-
2 inch Molecular Organic Glass Scintillator for Neutron-Gamma Discrimination
Authors:
Martyna Grodzicka-Kobylka,
Tomasz Szczesniak,
Marek Moszyński,
Lukasz Swiderski,
Kamil Brylew,
Patrick L. Feng,
Lucas Q. Nguyen,
Joey S. Carlson,
Jose J. Valiente-Dobón,
Jan Trzuskowski,
Agnieszka Misiarz,
Łukasz Talarek,
Paweł Zając
Abstract:
In this manuscript we report on the scintillation properties and pulse shape discrimination (PSD) performance of new organic glass scintillator. Two cylindrical samples with dimensions of 2x2 inches were tested. Additionally, this two samples were used in stack configuration in order to measure the PSD characteristics of a sample with a size of 2x4 inches. The study covers the measurements of neut…
▽ More
In this manuscript we report on the scintillation properties and pulse shape discrimination (PSD) performance of new organic glass scintillator. Two cylindrical samples with dimensions of 2x2 inches were tested. Additionally, this two samples were used in stack configuration in order to measure the PSD characteristics of a sample with a size of 2x4 inches. The study covers the measurements of neutron/gamma discrimination capability, emission spectra, photoelectron yield and analysis of the light pulse shapes originating from events related to gamma-rays and fast neutrons. The results were compared to data recorded previously using an EJ-276 plastic scintillator, an EJ-309 liquid scintillator and a stilbene single crystal.
△ Less
Submitted 17 January, 2023;
originally announced January 2023.
-
Status and initial physics performance studies of the MPD experiment at NICA
Authors:
MPD Collaboration,
V. Abgaryan,
R. Acevedo Kado,
S. V. Afanasyev,
G. N. Agakishiev,
E. Alpatov,
G. Altsybeev,
M. Alvarado Hernández,
S. V. Andreeva,
T. V. Andreeva,
E. V. Andronov,
N. V. Anfimov,
A. A. Aparin,
V. I. Astakhov,
E. Atkin,
T. Aushev,
G. S. Averichev,
A. V. Averyanov,
A. Ayala,
V. A. Babkin,
T. Babutsidze,
I. A. Balashov,
A. Bancer,
M. Yu. Barabanov,
D. A. Baranov
, et al. (454 additional authors not shown)
Abstract:
The Nuclotron-base Ion Collider fAcility (NICA) is under construction at the Joint Institute for Nuclear Research (JINR), with commissioning of the facility expected in late 2022. The Multi-Purpose Detector (MPD) has been designed to operate at NICA and its components are currently in production. The detector is expected to be ready for data taking with the first beams from NICA. This document pro…
▽ More
The Nuclotron-base Ion Collider fAcility (NICA) is under construction at the Joint Institute for Nuclear Research (JINR), with commissioning of the facility expected in late 2022. The Multi-Purpose Detector (MPD) has been designed to operate at NICA and its components are currently in production. The detector is expected to be ready for data taking with the first beams from NICA. This document provides an overview of the landscape of the investigation of the QCD phase diagram in the region of maximum baryonic density, where NICA and MPD will be able to provide significant and unique input. It also provides a detailed description of the MPD set-up, including its various subsystems as well as its support and computing infrastructures. Selected performance studies for particular physics measurements at MPD are presented and discussed in the context of existing data and theoretical expectations.
△ Less
Submitted 16 February, 2022;
originally announced February 2022.
-
SiPM proton irradiation for application in cosmic space
Authors:
S. Mianowski,
D. M. Borowicz,
K. Brylew,
A. Dziedzic,
M. Grodzicka-Kobylka,
A. Korgul,
M. Krakowiak,
Z. Mianowska,
A. G. Molokanov,
M. Moszynski,
G. V. Mytsin,
D. Rybka,
K. Shipulin,
T. Szczesniak
Abstract:
This paper presents the results of the proton irradiation of silicon photomulipliers (SiPMs) by mono-energetic 170 MeV protons with fluence up to 4.6$\times$10$^{9}$ particles/cm$^2$. In our work, three types of silicon photodetectors from Hamamatsu with areas 3$\times$3 mm$^2$ and different subpixel sizes of 25$\times$25 $μ$m$^2$, 50$\times$50 $μ$m$^2$, and 75$\times$75 $μ$m$^2$ were used. The ch…
▽ More
This paper presents the results of the proton irradiation of silicon photomulipliers (SiPMs) by mono-energetic 170 MeV protons with fluence up to 4.6$\times$10$^{9}$ particles/cm$^2$. In our work, three types of silicon photodetectors from Hamamatsu with areas 3$\times$3 mm$^2$ and different subpixel sizes of 25$\times$25 $μ$m$^2$, 50$\times$50 $μ$m$^2$, and 75$\times$75 $μ$m$^2$ were used. The changes in the SiPM dark count rate (DCR) spectrum before and after irradiation in temperatures in the range of 20 $^\circ$C to -65 $^\circ$C are presented. The influence of the DCR changes on the energy resolution of the 662 keV gamma line from the $^{137}$Cs for a non-irradiated GAGG:Ce (1$\%$) scintillator is investigated. The time period of usability of the SiPM detector irradiated by protons in cosmic space was estimated.
△ Less
Submitted 21 March, 2020;
originally announced March 2020.