-
Motion rejection and spectral unmixing for accurate estimation of in vivo oxygen saturation using multispectral optoacoustic tomography
Authors:
Mitradeep Sarkar,
Mailyn Pérez-Liva,
Gilles Renault,
Bertrand Tavitian,
Jérôme Gateau
Abstract:
Multispectral Optoacoustic Tomography (MSOT) uniquely enables spatial map** in high resolution of oxygen saturation (SO$_2$), with potential applications in studying pathological complications and therapy efficacy. MSOT offers seamless integration with ultrasonography, by using a common ultrasound detector array. However, MSOT relies on multiple successive acquisitions of optoacoustic (OA) image…
▽ More
Multispectral Optoacoustic Tomography (MSOT) uniquely enables spatial map** in high resolution of oxygen saturation (SO$_2$), with potential applications in studying pathological complications and therapy efficacy. MSOT offers seamless integration with ultrasonography, by using a common ultrasound detector array. However, MSOT relies on multiple successive acquisitions of optoacoustic (OA) images at different optical wavelengths and the low frame rate of OA imaging makes the MSOT acquisition sensitive to body/respiratory motion. Moreover, estimation of SO$_2$ is highly sensitive to noise, and artefacts related to the respiratory motion of the animal were identified as the primary source of noise in MSOT.In this work, we propose a two-step image processing method for SO$_2$ estimation in deep tissues. First, to mitigate motion artefacts, we propose a method of selection of OA images acquired only during the respiratory pause of the animal, using ultrafast ultrasound images (USIs) acquired immediately after each OA acquisition (USI acquisition duration of 1.4 ms and a total delay of 7 ms). We show that gating is more effective using USIs than OA images at different optical wavelengths. Secondly, we propose a novel method which can estimate directly the SO$_2$ value of a pixel and at the same time evaluate the amount of noise present in that pixel. Hence, the method can efficiently eliminate the pixels dominated by noise from the final SO$_2$ map. Our post-processing method is shown to outperform conventional methods for SO$_2$ estimation, and the method was validated by in vivo oxygen challenge experiments.
△ Less
Submitted 15 September, 2023;
originally announced September 2023.
-
Volumetric and Simultaneous Photoacoustic and Ultrasound Imaging with a Conventional Linear Array in a Multiview Scanning Scheme
Authors:
Clément Linger,
Yoann Atlas,
Remy Winter,
Marine Vandebrouck,
Maxime Faure,
Théotim Lucas,
S. Lori Bridal,
Jérôme Gateau
Abstract:
Volumetric, multimodal imaging with precise spatial and temporal co-registration can provide valuable and complementary information for diagnosis and monitoring. Considerable research has sought to combine 3D photoacoustic (PA) and ultrasound (US) imaging in clinically translatable configurations. However, technical compromises currently result in poor image quality either for photoacoustic or ult…
▽ More
Volumetric, multimodal imaging with precise spatial and temporal co-registration can provide valuable and complementary information for diagnosis and monitoring. Considerable research has sought to combine 3D photoacoustic (PA) and ultrasound (US) imaging in clinically translatable configurations. However, technical compromises currently result in poor image quality either for photoacoustic or ultrasonic modes. This work aims to provide translatable, high quality, simultaneously co-registered dual-mode PA/US 3D tomography. Volumetric imaging based on a synthetic aperture approach was implemented by interlacing PA and US acquisitions during a rotate-translate scan with a 5-MHz linear array (12 angles and 30-mm translation to image a 21-mm diameter, 19 mm long cylindrical volume within 21 seconds). For co-registration, an original calibration method using a specifically designed thread phantom was developed to estimate 6 geometrical parameters and 1 temporal off-set through global optimization of the reconstructed sharpness and superposition of calibration phantom structures. Phantom design and cost function metrics were selected based on analysis of a numerical phantom, and resulted in a high estimation accuracy for the 7 parameters. Experimental estimations validated the calibration repeatability. The estimated parameters were used for bimodal reconstruction of additional phantoms with either identical or distinct spatial distributions of US and PA contrasts. Superposition distance of the two modes was within < 10% of the acoustic wavelength and a wavelength-order uniform spatial resolution was obtained. This dual-mode PA/US tomography should contribute to more sensitive and robust detection and follow-up of biological changes or the monitoring slower-kinetic phenomena in living systems such as the accumulation of nanoagents.
