-
LM-IGTD: a 2D image generator for low-dimensional and mixed-type tabular data to leverage the potential of convolutional neural networks
Authors:
Vanesa Gómez-Martínez,
Francisco J. Lara-Abelenda,
Pablo Peiro-Corbacho,
David Chushig-Muzo,
Conceicao Granja,
Cristina Soguero-Ruiz
Abstract:
Tabular data have been extensively used in different knowledge domains. Convolutional neural networks (CNNs) have been successfully used in many applications where important information about data is embedded in the order of features (images), outperforming predictive results of traditional models. Recently, several researchers have proposed transforming tabular data into images to leverage the po…
▽ More
Tabular data have been extensively used in different knowledge domains. Convolutional neural networks (CNNs) have been successfully used in many applications where important information about data is embedded in the order of features (images), outperforming predictive results of traditional models. Recently, several researchers have proposed transforming tabular data into images to leverage the potential of CNNs and obtain high results in predictive tasks such as classification and regression. In this paper, we present a novel and effective approach for transforming tabular data into images, addressing the inherent limitations associated with low-dimensional and mixed-type datasets. Our method, named Low Mixed-Image Generator for Tabular Data (LM-IGTD), integrates a stochastic feature generation process and a modified version of the IGTD. We introduce an automatic and interpretable end-to-end pipeline, enabling the creation of images from tabular data. A map** between original features and the generated images is established, and post hoc interpretability methods are employed to identify crucial areas of these images, enhancing interpretability for predictive tasks. An extensive evaluation of the tabular-to-image generation approach proposed on 12 low-dimensional and mixed-type datasets, including binary and multi-class classification scenarios. In particular, our method outperformed all traditional ML models trained on tabular data in five out of twelve datasets when using images generated with LM-IGTD and CNN. In the remaining datasets, LM-IGTD images and CNN consistently surpassed three out of four traditional ML models, achieving similar results to the fourth model.
△ Less
Submitted 26 April, 2024;
originally announced June 2024.
-
Recent Developments within The Cosmic Ray Extremely Distributed Observatory (CREDO)
Authors:
David Alvarez-Castillo,
Piotr Homola,
Oleksandr Sushchov,
Jarosław Stasielak,
Sławomir Stuglik,
Dariusz Góra,
Vahab Nazari,
Cristina Oancea,
Carlos Granja,
Dmitriy Beznosko,
Noemi Zabari,
Alok C. Gupta,
Bohdan Hnatyk,
Alona Mozgova,
Marcin Kasztelan,
Marcin Bielewicz,
Peter Kovacs,
Bartosz Łozowski,
Mikhail V. Medvedev,
Justyna Miszczyk,
Łukasz Bibrzycki,
Michał Niedźwiecki,
Katarzyna Smelcerz,
Tomasz Hachaj Marcin Piekarczyk,
Maciej Pawlik
, et al. (14 additional authors not shown)
Abstract:
This contribution presents the recent research developments within the Cosmic Ray Extremely Distributed Observatory (CREDO) in the search for resolution of various scientific puzzles, ranging from fundamental physical questions to applications like the determination of earthquake precursors. The state-of-the art theoretical, numerical and computational aspects of these phenomena are addressed, as…
▽ More
This contribution presents the recent research developments within the Cosmic Ray Extremely Distributed Observatory (CREDO) in the search for resolution of various scientific puzzles, ranging from fundamental physical questions to applications like the determination of earthquake precursors. The state-of-the art theoretical, numerical and computational aspects of these phenomena are addressed, as well as recent experimental developments for detection.
△ Less
Submitted 6 March, 2024;
originally announced March 2024.
