The Dynamic Transition of Protein Hydration Water
Authors:
W. Doster,
S. Busch,
A. M. Gaspar,
M. -S. Appavou,
J. Wuttke,
H. Scheer
Abstract:
Thin layers of water on biomolecular and other nanostructured surfaces can be supercooled to temperatures not accessible with bulk water. Chen et al. [PNAS 103, 9012 (2006)] suggested that anomalies near 220 K observed by quasi-elastic neutron scattering can be explained by a hidden critical point of bulk water. Based on more sensitive measurements of water on perdeuterated phycocyanin, using th…
▽ More
Thin layers of water on biomolecular and other nanostructured surfaces can be supercooled to temperatures not accessible with bulk water. Chen et al. [PNAS 103, 9012 (2006)] suggested that anomalies near 220 K observed by quasi-elastic neutron scattering can be explained by a hidden critical point of bulk water. Based on more sensitive measurements of water on perdeuterated phycocyanin, using the new neutron backscattering spectrometer SPHERES, and an improved data analysis, we present results that show no sign of such a fragile-to-strong transition. The inflection of the elastic intensity at 220 K has a dynamic origin that is compatible with a calorimetric glass transition at 170 K. The temperature dependence of the relaxation times is highly sensitive to data evaluation; it can be brought into perfect agreement with the results of other techniques, without any anomaly.
△ Less
Submitted 12 February, 2010; v1 submitted 26 November, 2009;
originally announced November 2009.
Methods for analytically estimating the resolution and intensity of neutron time-of-flight spectrometers. The case of the TOFTOF spectrometer
Authors:
Ana M Gaspar
Abstract:
An analytical method is presented with allows to estimate the energy resolution of time-of-flight neutron spectrometers, as well as its partial contributions, over a dynamical range that extends from the elastic line to the accessible inelastic regions. Such a method, already successfully applied in the past to the TOSCA and HET neutron inelastic scattering spectrometers installed at the ISIS ne…
▽ More
An analytical method is presented with allows to estimate the energy resolution of time-of-flight neutron spectrometers, as well as its partial contributions, over a dynamical range that extends from the elastic line to the accessible inelastic regions. Such a method, already successfully applied in the past to the TOSCA and HET neutron inelastic scattering spectrometers installed at the ISIS neutron spallation source [A M Gaspar, PhD Thesis, Universidade Tecnica de Lisboa, 2004], is here applied to the high resolution time-of-flight spectrometer TOFTOF, mainly dedicated to quasi-elastic neutron scattering studies and installed at the new neutron reactor FRM II. To make such calculations easily understandable, the principle of work of the TOFTOF instrument and of each of its components is explained in detail. A simply method that can be used to estimate the instrument intensity, i.e. of the number of neutrons arriving at the sample position per unit time, is also briefly outlined.
To the benefit of the TOFTOF users, graphs displaying the dependencies of the instrument resolution at the elastic line and of the instrument intensity on the relevant instrument parameters, i.e the wavelength of the incident neutrons, the choppers speed of rotation and the frame overlap ratio, are presented, in the form of iso-resolution or iso-intensity lines. The method of estimation of the frame overlap ratio that is commonly used at time-of-flight instruments such as TOFTOF is also explained and alternative options concerning this parameter, depending on the dynamical range of interest, are briefly addressed.
△ Less
Submitted 28 October, 2007;
originally announced October 2007.