining a low read noise across the full dynamic range, all while imaging continuously at a frame rate of up to 10 kHz. The in-pixel dynamic charge removal mechanism prevents saturation of the input amplifier and proceeds in parallel with signal integration to achieve deadtime-less measurements with incident x-ray rates of > 10$^{10}$ x-rays/pixel/s. The ASIC format consists of 128$\times$128 square pixels each 150 $μ$m on a side and is designed to be 3-side buttable so large arrays can be effectively tiled. Here we use both laboratory x-ray sources and the Cornell High Energy Synchrotron Source (CHESS) to characterize two single ASIC prototype detectors for both low (single x-ray) and high incident flux detection. In the first detector the ASIC was solder bump-bonded to a 500 $μ$m thick Si sensor for efficient detection of x-rays below ~20 keV, whereas the second detector used a 750 $μ$m thick CdTe sensor for x-rays above $\sim$ 20 keV.
△ Less
Submitted 16 February, 2022; v1 submitted 30 November, 2021;
originally announced December 2021.
-
Very-High Dynamic Range, 10,000 frames/second Pixel Array Detector for Electron Microscopy
Authors:
Hugh T. Philipp,
Mark W. Tate,
Katherine S. Shanks,
Luigi Mele,
Maurice Peemen,
Pleun Dona,
Reinout Hartong,
Gerard van Veen,
Yu-Tsun Shao,
Zhen Chen,
Julia Thom-Levy,
David A. Muller,
Sol M. Gruner
Abstract:
Precision and accuracy of quantitative scanning transmission electron microscopy (STEM) methods such as ptychography, and the map** of electric, magnetic and strain fields depend on the dose. Reasonable acquisition time requires high beam current and the ability to quantitatively detect both large and minute changes in signal. A new hybrid pixel array detector (PAD), the second-generation Electr…
▽ More
Precision and accuracy of quantitative scanning transmission electron microscopy (STEM) methods such as ptychography, and the map** of electric, magnetic and strain fields depend on the dose. Reasonable acquisition time requires high beam current and the ability to quantitatively detect both large and minute changes in signal. A new hybrid pixel array detector (PAD), the second-generation Electron Microscope Pixel Array Detector (EMPAD-G2), addresses this challenge by advancing the technology of a previous generation PAD, the EMPAD. The EMPAD-G2 images continuously at a frame-rates up to 10 kHz with a dynamic range that spans from low-noise detection of single electrons to electron beam currents exceeding 180 pA per pixel, even at electron energies of 300 keV. The EMPAD-G2 enables rapid collection of high-quality STEM data that simultaneously contain full diffraction information from unsaturated bright field disks to usable Kikuchi bands and higher-order Laue zones. Test results from 80 to 300 keV are presented, as are first experimental results demonstrating ptychographic reconstructions, strain and polarization maps. We introduce a new information metric, the Maximum Usable Imaging Speed (MUIS), to identify when a detector becomes electron-starved, saturated or its pixel count is mismatched with the beam current.
△ Less
Submitted 10 November, 2021;
originally announced November 2021.
-
Transferring Orbital Angular Momentum to an Electron Beam Reveals Toroidal and Chiral Order
Authors:
Kayla X. Nguyen,
Yi Jiang,
Michael C. Cao,
Prafull Purohit,
Ajay K. Yadav,
Pablo García-Fernández,
Mark W. Tate,
Celesta S. Chang,
Pablo Aguado-Puente,
Jorge Íñiguez,
Fernando Gomez-Ortiz,
Sol M. Gruner,
Javier Junquera,
Lane W. Martin,
Ramamoorthy Ramesh,
D. A. Muller
Abstract:
Orbital angular momentum and torque transfer play central roles in a wide range of magnetic textures and devices including skyrmions and spin-torque electronics(1-4). Analogous topological structures are now also being explored in ferroelectrics, including polarization vortex arrays in ferroelectric/dielectric superlattices(5). Unlike magnetic toroidal order, electric toroidal order does not coupl…
▽ More
Orbital angular momentum and torque transfer play central roles in a wide range of magnetic textures and devices including skyrmions and spin-torque electronics(1-4). Analogous topological structures are now also being explored in ferroelectrics, including polarization vortex arrays in ferroelectric/dielectric superlattices(5). Unlike magnetic toroidal order, electric toroidal order does not couple directly to linear external fields. To develop a mechanism that can control switching in polarization vortices, we utilize a high-energy electron beam and show that transverse currents are generated by polar order in the ballistic limit. We find that the presence of an electric toroidal moment in a ferro-rotational phase transfers a measurable torque and orbital angular momentum to the electron beam. Furthermore, we find that the complex polarization patterns, observed in these heterostructures, are microscopically chiral with a non-trivial axial component of the polarization. This chirality opens the door for the coupling of ferroelectric and optical properties.
△ Less
Submitted 9 December, 2020; v1 submitted 7 December, 2020;
originally announced December 2020.
-
Characterization of an architecture for front-end pixel binning in an integrating pixel array detector
Authors:
D. Gadkari,
K. S. Shanks,
H. T. Philipp,
M. W. Tate,
J. Thom-Levy,
S. M. Gruner
Abstract:
Optimization of an area detector involves compromises between various parameters like frame rate, read noise, dynamic range and pixel size. We have implemented and tested a novel front-end binning design in a photon-integrating hybrid pixel array detector using the MM-PAD-2.0 pixel architecture. In this architecture, the pixels can be optionally binned in a 2$\times$2 pixel configuration using a n…
▽ More
Optimization of an area detector involves compromises between various parameters like frame rate, read noise, dynamic range and pixel size. We have implemented and tested a novel front-end binning design in a photon-integrating hybrid pixel array detector using the MM-PAD-2.0 pixel architecture. In this architecture, the pixels can be optionally binned in a 2$\times$2 pixel configuration using a network of switches to selectively direct the output of 4 sensor pixels to a single amplifier input. Doing this allows a trade-off between frame rate and spatial resolution. Tests show that the binned pixels perform well, but with some degradation on performance as compared to an un-binned pixel. The increased parasitic input capacitance does reduce the signal collected per x-ray as well as increases the noise of the pixel. The increase in noise is, however, less than the factor of 2 increase one would observe for binning in post-processing. Spatial scans across the binned pixels show that no measured signal intensity is lost at the inner binning unit boundaries. In the high flux regime, at a 2$\times$2 pixel wide beam spot (FWHM) size, binned mode responds linearly up to a photon flux of ~10$^{7}$ x-rays/s, and performs comparably with un-binned mode up to a photon flux of ~10$^{8}$ x-rays/s. While this study demonstrates a proof of concept for front-end binning in integrating detectors, we also identify changes to this early-stage prototype which can further improve the performance of binning pixel structures.
