-
Clock-line-mediated Sisyphus Cooling
Authors:
Chun-Chia Chen,
Jacob L. Siegel,
Benjamin D. Hunt,
Tanner Grogan,
Youssef S. Hassan,
Kyle Beloy,
Kurt Gibble,
Roger C. Brown,
Andrew D. Ludlow
Abstract:
We demonstrate sub-recoil Sisyphus cooling using the long-lived $^{3}\mathrm{P}_{0}$ clock state in alkaline-earth-like ytterbium. A 1388 nm optical standing wave nearly resonant with the $^{3}\textrm{P}_{0}$$\,\rightarrow$$\,^{3}\textrm{D}_{1}$ transition creates a spatially periodic light shift of the $^{3}\textrm{P}_{0}$ clock state. Following excitation on the ultranarrow clock transition, we…
▽ More
We demonstrate sub-recoil Sisyphus cooling using the long-lived $^{3}\mathrm{P}_{0}$ clock state in alkaline-earth-like ytterbium. A 1388 nm optical standing wave nearly resonant with the $^{3}\textrm{P}_{0}$$\,\rightarrow$$\,^{3}\textrm{D}_{1}$ transition creates a spatially periodic light shift of the $^{3}\textrm{P}_{0}$ clock state. Following excitation on the ultranarrow clock transition, we observe Sisyphus cooling in this potential, as the light shift is correlated with excitation to $^{3}\textrm{D}_{1}$ and subsequent spontaneous decay to the $^{1}\textrm{S}_{0}$ ground state. We observe that cooling enhances the loading efficiency of atoms into a 759 nm magic-wavelength one-dimensional (1D) optical lattice, as compared to standard Doppler cooling on the $^{1}\textrm{S}_{0}$$\,\rightarrow\,$$^{3}\textrm{P}_{1}$ transition. Sisyphus cooling yields temperatures below 200 nK in the weakly confined, transverse dimensions of the 1D optical lattice. These lower temperatures improve optical lattice clocks by facilitating the use of shallow lattices with reduced light shifts, while retaining large atom numbers to reduce the quantum projection noise. This Sisyphus cooling can be pulsed or continuous and is applicable to a range of quantum metrology applications.
△ Less
Submitted 19 June, 2024;
originally announced June 2024.
-
Ratchet Loading and Multi-Ensemble Operation in an Optical Lattice Clock
Authors:
Youssef S. Hassan,
Takumi Kobayashi,
Tobias Bothwell,
Jacob L. Seigel,
Benjamin D. Hunt,
Kyle Beloy,
Kurt Gibble,
Tanner Grogan,
Andrew D. Ludlow
Abstract:
We demonstrate programmable control over the spatial distribution of ultra-cold atoms confined in an optical lattice. The control is facilitated through a combination of spatial manipulation of the magneto-optical trap and atomic population shelving to a metastable state. We first employ the technique to load an extended (5 mm) atomic sample with uniform density in an optical lattice clock, reduci…
▽ More
We demonstrate programmable control over the spatial distribution of ultra-cold atoms confined in an optical lattice. The control is facilitated through a combination of spatial manipulation of the magneto-optical trap and atomic population shelving to a metastable state. We first employ the technique to load an extended (5 mm) atomic sample with uniform density in an optical lattice clock, reducing atomic interactions and realizing remarkable frequency homogeneity across the atomic cloud. We also prepare multiple spatially separated atomic ensembles and realize multi-ensemble clock operation within the standard one-dimensional (1D) optical lattice clock architecture. Leveraging this technique, we prepare two oppositely spin-polarized ensembles that are independently addressable, offering a platform for implementing spectroscopic protocols for enhanced tracking of local oscillator phase. Finally, we demonstrate a relative fractional frequency instability at one second of $2.4(1) \times10^{-17}$ between two ensembles, useful for characterization of intra-lattice differential systematics.
△ Less
Submitted 30 May, 2024;
originally announced May 2024.
