-
QUBIC: the Q & U Bolometric Interferometer for Cosmology
Authors:
E. S. Battistelli,
P. Ade,
J. G. Alberro,
A. Almela,
G. Amico,
L. H. Arnaldi,
D. Auguste,
J. Aumont,
S. Azzoni,
S. Banfi,
P. Battaglia,
A. Baù,
B. Bèlier,
D. Bennett,
L. Bergè,
J. -Ph. Bernard,
M. Bersanelli,
M. -A. Bigot-Sazy,
N. Bleurvacq,
J. Bonaparte,
J. Bonis,
A. Bottani,
E. Bunn,
D. Burke,
D. Buzi
, et al. (114 additional authors not shown)
Abstract:
The Q & U Bolometric Interferometer for Cosmology, QUBIC, is an innovative experiment designed to measure the polarization of the Cosmic Microwave Background and in particular the signature left therein by the inflationary expansion of the Universe. The expected signal is extremely faint, thus extreme sensitivity and systematic control are necessary in order to attempt this measurement. QUBIC addr…
▽ More
The Q & U Bolometric Interferometer for Cosmology, QUBIC, is an innovative experiment designed to measure the polarization of the Cosmic Microwave Background and in particular the signature left therein by the inflationary expansion of the Universe. The expected signal is extremely faint, thus extreme sensitivity and systematic control are necessary in order to attempt this measurement. QUBIC addresses these requirements using an innovative approach combining the sensitivity of Transition Edge Sensor cryogenic bolometers, with the deep control of systematics characteristic of interferometers. This makes QUBIC unique with respect to others classical imagers experiments devoted to the CMB polarization. In this contribution we report a description of the QUBIC instrument including recent achievements and the demonstration of the bolometric interferometry performed in lab. QUBIC will be deployed at the observation site in Alto Chorrillos, in Argentina at the end of 2019.
△ Less
Submitted 28 January, 2020;
originally announced January 2020.
-
QUBIC: using NbSi TESs with a bolometric interferometer to characterize the polarisation of the CMB
Authors:
M. Piat,
B. Bélier,
L. Bergé,
N. Bleurvacq,
C. Chapron,
S. Dheilly,
L. Dumoulin,
M. González,
L. Grandsire,
J. -Ch. Hamilton,
S. Henrot-Versillé,
D. T. Hoang,
S. Marnieros,
W. Marty,
L. Montier,
E. Olivieri,
C. Oriol,
C. Perbost,
D. Prêle,
D. Rambaud,
M. Salatino,
G. Stankowiak,
J. -P. Thermeau,
S. Torchinsky,
F. Voisin
, et al. (113 additional authors not shown)
Abstract:
QUBIC (Q \& U Bolometric Interferometer for Cosmology) is an international ground-based experiment dedicated in the measurement of the polarized fluctuations of the Cosmic Microwave Background (CMB). It is based on bolometric interferometry, an original detection technique which combine the immunity to systematic effects of an interferometer with the sensitivity of low temperature incoherent detec…
▽ More
QUBIC (Q \& U Bolometric Interferometer for Cosmology) is an international ground-based experiment dedicated in the measurement of the polarized fluctuations of the Cosmic Microwave Background (CMB). It is based on bolometric interferometry, an original detection technique which combine the immunity to systematic effects of an interferometer with the sensitivity of low temperature incoherent detectors. QUBIC will be deployed in Argentina, at the Alto Chorrillos mountain site near San Antonio de los Cobres, in the Salta province.
The QUBIC detection chain consists in 2048 NbSi Transition Edge Sensors (TESs) cooled to 350mK.The voltage-biased TESs are read out with Time Domain Multiplexing based on Superconducting QUantum Interference Devices (SQUIDs) at 1 K and a novel SiGe Application-Specific Integrated Circuit (ASIC) at 60 K allowing to reach an unprecedented multiplexing (MUX) factor equal to 128.
The QUBIC experiment is currently being characterized in the lab with a reduced number of detectors before upgrading to the full instrument. I will present the last results of this characterization phase with a focus on the detectors and readout system.
△ Less
Submitted 9 December, 2019; v1 submitted 27 November, 2019;
originally announced November 2019.
