-
Calibrated Microwave Reflectance in Low-Temperature Scanning Tunneling Microscopy
Authors:
Bareld Wit,
Georg Gramse,
Stefan Müllegger
Abstract:
We outline calibrated measurements of the microwave reflection coefficient from the tunnel junction of an ultra-high vacuum low temperature scanning tunneling microscope. The microwave circuit design is described in detail, including an interferometer for enhanced signal-to-noise and a demodulation scheme for lock-in detection. A quantitative, in-situ procedure for impedance calibration based on t…
▽ More
We outline calibrated measurements of the microwave reflection coefficient from the tunnel junction of an ultra-high vacuum low temperature scanning tunneling microscope. The microwave circuit design is described in detail, including an interferometer for enhanced signal-to-noise and a demodulation scheme for lock-in detection. A quantitative, in-situ procedure for impedance calibration based on the numerical 3-error-term model is presented. Our procedure exploits the response of the microwave reflection signal due to the change of the tunneling conductance caused by sub-nm variation of the tunneling distance. Experimental calibration is achieved by a least-squares numerical fit of simultaneously measured conductance and microwave reflection retraction curves at finite conductance. Our method paves the way for nanoscale microscopy and spectroscopy of dielectric surface properties at GHz frequencies and cryogenic temperatures. This opens a promising pathway even for dielectric fingerprinting at the single molecule limit.
△ Less
Submitted 13 September, 2023; v1 submitted 17 April, 2023;
originally announced April 2023.
-
High-sensitivity electrochemical dual-QCM for reliable three-electrode measurements
Authors:
David Toth,
Manuel Kasper,
Ivan Alic,
Mohamed Awadein,
Andreas Ebner,
Doug Baney,
Georg Gramse,
Ferry Kienberger
Abstract:
Electrochemical quartz crystal microbalance (EC-QCM) is a versatile gravimetric technique that allows for parallel characterization of mass deposition and electrochemical properties. Despite its broad applicability, simultaneous characterization of two electrodes remains challenging due to practical difficulties posed by the dampening from fixture parasitics and the dissipative medium. In this stu…
▽ More
Electrochemical quartz crystal microbalance (EC-QCM) is a versatile gravimetric technique that allows for parallel characterization of mass deposition and electrochemical properties. Despite its broad applicability, simultaneous characterization of two electrodes remains challenging due to practical difficulties posed by the dampening from fixture parasitics and the dissipative medium. In this study, we present a dual electrochemical QCM (dual EC-QCM) that is employed in a three-electrode configuration to enable consequent monitoring of mass deposition and viscous loading on two crystals, the working electrode (WE) and the counter electrode (CE). A novel cor-rection approach along with a three standard complex impedance calibration is employed to overcome the effect of dampening while kee** high spectral sensitivity. Separation of viscous loading and rigid mass deposition is achieved by robust characterization of the complex impedance at the resonance frequency. Validation of the presented system is done by cyclic voltammetry characterization of Ag underpotential deposition on gold. The results indicate mass deposition of 412.2 ng for the WE and 345.6 ng for the CE, reflecting a difference of the initially present Ag adhered to the surface. We also performed higher harmonic measurements that further corroborate the sensitivity and reproducibility of the dual EC-QCM. The demonstrated approach is especially intriguing for electrochemical energy storage applications where mass detection with multiple electrodes is desired.
△ Less
Submitted 7 March, 2021;
originally announced March 2021.
-
Attoampere Nanoelectrochemistry
Authors:
Simon Grall,
Ivan Alić,
Eleonora Pavoni,
Teruo Fujii,
Stefan Müllegger,
Marco Farina,
Nicolas Clément,
Georg Gramse
Abstract:
Local electrochemical measurements and imaging at the nanoscale are crucial for the future development of molecular devices, sensors, materials engineering, electrophysiology and various energy applications from artificial photosynthesis to batteries. The ultimate step towards single-molecule sensitivity requires the measurement of aA currents, which is three orders of magnitude below that of curr…
▽ More
Local electrochemical measurements and imaging at the nanoscale are crucial for the future development of molecular devices, sensors, materials engineering, electrophysiology and various energy applications from artificial photosynthesis to batteries. The ultimate step towards single-molecule sensitivity requires the measurement of aA currents, which is three orders of magnitude below that of current state-of-the-art measurement abilities. Here, we show electrochemical measurements at the sub aA level and <80 nm spatial resolution, that we reach by exploiting the ultra-high sensitivity of our GHz microscope for local faradaic interface capacitances. We demonstrate this for a well-known surface-bound ferrocene alkyl monolayer, a system that cannot be studied at the nanoscale unless large nanoarrays are used11. We report the simultaneous measurement of local cyclic voltammograms (CV) which provide atomistic information on the respective electron transfer reaction and reveal two molecular configurations with a similar redox energy potential -- insights inaccessible by electrochemical ensemble measurements.
△ Less
Submitted 20 November, 2020;
originally announced November 2020.
