-
Single-frame transmission and phase imaging using off-axis holography with undetected photons
Authors:
Emma Pearce,
Osian Wolley,
Simon P. Mekhail,
Thomas Gregory,
Nathan R. Gemmell,
Rupert F. Oulton,
Alex S. Clark,
Chris C. Phillips,
Miles J. Padgett
Abstract:
Imaging with undetected photons relies upon nonlinear interferometry to extract the spatial image from an infrared probe beam and reveal it in the interference pattern of an easier-to-detect visible beam. Typically, the transmission and phase images are extracted using phase-shifting techniques and combining interferograms from multiple frames. Here we show that off-axis digital holography enables…
▽ More
Imaging with undetected photons relies upon nonlinear interferometry to extract the spatial image from an infrared probe beam and reveal it in the interference pattern of an easier-to-detect visible beam. Typically, the transmission and phase images are extracted using phase-shifting techniques and combining interferograms from multiple frames. Here we show that off-axis digital holography enables reconstruction of both transmission and phase images at the infrared wavelength from a single interferogram, and hence a single frame, recorded in the visible. This eliminates the need for phase step** and multiple acquisitions, thereby greatly reducing total measurement time for imaging with long acquisition times at low flux or enabling video-rate imaging at higher flux. With this single-frame acquisition technique, we are able to reconstruct transmission images of an object in the infrared beam with a signal-to-noise ratio of $1.78\,\pm\,0.06$ at 10 frames per second, and record a dynamic scene in the infrared beam at 33 frames per second.
△ Less
Submitted 29 April, 2024; v1 submitted 20 March, 2024;
originally announced March 2024.
-
Coupling undetected sensing modes by quantum erasure
Authors:
Nathan R. Gemmell,
Yue Ma,
Emma Pearce,
Jefferson Florez,
Olaf Czerwinski,
M. S. Kim,
Rupert F. Oulton,
Alex S. Clark,
Chris C. Phillips
Abstract:
The effect known as ``induced coherence without induced emission'' has spawned a field dedicated to imaging with undetected photons (IUP), where photons from two distinct photon-pair sources interfere if their outputs are made indistinguishable. The indistinguishability is commonly achieved in two setups. Induced coherence IUP (IC-IUP) has only the idler photons from the first source passing throu…
▽ More
The effect known as ``induced coherence without induced emission'' has spawned a field dedicated to imaging with undetected photons (IUP), where photons from two distinct photon-pair sources interfere if their outputs are made indistinguishable. The indistinguishability is commonly achieved in two setups. Induced coherence IUP (IC-IUP) has only the idler photons from the first source passing through the second, whilst nonlinear interferometry (NI-IUP) has both signal and idler photons from the first source passing through the second and can be simpler to implement. In both cases, changes in the idler path between sources can be detected by measuring the interference fringes in the signal path in a way that allows image information to be moved between different wavelengths. Here we model and implement a novel setup that uses a polarization state quantum eraser approach to move continuously between IC-IUP and NI-IUP operation. We find excellent agreement between experiment and theory in the low-gain or quantum regime. The system also provides a new route for optimizing IUP interference by using controllable quantum erasure to balance the interferometer.
△ Less
Submitted 22 November, 2023;
originally announced November 2023.
-
Practical quantum imaging with undetected photons
Authors:
Emma Pearce,
Nathan R. Gemmell,
Jefferson Flórez,
Jiaye Ding,
Rupert F. Oulton,
Alex S. Clark,
Chris C. Phillips
Abstract:
Infrared (IR) imaging is invaluable across many scientific disciplines, from material analysis to diagnostic medicine. However, applications are often limited by detector cost, resolution and sensitivity, noise caused by the thermal IR background, and the cost, portability and tunability of infrared sources. Here, we describe a compact, portable, and low-cost system that is able to image objects a…
▽ More
Infrared (IR) imaging is invaluable across many scientific disciplines, from material analysis to diagnostic medicine. However, applications are often limited by detector cost, resolution and sensitivity, noise caused by the thermal IR background, and the cost, portability and tunability of infrared sources. Here, we describe a compact, portable, and low-cost system that is able to image objects at IR wavelengths without an IR source or IR detector. This imaging with undetected photons (IUP) approach uses quantum interference and correlations between entangled photon pairs to transfer image information from the IR to the visible, where it can be detected with a standard silicon camera. We also demonstrate a rapid analysis approach to acquire both phase and transmission image information. These developments provide an important step towards making IUP a commercially viable technique.
△ Less
Submitted 12 July, 2023;
originally announced July 2023.
-
Eliminating Thermal IR Background Noise by Imaging with Undetected Photons
Authors:
Yue Ma,
Nathan Gemmell,
Emma Pearce,
Rupert Oulton,
Chris Phillips
Abstract:
Spectroscopy and imaging in the mid-infrared (2.5 $μ$m $\sim$ $λ$ $\sim$ 25 $μ$m) is bedevilled by the presence of a strong 300 K thermal background at room temperature that makes IR detectors decades noisier than can be readily achieved in the visible. The technique of "imaging with undetected photons" (IUP) exploits the quantum correlations between entangled photon pairs to transfer image inform…
▽ More
Spectroscopy and imaging in the mid-infrared (2.5 $μ$m $\sim$ $λ$ $\sim$ 25 $μ$m) is bedevilled by the presence of a strong 300 K thermal background at room temperature that makes IR detectors decades noisier than can be readily achieved in the visible. The technique of "imaging with undetected photons" (IUP) exploits the quantum correlations between entangled photon pairs to transfer image information from one spectral region to another, and here we show that it does so in a way that is immune to the thermal background. This means that IUP can be used to perform high speed photon counting measurements across the mid-IR, using uncooled visible detectors that are many times cheaper, faster, and more sensitive than their IR counterparts.
