-
Diffeomorphic Transformer-based Abdomen MRI-CT Deformable Image Registration
Authors:
Yang Lei,
Luke A. Matkovic,
Justin Roper,
Tonghe Wang,
Jun Zhou,
Beth Ghavidel,
Mark McDonald,
Pretesh Patel,
Xiaofeng Yang
Abstract:
This paper aims to create a deep learning framework that can estimate the deformation vector field (DVF) for directly registering abdominal MRI-CT images. The proposed method assumed a diffeomorphic deformation. By using topology-preserved deformation features extracted from the probabilistic diffeomorphic registration model, abdominal motion can be accurately obtained and utilized for DVF estimat…
▽ More
This paper aims to create a deep learning framework that can estimate the deformation vector field (DVF) for directly registering abdominal MRI-CT images. The proposed method assumed a diffeomorphic deformation. By using topology-preserved deformation features extracted from the probabilistic diffeomorphic registration model, abdominal motion can be accurately obtained and utilized for DVF estimation. The model integrated Swin transformers, which have demonstrated superior performance in motion tracking, into the convolutional neural network (CNN) for deformation feature extraction. The model was optimized using a cross-modality image similarity loss and a surface matching loss. To compute the image loss, a modality-independent neighborhood descriptor (MIND) was used between the deformed MRI and CT images. The surface matching loss was determined by measuring the distance between the warped coordinates of the surfaces of contoured structures on the MRI and CT images. The deformed MRI image was assessed against the CT image using the target registration error (TRE), Dice similarity coefficient (DSC), and mean surface distance (MSD) between the deformed contours of the MRI image and manual contours of the CT image. When compared to only rigid registration, DIR with the proposed method resulted in an increase of the mean DSC values of the liver and portal vein from 0.850 and 0.628 to 0.903 and 0.763, a decrease of the mean MSD of the liver from 7.216 mm to 3.232 mm, and a decrease of the TRE from 26.238 mm to 8.492 mm. The proposed deformable image registration method based on a diffeomorphic transformer provides an effective and efficient way to generate an accurate DVF from an MRI-CT image pair of the abdomen. It could be utilized in the current treatment planning workflow for liver radiotherapy.
△ Less
Submitted 4 May, 2024;
originally announced May 2024.
-
Dual-Energy Cone-Beam CT Using Two Complementary Limited-Angle Scans with A Projection-Consistent Diffusion Model
Authors:
Junbo Peng,
Chih-Wei Chang,
Richard L. J. Qiu,
Tonghe Wang,
Justin Roper,
Beth Ghavidel,
Xiangyang Tang,
Xiaofeng Yang
Abstract:
Background: Dual-energy imaging on cone-beam CT (CBCT) scanners has great potential in different clinical applications, including image-guided surgery and adaptive proton therapy. However, the clinical practice of dual-energy CBCT (DE-CBCT) has been hindered by the requirement of sophisticated hardware components. Purpose: In this work, we aim to propose a practical solution for single-scan dual-e…
▽ More
Background: Dual-energy imaging on cone-beam CT (CBCT) scanners has great potential in different clinical applications, including image-guided surgery and adaptive proton therapy. However, the clinical practice of dual-energy CBCT (DE-CBCT) has been hindered by the requirement of sophisticated hardware components. Purpose: In this work, we aim to propose a practical solution for single-scan dual-energy imaging on current CBCT scanners without hardware modifications, using two complementary limited-angle scans with a projection-consistent diffusion model. Methods: Our approach has two major components: data acquisition using two complementary limited-angle scans, and dual-energy projections restoration with subsequent FDK reconstruction. Two complementary scans at different kVps are performed in a single rotation by switching the tube voltage at the middle of the source trajectory, acquiring the mixed-spectra projection in a single CBCT scan. Full-sampled dual-energy projections are then restored by a projection-consistent diffusion model in a slice-by-slice manner, followed by the DE-CBCT reconstruction using the FDK algorithm. Results: The proposed method was evaluated in a simulation study of digital abdomen phantoms and a study of real rat data. In the simulation study, the proposed method produced DE-CBCT images at a mean absolute error (MAE) of 20 HU. In the small-animal study, reconstructed DE-CBCT images using the proposed method gave an MAE of 25 HU. Conclusion: This study demonstrates the feasibility of DE-CBCT imaging using two complementary limited-angle scans with a projection-consistent diffusion model in both half-fan and short scans. The proposed method may allow quantitative applications of DE-CBCT and enable DE-CBCT-based adaptive proton therapy.
△ Less
Submitted 18 March, 2024;
originally announced March 2024.