-
A many-channel FPGA control system
Authors:
Daniel T. Schussheim,
Kurt Gibble
Abstract:
We describe a many-channel experiment control system based on a field-programmable gate array (FPGA). The system has 16 bit resolution on 10 analog 100 MS/s input channels, 14 analog 100 MS/s output channels, 16 slow analog input and output channels, dozens of digital inputs and outputs, and a touchscreen display for experiment control and monitoring. The system can support 10 servo loops with 155…
▽ More
We describe a many-channel experiment control system based on a field-programmable gate array (FPGA). The system has 16 bit resolution on 10 analog 100 MS/s input channels, 14 analog 100 MS/s output channels, 16 slow analog input and output channels, dozens of digital inputs and outputs, and a touchscreen display for experiment control and monitoring. The system can support 10 servo loops with 155 ns latency and MHz bandwidths, in addition to as many as 30 lower bandwidth servos. We demonstrate infinite-impulse-response (IIR) proportional-integral-differential (PID) filters with 30 ns latency by using only bit-shifts and additions. These IIR filters allow timing margin at 100 MS/s and use fewer FPGA resources than straightforward multiplier-based filters, facilitating many servos on a single FPGA. We present several specific applications: Hänsch-Couillaud laser locks with automatic lock acquisition and a slow dither correction of lock offsets, variable duty cycle temperature servos, and the generation of multiple synchronized arbitrary waveforms.
△ Less
Submitted 29 July, 2023;
originally announced July 2023.
-
Isotope Shifts in Cadmium as a Sensitive Probe for Physics Beyond the Standard Model
Authors:
B. Ohayon,
S. Hofsäss,
J. E. Padilla-Castillo,
S. C. Wright,
G. Meijer,
S. Truppe,
K. Gibble,
B. K. Sahoo
Abstract:
Isotope shifts (ISs) in atomic energy levels are sensitive probes of nuclear structure and new physics beyond the Standard Model. We present an analysis of the ISs of the cadmium atom (Cd I) and singly charged cadmium ion (Cd II). ISs of the 229 nm, 326 nm, 361 nm and 480 nm lines of Cd I are measured with a variety of techniques; buffer-gas-cooled beam spectroscopy, capturing atoms in a magneto-o…
▽ More
Isotope shifts (ISs) in atomic energy levels are sensitive probes of nuclear structure and new physics beyond the Standard Model. We present an analysis of the ISs of the cadmium atom (Cd I) and singly charged cadmium ion (Cd II). ISs of the 229 nm, 326 nm, 361 nm and 480 nm lines of Cd I are measured with a variety of techniques; buffer-gas-cooled beam spectroscopy, capturing atoms in a magneto-optic-trap, and optical pum**. IS constants for the D1 and D2 lines of Cd II are calculated with high accuracy by employing analytical response relativistic coupled-cluster theory in the singles, doubles and triples approximations. Combining the calculations for Cd II with experiments, we infer IS constants for all low-lying transitions in Cd I. We benchmark these constants as calculated via different many-body methods. Our calculations for Cd II enable nuclear charge radii of Cd isotopes to be extracted with unprecedented accuracy. The combination of our precise calculations and measurements shows that King Plots for Cd I can improve the state-of-theart sensitivity to a new heavy boson by up to two orders of magnitude.
△ Less
Submitted 29 August, 2022;
originally announced August 2022.
-
Cold Atoms in Space: Community Workshop Summary and Proposed Road-Map
Authors:
Ivan Alonso,
Cristiano Alpigiani,
Brett Altschul,
Henrique Araujo,
Gianluigi Arduini,
Jan Arlt,
Leonardo Badurina,
Antun Balaz,
Satvika Bandarupally,
Barry C Barish Michele Barone,
Michele Barsanti,
Steven Bass,
Angelo Bassi,
Baptiste Battelier,
Charles F. A. Baynham,
Quentin Beaufils,
Aleksandar Belic,
Joel Berge,
Jose Bernabeu,
Andrea Bertoldi,
Robert Bingham,
Sebastien Bize,
Diego Blas,
Kai Bongs,
Philippe Bouyer
, et al. (224 additional authors not shown)
Abstract:
We summarize the discussions at a virtual Community Workshop on Cold Atoms in Space concerning the status of cold atom technologies, the prospective scientific and societal opportunities offered by their deployment in space, and the developments needed before cold atoms could be operated in space. The cold atom technologies discussed include atomic clocks, quantum gravimeters and accelerometers, a…
▽ More
We summarize the discussions at a virtual Community Workshop on Cold Atoms in Space concerning the status of cold atom technologies, the prospective scientific and societal opportunities offered by their deployment in space, and the developments needed before cold atoms could be operated in space. The cold atom technologies discussed include atomic clocks, quantum gravimeters and accelerometers, and atom interferometers. Prospective applications include metrology, geodesy and measurement of terrestrial mass change due to, e.g., climate change, and fundamental science experiments such as tests of the equivalence principle, searches for dark matter, measurements of gravitational waves and tests of quantum mechanics. We review the current status of cold atom technologies and outline the requirements for their space qualification, including the development paths and the corresponding technical milestones, and identifying possible pathfinder missions to pave the way for missions to exploit the full potential of cold atoms in space. Finally, we present a first draft of a possible road-map for achieving these goals, that we propose for discussion by the interested cold atom, Earth Observation, fundamental physics and other prospective scientific user communities, together with ESA and national space and research funding agencies.
