The design and construction of the MICE Electron-Muon Ranger
Authors:
R. Asfandiyarov,
P. Bene,
A. Blondel,
D. Bolognini,
F. Cadoux,
S. Debieux,
F. Drielsma,
G. Giannini,
J. S. Graulich,
C. Husi,
Y. Karadzhov,
D. Lietti,
F. Masciocchi,
L. Nicola,
E. Noah Messomo,
M. Prest,
K. Rothenfusser,
R. Sandstrom,
E. Vallazza,
V. Verguilov,
H. Wisting
Abstract:
The Electron-Muon Ranger (EMR) is a fully-active tracking-calorimeter installed in the beam line of the Muon Ionization Cooling Experiment (MICE). The experiment will demonstrate ionization cooling, an essential technology needed for the realization of a Neutrino Factory and/or a Muon Collider. The EMR is designed to measure the properties of low energy beams composed of muons, electrons and pions…
▽ More
The Electron-Muon Ranger (EMR) is a fully-active tracking-calorimeter installed in the beam line of the Muon Ionization Cooling Experiment (MICE). The experiment will demonstrate ionization cooling, an essential technology needed for the realization of a Neutrino Factory and/or a Muon Collider. The EMR is designed to measure the properties of low energy beams composed of muons, electrons and pions, and perform the identification particle-by-particle. The detector consists of 48 orthogonal layers of 59 triangular scintillator bars. The readout is implemented using FPGA custom made electronics and commercially available modules. This article describes the construction of the detector from its design up to its commissioning with cosmic data.
△ Less
Submitted 18 July, 2016;
originally announced July 2016.
-
Electron-Muon Ranger: performance in the MICE Muon Beam
Authors:
D. Adams,
A. Alekou,
M. Apollonio,
R. Asfandiyarov,
G. Barber,
P. Barclay,
A. de Bari,
R. Bayes,
V. Bayliss,
P. Bene,
R. Bertoni,
V. J. Blackmore,
A. Blondel,
S. Blot,
M. Bogomilov,
M. Bonesini,
C. N. Booth,
D. Bowring,
S. Boyd,
T. W. Bradshaw,
U. Bravar,
A. D. Bross,
F. Cadoux,
M. Capponi,
T. Carlisle
, et al. (129 additional authors not shown)
Abstract:
The Muon Ionization Cooling Experiment (MICE) will perform a detailed study of ionization cooling to evaluate the feasibility of the technique. To carry out this program, MICE requires an efficient particle-identification (PID) system to identify muons. The Electron-Muon Ranger (EMR) is a fully-active tracking-calorimeter that forms part of the PID system and tags muons that traverse the cooling c…
▽ More
The Muon Ionization Cooling Experiment (MICE) will perform a detailed study of ionization cooling to evaluate the feasibility of the technique. To carry out this program, MICE requires an efficient particle-identification (PID) system to identify muons. The Electron-Muon Ranger (EMR) is a fully-active tracking-calorimeter that forms part of the PID system and tags muons that traverse the cooling channel without decaying. The detector is capable of identifying electrons with an efficiency of 98.6%, providing a purity for the MICE beam that exceeds 99.8%. The EMR also proved to be a powerful tool for the reconstruction of muon momenta in the range 100-280 MeV/$c$.
△ Less
Submitted 3 November, 2015; v1 submitted 28 October, 2015;
originally announced October 2015.
-
Characterisation of the muon beams for the Muon Ionisation Cooling Experiment
Authors:
The MICE Collaboration,
D. Adams,
D. Adey,
A. Alekou,
M. Apollonio,
R. Asfandiyarov,
J. Back,
G. Barber,
P. Barclay,
A. de Bari,
R. Bayes,
V. Bayliss,
R. Bertoni,
V. J. Blackmore,
A. Blondel,
S. Blot,
M. Bogomilov,
M. Bonesini,
C. N. Booth,
D. Bowring,
S. Boyd,
T. W. Bradshaw,
U. Bravar,
A. D. Bross,
M. Capponi
, et al. (119 additional authors not shown)
Abstract:
A novel single-particle technique to measure emittance has been developed and used to characterise seventeen different muon beams for the Muon Ionisation Cooling Experiment (MICE). The muon beams, whose mean momenta vary from 171 to 281 MeV/c, have emittances of approximately 1.5--2.3 πmm-rad horizontally and 0.6--1.0 πmm-rad vertically, a horizontal dispersion of 90--190 mm and momentum spreads o…
▽ More
A novel single-particle technique to measure emittance has been developed and used to characterise seventeen different muon beams for the Muon Ionisation Cooling Experiment (MICE). The muon beams, whose mean momenta vary from 171 to 281 MeV/c, have emittances of approximately 1.5--2.3 πmm-rad horizontally and 0.6--1.0 πmm-rad vertically, a horizontal dispersion of 90--190 mm and momentum spreads of about 25 MeV/c. There is reasonable agreement between the measured parameters of the beams and the results of simulations. The beams are found to meet the requirements of MICE.
