Gamma dose rate monitoring using a Silicon Photomultiplier-based plastic scintillation detector
Authors:
Paolo Tancioni,
Ulisse Gendotti
Abstract:
Plastic scintillation detectors represent an efficient, cost-effective, customizable solution for assessment of gamma radiation fields in the context of nuclear security, environmental radiation survey, radiological and nuclear incidents response (RNe) and dosimetry for radiation protection purposes. Solid state light readout technologies such as Silicon Photomultiplier diodes (SiPM) are character…
▽ More
Plastic scintillation detectors represent an efficient, cost-effective, customizable solution for assessment of gamma radiation fields in the context of nuclear security, environmental radiation survey, radiological and nuclear incidents response (RNe) and dosimetry for radiation protection purposes. Solid state light readout technologies such as Silicon Photomultiplier diodes (SiPM) are characterized by low operational voltage, mechanical robustness, compact dimensions, and fast pulse rise-time. Due to these intrinsic advantages, Silicon Photomultiplier diodes have been progressively replacing Photomultiplier Tube-based gamma detection technologies in a great part of these applications. In this experimental study, a gamma energy calibration and a dose rate calculation algorithm are discussed and implemented onto the SiPM-based Flat Panel Gamma detector (FPG) developed by Arktis Radiation Detectors Ltd (Zurich, Switzerland). The FPG detector has been deployed and studied in the framework of research projects on RNe technologies, involving its use on unmanned aerial and ground vehicle such as drones and robots. This work moved from the need for end users to have an accurate and reliable dose rate assessment when operating in the field, especially in the context of RNe response. Results are presented in terms of gamma dose rate accuracy obtained by laboratory measurements using radionuclide sources emitting in the 0.059 - 1.333 MeV gamma energy range, compared to theoretical dose rate calculations.
△ Less
Submitted 7 December, 2021;
originally announced December 2021.
-
A First Comparison of the responses of a He4-based fast-neutron detector and a NE-213 liquid-scintillator reference detector
Authors:
R. Jebali,
J. Scherzinger,
J. R. M. Annand,
R. Chandra,
G. Davatz,
K. G. Fissum,
H. Friederich,
U. Gendotti,
R. Hall-Wilton,
E. Håkansson,
K. Kanaki,
M. Lundin,
D. Murer,
B. Nilsson,
A. Rosborg,
H. Svensson
Abstract:
A first comparison has been made between the pulse-shape discrimination characteristics of a novel $^{4}$He-based pressurized scintillation detector and a NE-213 liquid-scintillator reference detector using an Am/Be mixed-field neutron and gamma-ray source and a high-resolution scintillation-pulse digitizer. In particular, the capabilities of the two fast neutron detectors to discriminate between…
▽ More
A first comparison has been made between the pulse-shape discrimination characteristics of a novel $^{4}$He-based pressurized scintillation detector and a NE-213 liquid-scintillator reference detector using an Am/Be mixed-field neutron and gamma-ray source and a high-resolution scintillation-pulse digitizer. In particular, the capabilities of the two fast neutron detectors to discriminate between neutrons and gamma-rays were investigated. The NE-213 liquid-scintillator reference cell produced a wide range of scintillation-light yields in response to the gamma-ray field of the source. In stark contrast, due to the size and pressure of the $^{4}$He gas volume, the $^{4}$He-based detector registered a maximum scintillation-light yield of 750~keV$_{ee}$ to the same gamma-ray field. Pulse-shape discrimination for particles with scintillation-light yields of more than 750~keV$_{ee}$ was excellent in the case of the $^{4}$He-based detector. Above 750~keV$_{ee}$ its signal was unambiguously neutron, enabling particle identification based entirely upon the amount of scintillation light produced.
△ Less
Submitted 27 April, 2015; v1 submitted 13 February, 2015;
originally announced February 2015.
-
Tagging fast neutrons from an 241Am/9Be source
Authors:
J. Scherzinger,
J. R. M. Annand,
G. Davatz,
K. G. Fissum,
U. Gendotti,
R. Hall-Wilton,
A. Rosborg,
E. Håkansson,
R. Jebali,
K. Kanaki,
M. Lundin,
B. Nilsson,
H. Svensson
Abstract:
We report on an investigation of the fast-neutron spectrum emitted by 241Am/9Be. Well-understood shielding, coincidence, and time-of-flight measurement techniques are employed to produce a continuous, polychromatic, energy-tagged neutron beam.
We report on an investigation of the fast-neutron spectrum emitted by 241Am/9Be. Well-understood shielding, coincidence, and time-of-flight measurement techniques are employed to produce a continuous, polychromatic, energy-tagged neutron beam.
△ Less
Submitted 3 January, 2015; v1 submitted 12 May, 2014;
originally announced May 2014.
-
Suitability of high-pressure xenon as scintillator for gamma ray spectroscopy
Authors:
F. Resnati,
U. Gendotti,
R. Chandra,
A. Curioni,
G. Davatz,
H. Frederich,
A. Gendotti,
L. Goeltl,
R. Jebali,
D. Murer,
A. Rubbia
Abstract:
In this paper we report the experimental study of high-pressure xenon used as a scintillator, in the context of develo** a gamma ray detector. We measure a light yield near 2 photoelectrons per keV for xenon at 40 bar. Together with the light yield, we also measured an energy resolution of ~9% (FWHM) at 662 keV, dominated by the statistical fluctuations in the number of photoelectrons.
In this paper we report the experimental study of high-pressure xenon used as a scintillator, in the context of develo** a gamma ray detector. We measure a light yield near 2 photoelectrons per keV for xenon at 40 bar. Together with the light yield, we also measured an energy resolution of ~9% (FWHM) at 662 keV, dominated by the statistical fluctuations in the number of photoelectrons.