△ Less
Submitted 21 April, 2023; v1 submitted 2 January, 2023;
originally announced January 2023.
-
Femtosecond laser-shockwave induced densification in fused silica
Authors:
Arunkrishnan Radhakrishnan,
Julien Gateau,
Pieter Vlugter,
Yves Bellouard
Abstract:
Tightly focused femtosecond laser-beam in the non-ablative regime can induce a shock-wave enough to reach locally pressures in the giga-Pascal range or more. In a single beam configuration, the location of the highest-pressure zone is nested within the laser-focus zone, making it difficult to differentiate the effect of the shock-wave pressure from photo-induced and plasma relaxation effect. To ci…
▽ More
Tightly focused femtosecond laser-beam in the non-ablative regime can induce a shock-wave enough to reach locally pressures in the giga-Pascal range or more. In a single beam configuration, the location of the highest-pressure zone is nested within the laser-focus zone, making it difficult to differentiate the effect of the shock-wave pressure from photo-induced and plasma relaxation effect. To circumvent this difficulty, we consider two spatially separated focused beams that individually act as quasi-simultaneous pressure-wave emitters. The zone where both shock-waves interfere constructively forms a region of extreme pressure range, physically separated from the regions under direct laser exposure. Here, we present evidences of pressured-induced densification in fused silica in between the foci of the two beams, which can be exclusively attributed to the superposition of the pressure waves emitted by each focused laser-beam. Specifically, we show how the beams gap and pulses time-delay affect the structural properties of fused silica using Raman characterization, beam deflection technique, and selective etching techniques. The method is generic and can be implemented in a variety of transparent substrates for high-pressure physics studies and, unlike classical methods, such as the use of diamond anvils, offers a means to create arbitrary-shaped laser-induced high-pressure impacted zones by scanning the two beams across the specimen volume
△ Less
Submitted 28 February, 2022;
originally announced February 2022.
-
High contrast and resolution 3-D ultrasonography with a clinical linear transducer array scanned in a rotate-translate geometry
Authors:
Théotim Lucas,
Isabelle Quidu,
S. Lori Bridal,
Jerome Gateau
Abstract:
We propose a novel solution for volumetric ultrasound imaging using single-side access 3-D synthetic-aperture scanning of a clinical linear array. This solution is based on an advanced scanning geometry and a software-based ultrasound platform. The rotate-translate scanning scheme increases the elevation angular aperture by pivoting the array [-45{\textdegree} to 45{\textdegree}] around its array…
▽ More
We propose a novel solution for volumetric ultrasound imaging using single-side access 3-D synthetic-aperture scanning of a clinical linear array. This solution is based on an advanced scanning geometry and a software-based ultrasound platform. The rotate-translate scanning scheme increases the elevation angular aperture by pivoting the array [-45{\textdegree} to 45{\textdegree}] around its array axis (axis along the row of its elements) and then, scans the imaged object for each pivoted angle by translating the array perpendicularly to the rotation axis. A theoretical basis is presented so that the angular and translational scan sampling periods can be best adjusted for any linear transducer array. We experimentally implemented scanning with a 5-MHz array. In vitro characterization was performed with phantoms designed to test resolution and contrast. Spatial resolution assessed based on the full-width half-maximum of images from isolated microspheres was increased by a factor 3 along the translational direction from a simple translation scan of the array. Moreover, the resolution is uniform over a cross-sectional area of 4.5 cm 2. Angular sampling periods were optimized and tapered to decrease the scan duration while maintaining image contrast (contrast at the center of a 5 mm cyst on the order of-26 dB for 4{\textdegree} angular period and a scan duration of 10 s for a 9cm 3 volume). We demonstrate that superior 3-D US imaging can be obtained with a clinical array using our scanning strategy. This technique offers a promising and flexible alternative to development of costly matrix arrays toward the development of sensitive volumetric ultrasonography.