-
Learning-Based Synthetic Dual Energy CT Imaging from Single Energy CT for Stop** Power Ratio Calculation in Proton Radiation Therapy
Authors:
Serdar Charyyev,
Tonghe Wang,
Yang Lei,
Beth Ghavidel,
Jonathan J. Beitler,
Mark McDonald,
Walter J. Curran,
Tian Liu,
Jun Zhou,
Xiaofeng Yang
Abstract:
Purpose: Dual-energy CT (DECT) has been shown to derive stop** power ratio (SPR) map with higher accuracy than conventional single energy CT (SECT) by obtaining the energy dependence of photon interactions. However, DECT is not as widely implemented as SECT in proton radiation therapy simulation. This work presents a learning-based method to synthetize DECT images from SECT for proton radiation…
▽ More
Purpose: Dual-energy CT (DECT) has been shown to derive stop** power ratio (SPR) map with higher accuracy than conventional single energy CT (SECT) by obtaining the energy dependence of photon interactions. However, DECT is not as widely implemented as SECT in proton radiation therapy simulation. This work presents a learning-based method to synthetize DECT images from SECT for proton radiation therapy. Methods: The proposed method uses a residual attention generative adversarial network. Residual blocks with attention gates were used to force the model focus on the difference between DECT maps and SECT images. To evaluate the accuracy of the method, we retrospectively investigated 20 head-and-neck cancer patients with both DECT and SECT scans available. The high and low energy CT images acquired from DECT acted as learning targets in the training process for SECT datasets and were evaluated against results from the proposed method using a leave-one-out cross-validation strategy. To evaluate our method in the context of a practical application, we generated SPR maps from sDECT using physics-based dual-energy stoichiometric method and compared the maps to those generated from DECT. Results: The synthesized DECT images showed an average mean absolute error around 30 Hounsfield Unit (HU) across the whole-body volume. The corresponding SPR maps generated from synthetic DECT showed an average normalized mean square error of about 1% with reduced noise level and artifacts than those from original DECT. Conclusions: The accuracy of the synthesized DECT image by our machine-learning-based method was evaluated on head and neck patient, and potential feasibility for proton treatment planning and dose calculation was shown by generating SPR map using the synthesized DECT.
△ Less
Submitted 25 May, 2020;
originally announced May 2020.
-
Learning-Based Stop** Power Map** on Dual Energy CT for Proton Radiation Therapy
Authors:
Tonghe Wang,
Yang Lei,
Joseph Harms,
Beth Ghavidel,
Liyong Lin,
Jonathan J. Beitler,
Mark McDonald,
Walter J. Curran,
Tian Liu,
Jun Zhou,
Xiaofeng Yang
Abstract:
Purpose: Dual-energy CT (DECT) has been used to derive relative stop** power (RSP) map by obtaining the energy dependence of photon interactions. The DECT-derived RSP maps could potentially be compromised by image noise levels and the severity of artifacts when using physics-based map** techniques, which would affect subsequent clinical applications. This work presents a noise-robust learning-…
▽ More
Purpose: Dual-energy CT (DECT) has been used to derive relative stop** power (RSP) map by obtaining the energy dependence of photon interactions. The DECT-derived RSP maps could potentially be compromised by image noise levels and the severity of artifacts when using physics-based map** techniques, which would affect subsequent clinical applications. This work presents a noise-robust learning-based method to predict RSP maps from DECT for proton radiation therapy. Methods: The proposed method uses a residual attention cycle-consistent generative adversarial (CycleGAN) network. CycleGAN were used to let the DECT-to-RSP map** be close to a one-to-one map** by introducing an inverse RSP-to-DECT map**. We retrospectively investigated 20 head-and-neck cancer patients with DECT scans in proton radiation therapy simulation. Ground truth RSP values were assigned by calculation based on chemical compositions, and acted as learning targets in the training process for DECT datasets, and were evaluated against results from the proposed method using a leave-one-out cross-validation strategy. Results: The predicted RSP maps showed an average normalized mean square error (NMSE) of 2.83% across the whole body volume, and average mean error (ME) less than 3% in all volumes of interest (VOIs). With additional simulated noise added in DECT datasets, the proposed method still maintained a comparable performance, while the physics-based stoichiometric method suffered degraded inaccuracy from increased noise level. The average differences in DVH metrics for clinical target volumes (CTVs) were less than 0.2 Gy for D95% and Dmax with no statistical significance. Conclusion: These results strongly indicate the high accuracy of RSP maps predicted by our machine-learning-based method and show its potential feasibility for proton treatment planning and dose calculation.
△ Less
Submitted 19 March, 2020;
originally announced March 2020.