-
A Vacuum-Compatible Cylindrical Inertial Rotation Sensor with Picoradian Sensitivity
Authors:
M. P. Ross,
J. van Dongen,
Y. Huang,
P. Zhou,
Y. Chowdhury,
S. K. Apple,
C. M. Mow-Lowry,
A. L. Mitchell,
N. A. Holland,
B. Lantz,
E. Bonilla,
A. Engl,
A. Pele,
D. Griffith,
E. Sanchez,
E. A. Shaw,
C. Gettings,
J. H. Gundlach
Abstract:
We describe an inertial rotation sensor with a 30-cm cylindrical proof-mass suspended from a pair of 14-$μ$m thick BeCu flexures. The angle between the proof-mass and support structure is measured with a pair of homodyne interferometers which achieve a noise level of $\sim 5\ \text{prad}/\sqrt{\text{Hz}}$. The sensor is entirely made of vacuum compatible materials and the center of mass can be adj…
▽ More
We describe an inertial rotation sensor with a 30-cm cylindrical proof-mass suspended from a pair of 14-$μ$m thick BeCu flexures. The angle between the proof-mass and support structure is measured with a pair of homodyne interferometers which achieve a noise level of $\sim 5\ \text{prad}/\sqrt{\text{Hz}}$. The sensor is entirely made of vacuum compatible materials and the center of mass can be adjusted remotely.
△ Less
Submitted 14 September, 2023; v1 submitted 11 July, 2023;
originally announced July 2023.
-
A Pseudo Plane-wave Gravitational Calibrator for Gravitational Wave Observatories
Authors:
M. P. Ross,
J. H. Gundlach,
E. G. Adelberger,
C. M. Weller,
E. A. Shaw,
C. Gettings,
J. Kissel,
T. Mistry,
L. Datrier,
E. Daw,
M. Hendry
Abstract:
The precisions of existing gravitational calibrators for gravitational wave observatories are limited by their dependence on the relative position between the calibrators and the observatory's test masses. Here we present a novel geometry consisting of four quadrupole rotors placed at the vertices of a rectangle centered on the test mass. The phases and rotation directions are selected to produce…
▽ More
The precisions of existing gravitational calibrators for gravitational wave observatories are limited by their dependence on the relative position between the calibrators and the observatory's test masses. Here we present a novel geometry consisting of four quadrupole rotors placed at the vertices of a rectangle centered on the test mass. The phases and rotation directions are selected to produce a pseudo plane-wave sinusoidal gravitational acceleration with amplitude of ~ 100 fm/s^2. We show that this acceleration only has minimal dependence on the test mass position relative to the rotor array and can yield 0.15% acceleration amplitude uncertainty while tolerating a 1-cm test mass position uncertainty. The acceleration can be directed precisely along the optical axis of the interferometer arm and applies no torque on the test mass. In addition, the small size of the rotors has significant engineering and safety benefits.
△ Less
Submitted 25 January, 2023;
originally announced January 2023.
-
An Interactive Gravitational-Wave Detector Model for Museums and Fairs
Authors:
S. J. Cooper,
A. C. Green,
H. R. Middleton,
C. P. L. Berry,
R. Buscicchio,
E. Butler,
C. J. Collins,
C. Gettings,
D. Hoyland,
A. W. Jones,
J. H. Lindon,
I. Romero-Shaw,
S. P. Stevenson,
E. P. Takeva,
S. Vinciguerra,
A. Vecchio,
C. M. Mow-Lowry,
A. Freise
Abstract:
In 2015 the first observation of gravitational waves marked a breakthrough in astrophysics, and in technological research and development. The discovery of a gravitational-wave signal from the collision of two black holes, a billion light-years away, received considerable interest from the media and public. We describe the development of a purpose-built exhibit explaining this new area of research…
▽ More
In 2015 the first observation of gravitational waves marked a breakthrough in astrophysics, and in technological research and development. The discovery of a gravitational-wave signal from the collision of two black holes, a billion light-years away, received considerable interest from the media and public. We describe the development of a purpose-built exhibit explaining this new area of research to a general audience. The core element of the exhibit is a working Michelson interferometer: a scaled-down version of the key technology used in gravitational-wave detectors. The Michelson interferometer is integrated into a hands-on exhibit, which allows for user interaction and simulated gravitational-wave observations. An interactive display provides a self-guided explanation of gravitational-wave-related topics through video, animation, images and text. We detail the hardware and software used to create the exhibit and discuss two installation variants: an independent learning experience in a museum setting (the Thinktank Birmingham Science Museum), and a science-festival with the presence of expert guides (the 2017 Royal Society Summer Science Exhibition). We assess audience reception in these two settings, describe the improvements we have made given this information, and discuss future public-engagement projects resulting from this work. The exhibit is found to be effective in communicating the new and unfamiliar field of gravitational-wave research to general audiences. An accompanying website provides parts lists and information for others to build their own version of this exhibit.
△ Less
Submitted 6 August, 2021; v1 submitted 6 April, 2020;
originally announced April 2020.
-
An Air Suspension to Demonstrate the Properties of Torsion Balances with Fibres of Zero Length
Authors:
C. Gettings,
C. C. Speake
Abstract:
We report on the design and characterisation of an air-bearing suspension that has been constructed to highlight the properties of torsion balances with fibres of zero length. A float is levitated on this suspension and its rotational and translational motion in the horizontal plane of the laboratory is controlled using magnetic actuators. We demonstrate the in-situ electromagnetic tuning of the f…
▽ More
We report on the design and characterisation of an air-bearing suspension that has been constructed to highlight the properties of torsion balances with fibres of zero length. A float is levitated on this suspension and its rotational and translational motion in the horizontal plane of the laboratory is controlled using magnetic actuators. We demonstrate the in-situ electromagnetic tuning of the float's centre-of-buoyancy to an accuracy of $\pm$0.3 mm, which was limited by the noise in the air bearing. The rotational stiffness of the float, which is approximately zero by design, was also measured. We compare the observed behaviour of the float with the predictions of a detailed model of the statics of the float-actuator system. Finally, we briefly discuss the application of these ideas and results to the construction of sensitive devices for the measurement of weak forces with short ranges.
△ Less
Submitted 10 February, 2020;
originally announced February 2020.
-
A Method for Reducing the Adverse Effects of Stray-Capacitance on Capacitive Sensor Circuits
Authors:
Conner Gettings,
Clive C. Speake
Abstract:
We examine the increase in voltage noise in capacitive sensor circuits due to the stray-capacitance introduced by connecting cables. We have measured and modelled the voltage noise of various standard circuits, and we compare their performance against a benchmark without stray-capacitance that is optimised to have a high signal-to-noise ratio (SNR) for our application. We show that a factor limiti…
▽ More
We examine the increase in voltage noise in capacitive sensor circuits due to the stray-capacitance introduced by connecting cables. We have measured and modelled the voltage noise of various standard circuits, and we compare their performance against a benchmark without stray-capacitance that is optimised to have a high signal-to-noise ratio (SNR) for our application. We show that a factor limiting sensitivity is the so-called noise gain, which is not easily avoided. In our application the capacitive sensor is located in a metallic vessel and is therefore shielded to some extent from ambient noise at radio frequencies. It is therefore possible to compromise the shielding of the coaxial connecting cable by effectively electrically floating it. With a cable stray-capacitance of 1.8nF and at a modulation frequency of 100kHz, our circuit has an output voltage noise a factor of 3 larger than the benchmark.
△ Less
Submitted 16 December, 2019;
originally announced December 2019.