△ Less
Submitted 11 October, 2013; v1 submitted 6 June, 2013;
originally announced June 2013.
-
MICE: the Muon Ionization Cooling Experiment. Step I: First Measurement of Emittance with Particle Physics Detectors
Authors:
U. Bravar,
M. Bogomilov,
Y. Karadzhov,
D. Kolev,
I. Russinov,
R. Tsenov,
L. Wang,
F. Y. Xu,
S. X. Zheng,
R. Bertoni,
M. Bonesini,
R. Mazza,
V. Palladino,
G. Cecchet,
A. de Bari,
M. Capponi,
A. Iaciofano,
D. Orestano,
F. Pastore,
L. Tortora,
S. Ishimoto,
S. Suzuki,
K. Yoshimura,
Y. Mori,
Y. Kuno
, et al. (123 additional authors not shown)
Abstract:
The Muon Ionization Cooling Experiment (MICE) is a strategic R&D project intended to demonstrate the only practical solution to providing high brilliance beams necessary for a neutrino factory or muon collider. MICE is under development at the Rutherford Appleton Laboratory (RAL) in the United Kingdom. It comprises a dedicated beamline to generate a range of input muon emittances and momenta, with…
▽ More
The Muon Ionization Cooling Experiment (MICE) is a strategic R&D project intended to demonstrate the only practical solution to providing high brilliance beams necessary for a neutrino factory or muon collider. MICE is under development at the Rutherford Appleton Laboratory (RAL) in the United Kingdom. It comprises a dedicated beamline to generate a range of input muon emittances and momenta, with time-of-flight and Cherenkov detectors to ensure a pure muon beam. The emittance of the incoming beam will be measured in the upstream magnetic spectrometer with a scintillating fiber tracker. A cooling cell will then follow, alternating energy loss in Liquid Hydrogen (LH2) absorbers to RF cavity acceleration. A second spectrometer, identical to the first, and a second muon identification system will measure the outgoing emittance. In the 2010 run at RAL the muon beamline and most detectors were fully commissioned and a first measurement of the emittance of the muon beam with particle physics (time-of-flight) detectors was performed. The analysis of these data was recently completed and is discussed in this paper. Future steps for MICE, where beam emittance and emittance reduction (cooling) are to be measured with greater accuracy, are also presented.
△ Less
Submitted 30 July, 2013; v1 submitted 9 October, 2011;
originally announced October 2011.
-
The design and commissioning of the MICE upstream time-of-flight system
Authors:
R. Bertoni,
A. Blondel,
M. Bonesini,
G. Cecchet,
A. de Bari,
J. S. Graulich,
Y. Kharadzov,
M. Rayner,
I. Rusinov,
R. Tsenov,
S. Terzo,
V. Verguilov
Abstract:
In the MICE experiment at RAL the upstream time-of-flight detectors are used for particle identification in the incoming muon beam, for the experiment trigger and for a precise timing (sigma_t ~ 50 ps) with respect to the accelerating RF cavities working at 201 MHz. The construction of the upstream section of the MICE time-of-flight system and the tests done to characterize its individual compon…
▽ More
In the MICE experiment at RAL the upstream time-of-flight detectors are used for particle identification in the incoming muon beam, for the experiment trigger and for a precise timing (sigma_t ~ 50 ps) with respect to the accelerating RF cavities working at 201 MHz. The construction of the upstream section of the MICE time-of-flight system and the tests done to characterize its individual components are shown. Detector timing resolutions ~50-60 ps were achieved. Test beam performance and preliminary results obtained with beam at RAL are reported.
△ Less
Submitted 3 March, 2010; v1 submitted 25 January, 2010;
originally announced January 2010.
-
Comparison of large-angle production of charged pions with incident protons on cylindrical long and short targets
Authors:
The HARP Collaboration,
M. Apollonio,
A. Artamonov,
A. Bagulya,
G. Barr,
A. Blondel,
F. Bobisut,
M. Bogomilov,
M. Bonesini,
C. Booth,
S. Borghi,
S. Bunyatov,
J. Burguet-Castell,
M. G. Catanesi,
A. Cervera-Villanueva,
P. Chimenti,
L. Coney,
E. Di Capua,
U. Dore,
J. Dumarchez,
R. Edgecock,
M. Ellis,
F. Ferri,
U. Gastaldi,
S. Giani
, et al. (49 additional authors not shown)
Abstract:
The HARP collaboration has presented measurements of the double-differential pi+/pi- production cross-section in the range of momentum 100 MeV/c <= p 800 MeV/c and angle 0.35 rad <= theta <= 2.15 rad with proton beams hitting thin nuclear targets. In many applications the extrapolation to long targets is necessary. In this paper the analysis of data taken with long (one interaction length) solid…
▽ More
The HARP collaboration has presented measurements of the double-differential pi+/pi- production cross-section in the range of momentum 100 MeV/c <= p 800 MeV/c and angle 0.35 rad <= theta <= 2.15 rad with proton beams hitting thin nuclear targets. In many applications the extrapolation to long targets is necessary. In this paper the analysis of data taken with long (one interaction length) solid cylindrical targets made of carbon, tantalum and lead is presented. The data were taken with the large acceptance HARP detector in the T9 beam line of the CERN PS. The secondary pions were produced by beams of protons with momenta 5 GeV/c, 8 GeV/c and 12 GeV/c. The tracking and identification of the produced particles were performed using a small-radius cylindrical time projection chamber (TPC) placed inside a solenoidal magnet. Incident protons were identified by an elaborate system of beam detectors. Results are obtained for the double-differential yields per target nucleon d2 sigma / dp dtheta. The measurements are compared with predictions of the MARS and GEANT4 Monte Carlo simulations.