△ Less
Submitted 5 November, 2020; v1 submitted 26 May, 2020;
originally announced May 2020.
-
High dynamic range CdTe mixed-mode pixel array detector (MM-PAD) for kilohertz imaging of hard x-rays
Authors:
Hugh T. Philipp,
Mark W. Tate,
Katherine S. Shanks,
Prafull Purohit,
Sol M. Gruner
Abstract:
A hard x-ray, high-speed, high dynamic range scientific x-ray imager is described. The imager is based on the mixed-mode pixel array detector (MM-PAD) readout chip coupled to a 750 micron thick cadmium telluride (CdTe) sensor. The full imager is a 2 x 3 tiled array of MM-PAD sensor/readout chip hybrids. CdTe improves detection for high energy x-rays as compared to silicon sensors, enabling efficie…
▽ More
A hard x-ray, high-speed, high dynamic range scientific x-ray imager is described. The imager is based on the mixed-mode pixel array detector (MM-PAD) readout chip coupled to a 750 micron thick cadmium telluride (CdTe) sensor. The full imager is a 2 x 3 tiled array of MM-PAD sensor/readout chip hybrids. CdTe improves detection for high energy x-rays as compared to silicon sensors, enabling efficient x-ray imaging to extend to >100 keV. The detector is capable of 1 kHz imaging and in-pixel circuitry has been designed to allow for well depths of greater than 4 x 10^{6} 80 keV x-rays. A charge integrating front-end allows for quantitative measurement of high flux x-ray images beyond the capabilities of photon counting detectors. Detector performance is summarized and experimental measurements are presented.
△ Less
Submitted 9 June, 2020; v1 submitted 7 April, 2020;
originally announced April 2020.
-
Experimental 3D Coherent Diffractive Imaging from photon-sparse random projections
Authors:
K. Giewekemeyer,
A. Aquila,
N. D. Loh,
Y. Chushkin,
K. S. Shanks,
J. Weiss,
M. W. Tate,
H. T. Philipp,
S. Stern,
P. Vagovic,
M. Mehrjoo,
C. Teo,
M. Barthelmess,
F. Zontone,
C. Chang,
R. C. Tiberio,
A. Sakdinawat,
G. J. Williams,
S. M. Gruner,
A. P. Mancuso
Abstract:
The routine atomic-resolution structure determination of single particles is expected to have profound implications for probing the structure-function relationship in systems ranging from energy materials to biological molecules. Extremely-bright, ultrashort-pulse X-ray sources---X-ray Free Electron Lasers (XFELs)---provide X-rays that can be used to probe ensembles of nearly identical nano-scale…
▽ More
The routine atomic-resolution structure determination of single particles is expected to have profound implications for probing the structure-function relationship in systems ranging from energy materials to biological molecules. Extremely-bright, ultrashort-pulse X-ray sources---X-ray Free Electron Lasers (XFELs)---provide X-rays that can be used to probe ensembles of nearly identical nano-scale particles. When combined with coherent diffractive imaging, these objects can be imaged; however, as the resolution of the images approaches the atomic scale, the measured data are increasingly difficult to obtain and, during an X-ray pulse, the number of photons incident on the two-dimensional detector is much smaller than the number of pixels. This latter concern, the signal "sparsity," materially impedes the application of the method. We demonstrate an experimental analog using a synchrotron X-ray source that yields signal levels comparable to those expected from single biomolecules illuminated by focused XFEL pulses. The analog experiment provides an invaluable cross-check on the fidelity of the reconstructed data that is not available during XFEL experiments. We establish---using this experimental data---that a sparsity of order $1.3\times10^{-3}$ photons per pixel per frame can be overcome, lending vital insight to the solution of the atomic-resolution XFEL single particle imaging problem by experimentally demonstrating 3D coherent diffractive imaging from photon-sparse random projections.
△ Less
Submitted 14 November, 2018;
originally announced November 2018.
-
Capillarity-Driven Oil Flow in Nanopores: Darcy Scale Analysis of Lucas-Washburn Imbibition Dynamics
Authors:
Simon Gruener,
Patrick Huber
Abstract:
We present gravimetrical and optical imaging experiments on the capillarity-driven imbibition of silicone oils in monolithic silica glasses traversed by 3D networks of pores (mesoporous Vycor glass with 6.5 nm or 10 nm pore diameters). As evidenced by a robust square-root-of-time Lucas-Washburn (L-W) filling kinetics, the capillary rise is governed by a balance of capillarity and viscous drag forc…
▽ More
We present gravimetrical and optical imaging experiments on the capillarity-driven imbibition of silicone oils in monolithic silica glasses traversed by 3D networks of pores (mesoporous Vycor glass with 6.5 nm or 10 nm pore diameters). As evidenced by a robust square-root-of-time Lucas-Washburn (L-W) filling kinetics, the capillary rise is governed by a balance of capillarity and viscous drag forces in the absence of inertia and gravitational effects over the entire experimental times studied, ranging from a few seconds up to 10 days. A video on the infiltration process corroborates a collective pore filling as well as pronounced imbibition front broadening resulting from the capillarity and permeability disorder, typical of Vycor glasses. The transport process is analyzed within a Darcy scale description, considering a generalized pre-factor of the L-W law, termed Lucas-Washburn-Darcy imbibition ability. It assumes a Hagen-Poiseuille velocity profile in the pores and depends on the porosity, the mean pore diameter, the tortuosity and the velocity slip length and thus on the effective hydraulic pore diameter. For both matrices a reduced imbibition speed and thus reduced imbibition ability, compared to the one assuming the nominal pore diameter, bulk fluidity and bulk capillarity, can be quantitatively traced to an immobile, pore-wall adsorbed boundary layer of 1.4 nm thickness. Presumably, it consists of a monolayer of water molecules adsorbed on the hydrophilic pore walls covered by a monolayer of flat-laying silicone oil molecules. Our study highlights the importance of immobile nanoscopic boundary layers on the flow in tight oil reservoirs as well as the validity of the Darcy scale description for transport in mesoporous media.