△ Less
Submitted 26 January, 2021; v1 submitted 19 November, 2020;
originally announced November 2020.
-
Calibrated photoacoustic spectrometer based on a conventional imaging system for in vitro characterization of contrast agents
Authors:
Théotim Lucas,
Mitradeep Sarkar,
Yoann Atlas,
Clément Linger,
Gilles Renault,
Florence Gazeau,
Jérôme Gateau
Abstract:
Photoacoustic (PA) imaging systems are spreading in the biomedical community, and the de-velopment of new PA contrast agents is an active area of research. However, PA contrast agents are usually characterized with spectrophotometry or uncalibrated PA imaging systems, leading to partial assessment of their PA efficiency. To enable quantitative PA spectroscopy of contrast agents in vitro with conve…
▽ More
Photoacoustic (PA) imaging systems are spreading in the biomedical community, and the de-velopment of new PA contrast agents is an active area of research. However, PA contrast agents are usually characterized with spectrophotometry or uncalibrated PA imaging systems, leading to partial assessment of their PA efficiency. To enable quantitative PA spectroscopy of contrast agents in vitro with conventional PA imaging systems, we have developed an adapted calibration method. Contrast agents in solution are injected in a dedicated non-scattering tube phantom imaged at different optical wavelengths. The calibration method uses a reference solu-tion of cupric sulfate to simultaneously correct for the spectral energy distribution of excitation light at the tube location and perform a conversion of the tube amplitude in the image from ar-bitrary to spectroscopic units. The method does not require any precise alignment and provides quantitative PA spectra, even with non-uniform illumination and ultrasound sensitivity. It was implemented on a conventional imaging setup based on a tunable laser operating between 680 nm and 980 nm and a 5 MHz clinical ultrasound array. We demonstrated robust calibrated PA spectroscopy with sample volumes as low as 15 μL of known chromophores and commonly used contrast agents. The validated method will be an essential and accessible tool for the de-velopment of new and efficient PA contrast agents by improving their quantitative characterization.
△ Less
Submitted 5 September, 2022; v1 submitted 16 March, 2020;
originally announced March 2020.
-
Topological transformations of speckles
Authors:
Jerome Gateau,
Ferdinand Claude,
Gilles Tessier,
Marc Guillon
Abstract:
Deterministic control of coherent random light is highly important for information transmission through complex media. However, only a few simple speckle transformations can be achieved through diffusers without prior characterization. As recently shown, spiral wavefront modulation of the im**ing beam allows permuting intensity maxima and intrinsic $\pm 1$-charged optical vortices. Here, we stud…
▽ More
Deterministic control of coherent random light is highly important for information transmission through complex media. However, only a few simple speckle transformations can be achieved through diffusers without prior characterization. As recently shown, spiral wavefront modulation of the im**ing beam allows permuting intensity maxima and intrinsic $\pm 1$-charged optical vortices. Here, we study this cyclic-group algebra when combining spiral phase transforms of charge $n$, with $D_3$- and $D_4$-point-group symmetry star-like amplitude modulations. This combination allows statistical strengthening of permutations and controlling the period to be 3 and 4, respectively. Phase saddle-points are shown to complete the cycle. These results offer new tools to manipulate critical points in speckles.
△ Less
Submitted 17 July, 2019; v1 submitted 31 January, 2019;
originally announced January 2019.