△ Less
Submitted 19 January, 2022;
originally announced January 2022.
-
Fundamental Physics with a State-of-the-Art Optical Clock in Space
Authors:
Andrei Derevianko,
Kurt Gibble,
Leo Hollberg,
Nathan R. Newbury,
Chris Oates,
Marianna S. Safronova,
Laura C. Sinclair,
Nan Yu
Abstract:
Recent advances in optical atomic clocks and optical time transfer have enabled new possibilities in precision metrology for both tests of fundamental physics and timing applications. Here we describe a space mission concept that would place a state-of-the-art optical atomic clock in an eccentric orbit around Earth. A high stability laser link would connect the relative time, range, and velocity o…
▽ More
Recent advances in optical atomic clocks and optical time transfer have enabled new possibilities in precision metrology for both tests of fundamental physics and timing applications. Here we describe a space mission concept that would place a state-of-the-art optical atomic clock in an eccentric orbit around Earth. A high stability laser link would connect the relative time, range, and velocity of the orbiting spacecraft to earthbound stations. The primary goal for this mission would be to test the gravitational redshift, a classical test of general relativity, with a sensitivity 30,000 times beyond current limits. Additional science objectives include other tests of relativity, enhanced searches for dark matter and drifts in fundamental constants, and establishing a high accuracy international time/geodesic reference.
△ Less
Submitted 20 December, 2021;
originally announced December 2021.
-
Narrow-line Cooling and Determination of Magic Wavelength of Cd
Authors:
A. Yamaguchi,
M. S. Safronova,
K. Gibble,
H. Katori
Abstract:
We experimentally and theoretically determine the magic wavelength of the (5$s^2$)$^{1}S_{0}$$-$(5$s$5$p$)$^{3}P_{0}$ clock transition of $^{111}$Cd to be 419.88(14) nm and 420.1(7) nm. To perform Lamb-Dicke spectroscopy of the clock transition, we use narrow-line laser cooling on the $^{1}S_{0}$$-$$^{3}P_{1}$ transition to cool the atoms to 6 $μ$K and load them into an optical lattice. Cadmium is…
▽ More
We experimentally and theoretically determine the magic wavelength of the (5$s^2$)$^{1}S_{0}$$-$(5$s$5$p$)$^{3}P_{0}$ clock transition of $^{111}$Cd to be 419.88(14) nm and 420.1(7) nm. To perform Lamb-Dicke spectroscopy of the clock transition, we use narrow-line laser cooling on the $^{1}S_{0}$$-$$^{3}P_{1}$ transition to cool the atoms to 6 $μ$K and load them into an optical lattice. Cadmium is an attractive candidate for optical lattice clocks because it has a small sensitivity to blackbody radiation and its efficient narrow-line cooling mitigates higher order light shifts. We calculate the blackbody shift, including the dynamic correction, to be fractionally 2.83(8)$\times$10$^{-16}$ at 300 K, an order of magnitude smaller than that of Sr and Yb. We also report calculations of the Cd $^1P_1$ lifetime and the ground state $C_6$ coefficient.
△ Less
Submitted 17 September, 2019;
originally announced September 2019.