△ Less
Submitted 6 August, 2018;
originally announced August 2018.
-
Strain Map** of Two-Dimensional Heterostructures with Sub-Picometer Precision
Authors:
Yimo Han,
Kayla Nguyen,
Michael Cao,
Paul Cueva,
Saien Xie,
Mark W. Tate,
Prafull Purohit,
Sol M. Gruner,
Jiwoong Park,
David A. Muller
Abstract:
Next-generation, atomically thin devices require in-plane, one-dimensional heterojunctions to electrically connect different two-dimensional (2D) materials. However, the lattice mismatch between most 2D materials leads to unavoidable strain, dislocations, or ripples, which can strongly affect their mechanical, optical, and electronic properties. We have developed an approach to map 2D heterojuncti…
▽ More
Next-generation, atomically thin devices require in-plane, one-dimensional heterojunctions to electrically connect different two-dimensional (2D) materials. However, the lattice mismatch between most 2D materials leads to unavoidable strain, dislocations, or ripples, which can strongly affect their mechanical, optical, and electronic properties. We have developed an approach to map 2D heterojunction lattice and strain profiles with sub-picometer precision and to identify dislocations and out-of-plane ripples. We collected diffraction patterns from a focused electron beam for each real-space scan position with a high-speed, high dynamic range, momentum-resolved detector - the electron microscope pixel array detector (EMPAD). The resulting four-dimensional (4D) phase space datasets contain the full spatially resolved lattice information of the sample. By using this technique on tungsten disulfide (WS2) and tungsten diselenide (WSe2) lateral heterostructures, we have mapped lattice distortions with 0.3 pm precision across multi-micron fields of view and simultaneously observed the dislocations and ripples responsible for strain relaxation in 2D laterally-epitaxial structures.
△ Less
Submitted 24 January, 2018;
originally announced January 2018.
-
Deep sub-Ångstrom imaging of 2D materials with a high dynamic range detector
Authors:
Yi Jiang,
Zhen Chen,
Yimo Han,
Pratiti Deb,
Hui Gao,
Saien Xie,
Prafull Purohit,
Mark W. Tate,
Jiwoong Park,
Sol M. Gruner,
Veit Elser,
David A. Muller
Abstract:
Aberration-corrected optics have made electron microscopy at atomic-resolution a widespread and often essential tool for nanocharacterization. Image resolution is dominated by beam energy and the numerical aperture of the lens (α), with state-of-the-art reaching ~0.47 Å at 300 keV. Two-dimensional materials are imaged at lower beam energies to avoid knock-on damage, limiting spatial resolution to…
▽ More
Aberration-corrected optics have made electron microscopy at atomic-resolution a widespread and often essential tool for nanocharacterization. Image resolution is dominated by beam energy and the numerical aperture of the lens (α), with state-of-the-art reaching ~0.47 Å at 300 keV. Two-dimensional materials are imaged at lower beam energies to avoid knock-on damage, limiting spatial resolution to ~1 Å. Here, by combining a new electron microscope pixel array detector with the dynamic range to record the complete distribution of transmitted electrons and full-field ptychography to recover phase information from the full phase space, we increased the spatial resolution well beyond the traditional lens limitations. At 80 keV beam energy, our ptychographic reconstructions significantly improved image contrast of single-atom defects in MoS2, reaching an information limit close to 5α, corresponding to a 0.39 Å Abbe resolution, at the same dose and imaging conditions where conventional imaging modes reach only 0.98 Å.
△ Less
Submitted 14 January, 2018;
originally announced January 2018.
-
Characterization of Chromium Compensated GaAs as an x-ray Sensor Material for Charge-Integrating Pixel Array Detectors
Authors:
Julian Becker,
Mark W. Tate,
Katherine S. Shanks,
Hugh T. Philipp,
Joel T. Weiss,
Prafull Purohit,
Darol Chamberlain,
Sol M. Gruner
Abstract:
We studied the properties of chromium compensated GaAs when coupled to charge integrating ASICs as a function of detector temperature, applied bias and x-ray tube energy. The material is a photoresistor and can be biased to collect either electrons or holes by the pixel circuitry. Both are studied here. Previous studies have shown substantial hole trap**. This trap** and other sensor propertie…
▽ More
We studied the properties of chromium compensated GaAs when coupled to charge integrating ASICs as a function of detector temperature, applied bias and x-ray tube energy. The material is a photoresistor and can be biased to collect either electrons or holes by the pixel circuitry. Both are studied here. Previous studies have shown substantial hole trap**. This trap** and other sensor properties give rise to several non-ideal effects which include an extended point spread function, variations in the effective pixel size, and rate dependent offset shifts. The magnitude of these effects varies with temperature and bias, mandating good temperature uniformity in the sensor and very good temperature stabilization, as well as a carefully selected bias voltage.
△ Less
Submitted 21 November, 2017; v1 submitted 7 July, 2017;
originally announced July 2017.
-
Sub-Microsecond X-Ray Imaging Using Hole-Collecting Schottky type CdTe with Charge-Integrating Pixel Array Detectors
Authors:
Julian Becker,
Mark W. Tate,
Katherine S. Shanks,
Hugh T. Philipp,
Joel T. Weiss,
Prafull Purohit,
Darol Chamberlain,
Sol M. Gruner
Abstract:
CdTe is increasingly being used as the x-ray sensing material in imaging pixel array detectors for x-rays, generally above 20 keV, where silicon sensors become unacceptably transparent. Unfortunately CdTe suffers from polarization, which can alter the response of the material over time and with accumulated dose. Most prior studies used long integration times or CdTe that was not of the hole-collec…
▽ More
CdTe is increasingly being used as the x-ray sensing material in imaging pixel array detectors for x-rays, generally above 20 keV, where silicon sensors become unacceptably transparent. Unfortunately CdTe suffers from polarization, which can alter the response of the material over time and with accumulated dose. Most prior studies used long integration times or CdTe that was not of the hole-collecting Schottky type. We investigated the temporal response of hole-collecting Schottky type CdTe sensors on timescales ranging from tens of nanoseconds to several seconds. We found that the material shows signal persistence on the timescale of hundreds of milliseconds attributed to the detrap** of a shallow trap, and additional persistence on sub-microsecond timescales after polarization. The results show that this type of CdTe can be used for time resolved studies down to approximately 100 ns. However quantitative interpretation of the signal requires careful attention to bias voltages, polarization and exposure history.
