-
Development of AC-LGAD detector with finer pitch electrodes for high energy physics experiments
Authors:
Sayuka Kita,
Koji Nakamura,
Tomoka Imamura,
Ikumi Goya,
Kazuhiko Hara
Abstract:
Low-Gain Avalanche Diode (LGAD) sensor is one of candidate sensors for the tracker at future hadron collider experiments. To use this sensor as a tracking detector, AC-LGAD sensor is being developed which has both timing and spatial resolutions. In high luminosity environments, good timing resolution (typically 30 ps) together with $\mathcal{O}$(10) ${\mathrmμ}$m spatial resolution helps to reduce…
▽ More
Low-Gain Avalanche Diode (LGAD) sensor is one of candidate sensors for the tracker at future hadron collider experiments. To use this sensor as a tracking detector, AC-LGAD sensor is being developed which has both timing and spatial resolutions. In high luminosity environments, good timing resolution (typically 30 ps) together with $\mathcal{O}$(10) ${\mathrmμ}$m spatial resolution helps to reduce pileup effect and reconstruct tracks correctly. By optimizing fabrication parameters, 80 ${\mathrmμ}$m pitch strip and 100 ${\mathrmμ}$m pitch pixel sensors are successfully produced. The signal height (MPV) was 39.26$\pm$0.08 mV and 128.9$\pm$3.3 mV, respectively, for penetrating $β$ particles. The observed 60% of signal reduction of the strip sensor is explained by a larger inter-electrode capacitance compared with the pixel sensor. In this paper, we present the performance of fine electrode pitch AC-LGAD sensors including the pulse height and cross-talk of pixel and strip type sensors evaluated using a $β$-ray source and the detection efficiency measured in an 800 MeV electron beam.
△ Less
Submitted 21 May, 2023;
originally announced May 2023.
-
Optimization of capacitive coupled Low Gain Avalanche Diode (AC-LGAD) sensors for precise time and spatial resolution
Authors:
Sayuka Kita,
Koji Nakamura,
Tatsuki Ueda,
Ikumi Goya,
Kazuhiko Hara
Abstract:
Capacitive-coupled Low-Gain Avalanche Diode (AC-LGAD) sensors are being developed for high-energy particle physics experiments as a detector which provides fast time information with fine spatial resolution. This paper describes optimizations of AC-LGAD sensor fabrication parameters, such as do** concentrations of the gain and electrode layers as well as the AC insulator capacitance, to realize…
▽ More
Capacitive-coupled Low-Gain Avalanche Diode (AC-LGAD) sensors are being developed for high-energy particle physics experiments as a detector which provides fast time information with fine spatial resolution. This paper describes optimizations of AC-LGAD sensor fabrication parameters, such as do** concentrations of the gain and electrode layers as well as the AC insulator capacitance, to realize $\mathcal{O}$(10)~\um{} spacial resolution, small charge cross talk to the neighboring electrodes, detection efficiency higher than 99\% at a 10$^{-4}$ fake rate and time resolution of about 30~ps. The radiation tolerance of the sensor is presented. In addition, further application to a device capable of visible and infra-red light detection is discussed.
△ Less
Submitted 15 July, 2022;
originally announced July 2022.
-
Characterization of BNL and HPK AC-LGAD sensors with a 120 GeV proton beam
Authors:
Ryan Heller,
Christopher Madrid,
Artur Apresyan,
William K. Brooks,
Wei Chen,
Gabriele D'Amen,
Gabriele Giacomini,
Ikumi Goya,
Kazuhiko Hara,
Sayuka Kita,
Sergey Los,
Adam Molnar,
Koji Nakamura,
Cristián Peña,
Claudio San Martín,
Alessandro Tricoli,
Tatsuki Ueda,
Si Xie
Abstract:
We present measurements of AC-LGADs performed at the Fermilab's test beam facility using 120 GeV protons. We studied the performance of various strip and pad AC-LGAD sensors that were produced by BNL and HPK. The measurements are performed with our upgraded test beam setup that utilizes a high precision telescope tracker, and a simultaneous readout of up to 7 channels per sensor, which allows deta…
▽ More
We present measurements of AC-LGADs performed at the Fermilab's test beam facility using 120 GeV protons. We studied the performance of various strip and pad AC-LGAD sensors that were produced by BNL and HPK. The measurements are performed with our upgraded test beam setup that utilizes a high precision telescope tracker, and a simultaneous readout of up to 7 channels per sensor, which allows detailed studies of signal sharing characteristics. These measurements allow us to assess the differences in designs between different manufacturers, and optimize them based on experimental performance. We then study several reconstruction algorithms to optimize position and time resolutions that utilize the signal sharing properties of each sensor. We present a world's first demonstration of silicon sensors in a test beam that simultaneously achieve better than 6-10 micron position and 30 ps time resolution. This represents a substantial improvement to the spatial resolution than would be obtained with binary readout of sensors with similar pitch.
△ Less
Submitted 29 March, 2022; v1 submitted 19 January, 2022;
originally announced January 2022.