-
Advances in the accuracy, stability, and reliability of the PTB primary fountain clocks
Authors:
S. Weyers,
V. Gerginov,
M. Kazda,
J. Rahm,
B. Lipphardt,
G. Dobrev,
K. Gibble
Abstract:
Improvements of the systematic uncertainty, frequency instability, and long-term reliability of the two caesium fountain primary frequency standards CSF1 and CSF2 at PTB (Physikalisch-Technische Bundesanstalt) are described. We have further investigated many of the systematic effects and made a number of modifications of the fountains. With an optically stabilized microwave oscillator, the quantum…
▽ More
Improvements of the systematic uncertainty, frequency instability, and long-term reliability of the two caesium fountain primary frequency standards CSF1 and CSF2 at PTB (Physikalisch-Technische Bundesanstalt) are described. We have further investigated many of the systematic effects and made a number of modifications of the fountains. With an optically stabilized microwave oscillator, the quantum projection noise limited frequency instabilities are improved to $7.2 \times 10^{-14} (τ/1\,\mathrm{s})^{-1/2}$ for CSF1 and $2.5 \times 10^{-14} (τ/1\,\mathrm{s})^{-1/2}$ for CSF2 at high atom density. The systematic uncertainties of CSF1 and CSF2 are reduced to $2.74 \times 10^{-16}$ and $1.71 \times 10^{-16}$, respectively. Both fountain clocks regularly calibrate the scale unit of International Atomic Time (TAI) and the local realization of Coordinated Universal Time, UTC(PTB), and serve as references to measure the frequencies of local and remote optical frequency standards.
△ Less
Submitted 10 September, 2018;
originally announced September 2018.
-
Atomic Clock Measurements of Quantum Scattering Phase Shifts Spanning Feshbach Resonances at Ultralow Fields
Authors:
Aaron Bennett,
Kurt Gibble,
Servaas Kokkelmans,
Jeremy M. Hutson
Abstract:
We use an atomic fountain clock to measure quantum scattering phase shifts precisely through a series of narrow, low-field Feshbach resonances at average collision energies below $1\,μ$K. Our low spread in collision energy yields phase variations of order $\pm π/2$ for target atoms in several $F,m_F$ states. We compare them to a theoretical model and establish the accuracy of the measurements and…
▽ More
We use an atomic fountain clock to measure quantum scattering phase shifts precisely through a series of narrow, low-field Feshbach resonances at average collision energies below $1\,μ$K. Our low spread in collision energy yields phase variations of order $\pm π/2$ for target atoms in several $F,m_F$ states. We compare them to a theoretical model and establish the accuracy of the measurements and the theoretical uncertainties from the fitted potential. We find overall excellent agreement, with small statistically significant differences that remain unexplained.
△ Less
Submitted 11 August, 2017;
originally announced August 2017.
-
Towards a Mg lattice clock: Observation of the $^1S_{0}-$$^3P_{0}$ transition and determination of the magic wavelength
Authors:
A. P. Kulosa,
D. Fim,
K. H. Zipfel,
S. Rühmann,
S. Sauer,
N. Jha,
K. Gibble,
W. Ertmer,
E. M. Rasel,
M. S. Safronova,
U. I. Safronova,
S. G. Porsev
Abstract:
We optically excite the electronic state $3s3p~^3P_{0}$ in $^{24}$Mg atoms, laser-cooled and trapped in a magic-wavelength lattice. An applied magnetic field enhances the coupling of the light to the otherwise strictly forbidden transition. We determine the magic wavelength, the quadratic magnetic Zeeman shift and the transition frequency to be 468.463(207)$\,$nm, -206.6(2.0)$\,$MHz/T$^2$ and 655…
▽ More
We optically excite the electronic state $3s3p~^3P_{0}$ in $^{24}$Mg atoms, laser-cooled and trapped in a magic-wavelength lattice. An applied magnetic field enhances the coupling of the light to the otherwise strictly forbidden transition. We determine the magic wavelength, the quadratic magnetic Zeeman shift and the transition frequency to be 468.463(207)$\,$nm, -206.6(2.0)$\,$MHz/T$^2$ and 655 058 646 691(101)$\,$kHz, respectively. These are compared with theoretical predictions and results from complementary experiments. We also developed a high-precision relativistic structure model for magnesium, give an improved theoretical value for the blackbody radiation shift and discuss a clock based on bosonic magnesium.
△ Less
Submitted 5 August, 2015;
originally announced August 2015.
-
Comment on "Frequency shifts in NIST Cs primary frequency standards due to transverse rf field gradients"
Authors:
Kurt Gibble
Abstract:
We discuss the theoretical treatment of the microwave lensing frequency shift of the NIST-F1 and F2 atomic fountain clocks by Ashby et al. [Phy. Rev. A. 91, 033624 (2015)]. The shifts calculated by NIST are much smaller than the previously evaluated microwave lensing frequency shifts of other clocks contributing to International Atomic Time. We identify several fundamental problems in the NIST tre…
▽ More
We discuss the theoretical treatment of the microwave lensing frequency shift of the NIST-F1 and F2 atomic fountain clocks by Ashby et al. [Phy. Rev. A. 91, 033624 (2015)]. The shifts calculated by NIST are much smaller than the previously evaluated microwave lensing frequency shifts of other clocks contributing to International Atomic Time. We identify several fundamental problems in the NIST treatment and demonstrate that each significantly affects their results. We also show a smooth transition of microwave lensing frequency shifts to the photon recoil shift for large wave packets.