-
Dynamical analysis in a self-regulated system undergoing multiple excitations: first order differential equation approach
Authors:
Denis Mongin,
Adriana Uribe,
Julien Gateau,
Baris Gencer,
Boris Cheval,
Stéphane Cullati,
Delphine S. Courvoisier
Abstract:
This article proposes a dynamical system modeling approach for the analysis of longitudinal data of self-regulated systems experiencing multiple excitations. The aim of such an approach is to focus on the evolution of a signal (e.g., heart rate) before, during, and after excitations taking the system out of its equilibrium (e.g., physical effort during cardiac stress testing). Dynamical modeling c…
▽ More
This article proposes a dynamical system modeling approach for the analysis of longitudinal data of self-regulated systems experiencing multiple excitations. The aim of such an approach is to focus on the evolution of a signal (e.g., heart rate) before, during, and after excitations taking the system out of its equilibrium (e.g., physical effort during cardiac stress testing). Dynamical modeling can be applied to a broad range of outcomes such as physiological processes in medicine and psychosocial processes in social sciences, and it allows to extract simple characteristics of the signal studied. The model we propose is based on a first order linear differential equation defined by three main parameters corresponding to the initial equilibrium value, the dynamic characteristic time, and the reaction to the excitation. In this paper, several estimation procedures for this model are considered and tested in a simulation study, that clarifies under which conditions accurate estimates are provided. Finally, applications of this model are illustrated using cardiology data recorded during effort tests.
△ Less
Submitted 1 March, 2020; v1 submitted 21 December, 2018;
originally announced January 2019.
-
Amplification of intense light fields by nearly free electrons
Authors:
Mary Matthews,
Felipe Morales,
Alexander Patas,
Albrecht Lindinger,
Julien Gateau,
Nicolas Berti,
Sylvain Hermelin,
Jérôme Kasparian,
Maria Richter,
Timm Bredtmann,
Olga Smirnova,
Jean-Pierre Wolf,
Misha Ivanov
Abstract:
Light can be used to modify and control properties of media, as in the case of electromagnetically induced transparency or, more recently, for the generation of slow light or bright coherent XUV and X-ray radiation. Particularly unusual states of matter can be created by light fields with strengths comparable to the Coulomb field that binds valence electrons in atoms, leading to nearly-free electr…
▽ More
Light can be used to modify and control properties of media, as in the case of electromagnetically induced transparency or, more recently, for the generation of slow light or bright coherent XUV and X-ray radiation. Particularly unusual states of matter can be created by light fields with strengths comparable to the Coulomb field that binds valence electrons in atoms, leading to nearly-free electrons oscillating in the laser field and yet still loosely bound to the core [1,2]. These are known as Kramers-Henneberger states [3], a specific example of laser-dressed states [2]. Here, we demonstrate that these states arise not only in isolated atoms [4,5], but also in rare gases, at and above atmospheric pressure, where they can act as a gain medium during laser filamentation. Using shaped laser pulses, gain in these states is achieved within just a few cycles of the guided field. The corresponding lasing emission is a signature of population inversion in these states and of their stability against ionization. Our work demonstrates that these unusual states of neutral atoms can be exploited to create a general ultrafast gain mechanism during laser filamentation.
△ Less
Submitted 25 October, 2018;
originally announced October 2018.
-
Modifications of filament spectra by shaped octave-spanning laser pulses
Authors:
Alexander Patas,
Mary Matthews,
Sylvain Hermelin,
Julien Gateau,
Jérôme Kasparian,
Jean-Pierre Wolf,
Albrecht Lindinger
Abstract:
In this paper we examine the spectral changes in a white light laser filament due to different pulse shapes generated by a pulse sha** setup. We particularly explore how the properties of the filament spectra can be controlled by parametrically tailored white light pulses. The experiments are carried out in a gas cell with up to 9 bar of argon. Plasma generation and self-phase modulation strongl…
▽ More
In this paper we examine the spectral changes in a white light laser filament due to different pulse shapes generated by a pulse sha** setup. We particularly explore how the properties of the filament spectra can be controlled by parametrically tailored white light pulses. The experiments are carried out in a gas cell with up to 9 bar of argon. Plasma generation and self-phase modulation strongly affect the pulse in the spectral and temporal domain. By exploiting these effects we show that the pulse spectrum can be modified in a desired way by either using second order parametric chirp functions to shift the filament spectrum to higher or lower wavelengths, or by optimizing pulse shapes with a genetic algorithm to generate more complex filament spectra. This paper is one of the first examples of the application of complex, parametrically shaped white light pulses.
