Skip to main content

Showing 1–9 of 9 results for author: Giardoni, M

.
  1. arXiv:1012.5511  [pdf, ps, other

    physics.ins-det hep-ex

    Study of gas purifiers for the CMS RPC detector

    Authors: L. Benussi, S. Bianco, S. Colafranceschi, F. L. Fabbri, F. Felli, M. Ferrini, M. Giardoni, T. Greci, A. Paolozzi, L. Passamonti, D. Piccolo, D. Pierluigi, A. Russo, G. Saviano, S. Buontempo, A. Cimmino, M. de Gruttola, F Fabozzi d A. O. M. Iorio, L. Lista, P. Paolucci, P. Baesso, G. Belli, D. Pagano, S. P. Ratti, A. Vicini , et al. (4 additional authors not shown)

    Abstract: The CMS RPC muon detector utilizes a gas recirculation system called closed loop (CL) to cope with large gas mixture volumes and costs. A systematic study of CL gas purifiers has been carried out over 400 days between July 2008 and August 2009 at CERN in a low-radiation test area, with the use of RPC chambers with currents monitoring, and gas analysis sampling points. The study aimed to fully clar… ▽ More

    Submitted 26 December, 2010; originally announced December 2010.

  2. arXiv:1012.5508  [pdf, ps, other

    physics.ins-det hep-ex

    A new approach in modeling the response of RPC detectors

    Authors: L. Benussi, S. Bianco, S. Colafranceschi, F. L. Fabbri, M. Giardoni, L. Passamonti, D. Piccolo, D. Pierluigi, A. Russo, G. Saviano, S. Buontempo, A. Cimmino, M. de Gruttola, F Fabozzi, A. O. M. Iorio, L. Lista, P. Paolucci, P. Baesso, G. Belli, D. Pagano, S. P. Ratti, A. Vicini, P. Vitulo, C. Viviani, A. Sharma , et al. (1 additional authors not shown)

    Abstract: The response of RPC detectors is highly sensitive to environmental variables. A novel approach is presented to model the response of RPC detectors in a variety of experimental conditions. The algorithm, based on Artificial Neural Networks, has been developed and tested on the CMS RPC gas gain monitoring system during commissioning.

    Submitted 26 December, 2010; originally announced December 2010.

  3. Sensitivity and environmental response of the CMS RPC gas gain monitoring system

    Authors: L. Benussi, S. Bianco, S. Colafranceschi, F. L. Fabbri, M. Giardoni, B. Ortenzi, A. Paolozzi, L. Passamonti, D. Pierluigi, B. Ponzio, A. Russo, A. Colaleo, F. Loddo, M. Maggi, A. Ranieri, M. Abbrescia, G. Iaselli, B. Marangelli, S. Natali, S. Nuzzo, G. Pugliese, F. Romano, G. Roselli, R. Trentadue, S. Tupputi , et al. (13 additional authors not shown)

    Abstract: Results from the gas gain monitoring (GGM) system for the muon detector using RPC in the CMS experiment at the LHC is presented. The system is designed to provide fast and accurate determination of any shift in the working point of the chambers due to gas mixture changes.

    Submitted 9 December, 2008; originally announced December 2008.

    Comments: 8 pages, 7 figures, uses lnfprepCMS.sty, presented by S. Colafranceschi at IEEE 08 Dresden (Germany) November 2008

    Report number: Frascati Preprint LNF - 08 / 27(P)

    Journal ref: JINST 4:P08006,2009

  4. The CMS RPC gas gain monitoring system: an overview and preliminary results

    Authors: L. Benussi, S. Bianco, S. Colafranceschi, D. Colonna, L. Daniello, F. L. Fabbri, M. Giardoni, B. Ortenzi, A. Paolozzi, L. Passamonti, D. Pierluigi, B. Ponzio, C. Pucci, A. Russo, G. Roselli, A. Colaleo, F. Loddo, M. Maggi, A. Ranieri, M. Abbrescia, G. Iaselli, B. Marangelli, S. Natali, S. Nuzzo, G. Pugliese , et al. (18 additional authors not shown)

    Abstract: The status of the CMS RPC Gas Gain Monitoring (GGM) system developed at the Frascati Laboratory of INFN (Istituto Nazionale di Fisica Nucleare) is reported on. The GGM system is a cosmic ray telescope based on small RPC detectors operated with the same gas mixture used by the CMS RPC system. The GGM gain and efficiency are continuously monitored on-line, thus providing a fast and accurate determ… ▽ More

    Submitted 5 December, 2008; originally announced December 2008.

    Comments: 8 pages, 9 figures, uses lnfprepCMS.sty, presented by L. Benussi at RPC07, Mumbai, INDIA 2008

    Report number: Frascati PrePrint LNF-08/29(P)

    Journal ref: Nucl.Instrum.Meth.A602:805-808,2009

  5. A Novel Approach for an Integrated Straw tube-Microstrip Detector

    Authors: E. Basile, F. Bellucci, L. Benussi, M. Bertani, S. Bianco, M. A. Caponero, D. Colonna, F. Di Falco, F. L. Fabbri, F. Felli, M. Giardoni, A. La Monaca, G. Mensitieri, B. Ortenzi, M. Pallotta, A. Paolozzi, L. Passamonti, D. Pierluigi, C. Pucci, A. Russo, G. Saviano, F. Massa, F. Casali, M. Bettuzzi, D. Bianconi F. Baruffaldi , et al. (1 additional authors not shown)

    Abstract: We report on a novel concept of silicon microstrips and straw tubes detector, where integration is accomplished by a straw module with straws not subjected to mechanical tension in a Rohacell $^{\circledR}$ lattice and carbon fiber reinforced plastic shell. Results on mechanical and test beam performances are reported on as well.