△ Less
Submitted 4 May, 2015;
originally announced May 2015.
-
Comment on "first accuracy evaluation of NIST-F2"
Authors:
Kurt Gibble
Abstract:
We discuss the treatment of the systematic frequency shifts due to microwave lensing and distributed cavity phase in "First accuracy evaluation of NIST-F2" 2014 Metrologia 51 174-182. We explain that the microwave lensing frequency shift is generally non-zero and finite in the limit of no applied microwave field. This systematic error was incorrectly treated and we find that it contributes a signi…
▽ More
We discuss the treatment of the systematic frequency shifts due to microwave lensing and distributed cavity phase in "First accuracy evaluation of NIST-F2" 2014 Metrologia 51 174-182. We explain that the microwave lensing frequency shift is generally non-zero and finite in the limit of no applied microwave field. This systematic error was incorrectly treated and we find that it contributes a significant frequency offset. Accounting for this shift implies that the measured microwave amplitude dependence (e.g due to microwave leakage) is comparable to the total reported inaccuracy. We also discuss the importance of vertically aligning the fountain perpendicular to the axis of the cavity feeds, when the cavity has only two independent feeds. Finally, we note that background gas collisions have a different behavior for cold clock atoms than for clock atoms at room-temperature, and therefore room temperature measurements do not directly apply to laser-cooled clocks.
△ Less
Submitted 19 November, 2015; v1 submitted 4 May, 2015;
originally announced May 2015.
-
Scattering of Cold Atom Coherences by Hot Atoms: Frequency Shifts from Background Gas Collisions
Authors:
Kurt Gibble
Abstract:
Frequency shifts from background gas collisions currently contribute significantly to the inaccuracy of atomic clocks. Because nearly all collisions with room-temperature background gases that transfer momentum eject the cold atoms from the clock, the interference between the scattered and unscattered waves in the forward direction dominates these frequency shifts. We show they are ~10 times small…
▽ More
Frequency shifts from background gas collisions currently contribute significantly to the inaccuracy of atomic clocks. Because nearly all collisions with room-temperature background gases that transfer momentum eject the cold atoms from the clock, the interference between the scattered and unscattered waves in the forward direction dominates these frequency shifts. We show they are ~10 times smaller than in room-temperature clocks and that van der Waals interactions produce the cold-atom background-gas shift. General considerations allow the loss of Ramsey fringe amplitude to bound this frequency shift.
△ Less
Submitted 11 April, 2013;
originally announced April 2013.
-
S-Wave Collisional Frequency Shift of a Fermion Clock
Authors:
Eric L. Hazlett,
Yi Zhang,
Ronald W. Stites,
Kurt Gibble,
Kenneth M. O'Hara
Abstract:
We report an s-wave collisional frequency shift of an atomic clock based on fermions. In contrast to bosons, the fermion clock shift is insensitive to the population difference of the clock states, set by the first pulse area in Ramsey spectroscopy, θ_1. The fermion shift instead depends strongly on the second pulse area θ_2. It allows the shift to be canceled, nominally at θ_2 = π/2, but correlat…
▽ More
We report an s-wave collisional frequency shift of an atomic clock based on fermions. In contrast to bosons, the fermion clock shift is insensitive to the population difference of the clock states, set by the first pulse area in Ramsey spectroscopy, θ_1. The fermion shift instead depends strongly on the second pulse area θ_2. It allows the shift to be canceled, nominally at θ_2 = π/2, but correlations shift the null to slightly larger θ_2. The shift applies to optical lattice clocks and increases with the spatial inhomogeneity of the clock excitation field, naturally large at optical frequencies.
△ Less
Submitted 18 December, 2012;
originally announced December 2012.