△ Less
Submitted 7 September, 2018;
originally announced September 2018.
-
Maximizing energy deposition by sha** few-cycle laser pulses
Authors:
Julien Gateau,
Alexander Patas,
Mary Matthews,
Sylvain Hermelin,
Albrecht Lindinger,
Jérôme Kasparian,
Jean-Pierre Wolf
Abstract:
We experimentally investigate the impact of pulse shape on the dynamics of laser-generated plasma in rare gases. Fast-rising triangular pulses with a slower decay lead to early ionization of the air and depose energy more efficiently than their temporally reversed counterparts. As a result, in both argon and krypton, the induced shockwave as well as the plasma luminescence are stronger. This is du…
▽ More
We experimentally investigate the impact of pulse shape on the dynamics of laser-generated plasma in rare gases. Fast-rising triangular pulses with a slower decay lead to early ionization of the air and depose energy more efficiently than their temporally reversed counterparts. As a result, in both argon and krypton, the induced shockwave as well as the plasma luminescence are stronger. This is due to an earlier availability of free electrons to undergo inverse Bremsstrahlung on the pulse trailing edge. Our results illustrate the ability of adequately tailored pulse shapes to optimize the energy deposition in gas plasmas.
△ Less
Submitted 23 June, 2018;
originally announced June 2018.
-
Anisotropic super-attenuation of capillary waves on driven glass interfaces
Authors:
Bruno Bresson,
Coralie Brun,
Xavier Buet,
Yong Chen,
Matteo Ciccotti,
Jérôme Gâteau,
Greg Jasion,
Marco Petrovich,
Francesco Poletti,
David Richardson,
Seyed Sandoghchi,
Gilles Tessier,
Botond Tyukodi,
Damien Vandembroucq
Abstract:
Metrological AFM measurements are performed on the silica glass interfaces of photonic band-gap fibres and hollow capillaries. The freezing of attenuated out-of-equilibrium capillary waves during the drawing process is shown to result in a reduced surface roughness. The roughness attenuation with respect to the expected thermodynamical limit is determined to vary with the drawing stress following…
▽ More
Metrological AFM measurements are performed on the silica glass interfaces of photonic band-gap fibres and hollow capillaries. The freezing of attenuated out-of-equilibrium capillary waves during the drawing process is shown to result in a reduced surface roughness. The roughness attenuation with respect to the expected thermodynamical limit is determined to vary with the drawing stress following a power law. A striking anisotropic character of the height correlation is observed: glass surfaces thus retain a structural record of the direction of the flow to which the liquid was submitted.
△ Less
Submitted 6 June, 2017;
originally announced June 2017.
-
Triggering filamentation using turbulence
Authors:
D. Eeltink,
N. Berti,
N. Marchiando,
S. Hermelin,
J. Gateau,
M. Brunetti,
J. P. Wolf,
J. Kasparian
Abstract:
We study the triggering of single filaments due to turbulence in the beam path for a laser of power below the filamenting threshold. Turbulence can act as a switch between the beam not filamenting and producing single filaments. This 'positive' effect of turbulence on the filament probability, combined with our observation of off-axis filaments suggests the underlying mechanism is modulation insta…
▽ More
We study the triggering of single filaments due to turbulence in the beam path for a laser of power below the filamenting threshold. Turbulence can act as a switch between the beam not filamenting and producing single filaments. This 'positive' effect of turbulence on the filament probability, combined with our observation of off-axis filaments suggests the underlying mechanism is modulation instability caused by transverse perturbations. We hereby experimentally explore the interaction of modulation instability and turbulence, commonly associated with multiple-filaments, in the single-filament regime.
△ Less
Submitted 23 August, 2016;
originally announced August 2016.