△ Less
Submitted 15 May, 2017; v1 submitted 6 March, 2017;
originally announced March 2017.
-
High Dynamic Range X-ray Detector Pixel Architectures Utilizing Charge Removal
Authors:
Joel T. Weiss,
Katherine S. Shanks,
Hugh T. Philipp,
Julian Becker,
Darol Chamberlain,
Prafull Purohit,
Mark W. Tate,
Sol M. Gruner
Abstract:
Several charge integrating CMOS pixel front-ends utilizing charge removal techniques have been fabricated to extend dynamic range for x-ray diffraction applications at synchrotron sources and x-ray free electron lasers (XFELs). The pixels described herein build on the Mixed Mode Pixel Array Detector (MM-PAD) framework, developed previously by our group to perform high dynamic range imaging. These…
▽ More
Several charge integrating CMOS pixel front-ends utilizing charge removal techniques have been fabricated to extend dynamic range for x-ray diffraction applications at synchrotron sources and x-ray free electron lasers (XFELs). The pixels described herein build on the Mixed Mode Pixel Array Detector (MM-PAD) framework, developed previously by our group to perform high dynamic range imaging. These new pixels boast several orders of magnitude improvement in maximum flux over the MM-PAD, which is capable of measuring a sustained flux in excess of 10$^{8}$ x-rays/pixel/second while maintaining sensitivity to smaller signals, down to single x-rays. To extend dynamic range, charge is removed from the integration node of the front-end amplifier without interrupting integration. The number of times this process occurs is recorded by a digital counter in the pixel. The parameter limiting full well is thereby shifted from the size of an integration capacitor to the depth of a digital counter. The result is similar to that achieved by counting pixel array detectors, but the integrators presented here are designed to tolerate a sustained flux >10$^{11}$ x-rays/pixel/second. Pixel front-end linearity was evaluated by direct current injection and results are presented. A small-scale readout ASIC utilizing these pixel architectures has been fabricated and the use of these architectures to increase single x-ray pulse dynamic range at XFELs is discussed briefly.
△ Less
Submitted 28 October, 2016;
originally announced October 2016.
-
Characterization of CdTe Sensors with Schottky Contacts Coupled to Charge-Integrating Pixel Array Detectors for X-Ray Science
Authors:
Julian Becker,
Mark W. Tate,
Katherine S. Shanks,
Hugh T. Philipp,
Joel T. Weiss,
Prafull Purohit,
Darol Chamberlain,
Jacob P. C. Ruff,
Sol M. Gruner
Abstract:
Pixel Array Detectors (PADs) consist of an x-ray sensor layer bonded pixel-by-pixel to an underlying readout chip. This approach allows both the sensor and the custom pixel electronics to be tailored independently to best match the x-ray imaging requirements. Here we present characterizations of CdTe sensors hybridized with two different charge-integrating readout chips, the Keck PAD and the Mixed…
▽ More
Pixel Array Detectors (PADs) consist of an x-ray sensor layer bonded pixel-by-pixel to an underlying readout chip. This approach allows both the sensor and the custom pixel electronics to be tailored independently to best match the x-ray imaging requirements. Here we present characterizations of CdTe sensors hybridized with two different charge-integrating readout chips, the Keck PAD and the Mixed-Mode PAD (MM-PAD), both developed previously in our laboratory. The charge-integrating architecture of each of these PADs extends the instantaneous counting rate by many orders of magnitude beyond that obtainable with photon counting architectures. The Keck PAD chip consists of rapid, 8-frame, in-pixel storage elements with framing periods $<$150 ns. The second detector, the MM-PAD, has an extended dynamic range by utilizing an in-pixel overflow counter coupled with charge removal circuitry activated at each overflow. This allows the recording of signals from the single-photon level to tens of millions of x-rays/pixel/frame while framing at 1 kHz. Both detector chips consist of a 128$\times$128 pixel array with (150 $μ$m)$^2$ pixels.
△ Less
Submitted 28 November, 2016; v1 submitted 12 September, 2016;
originally announced September 2016.
-
Hydraulic Transport Across Hydrophilic and Hydrophobic Nanopores: Flow Experiments with Water and n-Hexane
Authors:
Simon Gruener,
Dirk Wallacher,
Stefanie Greulich,
Mark Busch,
Patrick Huber
Abstract:
We experimentally explore pressure-driven flow of water and n-hexane across nanoporous silica (Vycor glass monoliths with 7 or 10 nm pore diameters, respectively) as a function of temperature and surface functionalization (native and silanized glass surfaces). Hydraulic flow rates are measured by applying hydrostatic pressures via inert gases (argon and helium, pressurized up to 70 bar) on the ups…
▽ More
We experimentally explore pressure-driven flow of water and n-hexane across nanoporous silica (Vycor glass monoliths with 7 or 10 nm pore diameters, respectively) as a function of temperature and surface functionalization (native and silanized glass surfaces). Hydraulic flow rates are measured by applying hydrostatic pressures via inert gases (argon and helium, pressurized up to 70 bar) on the upstream side in a capacitor-based membrane permeability setup. For the native, hydrophilic silica walls, the measured hydraulic permeabilities can be quantitatively accounted for by bulk fluidity provided we assume a sticking boundary layer, i.e. a negative velocity slip length of molecular dimensions. The thickness of this boundary layer is discussed with regard to previous capillarity-driven flow experiments (spontaneous imbibition) and with regard to velocity slippage at the pore walls resulting from dissolved gas. Water flow across the silanized, hydrophobic nanopores is blocked up to a hydrostatic pressure of at least 70 bar. The absence of a sticking boundary layer quantitatively accounts for an enhanced n-hexane permeability in the hydrophobic compared to the hydrophilic nanopores.
△ Less
Submitted 12 December, 2015;
originally announced December 2015.