-
Direct Observation of Resonant Scattering Phase Shifts and their Energy Dependence
Authors:
Stephen D. Gensemer,
Ross B. Martin-Wells,
Aaron W. Bennett,
Kurt Gibble
Abstract:
We scan the collision energy of two clouds of cesium atoms between 12 and 50 $μ$K in atomic fountain clock. By directly detecting the difference of s-wave scattering phase shifts, we observe a rapid variation of a scattering phase shift through a series of Feshbach resonances. At the energies we use, resonances that overlap at threshold become resolved. Our statistical phase uncertainty of 8 mrad…
▽ More
We scan the collision energy of two clouds of cesium atoms between 12 and 50 $μ$K in atomic fountain clock. By directly detecting the difference of s-wave scattering phase shifts, we observe a rapid variation of a scattering phase shift through a series of Feshbach resonances. At the energies we use, resonances that overlap at threshold become resolved. Our statistical phase uncertainty of 8 mrad can be improved in future precision measurements of Feshbach resonances to accurately determine the Cs-Cs interactions, which may provide stringent limits on the time variation of fundamental constants.
△ Less
Submitted 23 November, 2012;
originally announced November 2012.
-
Progress in Atomic Fountains at LNE-SYRTE
Authors:
Jocelyne Guéna,
Michel Abgrall,
Daniele Rovera,
Philippe Laurent,
Baptiste Chupin,
Michel Lours,
Giorgio Santarelli,
Peter Rosenbusch,
Michael E. Tobar,
Ruoxin Li,
Kurt Gibble,
André Clairon,
Sébastien Bize
Abstract:
We give an overview of the work done with the Laboratoire National de Métrologie et d'Essais-Systèmes de Référence Temps-Espace (LNE-SYRTE) fountain ensemble during the last five years. After a description of the clock ensemble, comprising three fountains, FO1, FO2, and FOM, and the newest developments, we review recent studies of several systematic frequency shifts. This includes the distributed…
▽ More
We give an overview of the work done with the Laboratoire National de Métrologie et d'Essais-Systèmes de Référence Temps-Espace (LNE-SYRTE) fountain ensemble during the last five years. After a description of the clock ensemble, comprising three fountains, FO1, FO2, and FOM, and the newest developments, we review recent studies of several systematic frequency shifts. This includes the distributed cavity phase shift, which we evaluate for the FO1 and FOM fountains, applying the techniques of our recent work on FO2. We also report calculations of the microwave lensing frequency shift for the three fountains, review the status of the blackbody radiation shift, and summarize recent experimental work to control microwave leakage and spurious phase perturbations. We give current accuracy budgets. We also describe several applications in time and frequency metrology: fountain comparisons, calibrations of the international atomic time, secondary representation of the SI second based on the 87Rb hyperfine frequency, absolute measurements of optical frequencies, tests of the T2L2 satellite laser link, and review fundamental physics applications of the LNE-SYRTE fountain ensemble. Finally, we give a summary of the tests of the PHARAO cold atom space clock performed using the FOM transportable fountain.
△ Less
Submitted 16 April, 2012;
originally announced April 2012.
-
Spin waves and Collisional Frequency Shifts of a Trapped-Atom Clock
Authors:
Wilfried Maineult,
Christian Deutsch,
Kurt Gibble,
Jakob Reichel,
Peter Rosenbusch
Abstract:
We excite spin-waves with spatially inhomogeneous pulses and study the resulting frequency shifts of a chip-scale atomic clock of trapped $^{87}$Rb. The density-dependent frequency shifts of the hyperfine transition simulate the s-wave collisional frequency shifts of fermions, including those of optical lattice clocks. As the spin polarizations oscillate in the trap, the frequency shift reverses a…
▽ More
We excite spin-waves with spatially inhomogeneous pulses and study the resulting frequency shifts of a chip-scale atomic clock of trapped $^{87}$Rb. The density-dependent frequency shifts of the hyperfine transition simulate the s-wave collisional frequency shifts of fermions, including those of optical lattice clocks. As the spin polarizations oscillate in the trap, the frequency shift reverses and it depends on the area of the second Ramsey pulse, exhibiting a predicted beyond mean-field frequency shift. Numerical and analytic models illustrate the observed behaviors.
△ Less
Submitted 4 July, 2012; v1 submitted 5 April, 2012;
originally announced April 2012.
