Frequency response limitation of heat flux meters
Authors:
I. Naveros,
Christian Ghiaus,
D. P. Ruíz
Abstract:
Heat flux meters are used for measuring the heat flux densities going through walls, usually at quasi-steady state. The limitations of heat flux meters under dynamic conditions are well documented in the literature; nonetheless there is a theoretical limitation which is mostly not considered and should be also taken into account. Since heat transfer is a dissipative process, it would be expected t…
▽ More
Heat flux meters are used for measuring the heat flux densities going through walls, usually at quasi-steady state. The limitations of heat flux meters under dynamic conditions are well documented in the literature; nonetheless there is a theoretical limitation which is mostly not considered and should be also taken into account. Since heat transfer is a dissipative process, it would be expected to obtain transfer functions which act as low pass filters. Nonetheless, this paper shows that the transfer functions modeling heat flow rate may become high pass filters, which is against the physical evidence. In order to show this theoretical limitation of the heat flux meters, the heat equation is transformed in different classes of models, from partial differential equations to transfer functions related to surface temperatures and heat flux density going through a wall.
△ Less
Submitted 6 May, 2024;
originally announced June 2024.
-
Causality issue in the heat balance method for calculating the design heating and cooling load
Authors:
Christian Ghiaus
Abstract:
Heating and cooling load calculation based on dynamic models is widely used in simulation software and it is the method recommended by ASHRAE and CEN. The principle is to make the heat balance for the air volume of a room space considered at uniform temperature and to calculate from this equation the load, i.e. the power needed to obtain the required indoor temperature. The problem is that, by doi…
▽ More
Heating and cooling load calculation based on dynamic models is widely used in simulation software and it is the method recommended by ASHRAE and CEN. The principle is to make the heat balance for the air volume of a room space considered at uniform temperature and to calculate from this equation the load, i.e. the power needed to obtain the required indoor temperature. The problem is that, by doing so, the physical causality is not respected. If the model is approximated by a piecewise linear dynamical system, this procedure results in an improper transfer function. In order to point out this problem, a method to obtain state space and transfer function models from thermal networks is introduced. Then, the transfer function representation is employed to show that changing the physical causality results in an improper transfer function. The practical consequence is that when the space temperature has a step variation, the calculated load tends to infinity if the simulation time step tends to zero. The issue of causality may be a problem in equation-based simulation software, such as MODELICA, in which the equations do not represent causal relations: a wrong choice of the causality in a balance equation may result in improper transfer functions.
△ Less
Submitted 14 March, 2022;
originally announced March 2022.
-
Thermal circuits assembling and state-space extraction for modelling heat transfer in buildings
Authors:
Christian Ghiaus,
Naveed Ahmad
Abstract:
State-space representation is essential in the theory of dynamic systems. This paper introduces a methodology for obtaining state-space representation from the thermal models of elementary components of a building by the conjunction of two methods: 1) assembling of thermal circuits and 2) state-space extraction from thermal circuit. These methods are fully illustrated on a very simple model and te…
▽ More
State-space representation is essential in the theory of dynamic systems. This paper introduces a methodology for obtaining state-space representation from the thermal models of elementary components of a building by the conjunction of two methods: 1) assembling of thermal circuits and 2) state-space extraction from thermal circuit. These methods are fully illustrated on a very simple model and tested on a real house of about 100 m 2 on which detailed measurements were achieved for 40 days at a time step of 10 min. The errors obtained between the measurements and the simulation results are in the order of $\pm$1 {\textdegree}C for a single zone and $\pm$2 {\textdegree}C for seven thermal zones. Besides simulation, parameter identification and control, the methods for assembling thermal circuits and extraction of state-space representation may be useful in Building Information Modelling (BIM).
△ Less
Submitted 8 March, 2022;
originally announced March 2022.
-
An efficient Bayesian experimental calibration of dynamic thermal models
Authors:
L. Raillon,
Christian Ghiaus
Abstract:
Experimental calibration of dynamic thermal models is required for model predictive control and characterization of building energy performance. In these applications, the uncertainty assessment of the parameter estimates is decisive; this is why a Bayesian calibration procedure (selection, calibration and validation) is presented. The calibration is based on an improved Metropolis-Hastings algori…
▽ More
Experimental calibration of dynamic thermal models is required for model predictive control and characterization of building energy performance. In these applications, the uncertainty assessment of the parameter estimates is decisive; this is why a Bayesian calibration procedure (selection, calibration and validation) is presented. The calibration is based on an improved Metropolis-Hastings algorithm suitable for linear and Gaussian state-space models. The procedure, illustrated on a real house experiment, shows that the algorithm is more robust to initial conditions than a maximum likelihood optimization with a quasi-Newton algorithm. Furthermore, when the data are not informative enough, the use of prior distributions helps to regularize the problem.
△ Less
Submitted 12 April, 2019;
originally announced April 2019.
-
Design of experiments for Quick U-building method for building energy performance measurement
Authors:
Christian Ghiaus,
Florent Alzetto
Abstract:
Quick U-building (QUB) is a method for short time measurement of energy performance of buildings, typically one night. It uses the indoor air temperature response to power delivered to the indoor air by electric heaters. This paper introduces a method for estimating the expected measurement error as a function of the amplitude and the time duration of the input signal based on the decomposition of…
▽ More
Quick U-building (QUB) is a method for short time measurement of energy performance of buildings, typically one night. It uses the indoor air temperature response to power delivered to the indoor air by electric heaters. This paper introduces a method for estimating the expected measurement error as a function of the amplitude and the time duration of the input signal based on the decomposition of the time response of a state-space model into a sum of exponentials by using the eigenvalues of the state matrix. It is shown that the buildings have a group of dominant time constants, which gives an exponential response, and many very short and very large time constants, which have a small influence on the response. The analysis of the eigenvalues demonstrates that the QUB experiment may be done in a rather short time as compared with the largest time constant of the building.
△ Less
Submitted 16 April, 2019;
originally announced April 2019.