-
Production and Integration of the ATLAS Insertable B-Layer
Authors:
B. Abbott,
J. Albert,
F. Alberti,
M. Alex,
G. Alimonti,
S. Alkire,
P. Allport,
S. Altenheiner,
L. Ancu,
E. Anderssen,
A. Andreani,
A. Andreazza,
B. Axen,
J. Arguin,
M. Backhaus,
G. Balbi,
J. Ballansat,
M. Barbero,
G. Barbier,
A. Bassalat,
R. Bates,
P. Baudin,
M. Battaglia,
T. Beau,
R. Beccherle
, et al. (352 additional authors not shown)
Abstract:
During the shutdown of the CERN Large Hadron Collider in 2013-2014, an additional pixel layer was installed between the existing Pixel detector of the ATLAS experiment and a new, smaller radius beam pipe. The motivation for this new pixel layer, the Insertable B-Layer (IBL), was to maintain or improve the robustness and performance of the ATLAS tracking system, given the higher instantaneous and i…
▽ More
During the shutdown of the CERN Large Hadron Collider in 2013-2014, an additional pixel layer was installed between the existing Pixel detector of the ATLAS experiment and a new, smaller radius beam pipe. The motivation for this new pixel layer, the Insertable B-Layer (IBL), was to maintain or improve the robustness and performance of the ATLAS tracking system, given the higher instantaneous and integrated luminosities realised following the shutdown. Because of the extreme radiation and collision rate environment, several new radiation-tolerant sensor and electronic technologies were utilised for this layer. This paper reports on the IBL construction and integration prior to its operation in the ATLAS detector.
△ Less
Submitted 6 June, 2018; v1 submitted 2 March, 2018;
originally announced March 2018.
-
A combined ultrasonic flow meter and binary vapour mixture analyzer for the ATLAS silicon tracker
Authors:
R. Bates,
M. Battistin,
S. Berry,
J. Berthoud,
A. Bitadze,
P. Bonneau,
J. Botelho-Direito,
N. Bousson,
G. Boyd,
G. Bozza,
E. Da Riva,
C. Degeorge,
B. DiGirolamo,
M. Doubek,
D. Giugni,
J. Godlewski,
G. Hallewell,
S. Katunin,
D. Lombard,
M. Mathieu,
S. McMahon,
K. Nagai,
E. Perez-Rodriguez,
C. Rossi,
A. Rozanov
, et al. (3 additional authors not shown)
Abstract:
An upgrade to the ATLAS silicon tracker cooling control system may require a change from C3F8 (octafluoro-propane) evaporative coolant to a blend containing 10-25% of C2F6 (hexafluoro-ethane). Such a change will reduce the evaporation temperature to assure thermal stability following radiation damage accumulated at full LHC luminosity. Central to this upgrade is a new ultrasonic instrument in whic…
▽ More
An upgrade to the ATLAS silicon tracker cooling control system may require a change from C3F8 (octafluoro-propane) evaporative coolant to a blend containing 10-25% of C2F6 (hexafluoro-ethane). Such a change will reduce the evaporation temperature to assure thermal stability following radiation damage accumulated at full LHC luminosity. Central to this upgrade is a new ultrasonic instrument in which sound transit times are continuously measured in opposite directions in flowing gas at known temperature and pressure to deduce the C3F8/C2F6 flow rate and mixture composition. The instrument and its Supervisory, Control and Data Acquisition (SCADA) software are described in this paper. Several geometries for the instrument are in use or under evaluation. An instrument with a pinched axial geometry intended for analysis and measurement of moderate flow rates has demonstrated a mixture resolution of 3.10-3 for C3F8/C2F6 molar mixtures with 20%C2F6, and a flow resolution of 2% of full scale for mass flows up to 30gs-1. In mixtures of widely-differing molecular weight (mw), higher mixture precision is possible: a sensitivity of <5.10-5 to leaks of C3F8 into part of the ATLAS tracker nitrogen envelope (mw difference 160) has been seen. An instrument with an angled sound path geometry has been developed for use at high fluorocarbon mass flow rates of around 1.2 kgs-1 - corresponding to full flow in a new 60kW thermosiphon recirculator under construction for the ATLAS silicon tracker. Extensive computational fluid dynamics studies were performed to determine the preferred geometry (ultrasonic transducer spacing and placement, together with the sound crossing angle with respect to the vapour flow direction). A prototype with 45deg crossing angle has demonstrated a flow resolution of 1.9% of full scale for linear flow velocities up to 15 ms-1. The instrument has many potential applications.
△ Less
Submitted 17 October, 2012;
originally announced October 2012.
-
Expected Performance of the ATLAS Experiment - Detector, Trigger and Physics
Authors:
The ATLAS Collaboration,
G. Aad,
E. Abat,
B. Abbott,
J. Abdallah,
A. A. Abdelalim,
A. Abdesselam,
O. Abdinov,
B. Abi,
M. Abolins,
H. Abramowicz,
B. S. Acharya,
D. L. Adams,
T. N. Addy,
C. Adorisio,
P. Adragna,
T. Adye,
J. A. Aguilar-Saavedra,
M. Aharrouche,
S. P. Ahlen,
F. Ahles,
A. Ahmad,
H. Ahmed,
G. Aielli,
T. Akdogan
, et al. (2587 additional authors not shown)
Abstract:
A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on…
▽ More
A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on simulations of the detector and physics processes, with particular emphasis given to the data expected from the first years of operation of the LHC at CERN.
△ Less
Submitted 14 August, 2009; v1 submitted 28 December, 2008;
originally announced January 2009.
-
CUORE: A Cryogenic Underground Observatory for Rare Events
Authors:
C. Arnaboldi,
F. T. Avignone III,
J. Beeman,
M. Barucci,
M. Balata,
C. Brofferio,
C. Bucci,
S. Cebrian,
R. J. Creswick,
S. Capelli,
L. Carbone,
O. Cremonesi,
A. de Ward,
E. Fiorini,
H. A. Farach,
G. Frossati,
A. Giuliani,
D. Giugni,
P. Gorla,
E. E. Haller,
I. G. Irastorza,
R. J. McDonald,
A. Morales,
E. B. Norman,
P. Negri
, et al. (14 additional authors not shown)
Abstract:
CUORE is a proposed tightly packed array of 1000 TeO2 bolometers, each being a cube 5 cm on a side with a mass of 760 g. The array consists of 25 vertical towers, arranged in a square of 5 towers by 5 towers, each containing 10 layers of 4 crystals. The design of the detector is optimized for ultralow-background searches: for neutrinoless double beta decay of 130Te (33.8% abundance), cold dark m…
▽ More
CUORE is a proposed tightly packed array of 1000 TeO2 bolometers, each being a cube 5 cm on a side with a mass of 760 g. The array consists of 25 vertical towers, arranged in a square of 5 towers by 5 towers, each containing 10 layers of 4 crystals. The design of the detector is optimized for ultralow-background searches: for neutrinoless double beta decay of 130Te (33.8% abundance), cold dark matter, solar axions, and rare nuclear decays. A preliminary experiment involving 20 crystals 3x3x6 cm3 of 340 g has been completed, and a single CUORE tower is being constructed as a smaller scale experiment called CUORICINO. The expected performance and sensitivity, based on Monte Carlo simulations and extrapolations of present results, are reported.
△ Less
Submitted 20 December, 2002;
originally announced December 2002.