-
Distributed cavity phase frequency shifts of the caesium fountain PTB-CSF2
Authors:
S. Weyers,
V. Gerginov,
N. Nemitz,
R. Li,
K. Gibble
Abstract:
We evaluate the frequency error from distributed cavity phase in the caesium fountain clock PTB-CSF2 at the Physikalisch-Technische Bundesanstalt with a combination of frequency measurements and ab initio calculations. The associated uncertainty is 1.3E-16, with a frequency bias of 0.4E-16. The agreement between the measurements and calculations explains the previously observed frequency shifts at…
▽ More
We evaluate the frequency error from distributed cavity phase in the caesium fountain clock PTB-CSF2 at the Physikalisch-Technische Bundesanstalt with a combination of frequency measurements and ab initio calculations. The associated uncertainty is 1.3E-16, with a frequency bias of 0.4E-16. The agreement between the measurements and calculations explains the previously observed frequency shifts at elevated microwave amplitude. We also evaluate the frequency bias and uncertainty due to the microwave lensing of the atomic wavepackets. We report a total PTB-CSF2 systematic uncertainty of 4.1E-16.
△ Less
Submitted 12 October, 2011;
originally announced October 2011.
-
Rydberg Spectroscopy in an Optical Lattice: Blackbody Thermometry for Atomic Clocks
Authors:
Vitali D. Ovsiannikov,
Andrei Derevianko,
Kurt Gibble
Abstract:
We show that optical spectroscopy of Rydberg states can provide accurate {\em in situ} thermometry at room-temperature. Transitions from a metastable state to Rydberg states with principal quantum numbers of 25 to 30 have 200 times larger fractional frequency sensitivities to blackbody radiation than the Strontium clock transition. We demonstrate that magic wavelength lattices exist for both Stron…
▽ More
We show that optical spectroscopy of Rydberg states can provide accurate {\em in situ} thermometry at room-temperature. Transitions from a metastable state to Rydberg states with principal quantum numbers of 25 to 30 have 200 times larger fractional frequency sensitivities to blackbody radiation than the Strontium clock transition. We demonstrate that magic wavelength lattices exist for both Strontium and Ytterbium transitions between the metastable and Rydberg states. Frequency measurements of Rydberg transitions with $10^{-16}$ accuracy provide $10 \, \mathrm{mK}$ resolution and yield a blackbody uncertainty for the clock transition of $10^{-18}$.
△ Less
Submitted 15 July, 2011;
originally announced July 2011.
-
Improved accuracy of the NPL-CsF2 primary frequency standard: evaluation of distributed cavity phase and microwave lensing frequency shifts
Authors:
Ruoxin Li,
Kurt Gibble,
Krzysztof Szymaniec
Abstract:
We evaluate the distributed cavity phase and microwave lensing frequency shifts, which were the two largest sources of uncertainty for the NPL-CsF2 cesium fountain clock. We report measurements that confirm a detailed theoretical model of the microwave cavity fields and the frequency shifts of the clock that they produce. The model and measurements significantly reduce the distributed cavity phase…
▽ More
We evaluate the distributed cavity phase and microwave lensing frequency shifts, which were the two largest sources of uncertainty for the NPL-CsF2 cesium fountain clock. We report measurements that confirm a detailed theoretical model of the microwave cavity fields and the frequency shifts of the clock that they produce. The model and measurements significantly reduce the distributed cavity phase uncertainty to $1.1 \times 10^{-16}$. We derive the microwave lensing frequency shift for a cylindrical cavity with circular apertures. An analytic result with reasonable approximations is given, in addition to a full calculation that indicates a shift of $6.2 \times 10^{-17}$. The measurements and theoretical models we report, along with improved evaluations of collisional and microwave leakage induced frequency shifts, reduce the frequency uncertainty of the NPL-CsF2 standard to $2.3 \times 10^{-16}$, nearly a factor of two lower than its most recent complete evaluation.
△ Less
Submitted 12 July, 2011;
originally announced July 2011.
-
Evaluation of Doppler Shifts to Improve the Accuracy of Primary Atomic Fountain Clocks
Authors:
Jocelyne Guéna,
Ruoxin Li,
Kurt Gibble,
Sébastien Bize,
André Clairon
Abstract:
We demonstrate agreement between measurements and ab initio calculations of the frequency shifts caused by distributed cavity phase variations in the microwave cavity of a primary atomic fountain clock. Experimental verification of the finite element models of the cavities gives the first quantitative evaluation of this leading uncertainty and allows it to be reduced to delta nu / nu = 8.4\times10…
▽ More
We demonstrate agreement between measurements and ab initio calculations of the frequency shifts caused by distributed cavity phase variations in the microwave cavity of a primary atomic fountain clock. Experimental verification of the finite element models of the cavities gives the first quantitative evaluation of this leading uncertainty and allows it to be reduced to delta nu / nu = 8.4\times10^-17. Applying these experimental techniques to clocks with improved microwave cavities will yield negligible distributed cavity phase uncertainties, less than \pm1\times10^-17.
