Effects of ballistic transport on the thermal resistance and temperature profile in nanowires
Authors:
R. Meyer,
Graham W. Gibson,
Alexander N. Robillard
Abstract:
Effects of ballistic transport on the temperature profiles and thermal resistance in nanowires are studied. Computer simulations of nanowires between a heat source and a heat sink have shown that in the middle of such wires the temperature gradient is reduced compared to Fourier's law with steep gradients close to the heat source and sink. In this work, results from molecular dynamics and phonon M…
▽ More
Effects of ballistic transport on the temperature profiles and thermal resistance in nanowires are studied. Computer simulations of nanowires between a heat source and a heat sink have shown that in the middle of such wires the temperature gradient is reduced compared to Fourier's law with steep gradients close to the heat source and sink. In this work, results from molecular dynamics and phonon Monte Carlo simulations of the heat transport in nanowires are compared to a radiator model which predicts a reduced gradient with discrete jumps at the wire ends. The comparison shows that for wires longer than the typical mean free path of phonons the radiator model is able to account for ballistic transport effects. The steep gradients at the wire ends are then continuous manifestations of the discrete jumps in the model.
△ Less
Submitted 27 June, 2024;
originally announced June 2024.
Determining the vibrations between sensor and sample in SQUID microscopy
Authors:
Daniel Schiessl,
John R. Kirtley,
Lisa Paulius,
Aaron J. Rosenberg,
Johanna C. Palmstrom,
Rahim R. Ullah,
Connor M. Holland,
Y. -K. -K. Jung,
Mark B. Ketchen,
Gerald W. Gibson, Jr.,
Kathryn A. Moler
Abstract:
Vibrations can cause noise in scanning probe microscopies. Relative vibrations between the scanning sensor and the sample are important but can be more difficult to determine than absolute vibrations or vibrations relative to the laboratory. We measure the noise spectral density in a scanning SQUID microscope as a function of position near a localized source of magnetic field, and show that we can…
▽ More
Vibrations can cause noise in scanning probe microscopies. Relative vibrations between the scanning sensor and the sample are important but can be more difficult to determine than absolute vibrations or vibrations relative to the laboratory. We measure the noise spectral density in a scanning SQUID microscope as a function of position near a localized source of magnetic field, and show that we can determine the spectra of all three components of the relative sensor-sample vibrations. This method is a powerful tool for diagnosing vibrational noise in scanning microscopies.
△ Less
Submitted 2 October, 2016;
originally announced October 2016.
Scanning SQUID susceptometers with sub-micron spatial resolution
Authors:
John R. Kirtley,
Lisa Paulius,
Aaron J. Rosenberg,
Johanna C. Palmstrom,
Connor M. Holland,
Eric M. Spanton,
Daniel Schiessl,
Colin L. Jermain,
Jonathan Gibbons,
Y. -K. -K. Fung,
Martin E. Huber,
Daniel C. Ralph,
Mark B. Ketchen,
Gerald W. Gibson Jr.,
Kathryn A. Moler
Abstract:
Superconducting QUantum Interference Device (SQUID) microscopy has excellent magnetic field sensitivity, but suffers from modest spatial resolution when compared with other scanning probes. This spatial resolution is determined by both the size of the field sensitive area and the spacing between this area and the sample surface. In this paper we describe scanning SQUID susceptometers that achieve…
▽ More
Superconducting QUantum Interference Device (SQUID) microscopy has excellent magnetic field sensitivity, but suffers from modest spatial resolution when compared with other scanning probes. This spatial resolution is determined by both the size of the field sensitive area and the spacing between this area and the sample surface. In this paper we describe scanning SQUID susceptometers that achieve sub-micron spatial resolution while retaining a white noise floor flux sensitivity of $\approx 2μΦ_0/Hz^{1/2}$. This high spatial resolution is accomplished by deep sub-micron feature sizes, well shielded pickup loops fabricated using a planarized process, and a deep etch step that minimizes the spacing between the sample surface and the SQUID pickup loop. We describe the design, modeling, fabrication, and testing of these sensors. Although sub-micron spatial resolution has been achieved previously in scanning SQUID sensors, our sensors not only achieve high spatial resolution, but also have integrated modulation coils for flux feedback, integrated field coils for susceptibility measurements, and batch processing. They are therefore a generally applicable tool for imaging sample magnetization, currents, and susceptibilities with higher spatial resolution than previous susceptometers.
△ Less
Submitted 25 July, 2016; v1 submitted 30 May, 2016;
originally announced May 2016.