-
Optimization of an Optical Testbed for Characterization of EXCLAIM u-Spec Integrated Spectrometers
Authors:
Maryam Rahmani,
Emily M. Barrentine,
Eric R. Switzer,
Alyssa Barlis,
Ari D. Brown,
Giuseppe Cataldo,
Jake A. Connors,
Negar Ehsan,
Thomas M. Essinger-Hileman,
Henry Grant,
James Hays-Wehle,
Wen-Ting Hsieh,
Vilem Mikula,
S. Harvey Moseley,
Omid Noroozian,
Manuel A. Quijada,
Jessica Patel,
Thomas R. Stevenson,
Carole Tucker,
Kongpop U-Yen,
Carolyn G. Volpert,
Edward J. Wollack
Abstract:
We describe a testbed to characterize the optical response of compact superconducting on-chip spectrometers in development for the Experiment for Cryogenic Large-Aperture Intensity Map** (EXCLAIM) mission. EXCLAIM is a balloonborne far-infrared experiment to probe the CO and CII emission lines in galaxies from redshift 3.5 to the present. The spectrometer, called u-Spec, comprises a diffraction…
▽ More
We describe a testbed to characterize the optical response of compact superconducting on-chip spectrometers in development for the Experiment for Cryogenic Large-Aperture Intensity Map** (EXCLAIM) mission. EXCLAIM is a balloonborne far-infrared experiment to probe the CO and CII emission lines in galaxies from redshift 3.5 to the present. The spectrometer, called u-Spec, comprises a diffraction grating on a silicon chip coupled to kinetic inductance detectors (KIDs) read out via a single microwave feedline. We use a prototype spectrometer for EXCLAIM to demonstrate our ability to characterize the spectrometers spectral response using a photomixer source. We utilize an on-chip reference detector to normalize relative to spectral structure from the off-chip optics and a silicon etalon to calibrate the absolute frequency.
△ Less
Submitted 12 December, 2023;
originally announced December 2023.
-
Integrated Electro-Optic Isolator on Thin Film Lithium Niobate
Authors:
Mengjie Yu,
Rebecca Cheng,
Christian Reimer,
Lingyan He,
Kevin Luke,
Eric Puma,
Linbo Shao,
Amirhassan Shams-Ansari,
Hannah R. Grant,
Leif Johansson,
Mian Zhang,
Marko Lončar
Abstract:
Optical isolator is an indispensable component of almost any optical system and is used to protect a laser from unwanted reflections for phase-stable coherent operation. The development of chip-scale optical systems, powered by semiconductor lasers integrated on the same chip, has resulted in a need for a fully integrated optical isolator. However, conventional approaches based on application of m…
▽ More
Optical isolator is an indispensable component of almost any optical system and is used to protect a laser from unwanted reflections for phase-stable coherent operation. The development of chip-scale optical systems, powered by semiconductor lasers integrated on the same chip, has resulted in a need for a fully integrated optical isolator. However, conventional approaches based on application of magneto-optic materials to break the reciprocity and provide required isolation have significant challenges in terms of material processing and insertion loss. As a result, many magnetic-free approaches have been explored, including acousto-optics, optical nonlinearity, and electro-optics. However, to date, the realization of an integrated isolator with low insertion loss, high isolation ratio, broad bandwidth, and low power consumption on a monolithic material platform is still absent. Here we realize non-reciprocal traveling-wave EO-based isolator on thin-film LN, enabling maximum optical isolation of 48 dB and an on-chip insertion loss of 0.5 dB using a single-frequency microwave drive at 21-dBm RF power. The isolation ratio is verified to be larger than 37 dB across a tunable optical wavelength range from 1510 to 1630 nm. We verify that our hybrid DFB laser - LN isolator module successfully protects the single-mode operation and the linewidth of the DFB laser from reflection. Our result is a significant step towards a practical high-performance optical isolator on chip.
△ Less
Submitted 4 December, 2022;
originally announced December 2022.