△ Less
Submitted 17 December, 2012;
originally announced December 2012.
-
Positronium Portal into Hidden Sector: A new Experiment to Search for Mirror Dark Matter
Authors:
Paolo Crivelli,
Alexander Belov,
Ulisse Gendotti,
Sergei Gninenko,
Andre Rubbia
Abstract:
The understanding of the origin of dark matter has great importance for cosmology and particle physics. Several interesting extensions of the standard model dealing with solution of this problem motivate the concept of hidden sectors consisting of SU(3)xSU(2)_LxU(1)_Y singlet fields. Among these models, the mirror matter model is certainly one of the most interesting. The model explains the origin…
▽ More
The understanding of the origin of dark matter has great importance for cosmology and particle physics. Several interesting extensions of the standard model dealing with solution of this problem motivate the concept of hidden sectors consisting of SU(3)xSU(2)_LxU(1)_Y singlet fields. Among these models, the mirror matter model is certainly one of the most interesting. The model explains the origin of parity violation in weak interactions, it could also explain the baryon asymmetry of the Universe and provide a natural ground for the explanation of dark matter. The mirror matter could have a portal to our world through photon-mirror photon mixing (epsilon). This mixing would lead to orthopositronium (o-Ps) to mirror orthopositronium oscillations, the experimental signature of which is the apparently invisible decay of o-Ps. In this paper, we describe an experiment to search for the decay o-Ps -> invisible in vacuum by using a pulsed slow positron beam and a massive 4pi BGO crystal calorimeter. The developed high efficiency positron tagging system, the low calorimeter energy threshold and high hermiticity allow the expected sensitivity in mixing strength to be epsilon about 10^-9, which is more than one order of magnitude below the current Big Bang Nucleosynthesis limit and in a region of parameter space of great theoretical and phenomenological interest. The vacuum experiment with such sensitivity is particularly timely in light of the recent DAMA/LIBRA observations of the annual modulation signal consistent with a mirror type dark matter interpretation.
△ Less
Submitted 19 July, 2010; v1 submitted 26 May, 2010;
originally announced May 2010.
-
Measurement of the ortho-positronium confinement energy in mesoporous thin films
Authors:
Paolo Crivelli,
Ulisse Gendotti,
André Rubbia,
Laszlo Liszkay,
Patrice Perez,
Catherine Corbel
Abstract:
In this paper, we present measurements of the ortho-positronium emission energy in vacuum from mesoporous films using the time of flight technique. We show evidence of quantum mechanical confinement in the mesopores that defines the minimal energy of the emitted Ps. Two samples with different effective pore sizes, measured with positron annihilation lifetime spectroscopy, are compared for the dat…
▽ More
In this paper, we present measurements of the ortho-positronium emission energy in vacuum from mesoporous films using the time of flight technique. We show evidence of quantum mechanical confinement in the mesopores that defines the minimal energy of the emitted Ps. Two samples with different effective pore sizes, measured with positron annihilation lifetime spectroscopy, are compared for the data collected in the temperature range 50-400 K. The sample with smaller pore size exhibits a higher minimal energy ($73\pm$5 meV), compared to the sample with bigger pores ($48\pm$5 meV), due to the stronger confinement. The dependence of the emission energy with the temperature of the target is modeled as ortho-positronium being confined in rectangular boxes in thermodynamic equilibrium with the sample. We also measured that the yield of positronium emitted in vacuum is not affected by the temperature of the target.
△ Less
Submitted 3 May, 2010; v1 submitted 12 January, 2010;
originally announced January 2010.
-
An Improved Limit on Invisible Decays of Positronium
Authors:
A. Badertscher,
P. Crivelli,
W. Fetscher,
U. Gendotti,
S. Gninenko,
V. Postoev,
A. Rubbia,
V. Samoylenko,
D. Sillou
Abstract:
The results of a new search for positronium decays into invisible final states are reported. Convincing detection of this decay mode would be a strong evid ence for new physics beyond the Standard Model (SM): for example the existence of extra--dimensions, of milli-charged particles, of new light gauge bosons or of mirror particles. Mirror matter could be a relevant dark matter candidate.
In t…
▽ More
The results of a new search for positronium decays into invisible final states are reported. Convincing detection of this decay mode would be a strong evid ence for new physics beyond the Standard Model (SM): for example the existence of extra--dimensions, of milli-charged particles, of new light gauge bosons or of mirror particles. Mirror matter could be a relevant dark matter candidate.
In this paper the setup and the results of a new experiment are presented. In a collected sample of about $(6.31\pm0.28) \times 10^6$ orthopositronium decay s, no evidence for invisible decays in an energy window [0,80] keV was found and an upper limit on the branching ratio of orthopositronium \invdecay could be set: $\binvdecay<4.2\times 10^{-7}$ (90% C.L.)
Our results provide a limit on the photon mirror-photon mixing strength $ε\leq 1.55\times 10^{-7}$ (90% C.L.) and rule out particles lighter than the electron mass with a fraction $Q_x \leq 3.4 \times 10^{-5}$ of the electron charge. Furthermore, upper limits on the branching ratios for the decay of parapositronium $Br(p-Ps\to invisible)\leq 4.3 \times 10^{-7}$ (90% C.L.) and the direct annihilation $Br(e^+e^-\to invisible)\leq 2.1 \times 10^{-8}$ (90% C.L.) could be set.
△ Less
Submitted 5 October, 2006; v1 submitted 29 September, 2006;
originally announced September 2006.