-
Capillary rise dynamics of liquid hydrocarbons in mesoporous silica as explored by gravimetry, optical and neutron imaging: Nano-rheology and determination of pore size distributions from the shape of imbibition fronts
Authors:
Simon Gruener,
Helen E. Hermes,
Burkhard Schillinger,
Stefan U. Egelhaaf,
Patrick Huber
Abstract:
We present gravimetrical, optical, and neutron imaging measurements of the capillarity-driven infiltration of mesoporous silica glass by hydrocarbons. Square-root-of-time Lucas-Washburn invasion kinetics are found for linear alkanes from n-decane (C10) to n-hexacontane (C60) and for squalane, a branched alkane, in porous Vycor with 6.5 nm or 10 nm pore diameter, respectively. Humidity-dependent ex…
▽ More
We present gravimetrical, optical, and neutron imaging measurements of the capillarity-driven infiltration of mesoporous silica glass by hydrocarbons. Square-root-of-time Lucas-Washburn invasion kinetics are found for linear alkanes from n-decane (C10) to n-hexacontane (C60) and for squalane, a branched alkane, in porous Vycor with 6.5 nm or 10 nm pore diameter, respectively. Humidity-dependent experiments allow us to study the influence on the imbibition kinetics of water layers adsorbed on the pore walls. Except for the longest molecule studied, C60, the invasion kinetics can be described by bulk fluidity and bulk capillarity, provided we assume a sticking, pore-wall adsorbed boundary layer, i.e. a monolayer of water covered by a monolayer of flat-laying hydrocarbons. For C60, however, an enhanced imbibition speed compared to the value expected in the bulk is found. This suggests the onset of velocity slippage at the silica walls or a reduced shear viscosity due to the transition towards a polymer-like flow in confined geometries. Both, light scattering and neutron imaging indicate a pronounced roughening of the imbibition fronts. Their overall shape and width can be resolved by neutron imaging. The fronts can be described by a superposition of independent wetting fronts moving with pore size-dependent square-root-of-time laws and weighted according to the pore size distributions obtained from nitrogen gas sorption isotherms. This finding indicates that the shape of the imbibition front in a porous medium, such as Vycor glass, with interconnected, elongated pores, is solely determined by independent movements of liquid menisci. These are dictated by the Laplace pressure and hydraulic permeability variations and thus the pore size variation at the invasion front. Our results suggest that pore size distributions can be derived from the broadening of imbibition fronts.
△ Less
Submitted 27 November, 2015;
originally announced November 2015.
-
High Dynamic Range Pixel Array Detector for Scanning Transmission Electron Microscopy
Authors:
Mark W. Tate,
Prafull Purohit,
Darol Chamberlain,
Kayla X. Nguyen,
Robert M. Hovden,
Celesta S. Chang,
Pratiti Deb,
Emrah Turgut,
John T. Heron,
Darrell G. Schlom,
Daniel C. Ralph,
Gregory D. Fuchs,
Katherine S. Shanks,
Hugh T. Philipp,
David A. Muller,
Sol M. Gruner
Abstract:
We describe a hybrid pixel array detector (EMPAD - electron microscope pixel array detector) adapted for use in electron microscope applications, especially as a universal detector for scanning transmission electron microscopy. The 128 x 128 pixel detector consists of a 500 um thick silicon diode array bump-bonded pixel-by-pixel to an application-specific integrated circuit (ASIC). The in-pixel ci…
▽ More
We describe a hybrid pixel array detector (EMPAD - electron microscope pixel array detector) adapted for use in electron microscope applications, especially as a universal detector for scanning transmission electron microscopy. The 128 x 128 pixel detector consists of a 500 um thick silicon diode array bump-bonded pixel-by-pixel to an application-specific integrated circuit (ASIC). The in-pixel circuitry provides a 1,000,000:1 dynamic range within a single frame, allowing the direct electron beam to be imaged while still maintaining single electron sensitivity. A 1.1 kHz framing rate enables rapid data collection and minimizes sample drift distortions while scanning. By capturing the entire unsaturated diffraction pattern in scanning mode, one can simultaneously capture bright field, dark field, and phase contrast information, as well as being able to analyze the full scattering distribution, allowing true center of mass imaging. The scattering is recorded on an absolute scale, so that information such as local sample thickness can be directly determined. This paper describes the detector architecture, data acquisition (DAQ) system, and preliminary results from experiments with 80 to 200 keV electron beams.
△ Less
Submitted 11 November, 2015;
originally announced November 2015.
-
Real-Space x-ray tomographic reconstruction of randomly oriented objects with sparse data frames
Authors:
Kartik Ayyer,
Hugh T. Philipp,
Mark W. Tate,
Veit Elser,
Sol M. Gruner
Abstract:
Schemes for X-ray imaging single protein molecules using new x-ray sources, like x-ray free electron lasers (XFELs), require processing many frames of data that are obtained by taking temporally short snapshots of identical molecules, each with a random and unknown orientation. Due to the small size of the molecules and short exposure times, average signal levels of much less than 1 photon/pixel/f…
▽ More
Schemes for X-ray imaging single protein molecules using new x-ray sources, like x-ray free electron lasers (XFELs), require processing many frames of data that are obtained by taking temporally short snapshots of identical molecules, each with a random and unknown orientation. Due to the small size of the molecules and short exposure times, average signal levels of much less than 1 photon/pixel/frame are expected, much too low to be processed using standard methods. One approach to process the data is to use statistical methods developed in the EMC algorithm (Loh & Elser, Phys. Rev. E, 2009) which processes the data set as a whole. In this paper we apply this method to a real-space tomographic reconstruction using sparse frames of data (below $10^{-2}$ photons/pixel/frame) obtained by performing x-ray transmission measurements of a low-contrast, randomly-oriented object. This extends the work by Philipp et al. (Optics Express, 2012) to three dimensions and is one step closer to the single molecule reconstruction problem.
△ Less
Submitted 7 November, 2013;
originally announced November 2013.
-
Anomalous Front Broadening During Spontaneous Imbibition in a Matrix with Elongated Pores
Authors:
Simon Gruener,
Zeinab Sadjadi,
Helen E. Hermes,
Andrij V. Kityk,
Klaus Knorr,
Heiko Rieger,
Patrick Huber
Abstract:
During spontaneous imbibition a wetting liquid is drawn into a porous medium by capillary forces. In systems with comparable pore length and diameter, such as paper and sand, the front of the propagating liquid forms a continuous interface. Sections of this interface advance in a highly correlated manner due to an effective surface tension, which restricts front broadening. Here we investigate wat…
▽ More
During spontaneous imbibition a wetting liquid is drawn into a porous medium by capillary forces. In systems with comparable pore length and diameter, such as paper and sand, the front of the propagating liquid forms a continuous interface. Sections of this interface advance in a highly correlated manner due to an effective surface tension, which restricts front broadening. Here we investigate water imbibition in a nanoporous glass (Vycor) in which the pores are much longer than they are wide. In this case, no continuous liquid-vapor interface with coalesced menisci can form. Anomalously fast imbibition front roughening is experimentally observed by neutron imaging.We propose a theoretical pore network model, whose structural details are adapted to the microscopic pore structure of Vycor glass, and show that it displays the same large scale roughening characteristics as observed in the experiment. The model predicts that menisci movements are uncorrelated. This indicates that despite the connectivity of the network the smoothening effect of surface tension on the imbibition front roughening is negligible. These results suggest a new universality class of imbibition behavior which is expected to occur in any matrix with elongated, interconnected pores of random radii.