-
Complementary Speckle Patterns : deterministic interchange of intrinsic vortices and maxima through Scattering Media
Authors:
Jérôme Gateau,
Hervé Rigneault,
Marc Guillon
Abstract:
Intensity minima and maxima of speckle patterns obtained behind a diffuser are experimentally interchanged by applying a spiral phase delay of charge $\pm 1$ to the im**ing coherent beam. This transform arises from the intuitive expectation that a tightly focused beam is so-changed into a vortex beam and vice-versa. The statistics of extrema locations and the intensity distribution of the so-gen…
▽ More
Intensity minima and maxima of speckle patterns obtained behind a diffuser are experimentally interchanged by applying a spiral phase delay of charge $\pm 1$ to the im**ing coherent beam. This transform arises from the intuitive expectation that a tightly focused beam is so-changed into a vortex beam and vice-versa. The statistics of extrema locations and the intensity distribution of the so-generated "complementary" patterns are characterized by numerical simulations. It is demonstrated experimentally that the incoherent superposition of the three "complementary speckle patterns" yield a synthetic speckle grain size enlarged by a factor $\sqrt{3}$. A cyclic permutation of optical vortices and maxima is unexpectedly observed and discussed.
△ Less
Submitted 22 July, 2016;
originally announced July 2016.
-
Super-resolution photoacoustic fluctuation imaging with multiple speckle illumination
Authors:
Thomas Chaigne,
Jérôme Gateau,
Marc Allain,
Ori Katz,
Sylvain Gigan,
Anne Sentenac,
Emmanuel Bossy
Abstract:
In deep tissue photoacoustic imaging, the spatial resolution is inherently limited by acoustic diffraction. Moreover, as the ultrasound attenuation increases with frequency, resolution is often traded-off for penetration depth. Here we report on super-resolution photoacoustic imaging by use of multiple speckle illumination. Specifically, we show that the analysis of second-order fluctuations of th…
▽ More
In deep tissue photoacoustic imaging, the spatial resolution is inherently limited by acoustic diffraction. Moreover, as the ultrasound attenuation increases with frequency, resolution is often traded-off for penetration depth. Here we report on super-resolution photoacoustic imaging by use of multiple speckle illumination. Specifically, we show that the analysis of second-order fluctuations of the photoacoustic images combined with image deconvolution enables resolving optically absorbing structures beyond the acoustic diffraction limit. A resolution increase of almost a factor 2 is demonstrated experimentally. Our method introduces a new framework that could potentially lead to deep tissue photoacoustic imaging with sub-acoustic resolution.
△ Less
Submitted 6 August, 2015;
originally announced August 2015.
-
Optical-resolution photoacoustic imaging through thick tissue with a thin capillary as a dual optical-in acoustic-out waveguide
Authors:
Olivier Simandoux,
Nicolino Stasio,
Jerome Gateau,
Jean-Pierre Huignard,
Christophe Moser,
Demetri Psaltis,
Emmanuel Bossy
Abstract:
We demonstrate the ability to guide high-frequency photoacoustic waves through thick tissue with a water-filled silica-capillary (150 μm inner diameter and 30 mm long). An optical-resolution photoacoustic image of a 30 μm diameter absorbing nylon thread was obtained by guiding the acoustic waves in the capillary through a 3 cm thick fat layer. The transmission loss through the capillary was about…
▽ More
We demonstrate the ability to guide high-frequency photoacoustic waves through thick tissue with a water-filled silica-capillary (150 μm inner diameter and 30 mm long). An optical-resolution photoacoustic image of a 30 μm diameter absorbing nylon thread was obtained by guiding the acoustic waves in the capillary through a 3 cm thick fat layer. The transmission loss through the capillary was about -20 dB, much lower than the -120 dB acoustic attenuation through the fat layer. The overwhelming acoustic attenuation of high-frequency acoustic waves by biological tissue can therefore be avoided by the use of a small footprint capillary acoustic waveguide for remote detection. We finally demonstrate that the capillary can be used as a dual optical-in acoustic-out waveguide, paving the way for the development of minimally invasive optical-resolution photoacoustic endoscopes free of any acoustic or optical elements at their imaging tip.