-
QUBIC: Exploring the primordial Universe with the Q\&U Bolometric Interferometer
Authors:
Aniello Mennella,
Peter Ade,
Giorgio Amico,
Didier Auguste,
Jonathan Aumont,
Stefano Banfi,
Gustavo Barbaràn,
Paola Battaglia,
Elia Battistelli,
Alessandro Baù,
Benoit Bélier,
David G. Bennett,
Laurent Bergé,
Jean Philippe Bernard,
Marco Bersanelli,
Marie Anne Bigot Sazy,
Nathat Bleurvacq,
Juan Bonaparte,
Julien Bonis,
Emory F. Bunn,
David Burke,
Daniele Buzi,
Alessandro Buzzelli,
Francesco Cavaliere,
Pierre Chanial
, et al. (105 additional authors not shown)
Abstract:
In this paper we describe QUBIC, an experiment that will observe the polarized microwave sky with a novel approach, which combines the sensitivity of state-of-the art bolometric detectors with the systematic effects control typical of interferometers. QUBIC unique features are the so-called "self-calibration", a technique that allows us to clean the measured data from instrumental effects, and its…
▽ More
In this paper we describe QUBIC, an experiment that will observe the polarized microwave sky with a novel approach, which combines the sensitivity of state-of-the art bolometric detectors with the systematic effects control typical of interferometers. QUBIC unique features are the so-called "self-calibration", a technique that allows us to clean the measured data from instrumental effects, and its spectral imaging power, i.e. the ability to separate the signal in various sub-bands within each frequency band. QUBIC will observe the sky in two main frequency bands: 150 GHz and 220 GHz. A technological demonstrator is currently under testing and will be deployed in Argentina during 2019, while the final instrument is expected to be installed during 2020.
△ Less
Submitted 23 January, 2019; v1 submitted 30 November, 2018;
originally announced December 2018.
-
Thermal architecture for the QUBIC cryogenic receiver
Authors:
A. J. May,
C. Chapron,
G. Coppi,
G. D'Alessandro,
P. de Bernardis,
S. Masi,
S. Melhuish,
M. Piat,
L. Piccirillo,
A. Schillaci,
J. -P. Thermeau,
P. Ade,
G. Amico,
D. Auguste,
J. Aumont,
S. Banfi,
G. Barbara,
P. Battaglia,
E. Battistelli,
A. Bau,
B. Belier,
D. Bennett,
L. Berge,
J. -Ph. Bernard,
M. Bersanelli
, et al. (105 additional authors not shown)
Abstract:
QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming instrument to measure the B-mode polarization anisotropy of the Cosmic Microwave Background. The detection of the B-mode signal will be extremely challenging; QUBIC has been designed to address this with a novel approach, namely bolometric interferometry. The receiver cryostat is exceptionally large and cools complex opt…
▽ More
QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming instrument to measure the B-mode polarization anisotropy of the Cosmic Microwave Background. The detection of the B-mode signal will be extremely challenging; QUBIC has been designed to address this with a novel approach, namely bolometric interferometry. The receiver cryostat is exceptionally large and cools complex optical and detector stages to 40 K, 4 K, 1 K and 350 mK using two pulse tube coolers, a novel 4He sorption cooler and a double-stage 3He/4He sorption cooler. We discuss the thermal and mechanical design of the cryostat, modelling and thermal analysis, and laboratory cryogenic testing.
△ Less
Submitted 6 November, 2018;
originally announced November 2018.
-
QUBIC - The Q&U Bolometric Interferometer for Cosmology - A novel way to look at the polarized Cosmic Microwave Background
Authors:
A. Mennella,
P. A. R. Ade,
J. Aumont,
S. Banfi,
P. Battaglia,
E. S. Battistelli,
A. Baù,
B. Bélier,
D. Bennett,
L. Bergé,
J. Ph. Bernard,
M. Bersanelli,
M. A. Bigot-Sazy,
N. Bleurvacq,
G. Bordier,
J. Brossard,
E. F. Bunn,
D. P. Burke,
D. Buzi,
A. Buzzelli,
D. Cammilleri,
F. Cavaliere,
P. Chanial,
C. Chapron,
F. Columbro
, et al. (83 additional authors not shown)
Abstract:
In this paper we describe QUBIC, an experiment that takes up the challenge posed by the detection of primordial gravitational waves with a novel approach, that combines the sensitivity of state-of-the art bolometric detectors with the systematic effects control typical of interferometers. The so-called "self-calibration" is a technique deeply rooted in the interferometric nature of the instrument…
▽ More
In this paper we describe QUBIC, an experiment that takes up the challenge posed by the detection of primordial gravitational waves with a novel approach, that combines the sensitivity of state-of-the art bolometric detectors with the systematic effects control typical of interferometers. The so-called "self-calibration" is a technique deeply rooted in the interferometric nature of the instrument and allows us to clean the measured data from instrumental effects. The first module of QUBIC is a dual band instrument (150 GHz and 220 GHz) that will be deployed in Argentina during the Fall 2018.