△ Less
Submitted 8 July, 2012;
originally announced July 2012.
-
Solving Structure with Sparse, Randomly-Oriented X-ray Data
Authors:
Hugh T. Philipp,
Kartik Ayyer,
Mark W. Tate,
Veit Elser,
Sol M. Gruner
Abstract:
Single-particle imaging experiments of biomolecules at x-ray free-electron lasers (XFELs) require processing of hundreds of thousands (or more) of images that contain very few x-rays. Each low-flux image of the diffraction pattern is produced by a single, randomly oriented particle, such as a protein. We demonstrate the feasibility of collecting data at these extremes, averaging only 2.5 photons p…
▽ More
Single-particle imaging experiments of biomolecules at x-ray free-electron lasers (XFELs) require processing of hundreds of thousands (or more) of images that contain very few x-rays. Each low-flux image of the diffraction pattern is produced by a single, randomly oriented particle, such as a protein. We demonstrate the feasibility of collecting data at these extremes, averaging only 2.5 photons per frame, where it seems doubtful there could be information about the state of rotation, let alone the image contrast. This is accomplished with an expectation maximization algorithm that processes the low-flux data in aggregate, and without any prior knowledge of the object or its orientation. The versatility of the method promises, more generally, to redefine what measurement scenarios can provide useful signal in the high-noise regime.
△ Less
Submitted 15 March, 2012;
originally announced March 2012.
-
Concurrent Development of Model and Implementation
Authors:
A. Gravell,
Y. Howard,
J. C. Augusto,
C. Ferreira,
S. Gruner
Abstract:
This paper considers how a formal mathematically-based model can be used in support of evolutionary software development, and in particular how such a model can be kept consistent with the implementation as it changes to meet new requirements. A number of techniques are listed can make use of such a model to enhance the development process, and also ways to keep model and implementation consistent…
▽ More
This paper considers how a formal mathematically-based model can be used in support of evolutionary software development, and in particular how such a model can be kept consistent with the implementation as it changes to meet new requirements. A number of techniques are listed can make use of such a model to enhance the development process, and also ways to keep model and implementation consistent. The effectiveness of these techniques is investigated through two case studies concerning the development of small e-business applications, a travel agent and a mortgage broker. Some successes are reported, notably in the use of rapid throwaway modelling to investigate design alternatives, and also in the use of close team working and modelbased trace-checking to maintain synchronisation between model and implementation throughout the development. The main areas of weakness were seen to derive from deficiencies in tool support. Recommendations are therefore made for future improvements to tools supporting formal models which would, in principle, make this co-evolutionary approach attractive to industrial software developers. It is claimed that in fact tools already exist that provide the desired facilities, but these are not necessarily production-quality, and do not all support the same notations, and hence cannot be used together.
△ Less
Submitted 11 November, 2011;
originally announced November 2011.
-
Model-Based Trace-Checking
Authors:
Y. Howard,
S. Gruner,
A. Gravell,
C. Ferreira,
J. C. Augusto
Abstract:
Trace analysis can be a useful way to discover problems in a program under test. Rather than writing a special purpose trace analysis tool, this paper proposes that traces can usefully be analysed by checking them against a formal model using a standard model-checker or else an animator for executable specifications. These techniques are illustrated using a Travel Agent case study implemented in J…
▽ More
Trace analysis can be a useful way to discover problems in a program under test. Rather than writing a special purpose trace analysis tool, this paper proposes that traces can usefully be analysed by checking them against a formal model using a standard model-checker or else an animator for executable specifications. These techniques are illustrated using a Travel Agent case study implemented in J2EE. We added trace beans to this code that write trace information to a database. The traces are then extracted and converted into a form suitable for analysis by Spin, a popular model-checker, and Pro-B, a model-checker and animator for the B notation. This illustrates the technique, and also the fact that such a system can have a variety of models, in different notations, that capture different features. These experiments have demonstrated that model-based trace-checking is feasible. Future work is focussed on scaling up the approach to larger systems by increasing the level of automation.
△ Less
Submitted 11 November, 2011;
originally announced November 2011.
-
Connectivity Games over Dynamic Networks
Authors:
Sten Grüner,
Frank G. Radmacher,
Wolfgang Thomas
Abstract:
A game-theoretic model for the study of dynamic networks is analyzed. The model is motivated by communication networks that are subject to failure of nodes and where the restoration needs resources. The corresponding two-player game is played between "Destructor" (who can delete nodes) and "Constructor" (who can restore or even create nodes under certain conditions). We also include the feature of…
▽ More
A game-theoretic model for the study of dynamic networks is analyzed. The model is motivated by communication networks that are subject to failure of nodes and where the restoration needs resources. The corresponding two-player game is played between "Destructor" (who can delete nodes) and "Constructor" (who can restore or even create nodes under certain conditions). We also include the feature of information flow by allowing Constructor to change labels of adjacent nodes. As objective for Constructor the network property to be connected is considered, either as a safety condition or as a reachability condition (in the latter case starting from a non-connected network). We show under which conditions the solvability of the corresponding games for Constructor is decidable, and in this case obtain upper and lower complexity bounds, as well as algorithms derived from winning strategies. Due to the asymmetry between the players, safety and reachability objectives are not dual to each other and are treated separately.
△ Less
Submitted 6 June, 2011;
originally announced June 2011.