-
Particle Tracking, Recognition and LET Evaluation of Out-of-Field Proton Therapy Delivered to a Phantom with Implants
Authors:
Cristina Balan,
Carlos Granja,
Gennady Mytsin,
Sergey Shvidky,
Alexander Molokanov,
Lukas Marek,
Vasile Chis,
Cristina Oancea
Abstract:
This study aims to assess the composition of scattered particles generated in proton therapy for tumours situated proximal to titanium dental implants. The investigation involves decomposing the mixed field and recording Linear Energy Transfer (LET) spectra to quantify the influence of metallic dental inserts located behind the tumour. A conformal proton beam was used to deliver the treatment plan…
▽ More
This study aims to assess the composition of scattered particles generated in proton therapy for tumours situated proximal to titanium dental implants. The investigation involves decomposing the mixed field and recording Linear Energy Transfer (LET) spectra to quantify the influence of metallic dental inserts located behind the tumour. A conformal proton beam was used to deliver the treatment plan to an anthropomorphic head phantom with two types of implants (Ti and plastic) inserted in the target volume. The stray radiation resulting during the irradiation was detected by a hybrid semiconductor pixel detector MiniPIX Timepix3 that was placed distal to the Spread-out Bragg peak. Visualization and field decomposition of stray radiation were generated using algorithms trained in particle recognition based on artificial intelligence convolution neural networks (AI CNN). Spectral sensitive aspects of the scattered radiation were collected using two angular positions of the detector relative to the beam direction: 0 and 60°. Using AI CNN, 3 classes of particles were identified: protons, electrons & photons, ions & fast neutrons. Placing a Ti implant in the beam's path resulted in predominantly electrons and photons, contributing 52.2%, whereas for plastic implants, the contribution was 65.4%. Scattered protons comprised 45.5% and 31.9% with and without Ti inserts, respectively. The LET spectra was derived for each group of particles, with values ranging from 0.01 to 7.5 keVμm-1 for Ti/plastic implants. The low-LET component was primarily composed of electrons and photons, while the high-LET component corresponded to protons and ions. This method, complemented by directional maps, holds potential for evaluating and validating treatment plans involving stray radiation near organs at risk, offering precise discrimination of the mixt field, enhancing in this way the LET calculation.
△ Less
Submitted 21 December, 2023;
originally announced December 2023.
-
Silicon Carbide Timepix3 detector for quantum-imaging detection and spectral tracking of charged particles in wide range of energy and field-of-view
Authors:
Andrej Novak,
Carlos Granja,
Andrea Sagatova,
Jan Jakubek,
Bohumir Zatko,
Vladimir Vondracek,
Michal Andrlik,
Vaclav Zach,
Stepan Polansky,
Anuj Rathi,
Cristina Oancea
Abstract:
The hybrid architecture of the Timepix (TPX) family of detectors enables the use of different semiconductor sensors, most commonly silicon (Si), as well as high-density materials such as Cadmium Telluride (CdTe) or Gallium Arsenide (GaAs). For this purpose, we explore the potential of a silicon carbide (SiC) sensor bump-bonded on a Timepix3 detector as a radiation imaging and particle tracking det…
▽ More
The hybrid architecture of the Timepix (TPX) family of detectors enables the use of different semiconductor sensors, most commonly silicon (Si), as well as high-density materials such as Cadmium Telluride (CdTe) or Gallium Arsenide (GaAs). For this purpose, we explore the potential of a silicon carbide (SiC) sensor bump-bonded on a Timepix3 detector as a radiation imaging and particle tracking detector. SiC stands as a radiation-hard material also with the ability to operate at elevated temperatures up to several hundreds of degrees Celsius. As a result, this sensor material is more suitable for radiation harsh environments compared to conventional e.g., Si sensors. In this work, we evaluate the response for precise radiation spectrometry and high-resolution particle tracking of newly developed SiC Timepix3 detector which is built and operated as a compact radiation camera MiniPIX-Timepix3 with integrated readout electronics. Calibration measurements were conducted with mono-energetic proton beams with energies of 13, 22, and 31 MeV at the U-120M cyclotron at the Nuclear Physics Institute Czech Academy of Science (NPI CAS), Prague, as well as 100 and 226 MeV at the Proton Therapy Center Czech (PTC) in Prague. High-resolution pattern recognition analysis and single-particle spectral tracking are used for detailed inspection and understanding of the sensor response. Results include distributions of deposited energy and linear energy transfer (LET) spectra. The spatial uniformity of the pixelated detector response is examined in terms of homogeneously distributed deposited energy.