△ Less
Submitted 11 January, 2018;
originally announced January 2018.
-
QUBIC Technical Design Report
Authors:
J. Aumont,
S. Banfi,
P. Battaglia,
E. S. Battistelli,
A. Baù,
B. Bélier,
D. Bennett,
L. Bergé,
J. Ph. Bernard,
M. Bersanelli,
M. A. Bigot-Sazy,
N. Bleurvacq,
G. Bordier,
J. Brossard,
E. F. Bunn,
D. Buzi,
A. Buzzelli,
D. Cammilleri,
F. Cavaliere,
P. Chanial,
C. Chapron,
G. Coppi,
A. Coppolecchia,
F. Couchot,
R. D'Agostino
, et al. (74 additional authors not shown)
Abstract:
QUBIC is an instrument aiming at measuring the B mode polarisation anisotropies at medium scales angular scales (30-200 multipoles). The search for the primordial CMB B-mode polarization signal is challenging, because of many difficulties: smallness of the expected signal, instrumental systematics that could possibly induce polarization leakage from the large E signal into B, brighter than anticip…
▽ More
QUBIC is an instrument aiming at measuring the B mode polarisation anisotropies at medium scales angular scales (30-200 multipoles). The search for the primordial CMB B-mode polarization signal is challenging, because of many difficulties: smallness of the expected signal, instrumental systematics that could possibly induce polarization leakage from the large E signal into B, brighter than anticipated polarized foregrounds (dust) reducing to zero the initial hope of finding sky regions clean enough to have a direct primordial B-modes observation. The QUBIC instrument is designed to address all aspects of this challenge with a novel kind of instrument, a Bolometric Interferometer, combining the background-limited sensitivity of Transition-Edge-Sensors and the control of systematics allowed by the observation of interference fringe patterns, while operating at two frequencies to disentangle polarized foregrounds from primordial B mode polarization. Its characteristics are described in details in this Technological Design Report.
△ Less
Submitted 11 May, 2017; v1 submitted 14 September, 2016;
originally announced September 2016.
-
Latest Progress on the QUBIC Instrument
Authors:
A. Ghribi,
J. Aumont,
E. S. Battistelli,
A. Bau,
L. Bergé,
J-Ph. Bernard,
M. Bersanelli,
M-A. Bigot-Sazy,
G. Bordier,
E. T. Bunn,
F. Cavaliere,
P. Chanial,
A. Coppolecchia,
T. Decourcelle,
P. De Bernardis,
M. De Petris,
A-A. Drilien,
L. Dumoulin,
M. C. Falvella,
A. Gault,
M. Gervasi,
M. Giard,
M. Gradziel,
L. Grandsire,
D. Gayer
, et al. (38 additional authors not shown)
Abstract:
QUBIC is a unique instrument that crosses the barriers between classical imaging architectures and interferometry taking advantage from both for high sensitivity and systematics mitigation. The scientific target is the detection of the primordial gravitational waves imprint on the Cosmic Microwave Background which are the proof of inflation, holy grail of modern cosmology. In this paper, we show t…
▽ More
QUBIC is a unique instrument that crosses the barriers between classical imaging architectures and interferometry taking advantage from both for high sensitivity and systematics mitigation. The scientific target is the detection of the primordial gravitational waves imprint on the Cosmic Microwave Background which are the proof of inflation, holy grail of modern cosmology. In this paper, we show the latest advances in the development of the architecture and the sub-systems of the first module of this instrument to be deployed in Dome Charlie Concordia base - Antarctica in 2015.
△ Less
Submitted 12 November, 2013; v1 submitted 22 July, 2013;
originally announced July 2013.