-
Imbibition in mesoporous silica: rheological concepts and experiments on water and a liquid crystal
Authors:
Simon Gruener,
Patrick Huber
Abstract:
We present, along with some fundamental concepts regarding imbibition of liquids in porous hosts, an experimental, gravimetric study on the capillarity-driven invasion dynamics of water and of the rod-like liquid crystal octyloxycyanobiphenyl (8OCB) in networks of pores a few nanometers across in monolithic silica glass (Vycor). We observe, in agreement with theoretical predictions, square root of…
▽ More
We present, along with some fundamental concepts regarding imbibition of liquids in porous hosts, an experimental, gravimetric study on the capillarity-driven invasion dynamics of water and of the rod-like liquid crystal octyloxycyanobiphenyl (8OCB) in networks of pores a few nanometers across in monolithic silica glass (Vycor). We observe, in agreement with theoretical predictions, square root of time invasion dynamics and a sticky velocity boundary condition for both liquids investigated. Temperature-dependent spontaneous imbibition experiments on 8OCB reveal the existence of a paranematic phase due to the molecular alignment induced by the pore walls even at temperatures well beyond the clearing point. The ever present velocity gradient in the pores is likely to further enhance this ordering phenomenon and prevent any layering in molecular stacks, eventually resulting in a suppression of the smectic phase in favor of the nematic phase.
△ Less
Submitted 12 May, 2011;
originally announced May 2011.
-
X-ray analog pixel array detector for single synchrotron bunch time-resolved imaging
Authors:
Lucas J. Koerner,
Sol M. Gruner
Abstract:
Dynamic x-ray studies may reach temporal resolutions limited by only the x-ray pulse duration if the detector is fast enough to segregate synchrotron pulses. An analog integrating pixel array detector with in-pixel storage and temporal resolution of around 150 ns, sufficient to isolate pulses, is presented. Analog integration minimizes count-rate limitations and in-pixel storage captures successiv…
▽ More
Dynamic x-ray studies may reach temporal resolutions limited by only the x-ray pulse duration if the detector is fast enough to segregate synchrotron pulses. An analog integrating pixel array detector with in-pixel storage and temporal resolution of around 150 ns, sufficient to isolate pulses, is presented. Analog integration minimizes count-rate limitations and in-pixel storage captures successive pulses. Fundamental tests of noise and linearity as well as high-speed laser measurements are shown. The detector resolved individual bunch trains at the Cornell High Energy Synchrotron Source (CHESS) at levels of up to 3.7x10^3 x-rays/pixel/train. When applied to turn-by-turn x-ray beam characterization single-shot intensity measurements were made with a repeatability of 0.4% and horizontal oscillations of the positron cloud were detected. This device is appropriate for time-resolved Bragg spot single crystal experiments.
△ Less
Submitted 26 July, 2010;
originally announced July 2010.
-
Capillary Rise and Imbibition of Liquids in Nanoporous Matrices: Rheological Concepts and Experiments
Authors:
Simon Gruener,
Patrick Huber
Abstract:
Liquid flow propelled by capillary forces is one of the most important transport mechanisms in porous environments. It is governed by a fascinating interplay of interfacial, viscous drag as well as gravitational forces which liquids encounter upon invasion into geometries with often complex topologies, such as capillary networks of trees or interconnected fractures in soils and ice. Here, we prese…
▽ More
Liquid flow propelled by capillary forces is one of the most important transport mechanisms in porous environments. It is governed by a fascinating interplay of interfacial, viscous drag as well as gravitational forces which liquids encounter upon invasion into geometries with often complex topologies, such as capillary networks of trees or interconnected fractures in soils and ice. Here, we present fundamentals, concepts and an experimental, gravimetric study on the capillarity-driven invasion dynamics of liquids in networks of pores a few nanometers across in monolithic, nanoporous silica glass (porous Vycor). A variation of the complexity of the building blocks of the liquids investigated along with a variation of the humidity and the temperature upon spontaneous imbibition allows us to gain information regarding the fluidity and capillarity of liquids in such nanoporous environments. We observe square-root of time imbibition dynamics for all liquids applied, which we can quantitatively describe by both a conserved bulk fluidity in the pore center and bulk capillarity at the advancing menisci, if we assume a sticky boundary layer (negative velocity slip length). Moreover, pecularities of nanopore-confined liquids, such as transport via the vapor phase leading to preadsorbed liquid layers, have to be properly accounted for. Upon increasing the chain-length in the case of the n-alkanes, we found hints towards a transition from stick- to slip-flow at the pore walls with increasing chain-length and thus polymeric behavior. Meniscus freezing is reported for n-tetracosane confined in porous Vycor. For the rheology of a rod-like liquid nematogen (8OCB) we found no hints of the viscosity drop upon entering into the nematic phase, typical of the bulk rheology of this liquid crystal.
△ Less
Submitted 5 May, 2010;
originally announced May 2010.
-
Spontaneous Imbibition Dynamics of an n-Alkane in Nanopores: Evidence of Meniscus Freezing and Monolayer Sticking
Authors:
Simon Gruener,
Patrick Huber
Abstract:
Capillary filling dynamics of liquid n-tetracosane (n-C24H50) in a network of cylindrical pores with 7 and 10 nm mean diameter in monolithic silica glass (Vycor) exhibit an abrupt temperature-slope change at Ts=54 deg C, ~4 deg C above bulk and ~16 deg C, 8 deg C, respectively, above pore freezing. It can be traced to a sudden inversion of the surface tension's T slope, and thus to a decrease in…
▽ More
Capillary filling dynamics of liquid n-tetracosane (n-C24H50) in a network of cylindrical pores with 7 and 10 nm mean diameter in monolithic silica glass (Vycor) exhibit an abrupt temperature-slope change at Ts=54 deg C, ~4 deg C above bulk and ~16 deg C, 8 deg C, respectively, above pore freezing. It can be traced to a sudden inversion of the surface tension's T slope, and thus to a decrease in surface entropy at the advancing pore menisci, characteristic of the formation of a single solid monolayer of rectified molecules, known as surface freezing from macroscopic, quiescent tetracosane melts. The imbibition speeds, that are the squared prefactors of the observed square-root-of-time Lucas-Washburn invasion kinetics, indicate a conserved bulk fluidity and capillarity of the nanopore-confined liquid, if we assume a flat lying, sticky hydrocarbon backbone monolayer at the silica walls.
△ Less
Submitted 22 October, 2009;
originally announced October 2009.