    Submitted 28 December, 2005; originally announced December 2005.

    Comments: Accepted by Transactions on Nuclear Science (2005). 11 pages, 9 figures, uses lnfprep.sty

    Report number: LNF-05/32(P)

    Journal ref: IEEE Trans.Nucl.Sci. 53 (2006) 1375-1379

  6. Two- and Three-Dimensional Reconstruction and Analysis of the Straw Tubes Tomography in the Btev Experiment

    Authors: E. Basile, F. Bellucci, L. Benussi, M. Bertani, S. Bianco, M. A. Caponero, D. Colonna, F. Di Falco, F. L. Fabbri, F. Felli, M. Giardoni, A. La Monaca, F. Massa, G. Mensitieri, B. Ortenzi, M. Pallotta, A. Paolozzi, L. Passamonti, D. Pierluigi, C. Pucci, A. Russo, G. Saviano F. Casali, M. Bettuzzi, D. Bianconi

    Abstract: A check of the eccentricity of the aluminised kapton straw tubes used in the BTeV experiment is accomplished using X-ray tomography of the section of tubes modules. 2 and 3-dimensional images of the single tubes and of the modules are reconstructed and analysed. Preliminary results show that a precision better than 40 $μ$m can be reached on the measurement of the straw radii.

    Submitted 28 December, 2005; originally announced December 2005.

    Comments: Presented by F.Massa at ICATPP05, Villa Olmo (Como) Italy, November 2005. 4 pages, 8 figures, uses lnfprep.sty

    Report number: LNF-05/31(P)

  7. Micrometric Position Monitoring Using Fiber Bragg Grating Sensors in Silicon Detectors

    Authors: E. Basile, F. Bellucci, L. Benussi, M. Bertani, S. Bianco, M. A. Caponero, D. Colonna, F. Di Falco, F. L. Fabbri, F. Felli, M. Giardoni, A. La Monaca, F. Massa, G. Mensitieri, B. Ortenzi, M. Pallotta, A. Paolozzi, L. Passamonti, D. Pierluigi, C. Pucci, A. Russo, G. Saviano

    Abstract: We show R&D results including long term stability, resolution, radiation hardness and characterization of Fiber Grating sensors used to monitor structure deformation, repositioning and surveying of silicon detector in High Energy Physics.

    Submitted 28 December, 2005; originally announced December 2005.

    Comments: Presented by S.Bianco at ICATPP05, Villa Olmo (Como) Italy, November 2005. 5 pages, 6 figures, uses lnfprep.sty

    Report number: LNF-05/30(P)

  8. arXiv:physics/0412100  [pdf, ps, other

    physics.ins-det

    An Uncoventional Approach for a Straw Tube-Microstrip Detector

    Authors: E. Basile, F. Bellucci, L. Benussi, M. Bertani, S. Bianco, M. A. Caponero, D. Colonna, F. Di Falco, F. L. Fabbri, F. Felli, M. Giardoni, A. La Monaca, G. Mensitieri, B. Ortenzi, M. Pallotta, A. Paolozzi, L. Passamonti, D. Pierluigi, C. Pucci, A. Russo, G. Saviano, S. Tomassini

    Abstract: We report on a novel concept of silicon microstrips and straw tubes detector, where integration is accomplished by a straw module with straws not subjected to mechanical tension in a Rohacell lattice and carbon fiber reinforced plastic shell. Results on mechanical and test beam performances are reported on as well.

    Submitted 16 December, 2004; originally announced December 2004.

    Comments: 8 pages, 7 figures uses an lnfprep.sty

    Report number: LNF-04/25 (P)

  9. arXiv:hep-ex/9912066  [pdf, ps, other

    hep-ex

    The upgraded Outer em calorimeter of FOCUS at Fermilab

    Authors: S. Bianco, F. L. Fabbri, M. Giardoni, L. Passamonti, V. Russo, S. Sarwar, A. Zallo, S. Carrillo, H. Mendez, G. Gianini, J. Anjos, I. Bediaga, C. Gobel, A. Laudo, J. Magnin, J. Miranda, I. Pepe, F. Simao, A. Sanchez, A. Reis

    Abstract: Operational performance, algorithms, stability and physics results of the Outer em calorimeter of FOCUS are overviewed.

    Submitted 30 December, 1999; originally announced December 1999.

    Comments: 17 pages, 11 figures, uses Frascati preprint style. Presented by F. L. Fabbri at the VIII International Conference on Calorimetry in HEP, June 13-19, 1999, Lisbon (Portugal)

    Report number: LNF-99/033(P)