△ Less
Submitted 8 February, 2015;
originally announced February 2015.
-
Single-side access, isotropic resolution and multispectral 3D photoacoustic imaging with rotate-translate scanning of ultrasonic detector array
Authors:
Jérôme Gateau,
Marc Gesnik,
Jean-Marie Chassot,
Emmanuel Bossy
Abstract:
Photoacoustic imaging can achieve high-resolution three-dimensional visualization of optical absorbers at penetration depths ~ 1 cm in biological tissues by detecting optically-induced high ultrasound frequencies. Tomographic acquisition with ultrasound linear arrays offers an easy implementation of single-side access, parallelized and high-frequency detection, but usually comes with an image qual…
▽ More
Photoacoustic imaging can achieve high-resolution three-dimensional visualization of optical absorbers at penetration depths ~ 1 cm in biological tissues by detecting optically-induced high ultrasound frequencies. Tomographic acquisition with ultrasound linear arrays offers an easy implementation of single-side access, parallelized and high-frequency detection, but usually comes with an image quality impaired by the directionality of the detectors. Indeed, a simple translation of the array perpendicularly to its median imaging plane is often used, but results both in a poor resolution in the translation direction and in strong limited view artifacts. To improve the spatial resolution and the visibility of complex structures while kee** a planar detection geometry, we introduce, in this paper, a novel rotate-translate scanning scheme, and investigate the performance of a scanner implemented at 15 MHz center frequency. The developed system achieved a quasi-isotropic uniform 3D resolution of ~170 um over a cubic volume of side length 8.5 mm, i.e. an improvement in the resolution in the translation direction by almost one order of magnitude. Dual wavelength imaging was also demonstrated with ultrafast wavelength shifting. The validity of our approach was shown in vitro. We discuss the ability to enable in vivo imaging for preclinical and clinical studies.
△ Less
Submitted 14 May, 2015; v1 submitted 27 January, 2015;
originally announced January 2015.
-
Light Focusing and Two-Dimensional Imaging Through Scattering Media using the Photoacoustic Transmission-Matrix with an Ultrasound Array
Authors:
Thomas Chaigne,
Jerome Gateau,
Ori Katz,
Emmanuel Bossy,
Sylvain Gigan
Abstract:
We implement the photoacoustic transmission-matrix approach on a two-dimensional photoacoustic imaging system, using a 15 MHz linear ultrasound array. Using a black leaf skeleton as a complex absorbing structure, we demonstrate that the photoacoustic transmission-matrix approach allows to reveal structural features that are invisible in conventional photoacoustic images, as well as to selectively…
▽ More
We implement the photoacoustic transmission-matrix approach on a two-dimensional photoacoustic imaging system, using a 15 MHz linear ultrasound array. Using a black leaf skeleton as a complex absorbing structure, we demonstrate that the photoacoustic transmission-matrix approach allows to reveal structural features that are invisible in conventional photoacoustic images, as well as to selectively control light focusing on absorbing targets, leading to a local enhancement of the photoacoustic signal.
△ Less
Submitted 2 February, 2014;
originally announced February 2014.
-
Improving Photoacoustic-guided Focusing in Scattering Media by Spectrally Filtered Detection
Authors:
Thomas Chaigne,
Ori Katz,
Jérôme Gateau,
Claude Boccara,
Sylvain Gigan,
Emmanuel Bossy
Abstract:
We experimentally and numerically study the potential of photoacoustic-guiding for light focusing through scattering samples via wavefront-sha** and iterative optimization. We experimentally demonstrate that the focusing efficiency on an extended absorber can be improved by iterative optimization of the high frequency components of the broadband photoacoustic signal detected with a spherically f…
▽ More
We experimentally and numerically study the potential of photoacoustic-guiding for light focusing through scattering samples via wavefront-sha** and iterative optimization. We experimentally demonstrate that the focusing efficiency on an extended absorber can be improved by iterative optimization of the high frequency components of the broadband photoacoustic signal detected with a spherically focused transducer. We demonstrate more than 8-fold increase in the photoacoustic signal generated by a 30 microns wire using a narrow frequency band around 60MHz. We numerically confirm that such optimization leads to a smaller optical focus than using the low frequency content of the photoacoustic feedback.
