HeCTOr: the $^3$He Cryogenic Target of Orsay for direct nuclear reactions with radioactive beams
Authors:
F. Galtarossa,
M. Pierens,
M. Assié,
V. Delpech,
F. Galet,
H. Saugnac,
D. Brugnara,
D. Ramos,
D. Beaumel,
P. Blache,
M. Chabot,
F. Chatelet,
E. Clément,
F. Flavigny,
A. Giret,
A. Gottardo,
J. Goupil,
A. Lemasson,
A. Matta,
L. Ménager,
E. Rindel
Abstract:
Direct nuclear reactions with radioactive ion beams represent an extremely powerful tool to extend the study of fundamental nuclear properties far from stability. These measurements require pure and dense targets to cope with the low beam intensities. The $^3$He cryogenic target HeCTOr has been designed to perform direct nuclear reactions in inverse kinematics. The high density of $^3$He scatterin…
▽ More
Direct nuclear reactions with radioactive ion beams represent an extremely powerful tool to extend the study of fundamental nuclear properties far from stability. These measurements require pure and dense targets to cope with the low beam intensities. The $^3$He cryogenic target HeCTOr has been designed to perform direct nuclear reactions in inverse kinematics. The high density of $^3$He scattering centers, of the order of 10$^{20}$ atoms/cm$^2$, makes it particularly suited for experiments where low-intensity radioactive beams are involved. The target was employed in a first in-beam experiment, where it was coupled to state-of-the-art gamma-ray and particle detectors. It showed excellent stability in gas temperature and density over time. Relevant experimental quantities, such as total target thickness, energy resolution and gamma-ray absorption, were determined through dedicated Geant4 simulations and found to be in good agreement with experimental data.
△ Less
Submitted 21 August, 2021; v1 submitted 12 May, 2021;
originally announced May 2021.
The MUGAST-AGATA-VAMOS campaign : set-up and performance
Authors:
M. Assié,
E. Clément,
A. Lemasson,
D. Ramos,
A. Raggio,
I. Zanon,
F. Galtarossa,
C. Lenain,
J. Casal,
F. Flavigny,
A. Matta,
D. Mengoni,
D. Beaumel,
Y. Blumenfeld,
R. Borcea,
D. Brugnara,
W. Catford,
F. de Oliveira,
N. De Séréville,
F. Didierjean,
C. Aa. Diget,
J. Dudouet,
B. Fernandez-Dominguez,
C. Fougères,
G. Frémont
, et al. (24 additional authors not shown)
Abstract:
The MUGAST-AGATA-VAMOS set-up at GANIL combines the MUGAST highly-segmented silicon array with the state-of-the-art AGATA array and the large acceptance VAMOS spectrometer. The mechanical and electronics integration copes with the constraints of maximum efficiency for each device, in particular γ-ray transparency for the silicon array. This complete set-up offers a unique opportunity to perform ex…
▽ More
The MUGAST-AGATA-VAMOS set-up at GANIL combines the MUGAST highly-segmented silicon array with the state-of-the-art AGATA array and the large acceptance VAMOS spectrometer. The mechanical and electronics integration copes with the constraints of maximum efficiency for each device, in particular γ-ray transparency for the silicon array. This complete set-up offers a unique opportunity to perform exclusive measurements of direct reactions with the radioactive beams from the SPIRAL1 facility. The performance of the set-up is described through its commissioning and two examples of transfer reactions measured during the campaign. High accuracy spectroscopy of the nuclei of interest, including cross-sections and angular distributions, is achieved through the triple-coincidence measurement. In addition, the correction from Doppler effect of the γ-ray energies is improved by the detection of the light particles and the use of two-body kinematics and a full rejection of the background contributions is obtained through the identification of heavy residues. Moreover, the system can handle high intensity beams (up to 108 pps). The particle identification based on the measurement of the time-of-flight between MUGAST and VAMOS and the reconstruction of the trajectories is investigated.
△ Less
Submitted 21 April, 2021;
originally announced April 2021.