△ Less
Submitted 23 December, 2009; v1 submitted 2 September, 2009;
originally announced September 2009.
-
Large-angle production of charged pions with incident pion beams on nuclear targets
Authors:
The HARP Collaboration,
M. Apollonio,
A. Artamonov,
A. Bagulya,
G. Barr,
A. Blondel,
F. Bobisut,
M. Bogomilov,
M. Bonesini,
C. Booth,
S. Borghi,
S. Bunyatov,
J. Burguet-Castell,
M. G. Catanesi,
A. Cervera-Villanueva,
P. Chimenti,
L. Coney,
E. Di Capua,
U. Dore,
J. Dumarchez,
R. Edgecock,
M. Ellis,
F. Ferri,
U. Gastaldi,
S. Giani
, et al. (49 additional authors not shown)
Abstract:
Measurements of the double-differential pi+/- production cross-section in the range of momentum 100 MeV/c <= p <= 800 MeV/c and angle 0.35 rad <= theta <= 2.15 rad using pi+/- beams incident on beryllium, aluminium, carbon, copper, tin, tantalum and lead targets are presented. The data were taken with the large acceptance HARP detector in the T9 beam line of the CERN Proton Synchrotron. The seco…
▽ More
Measurements of the double-differential pi+/- production cross-section in the range of momentum 100 MeV/c <= p <= 800 MeV/c and angle 0.35 rad <= theta <= 2.15 rad using pi+/- beams incident on beryllium, aluminium, carbon, copper, tin, tantalum and lead targets are presented. The data were taken with the large acceptance HARP detector in the T9 beam line of the CERN Proton Synchrotron. The secondary pions were produced by beams in a momentum range from 3 GeV/c to 12.9 GeV/c hitting a solid target with a thickness of 5% of a nuclear interaction length. The tracking and identification of the produced particles was performed using a small-radius cylindrical time projection chamber (TPC) placed inside a solenoidal magnet. Incident particles were identified by an elaborate system of beam detectors. Results are obtained for the double-differential cross-sections d2sigma/dpdtheta at six incident beam momenta. Data at 3 GeV/c, 5 GeV/c, 8 GeV/c, and 12 GeV/c are available for all targets while additional data at 8.9 GeV/c and 12.9 GeV/c were taken in positive particle beams on Be and Al targets, respectively. The measurements are compared with several generators of GEANT4 and the MARS Monte Carlo simulation.
△ Less
Submitted 1 January, 2010; v1 submitted 9 July, 2009;
originally announced July 2009.
-
The Time Response of Glass Resistive Plate Chambers to Heavily Ionizing Particles
Authors:
A. Artamonov,
A. Blondel,
M. Bogomilov,
C. Booth,
S. Borghi,
M. G. Catanesi,
A. Cervera--Villanueva,
P. Chimenti,
U. Gastaldi,
S. Giani,
J. J. Gómez--Cadenas,
J. S. Graulich,
G. Grégoire,
A. Grossheim,
A. Guglielmi,
V. Ivanchenko,
D. Kolev,
C. Meurer,
M. Mezzetto,
J. Panman,
B. Popov,
E. Radicioni,
R. Schroeter,
P. Temnikov,
E. Tcherniaev
, et al. (3 additional authors not shown)
Abstract:
The HARP system of resistive plate chambers (RPCs) was designed to perform particle identification by the measurement of the difference in the time-of-flight of different particles. In previous papers an apparent discrepancy was shown between the response of the RPCs to minimum ionizing pions and heavily ionizing protons. Using the kinematics of elastic scattering off a hydrogen target a control…
▽ More
The HARP system of resistive plate chambers (RPCs) was designed to perform particle identification by the measurement of the difference in the time-of-flight of different particles. In previous papers an apparent discrepancy was shown between the response of the RPCs to minimum ionizing pions and heavily ionizing protons. Using the kinematics of elastic scattering off a hydrogen target a controlled beam of low momentum recoil protons was directed onto the chambers. With this method the trajectory and momentum, and hence the time-of-flight of the protons can be precisely predicted without need for a measurement of momentum of the protons. It is demonstrated that the measurement of the time-of-arrival of particles by the thin gas-gap glass RPC system of the HARP experiment depends on the primary ionization deposited by the particle in the detector.
△ Less
Submitted 28 September, 2007; v1 submitted 24 September, 2007;
originally announced September 2007.