-
An Advantage Using Feature Selection with a Quantum Annealer
Authors:
Andrew Vlasic,
Hunter Grant,
Salvatore Certo
Abstract:
Feature selection is a technique in statistical prediction modeling that identifies features in a record with a strong statistical connection to the target variable. Excluding features with a weak statistical connection to the target variable in training not only drops the dimension of the data, which decreases the time complexity of the algorithm, it also decreases noise within the data which ass…
▽ More
Feature selection is a technique in statistical prediction modeling that identifies features in a record with a strong statistical connection to the target variable. Excluding features with a weak statistical connection to the target variable in training not only drops the dimension of the data, which decreases the time complexity of the algorithm, it also decreases noise within the data which assists in avoiding overfitting. In all, feature selection assists in training a robust statistical model that performs well and is stable. Given the lack of scalability in classical computation, current techniques only consider the predictive power of the feature and not redundancy between the features themselves. Recent advancements in feature selection that leverages quantum annealing (QA) gives a scalable technique that aims to maximize the predictive power of the features while minimizing redundancy. As a consequence, it is expected that this algorithm would assist in the bias/variance trade-off yielding better features for training a statistical model. This paper tests this intuition against classical methods by utilizing open-source data sets and evaluate the efficacy of each trained statistical model well-known prediction algorithms. The numerical results display an advantage utilizing the features selected from the algorithm that leveraged QA.
△ Less
Submitted 1 June, 2023; v1 submitted 17 November, 2022;
originally announced November 2022.
-
Dynamics of the no-slip Galton board
Authors:
Jan Ahmed,
Timothy Chumley,
Scott Cook,
Christopher Cox,
Hakiem Grant,
Nicholas Petela,
Bethany Rothrock,
Ridnald Xhafaj
Abstract:
The ideal Galton board and Lorentz gas billiard models have been studied numerically and analytically primarily in settings where friction and rotational velocity are neglected. We eliminate these simplifying assumptions and study the resulting dynamics of a more general model using no-slip collisions, in which particles rotate and may exchange linear and angular momentum at collisions while adher…
▽ More
The ideal Galton board and Lorentz gas billiard models have been studied numerically and analytically primarily in settings where friction and rotational velocity are neglected. We eliminate these simplifying assumptions and study the resulting dynamics of a more general model using no-slip collisions, in which particles rotate and may exchange linear and angular momentum at collisions while adhering to certain conservation laws. Using numerical experiments and phase portrait analysis we show that (in contrast to specular dispersing billiards) regularity persists when a small force is introduced while (consistent with specular billiards) under a stronger force new structure including invariant regions may arise. We also show analytically that with the introduction of an external force periodicity proliferates, with new types of periodic orbits not present in the no-force case.
△ Less
Submitted 16 August, 2022;
originally announced August 2022.
-
Optical Characterization & Testbed Development for μ-Spec Integrated Spectrometers
Authors:
Maryam Rahmani,
Alyssa Barlis,
Emily M. Barrentine,
Ari D. Brown,
Berhanu T. Bulcha,
Giuseppe Cataldo,
Jake Connors,
Negar Ehsan,
Thomas M. Essinger-Hileman,
Henry Grant,
James Hays-Wehle,
Wen-Ting Hsieh,
Vilem Mikula,
S. Harvey Moseley,
Omid Noroozian,
Trevor R. Oxholm,
Manuel A. Quijada,
Jessica Patel,
Thomas R. Stevenson,
Eric R. Switzer,
Carole Tucker,
Kongpop U-Yen,
Carolyn Volpert,
Edward J. Wollack
Abstract:
This paper describes a cryogenic optical testbed developed to characterize u-Spec spectrometers in a dedicated dilution refrigerator (DR) system. u-Spec is a far-infrared integrated spectrometer that is an analog to a Rowland-type grating spectrometer. It employs a single-crystal silicon substrate with niobium microstrip lines and aluminum kinetic inductance detectors (KIDs). Current designs with…
▽ More
This paper describes a cryogenic optical testbed developed to characterize u-Spec spectrometers in a dedicated dilution refrigerator (DR) system. u-Spec is a far-infrared integrated spectrometer that is an analog to a Rowland-type grating spectrometer. It employs a single-crystal silicon substrate with niobium microstrip lines and aluminum kinetic inductance detectors (KIDs). Current designs with a resolution of 512 are in fabrication for the EXCLAIM (Experiment for Cryogenic Large Aperture Intensity Map**) balloon mission. The primary spectrometer performance and design parameters are efficiency, NEP, inter-channel isolation, spectral resolution, and frequency response for each channel. Here we present the development and design of an optical characterization facility and preliminary validation of that facility with earlier prototype R=64 devices. We have conducted and describe initial optical measurements of R = 64 devices using a swept photomixer line source. We also discuss the test plan for optical characterization of the EXCLAIM R = 512 u-Spec devices in this new testbed.
