-
Leveraging GANs for data scarcity of COVID-19: Beyond the hype
Authors:
Hazrat Ali,
Christer Gronlund,
Zubair Shah
Abstract:
Artificial Intelligence (AI)-based models can help in diagnosing COVID-19 from lung CT scans and X-ray images; however, these models require large amounts of data for training and validation. Many researchers studied Generative Adversarial Networks (GANs) for producing synthetic lung CT scans and X-Ray images to improve the performance of AI-based models. It is not well explored how good GAN-based…
▽ More
Artificial Intelligence (AI)-based models can help in diagnosing COVID-19 from lung CT scans and X-ray images; however, these models require large amounts of data for training and validation. Many researchers studied Generative Adversarial Networks (GANs) for producing synthetic lung CT scans and X-Ray images to improve the performance of AI-based models. It is not well explored how good GAN-based methods performed to generate reliable synthetic data. This work analyzes 43 published studies that reported GANs for synthetic data generation. Many of these studies suffered data bias, lack of reproducibility, and lack of feedback from the radiologists or other domain experts. A common issue in these studies is the unavailability of the source code, hindering reproducibility. The included studies reported rescaling of the input images to train the existing GANs architecture without providing clinical insights on how the rescaling was motivated. Finally, even though GAN-based methods have the potential for data augmentation and improving the training of AI-based models, these methods fall short in terms of their use in clinical practice. This paper highlights research hotspots in countering the data scarcity problem, identifies various issues as well as potentials, and provides recommendations to guide future research. These recommendations might be useful to improve acceptability for the GAN-based approaches for data augmentation as GANs for data augmentation are increasingly becoming popular in the AI and medical imaging research community.
△ Less
Submitted 7 April, 2023;
originally announced April 2023.
-
R2U++: A Multiscale Recurrent Residual U-Net with Dense Skip Connections for Medical Image Segmentation
Authors:
Mehreen Mubashar,
Hazrat Ali,
Christer Gronlund,
Shoaib Azmat
Abstract:
U-Net is a widely adopted neural network in the domain of medical image segmentation. Despite its quick embracement by the medical imaging community, its performance suffers on complicated datasets. The problem can be ascribed to its simple feature extracting blocks: encoder/decoder, and the semantic gap between encoder and decoder. Variants of U-Net (such as R2U-Net) have been proposed to address…
▽ More
U-Net is a widely adopted neural network in the domain of medical image segmentation. Despite its quick embracement by the medical imaging community, its performance suffers on complicated datasets. The problem can be ascribed to its simple feature extracting blocks: encoder/decoder, and the semantic gap between encoder and decoder. Variants of U-Net (such as R2U-Net) have been proposed to address the problem of simple feature extracting blocks by making the network deeper, but it does not deal with the semantic gap problem. On the other hand, another variant UNET++ deals with the semantic gap problem by introducing dense skip connections but has simple feature extraction blocks. To overcome these issues, we propose a new U-Net based medical image segmentation architecture R2U++. In the proposed architecture, the adapted changes from vanilla U-Net are: (1) the plain convolutional backbone is replaced by a deeper recurrent residual convolution block. The increased field of view with these blocks aids in extracting crucial features for segmentation which is proven by improvement in the overall performance of the network. (2) The semantic gap between encoder and decoder is reduced by dense skip pathways. These pathways accumulate features coming from multiple scales and apply concatenation accordingly. The modified architecture has embedded multi-depth models, and an ensemble of outputs taken from varying depths improves the performance on foreground objects appearing at various scales in the images. The performance of R2U++ is evaluated on four distinct medical imaging modalities: electron microscopy (EM), X-rays, fundus, and computed tomography (CT). The average gain achieved in IoU score is 1.5+-0.37% and in dice score is 0.9+-0.33% over UNET++, whereas, 4.21+-2.72 in IoU and 3.47+-1.89 in dice score over R2U-Net across different medical imaging segmentation datasets.
△ Less
Submitted 3 June, 2022;
originally announced June 2022.
-
A deep learning pipeline for identification of motor units in musculoskeletal ultrasound
Authors:
Hazrat Ali,
Johannes Umander,
Robin Rohlén,
Christer Grönlund
Abstract:
Ultrasound imaging provides information from a large part of the muscle. It has recently been shown that ultrafast ultrasound imaging can be used to record and analyze the mechanical response of individual MUs using blind source separation. In this work, we present an alternative method - a deep learning pipeline - to identify active MUs in ultrasound image sequences, including segmentation of the…
▽ More
Ultrasound imaging provides information from a large part of the muscle. It has recently been shown that ultrafast ultrasound imaging can be used to record and analyze the mechanical response of individual MUs using blind source separation. In this work, we present an alternative method - a deep learning pipeline - to identify active MUs in ultrasound image sequences, including segmentation of their territories and signal estimation of their mechanical responses (twitch train). We train and evaluate the model using simulated data mimicking the complex activation pattern of tens of activated MUs with overlap** territories and partially synchronized activation patterns. Using a slow fusion approach (based on 3D CNNs), we transform the spatiotemporal image sequence data to 2D representations and apply a deep neural network architecture for segmentation. Next, we employ a second deep neural network architecture for signal estimation. The results show that the proposed pipeline can effectively identify individual MUs, estimate their territories, and estimate their twitch train signal at low contraction forces. The framework can retain spatio-temporal consistencies and information of the mechanical response of MU activity even when the ultrasound image sequences are transformed into a 2D representation for compatibility with more traditional computer vision and image processing techniques. The proposed pipeline is potentially useful to identify simultaneously active MUs in whole muscles in ultrasound image sequences of voluntary skeletal muscle contractions at low force levels.
△ Less
Submitted 23 September, 2020;
originally announced October 2020.
-
Segmentation of Lungs in Chest X-Ray Image Using Generative Adversarial Networks
Authors:
Faizan Munawar,
Shoaib Azmat,
Talha Iqbal,
Christer Grönlund,
Hazrat Ali
Abstract:
Chest X-ray (CXR) is a low-cost medical imaging technique. It is a common procedure for the identification of many respiratory diseases compared to MRI, CT, and PET scans. This paper presents the use of generative adversarial networks (GAN) to perform the task of lung segmentation on a given CXR. GANs are popular to generate realistic data by learning the map** from one domain to another. In our…
▽ More
Chest X-ray (CXR) is a low-cost medical imaging technique. It is a common procedure for the identification of many respiratory diseases compared to MRI, CT, and PET scans. This paper presents the use of generative adversarial networks (GAN) to perform the task of lung segmentation on a given CXR. GANs are popular to generate realistic data by learning the map** from one domain to another. In our work, the generator of the GAN is trained to generate a segmented mask of a given input CXR. The discriminator distinguishes between a ground truth and the generated mask, and updates the generator through the adversarial loss measure. The objective is to generate masks for the input CXR, which are as realistic as possible compared to the ground truth masks. The model is trained and evaluated using four different discriminators referred to as D1, D2, D3, and D4, respectively. Experimental results on three different CXR datasets reveal that the proposed model is able to achieve a dice-score of 0.9740, and IOU score of 0.943, which are better than other reported state-of-the art results.
△ Less
Submitted 12 September, 2020;
originally announced September 2020.