-
Capillary rise of water in hydrophilic nanopores
Authors:
Simon Gruener,
Tommy Hofmann,
Dirk Wallacher,
Andriy V. Kityk,
Patrick Huber
Abstract:
We report on the capillary rise of water in three-dimensional networks of hydrophilic silica pores with 3.5nm and 5nm mean radii, respectively (porous Vycor monoliths). We find classical square root of time Lucas-Washburn laws for the imbibition dynamics over the entire capillary rise times of up to 16h investigated. Provided we assume two preadsorbed strongly bound layers of water molecules res…
▽ More
We report on the capillary rise of water in three-dimensional networks of hydrophilic silica pores with 3.5nm and 5nm mean radii, respectively (porous Vycor monoliths). We find classical square root of time Lucas-Washburn laws for the imbibition dynamics over the entire capillary rise times of up to 16h investigated. Provided we assume two preadsorbed strongly bound layers of water molecules resting at the silica walls, which corresponds to a negative velocity slip length of -0.5nm for water flow in silica nanopores, we can describe the filling process by a retained fluidity and capillarity of water in the pore center. This anticipated partitioning in two dynamic components reflects the structural-thermodynamic partitioning in strongly silica bound water layers and capillary condensed water in the pore center which is documented by sorption isotherm measurements.
△ Less
Submitted 25 June, 2009;
originally announced June 2009.
-
Knudsen Diffusion in Silicon Nanochannels
Authors:
Simon Gruener,
Patrick Huber
Abstract:
Measurements on helium and argon gas flow through an array of parallel, linear channels of 12 nm diameter and 200 micrometer length in a single crystalline silicon membrane reveal a Knudsen diffusion type transport from 10^2 to 10^7 in Knudsen number Kn. The classic scaling prediction for the transport diffusion coefficient on temperature and mass of diffusing species,D_He ~ sqrt(T), is confirme…
▽ More
Measurements on helium and argon gas flow through an array of parallel, linear channels of 12 nm diameter and 200 micrometer length in a single crystalline silicon membrane reveal a Knudsen diffusion type transport from 10^2 to 10^7 in Knudsen number Kn. The classic scaling prediction for the transport diffusion coefficient on temperature and mass of diffusing species,D_He ~ sqrt(T), is confirmed over a T range from 40 K to 300 K for He and for the ratio of D_He/D_Ar ~ sqrt(m_Ar/m_He). Deviations of the channels from a cylindrical form, resolved with transmission electron microscopy down to subnanometer scales, quantitatively account for a reduced diffusivity as compared to Knudsen diffusion in ideal tubular channels. The membrane permeation experiments are described over 10 orders of magnitude in Kn, encompassing the transition flow regime, by the unified flow model of Beskok and Karniadakis.
△ Less
Submitted 13 February, 2008;
originally announced February 2008.
-
Imaging density disturbances in water with 41.3 attosecond time resolution
Authors:
P. Abbamonte,
K. D. Finkelstein,
M. D. Collins,
S. M. Gruner
Abstract:
We show that the momentum flexibility of inelastic x-ray scattering may be exploited to invert its loss function, alowing real time imaging of density disturbances in a medium. We show the disturbance arising from a point source in liquid water, with a resolution of 41.3 attoseconds ($4.13 \times 10^{-17}$ sec) and 1.27 $Å$ ($1.27 \times 10^{-8}$ cm). This result is used to determine the structu…
▽ More
We show that the momentum flexibility of inelastic x-ray scattering may be exploited to invert its loss function, alowing real time imaging of density disturbances in a medium. We show the disturbance arising from a point source in liquid water, with a resolution of 41.3 attoseconds ($4.13 \times 10^{-17}$ sec) and 1.27 $Å$ ($1.27 \times 10^{-8}$ cm). This result is used to determine the structure of the electron cloud around a photoexcited molecule in solution, as well as the wake generated in water by a 9 MeV gold ion. We draw an analogy with pump-probe techniques and suggest that energy-loss scattering may be applied more generally to the study of attosecond phenomena.
△ Less
Submitted 17 November, 2003;
originally announced November 2003.
-
Pressure Induced Hydration Dynamics of Membranes
Authors:
F. Osterberg,
M. Kriechbaum,
A. Polcyn,
V. Skita,
M. W. Tate,
P. T. C. So,
S. M. Gruner,
Shyamsunder Erramilli
Abstract:
Pressure-jump initiated time-resolved x-ray diffraction studies of dynamics of the hydration of the hexagonal phase in biological membranes show that (i) the relaxation of the unit cell spacing is non-exponential in time; (ii) the Bragg peaks shift smoothly to their final positions without significant broadening or loss in crystalline order. This suggests that the hydration is not diffusion limi…
▽ More
Pressure-jump initiated time-resolved x-ray diffraction studies of dynamics of the hydration of the hexagonal phase in biological membranes show that (i) the relaxation of the unit cell spacing is non-exponential in time; (ii) the Bragg peaks shift smoothly to their final positions without significant broadening or loss in crystalline order. This suggests that the hydration is not diffusion limited but occurs via a rather homogeneous swelling of the whole lattice, described by power law kinetics with an exponent $ β= 1.3 \pm 0.2$.
△ Less
Submitted 28 October, 1993;
originally announced October 1993.
-
Pressure Induced Topological Phase Transitions in Membranes
Authors:
P. T. C. So,
Sol M. Gruner,
Shyamsunder Erramilli
Abstract:
Some highly unusual features of a lipid-water liquid crystal are revealed by high pressure x-ray diffraction, light scattering and dilatometric studies of the lamellar (bilayer $L_α$) to nonlamellar inverse hexagonal ($H_{II}$) phase transition. (i) The size of the unit cell of the $H_{II}$ phase increases with increasing pressure. (ii) The transition volume, $ΔV_{bh}$, decreases and appears to…
▽ More
Some highly unusual features of a lipid-water liquid crystal are revealed by high pressure x-ray diffraction, light scattering and dilatometric studies of the lamellar (bilayer $L_α$) to nonlamellar inverse hexagonal ($H_{II}$) phase transition. (i) The size of the unit cell of the $H_{II}$ phase increases with increasing pressure. (ii) The transition volume, $ΔV_{bh}$, decreases and appears to vanish as the pressure is increased. (iii) The intensity of scattered light increases as $ΔV_{bh}$ decreases. Data are presented which suggest that this increase is due to the formation of an intermediate cubic phase, as predicted by recent theoretical suggestions of the underlying universal phase sequence.
△ Less
Submitted 4 October, 1992;
originally announced October 1992.