-
Nanoscale charge accumulation and its effect on carrier dynamics in tri-cation perovskite structures
Authors:
David Toth,
Bekele Hailegnaw,
Filipe Richheimer,
Sebastian Wood,
Fernando A. Castro,
Ferry Kienberger,
Markus C. Scharber,
Georg Gramse
Abstract:
Nanoscale investigations by scanning probe microscopy have provided major contributions to the rapid development of organic-inorganic halide perovskites (OIHP) as optoelectronic devices. Further improvement of device level properties requires a deeper understanding of the performance-limiting mechanisms such as ion migration, phase segregation and their effects on charge extraction both at the nan…
▽ More
Nanoscale investigations by scanning probe microscopy have provided major contributions to the rapid development of organic-inorganic halide perovskites (OIHP) as optoelectronic devices. Further improvement of device level properties requires a deeper understanding of the performance-limiting mechanisms such as ion migration, phase segregation and their effects on charge extraction both at the nano- and macroscale. Here, we have studied the dynamic electrical response of Cs0.05(FA0.83-MA0.17)0.95PbI3-xBrx perovskite structures by employing conventional and microsecond time-resolved Kelvin probe force microscopy (KPFM). Our results indicate strong negative charge carrier trap** upon illumination and very slow (>1s) relaxation of charges at the grain boundaries. The fast electronic recombination and transport dynamics on the microsecond scale probed by time-resolved KPFM show diffusion of charge carriers towards grain boundaries and indicate locally higher recombination rates due to intrinsic spatial heterogeneity. The nanoscale electrostatic effects revealed are summarized in a collective model for mixed-halide CsFAMA. Results on multilayer solar cell structures draw direct relations between nanoscale ionic transport, electron accumulation, recombination properties and the final device performance. Our findings extend the current understanding of complex charge carrier dynamics in stable multi-cation OIHP structures.
△ Less
Submitted 11 June, 2020;
originally announced June 2020.
-
S-parameter calibration procedure for multiport microwave imaging systems
Authors:
Manuel Kasper,
Mykolas Ragulskis,
Georg Gramse,
Ferry Kienberger
Abstract:
Multitude of antennas are typically used in microwave imaging systems. Here we outline a simple and effective calibration method for multiport imaging systems. By using only one additional component, an electronic calibration module (ECal), one port is calibrated and the calibration plane is thereby moved to the antenna connector. Assuming all antennas interact with the test phantom in the same wa…
▽ More
Multitude of antennas are typically used in microwave imaging systems. Here we outline a simple and effective calibration method for multiport imaging systems. By using only one additional component, an electronic calibration module (ECal), one port is calibrated and the calibration plane is thereby moved to the antenna connector. Assuming all antennas interact with the test phantom in the same way, the one-port calibration is transferred to all other antennas. For full calibration including the transmission path between antennas, the unknown thru technique is used. This calibration procedure is simple and it can be fully automated, and no RF components are perturbed.
△ Less
Submitted 1 May, 2019;
originally announced May 2019.
-
Effects of Dielectric Stoichiometry on the Photoluminescence Properties of Encapsulated WSe2 Monolayers
Authors:
Javier Martín-Sánchez,
Antonio Mariscal,
Marta De Luca,
Aitana Tarazaga Martín-Luengo,
Georg Gramse,
Alma Halilovic,
Rosalía Serna,
Alberta Bonanni,
Ilaria Zardo,
Rinaldo Trotta,
Armando Rastelli
Abstract:
Two-dimensional transition-metal-dichalcogenide semiconductors have emerged as promising candidates for optoelectronic devices with unprecedented properties and ultra-compact performances. However atomically thin materials are highly sensitive to surrounding dielectric media, which imposes severe limitations to their practical applicability. Hence for their suitable integration into devices, the d…
▽ More
Two-dimensional transition-metal-dichalcogenide semiconductors have emerged as promising candidates for optoelectronic devices with unprecedented properties and ultra-compact performances. However atomically thin materials are highly sensitive to surrounding dielectric media, which imposes severe limitations to their practical applicability. Hence for their suitable integration into devices, the development of reliable encapsulation procedures that preserve their physical properties are required. Here, the excitonic photoluminescence of WSe2 monolayer flakes is assessed, at room temperature and 10 K, on mechanically exfoliated flakes encapsulated with SiOx and AlxOy layers employing chemical and physical deposition techniques. Conformal flakes coating on untreated - non-functionalized - flakes is successfully demonstrated by all the techniques except for atomic layer deposition, where a cluster-like oxide coating is observed. No significant compositional or strain state changes in the flakes are detected upon encapsulation by any of the techniques. Remarkably, our results evidence that the flakes' optical emission is strongly influenced by the quality of the encapsulating oxide - stoichiometry -. When the encapsulation is carried out with slightly sub-stoichiometric oxides two remarkable phenomena are observed. First, there is a clear electrical do** of the monolayers that is revealed through a dominant trion - charged exciton - room-temperature photoluminescence. Second, a strong decrease of the monolayers optical emission is measured attributed to non-radiative recombination processes and/or carriers transfer from the flake to the oxide. Power- and temperature-dependent photoluminescence measurements further confirm that stoichiometric oxides obtained by physical deposition lead to a successful encapsulation.
△ Less
Submitted 17 April, 2017; v1 submitted 17 March, 2017;
originally announced March 2017.