△ Less
Submitted 12 August, 2022;
originally announced August 2022.
-
Femtosecond Pulse Generation via an Integrated Electro-Optic Time Lens
Authors:
Mengjie Yu,
Christian Reimer,
David Barton,
Prashanta Kharel,
Rebecca Cheng,
Lingyan He,
Linbo Shao,
Di Zhu,
Yaowen Hu,
Hannah R. Grant,
Leif Johansson,
Yoshitomo Okawachi,
Alexander L. Gaeta,
Mian Zhang,
Marko Lončar
Abstract:
Integrated femtosecond pulse and frequency comb sources are critical components for a wide range of applications. The leading approaches for on-chip pulse generation rely on mode locking inside microresonator with either third-order nonlinearity or with semiconductor gain. These approaches, however, are limited in noise performance, wavelength tunability and repetition rates. Alternatively, sub-pi…
▽ More
Integrated femtosecond pulse and frequency comb sources are critical components for a wide range of applications. The leading approaches for on-chip pulse generation rely on mode locking inside microresonator with either third-order nonlinearity or with semiconductor gain. These approaches, however, are limited in noise performance, wavelength tunability and repetition rates. Alternatively, sub-picosecond pulses can be synthesized without mode-locking, by modulating a continuous-wave (CW) single-frequency laser using a cascade of electro-optic (EO) modulators. This method is particularly attractive due to its simplicity, robustness, and frequency-agility but has been realized only on a tabletop using multiple discrete EO modulators and requiring optical amplifiers (to overcome large insertion losses), microwave amplifiers, and phase shifters. Here we demonstrate a chip-scale femtosecond pulse source implemented on an integrated lithium niobate (LN) photonic platform18, using cascaded low-loss electro-optic amplitude and phase modulators and chirped Bragg grating, forming a time-lens system. The device is driven by a CW distributed feedback (DFB) chip laser and controlled by a single CW microwave source without the need for any stabilization or locking. We measure femtosecond pulse trains (520 fs duration) with a 30-GHz repetition rate, flat-top optical spectra with a 10-dB optical bandwidth of 12.6 nm, individual comb-line powers above 0.1 milliwatt, and pulse energies of 0.54 picojoule. Our results represent a tunable, robust and low-cost integrated pulsed light source with CW-to-pulse conversion efficiencies an order of magnitude higher than achieved with previous integrated sources. Our pulse generator can find applications from ultrafast optical measurement to networks of distributed quantum computers.
△ Less
Submitted 16 December, 2021;
originally announced December 2021.
-
Electrically-pumped high-power laser transmitter integrated on thin-film lithium niobate
Authors:
Amirhassan Shams-Ansari,
Dylan Renaud,
Rebecca Cheng,
Linbo Shao,
Lingyan He,
Di Zhu,
Mengjie Yu,
Hannah R. Grant,
Leif Johansson,
Mian Zhang,
Marko Loncar
Abstract:
Integrated thin-film lithium niobate (TFLN) photonics has emerged as a promising platform for realization of high-performance chip-scale optical systems. Of particular importance are TFLN electro-optic modulators featuring high-linearity, low driving voltage and lowpropagation loss. However, fully integrated system requires integration of high power, low noise, and narrow linewidth lasers on TFLN…
▽ More
Integrated thin-film lithium niobate (TFLN) photonics has emerged as a promising platform for realization of high-performance chip-scale optical systems. Of particular importance are TFLN electro-optic modulators featuring high-linearity, low driving voltage and lowpropagation loss. However, fully integrated system requires integration of high power, low noise, and narrow linewidth lasers on TFLN chip. Here we achieve this goal, and demonstrate integrated high-power lasers on TFLN platform with up to 60 mW of optical power in the waveguides. We use this platform to realize a highpower transmitter consisting an electrically-pumped laser integrated with a 50 GHz modulator.