△ Less
Submitted 8 March, 2011;
originally announced March 2011.
-
Evaluating and Minimizing Distributed Cavity Phase Errors in Atomic Clocks
Authors:
Ruoxin Li,
Kurt Gibble
Abstract:
We perform 3D finite element calculations of the fields in microwave cavities and analyze the distributed cavity phase errors of atomic clocks that they produce. The fields of cylindrical cavities are treated as an azimuthal Fourier series. Each of the lowest components produces clock errors with unique characteristics that must be assessed to establish a clock's accuracy. We describe the errors a…
▽ More
We perform 3D finite element calculations of the fields in microwave cavities and analyze the distributed cavity phase errors of atomic clocks that they produce. The fields of cylindrical cavities are treated as an azimuthal Fourier series. Each of the lowest components produces clock errors with unique characteristics that must be assessed to establish a clock's accuracy. We describe the errors and how to evaluate them. We prove that sharp structures in the cavity do not produce large frequency errors, even at moderately high powers, provided the atomic density varies slowly. We model the amplitude and phase imbalances of the feeds. For larger couplings, these can lead to increased phase errors. We show that phase imbalances produce a novel distributed cavity phase error that depends on the cavity detuning. We also design improved cavities by optimizing the geometry and tuning the mode spectrum so that there are negligible phase variations, allowing this source of systematic error to be dramatically reduced.
△ Less
Submitted 9 August, 2010;
originally announced August 2010.
-
Decoherence and Collisional Frequency Shifts of Trapped Bosons and Fermions
Authors:
Kurt Gibble
Abstract:
We perform exact calculations of collisional frequency shifts for several fermions or bosons using a singlet and triplet basis for pairs of particles. The "factor of 2 controversy" for bosons becomes clear - the factor is always 2. Decoherence is described by singlet states and they are unaffected by spatially uniform clock fields. Spatial variations are critical, especially for fermions which w…
▽ More
We perform exact calculations of collisional frequency shifts for several fermions or bosons using a singlet and triplet basis for pairs of particles. The "factor of 2 controversy" for bosons becomes clear - the factor is always 2. Decoherence is described by singlet states and they are unaffected by spatially uniform clock fields. Spatial variations are critical, especially for fermions which were previously thought to be immune to collision shifts. The spatial variations lead to decoherence and a novel frequency shift that is not proportional to the partial density of internal states.
△ Less
Submitted 14 September, 2009; v1 submitted 21 August, 2009;
originally announced August 2009.
-
A Quantum Scattering Interferometer
Authors:
Russell A. Hart,
Xinye Xu,
Ronald Legere,
Kurt Gibble
Abstract:
The collision of two ultra-cold atoms results in a quantum-mechanical superposition of two outcomes: each atom continues without scattering and each atom scatters as a spherically outgoing wave with an s-wave phase shift. The magnitude of the s-wave phase shift depends very sensitively on the interaction between the atoms. Quantum scattering and the underlying phase shifts are vitally important…
▽ More
The collision of two ultra-cold atoms results in a quantum-mechanical superposition of two outcomes: each atom continues without scattering and each atom scatters as a spherically outgoing wave with an s-wave phase shift. The magnitude of the s-wave phase shift depends very sensitively on the interaction between the atoms. Quantum scattering and the underlying phase shifts are vitally important in many areas of contemporary atomic physics, including Bose-Einstein condensates, degenerate Fermi gases, frequency shifts in atomic clocks, and magnetically-tuned Feshbach resonances. Precise measurements of quantum scattering phase shifts have not been possible until now because, in scattering experiments, the number of scattered atoms depends on the s-wave phase shifts as well as the atomic density, which cannot be measured precisely. Here we demonstrate a fundamentally new type of scattering experiment that interferometrically detects the quantum scattering phase shifts of individual atoms. By performing an atomic clock measurement using only the scattered part of each atom, we directly and precisely measure the difference of the s-wave phase shifts for the two clock states in a density independent manner. Our method will give the most direct and precise measurements of ultracold atom-atom interactions and will place stringent limits on the time variations of fundamental constants.
△ Less
Submitted 2 March, 2007; v1 submitted 14 February, 2007;
originally announced February 2007.