-
QUBIC: The QU Bolometric Interferometer for Cosmology
Authors:
The QUBIC collaboration,
E. Battistelli,
A. Baù,
D. Bennett,
L. Bergé,
J. -Ph. Bernard,
P. de Bernardis,
A. Bounab,
É. Bréelle,
E. F. Bunn,
M. Calvo,
R. Charlassier,
S. Collin,
A. Cruciani,
G. Curran,
L. Dumoulin,
A. Gault,
M. Gervasi,
A. Ghribi,
M. Giard,
C. Giordano,
Y. Giraud-Héraud,
M. Gradziel,
L. Guglielmi,
J. -Ch. Hamilton
, et al. (35 additional authors not shown)
Abstract:
One of the major challenges of modern cosmology is the detection of B-mode polarization anisotropies in the CMB. These originate from tensor fluctuations of the metric produced during the inflationary phase. Their detection would therefore constitute a major step towards understanding the primordial Universe. The expected level of these anisotropies is however so small that it requires a new gener…
▽ More
One of the major challenges of modern cosmology is the detection of B-mode polarization anisotropies in the CMB. These originate from tensor fluctuations of the metric produced during the inflationary phase. Their detection would therefore constitute a major step towards understanding the primordial Universe. The expected level of these anisotropies is however so small that it requires a new generation of instruments with high sensitivity and extremely good control of systematic effects. We propose the QUBIC instrument based on the novel concept of bolometric interferometry, bringing together the sensitivity advantages of bolometric detectors with the systematics effects advantages of interferometry. Methods: The instrument will directly observe the sky through an array of entry horns whose signals will be combined together using an optical combiner. The whole set-up is located inside a cryostat. Polarization modulation will be achieved using a rotating half-wave plate and interference fringes will be imaged on two focal planes (separated by a polarizing grid) tiled with bolometers. We show that QUBIC can be considered as a synthetic imager, exactly similar to a usual imager but with a synthesized beam formed by the array of entry horns. Scanning the sky provides an additional modulation of the signal and improve the sky coverage shape. The usual techniques of map-making and power spectrum estimation can then be applied. We show that the sensitivity of such an instrument is comparable with that of an imager with the same number of horns. We anticipate a low level of beam-related systematics thanks to the fact that the synthesized beam is determined by the location of the primary horns. Other systematics should be under good control thanks to an autocalibration technique, specific to our concept, that will permit the accurate determination of most of the systematics parameters.
△ Less
Submitted 4 October, 2010;
originally announced October 2010.
-
Spectroscopic and Spectropolarimetric Observations of V838 Mon
Authors:
John P. Wisniewski,
Nancy D. Morrison,
Karen S. Bjorkman,
Anatoly S. Miroshnichenko,
Amanda C. Gault,
Jennifer L. Hoffman,
Marilyn R. Meade,
Jason M. Nett
Abstract:
The spectroscopic and spectropolarimetric variability of the peculiar variable V838 Monocerotis during the brighter phases of its multiple outbursts in 2002 is presented. Significant line profile variability of H$α$ and Si II 6347.10Å& 6371.36Åoccurred in spectra obtained between 2002 February 5 and 2002 March 14, and a unique secondary absorption component was observed near the end of this time…
▽ More
The spectroscopic and spectropolarimetric variability of the peculiar variable V838 Monocerotis during the brighter phases of its multiple outbursts in 2002 is presented. Significant line profile variability of H$α$ and Si II 6347.10Å& 6371.36Åoccurred in spectra obtained between 2002 February 5 and 2002 March 14, and a unique secondary absorption component was observed near the end of this time period. Our observations also suggest that multiple shifts in ionization states occurred during the outbursts. Spectropolarimetric observations reveal that V838 Mon exhibited both intrinsic and interstellar polarization components during the initial stages of the second outburst, indicating the presence of an asymmetric geometry; however, the intrinsic component had significantly declined by February 14. We determine the interstellar polarization to be $P_{max} = 2.746 \pm 0.011 %$, $λ_{max} = 5790 \pm 37Å$, $PA = 153.43 \pm 0.12 ^{\circ} $, and we find the integrated intrinsic V band polarization on February 5 to be $P = 0.983 \pm 0.012 %$ at a position angle of $127.0 \pm 0.5^{\circ}$. The implications of these observations for the nature of V838 Monocerotis, its distance, and its ejecta are discussed.
△ Less
Submitted 13 January, 2003;
originally announced January 2003.
-
Big Bang Nucleosynthesis Constraints on Brane Cosmologies
Authors:
Jonathan D. Bratt,
A. C. Gault,
Robert J. Scherrer,
T. P. Walker
Abstract:
We examine constraints from Big Bang nucleosynthesis on type II Randall-Sundrum brane cosmologies with both a dark radiation component and a quadratic term that depends on the 5-dimensional Planck mass, M_5. Using limits on the abundances of deuterium and helium-4, we calculate the allowed region in the M_5-dark radiation plane and derive the precise BBN bound on M_5 alone with no dark radiation…
▽ More
We examine constraints from Big Bang nucleosynthesis on type II Randall-Sundrum brane cosmologies with both a dark radiation component and a quadratic term that depends on the 5-dimensional Planck mass, M_5. Using limits on the abundances of deuterium and helium-4, we calculate the allowed region in the M_5-dark radiation plane and derive the precise BBN bound on M_5 alone with no dark radiation: M_5 > 13 TeV.
△ Less
Submitted 30 August, 2002; v1 submitted 6 August, 2002;
originally announced August 2002.