△ Less
Submitted 25 November, 2021; v1 submitted 16 November, 2021;
originally announced November 2021.
-
The Experiment for Cryogenic Large-aperture Intensity Map** (EXCLAIM)
Authors:
P. A. R. Ade,
C. J. Anderson,
E. M. Barrentine,
N. G. Bellis,
A. D. Bolatto,
P. C. Breysse,
B. T. Bulcha,
G. Cataldo,
J. A. Connors,
P. W. Cursey,
N. Ehsan,
H. C. Grant,
T. M. Essinger-Hileman,
L. A. Hess,
M. O. Kimball,
A. J. Kogut,
A. D. Lamb,
L. N. Lowe,
P. D. Mauskopf,
J. McMahon,
M. Mirzaei,
S. H. Moseley,
J. W. Mugge-Durum,
O. Noroozian,
U. Pen
, et al. (11 additional authors not shown)
Abstract:
The EXperiment for Cryogenic Large-Aperture Intensity Map** (EXCLAIM) is a cryogenic balloon-borne instrument that will survey galaxy and star formation history over cosmological time scales. Rather than identifying individual objects, EXCLAIM will be a pathfinder to demonstrate an intensity map** approach, which measures the cumulative redshifted line emission. EXCLAIM will operate at 420-540…
▽ More
The EXperiment for Cryogenic Large-Aperture Intensity Map** (EXCLAIM) is a cryogenic balloon-borne instrument that will survey galaxy and star formation history over cosmological time scales. Rather than identifying individual objects, EXCLAIM will be a pathfinder to demonstrate an intensity map** approach, which measures the cumulative redshifted line emission. EXCLAIM will operate at 420-540 GHz with a spectral resolution R=512 to measure the integrated CO and [CII] in redshift windows spanning 0 < z < 3.5. CO and [CII] line emissions are key tracers of the gas phases in the interstellar medium involved in star-formation processes. EXCLAIM will shed light on questions such as why the star formation rate declines at z < 2, despite continued clustering of the dark matter. The instrument will employ an array of six superconducting integrated grating-analog spectrometers (micro-spec) coupled to microwave kinetic inductance detectors (MKIDs). Here we present an overview of the EXCLAIM instrument design and status.
△ Less
Submitted 15 December, 2019;
originally announced December 2019.
-
CAPIR: Collaborative Action Planning with Intention Recognition
Authors:
Truong-Huy Dinh Nguyen,
David Hsu,
Wee-Sun Lee,
Tze-Yun Leong,
Leslie Pack Kaelbling,
Tomas Lozano-Perez,
Andrew Haydn Grant
Abstract:
We apply decision theoretic techniques to construct non-player characters that are able to assist a human player in collaborative games. The method is based on solving Markov decision processes, which can be difficult when the game state is described by many variables. To scale to more complex games, the method allows decomposition of a game task into subtasks, each of which can be modelled by a M…
▽ More
We apply decision theoretic techniques to construct non-player characters that are able to assist a human player in collaborative games. The method is based on solving Markov decision processes, which can be difficult when the game state is described by many variables. To scale to more complex games, the method allows decomposition of a game task into subtasks, each of which can be modelled by a Markov decision process. Intention recognition is used to infer the subtask that the human is currently performing, allowing the helper to assist the human in performing the correct task. Experiments show that the method can be effective, giving near-human level performance in hel** a human in a collaborative game.
△ Less
Submitted 26 June, 2012;
originally announced June 2012.