△ Less
Submitted 26 October, 2023;
originally announced October 2023.
-
Stray radiation produced in FLASH electron beams characterized by the MiniPIX Timepix3 Flex detector
Authors:
C. Oancea,
C. Bălan,
J. Pivec,
C. Granja,
J. Jakubek,
D. Chvatil,
V. Olsansky,
V. Chiş
Abstract:
This work aims to characterize ultra high dose rate pulses (UHDpulse) electron beams using the hybrid semiconductor pixel detector. The Timepix3 (TPX3) ASIC chip was used to measure the composition, spatial, time, and spectral characteristics of the secondary radiation fields from pulsed 15 to 23 MeV electron beams. The challenge is to develop a single compact detector that could extract spectrome…
▽ More
This work aims to characterize ultra high dose rate pulses (UHDpulse) electron beams using the hybrid semiconductor pixel detector. The Timepix3 (TPX3) ASIC chip was used to measure the composition, spatial, time, and spectral characteristics of the secondary radiation fields from pulsed 15 to 23 MeV electron beams. The challenge is to develop a single compact detector that could extract spectrometric and dosimetric information on such high flux short pulsed fields. For secondary beam measurements, PMMA plates of 1 and 8 cm thickness were placed in front of the electron beam, with a pulse duration of 3.5 microseconds. Timepix3 detectors with silicon sensors of 100 and 500 micrometers thickness were placed on a shifting stage allowing for data acquisition at various lateral positions to the beam axis. The use of the detector in FLEXI configuration enables suitable measurements in situ and minimal self shielding. Preliminary results highlight both the technique and the detector's ability to measure individual UHDpulses of electron beams delivered in short pulses. In addition, the use of the two signal chains per pixel enables the estimation of particle flux and the scattered dose rates (DRs) at various distances from the beam core, in mixed radiation fields.
△ Less
Submitted 31 January, 2022;
originally announced January 2022.
-
Characterization of Thin p-on-p Radiation Detectors with Active Edges
Authors:
T. Peltola,
X. Wu,
J. Kalliopuska,
C. Granja,
J. Jakubek,
M. Jakubek,
J. Härkönen,
A. Gädda
Abstract:
Active edge p-on-p silicon pixel detectors with thickness of 100 $μ$m were fabricated on 150 mm Float zone silicon wafers at VTT. By combining measured results and TCAD simulations, a detailed study of electric field distributions and charge collection performances as a function of applied voltage in a p-on-p detector was carried out. A comparison with the results of a more conventional active edg…
▽ More
Active edge p-on-p silicon pixel detectors with thickness of 100 $μ$m were fabricated on 150 mm Float zone silicon wafers at VTT. By combining measured results and TCAD simulations, a detailed study of electric field distributions and charge collection performances as a function of applied voltage in a p-on-p detector was carried out. A comparison with the results of a more conventional active edge p-on-n pixel sensor is presented. The results from 3D spatial map** show that at pixel-to-edge distances less than 100 $μ$m the sensitive volume is extended to the physical edge of the detector when the applied voltage is above full depletion. The results from a spectroscopic measurement demonstrate a good functionality of the edge pixels. The interpixel isolation above full depletion and the breakdown voltage were found to be equal to the p-on-n sensor while lower charge collection was observed in the p-on-p pixel sensor below 80 V. Simulations indicated this to be partly a result of a more favourable weighting field in the p-on-n sensor and partly of lower hole lifetimes in the p-bulk.
△ Less
Submitted 21 January, 2016; v1 submitted 6 January, 2016;
originally announced January 2016.