△ Less
Submitted 14 March, 2023;
originally announced March 2023.
-
Enhanced nonlinear interferometry via seeding
Authors:
Jefferson Flórez,
Emma Pearce,
Nathan R. Gemmell,
Yue Ma,
Gabriele Bressanini,
Chris C. Phillips,
Rupert F. Oulton,
Alex S. Clark
Abstract:
We analyse a nonlinear interferometer, also known as an SU(1,1) interferometer, in the presence of internal losses and inefficient detectors. To overcome these limitations, we consider the effect of seeding one of the interferometer input modes with either a number state or a coherent state. We derive analytical expressions for the interference visibility, contrast, phase sensitivity, and signal-t…
▽ More
We analyse a nonlinear interferometer, also known as an SU(1,1) interferometer, in the presence of internal losses and inefficient detectors. To overcome these limitations, we consider the effect of seeding one of the interferometer input modes with either a number state or a coherent state. We derive analytical expressions for the interference visibility, contrast, phase sensitivity, and signal-to-noise ratio, and show a significant enhancement in all these quantities as a function of the seeding photon number. For example, we predict that, even in the presence of substantial losses and highly inefficient detectors, we can achieve the same quantum-limited phase sensitivity of an unseeded nonlinear interferometer by seeding with a few tens of photons. Furthermore, we observe no difference between a number or a coherent seeding state when the interferometer operates in the low-gain regime, which enables seeding with an attenuated laser. Our results expand the nonlinear interferometry capabilities in the field of quantum imaging, metrology, and spectroscopy under realistic experimental conditions.
△ Less
Submitted 26 September, 2022; v1 submitted 14 September, 2022;
originally announced September 2022.
-
Loss compensated and enhanced mid-infrared interaction-free sensing with undetected photons
Authors:
Nathan R. Gemmell,
Jefferson Florez,
Emma Pearce,
Olaf Czerwinski,
Chris C. Phillips,
Rupert F. Oulton,
Alex S. Clark
Abstract:
Sensing with undetected photons enables the measurement of absorption and phase shifts at wavelengths different from those detected. Here, we experimentally map the balance and loss parameter space in a non-degenerate nonlinear interferometer, showing the recovery of sensitivity despite internal losses at the detection wavelength. We further explore an interaction-free operation mode with a detect…
▽ More
Sensing with undetected photons enables the measurement of absorption and phase shifts at wavelengths different from those detected. Here, we experimentally map the balance and loss parameter space in a non-degenerate nonlinear interferometer, showing the recovery of sensitivity despite internal losses at the detection wavelength. We further explore an interaction-free operation mode with a detector-to-sample incident optical power ratio of >200. This allows changes in attowatt levels of power at 3.4 $μ$m wavelength to be detected at 1550 nm, immune to the level of thermal black-body background. This reveals an ultra-sensitive infrared imaging methodology capable of probing samples effectively `in the dark'.
△ Less
Submitted 18 May, 2022;
originally announced May 2022.
-
Robust haplotype-resolved assembly of diploid individuals without parental data
Authors:
Haoyu Cheng,
Erich D. Jarvis,
Olivier Fedrigo,
Klaus-Peter Koepfli,
Lara Urban,
Neil J. Gemmell,
Heng Li
Abstract:
Routine single-sample haplotype-resolved assembly remains an unresolved problem. Here we describe a new algorithm that combines PacBio HiFi reads and Hi-C chromatin interaction data to produce a haplotype-resolved assembly without the sequencing of parents. Applied to human and other vertebrate samples, our algorithm consistently outperforms existing single-sample assembly pipelines and generates…
▽ More
Routine single-sample haplotype-resolved assembly remains an unresolved problem. Here we describe a new algorithm that combines PacBio HiFi reads and Hi-C chromatin interaction data to produce a haplotype-resolved assembly without the sequencing of parents. Applied to human and other vertebrate samples, our algorithm consistently outperforms existing single-sample assembly pipelines and generates assemblies of comparable quality to the best pedigree-based assemblies.
△ Less
Submitted 10 September, 2021;
originally announced September 2021.
-
arXiv:1302.6371
[pdf]
physics.ins-det
physics.bio-ph
physics.chem-ph
physics.med-ph
physics.optics
Singlet oxygen luminescence detection with a fiber-coupled superconducting nanowire single-photon detector
Authors:
Nathan R. Gemmell,
Aongus McCarthy,
Baochang Liu,
Michael G. Tanner,
Sander N. Dorenbos,
Valery Zwiller,
Michael S. Patterson,
Gerald S. Buller,
Brian C. Wilson,
Robert H. Hadfield
Abstract:
Direct monitoring of singlet oxygen (1O2) luminescence is a particularly challenging infrared photodetection problem. 1O2, an excited state of the oxygen molecule, is a crucial intermediate in many biological processes. We employ a low noise superconducting nanowire single-photon detector to record 1O2 luminescence at 1270 nm wavelength from a model photosensitizer (Rose Bengal) in solution. Narro…
▽ More
Direct monitoring of singlet oxygen (1O2) luminescence is a particularly challenging infrared photodetection problem. 1O2, an excited state of the oxygen molecule, is a crucial intermediate in many biological processes. We employ a low noise superconducting nanowire single-photon detector to record 1O2 luminescence at 1270 nm wavelength from a model photosensitizer (Rose Bengal) in solution. Narrow band spectral filtering and chemical quenching is used to verify the 1O2 signal, and lifetime evolution with the addition of protein is studied. Furthermore, we demonstrate the detection of 1O2 luminescence through a single optical fiber, a marked advance for dose monitoring in clinical treatments such as photodynamic therapy.
△ Less
Submitted 26 February, 2013;
originally announced February 2013.