△ Less
Submitted 28 October, 2013;
originally announced October 2013.
-
Influence of nanoscale temperature rises on photoacoustic generation: discrimination between optical absorbers based on nonlinear photoacoustics at high frequency
Authors:
Oliver Simandoux,
Amaury Prost,
Jérôme Gâteau,
Emmanuel Bossy
Abstract:
In the thermoelastic regime, photoacoustic sensing of optical absorption relies on conversion from light to acoustic energy via the coefficient of thermal expansion β. In this work, we confront confront experimental measurements to theoretical predictions of nonlinear photoacoustic generation based on the dynamic variation of β(T) during the optical excitation of absorbers in aqueous solution. The…
▽ More
In the thermoelastic regime, photoacoustic sensing of optical absorption relies on conversion from light to acoustic energy via the coefficient of thermal expansion β. In this work, we confront confront experimental measurements to theoretical predictions of nonlinear photoacoustic generation based on the dynamic variation of β(T) during the optical excitation of absorbers in aqueous solution. The photoacoustic generation from solutions of organic dye and gold nanospheres (with same optical densities), illuminated with 532 nm nanosecond pulses, was detected using a high frequency ultrasound transducer (center frequency 20 MHz). Photoacoustic emission was observed with gold nanospheres at low fluence (a few mJ/cm2) for an equilibrium temperature around 4°C, where the linear photoacoustic effect in water vanishes, highlighting the nonlinear emission from the solution of nanospheres. Under the same condition, no emission was observed with the absorbing organic dye. At a fixed fluence of 5 mJ/cm2, the photoacoustic amplitude was studied as a function of the equilibrium temperature from 2°C to 20°C. While the photoacoustic amplitude from the organic dye followed β(T) in water and vanished around 4°C, the photoacoustic amplitude from the gold nanospheres remained significant over the whole temperature range. These experimental results are shown to be in qualitative agreement with theoretical calculations based on the nanoscale and nanosecond transient changes of the coefficient of thermal expansion of water around the gold nanospheres. Our results suggest that in the context of high frequency photoacoustic imaging, nanoparticles may be discriminated from molecular absorbers based on either the nonlinear fluence-dependence or the equilibrium temperature-dependence of the photoacoustic amplitude.
△ Less
Submitted 26 September, 2013;
originally announced September 2013.
-
Improving visibility in photoacoustic imaging using dynamic speckle illumination
Authors:
Jérôme Gateau,
Thomas Chaigne,
Ori Katz,
Sylvain Gigan,
Emmanuel Bossy
Abstract:
In high-frequency photoacoustic imaging with uniform illumination, homogeneous photo-absorbing structures may be invisible because of their large size or limited-view issues. Here we show that, by exploiting dynamic speckle illumination, it is possible to reveal features which are normally invisible with a photoacoustic system comprised of a 20MHz linear ultrasound array. We demonstrate imaging of…
▽ More
In high-frequency photoacoustic imaging with uniform illumination, homogeneous photo-absorbing structures may be invisible because of their large size or limited-view issues. Here we show that, by exploiting dynamic speckle illumination, it is possible to reveal features which are normally invisible with a photoacoustic system comprised of a 20MHz linear ultrasound array. We demonstrate imaging of a 5 mm diameter absorbing cylinder and a 30 micrometer black thread arranged in a complex shape. The hidden structures are directly retrieved from photoacoustic images recorded for different random speckle illuminations of the phantoms by assessing the variation in the value of each pixel over the illumination patterns.
△ Less
Submitted 5 November, 2013; v1 submitted 1 August, 2013;
originally announced August 2013.