-
Overview of the High-Definition X-ray Imager instrument on the Lynx x-ray surveyor
Authors:
Abraham D. Falcone,
Ralph P. Kraft,
Marshall W. Bautz,
Jessica A. Gaskin,
John A. Mulqueen,
Doug A. Swartz
Abstract:
Four NASA Science and Technology Definition Teams have been convened in order to develop and study four mission concepts to be evaluated by the upcoming 2020 Decadal Survey. The Lynx x-ray surveyor mission is one of these four large missions. Lynx will couple fine angular resolution (<0.5 arcsec HPD) x-ray optics with large effective area (~2 m^2 at 1 keV), thus enabling exploration within a uniqu…
▽ More
Four NASA Science and Technology Definition Teams have been convened in order to develop and study four mission concepts to be evaluated by the upcoming 2020 Decadal Survey. The Lynx x-ray surveyor mission is one of these four large missions. Lynx will couple fine angular resolution (<0.5 arcsec HPD) x-ray optics with large effective area (~2 m^2 at 1 keV), thus enabling exploration within a unique scientific parameter space. One of the primary soft x-ray imaging instruments being baselined for this mission concept is the high-definition x-ray imager, HDXI. This instrument would use a finely pixelated silicon sensor array to achieve fine angular resolution imaging over a wide field of view (~22 x 22 arcmin). Silicon sensors enable large-format/small-pixel devices, radiation tolerant designs, and high quantum efficiency across the entire soft x-ray bandpass. To fully exploit the large collecting area of Lynx (~30x Chandra), with negligible or minimal x-ray event pile-up, the HDXI will be capable of much faster frame rates than current x-ray imagers. We summarize the planned requirements, capabilities, and development status of the HDXI instrument, and associated papers in this special edition will provide further details on some specific detector options.
△ Less
Submitted 21 June, 2019;
originally announced June 2019.
-
Astro2020 Science White Paper: Using X-Ray Polarimetry to Probe the Physics of Black Holes and Neutron Stars
Authors:
Henric Krawczynski,
Giorgio Matt,
Adam R. Ingram,
Roberto Taverna,
Roberto Turolla,
Fabian Kislat,
C. C. Teddy Cheung,
Andrei Bykov,
Kuver Sinha,
Haocheng Zhang,
Jeremy Heyl,
Niccolo Bucciantini,
Greg Madejski,
Tim Kallman,
Keith M. Jahoda,
Quin Abarr,
Matthew G. Baring,
Luca Baldini,
Mitchell Begelman,
Markus Boettcher,
Edward Cackett,
Ilaria Caiazzo,
Paolo Coppi,
Enrico Costa,
Jason Dexter
, et al. (32 additional authors not shown)
Abstract:
This white paper highlights compact object and fundamental physics science opportunities afforded by high-throughput broadband (0.1-60 keV) X-ray polarization observations. X-ray polarimetry gives new observables with geometric information about stellar remnants which are many orders of magnitude too small for direct imaging. The X-ray polarimetric data also reveal details about the emission mecha…
▽ More
This white paper highlights compact object and fundamental physics science opportunities afforded by high-throughput broadband (0.1-60 keV) X-ray polarization observations. X-ray polarimetry gives new observables with geometric information about stellar remnants which are many orders of magnitude too small for direct imaging. The X-ray polarimetric data also reveal details about the emission mechanisms and the structure of the magnetic fields in and around the most extreme objects in the Universe. Whereas the Imaging X-ray Polarimetry Explorer (IXPE) to be launched in 2021 will obtain first results for bright objects, a follow-up mission could be one order of magnitude more sensitive and would be able to use a broader bandpass to perform physics type experiments for representative samples of sources.
△ Less
Submitted 19 April, 2019;
originally announced April 2019.
-
Demonstration of resolving power $λ/Δλ> 10,000$ for a space-based x-ray transmission grating spectrometer
Authors:
Ralf K. Heilmann,
Jeffery Kolodziejczak,
Alexander R. Bruccoleri,
Jessica A. Gaskin,
Mark L. Schattenburg
Abstract:
We present measurements of the resolving power of a soft x-ray spectrometer consisting of 200 nm-period lightweight, alignment-insensitive critical-angle transmission (CAT) gratings and a lightweight slumped-glass Wolter-I focusing mirror pair. We measure and model contributions from source, mirrors, detector pixel size, and grating period variation to the natural line width spectrum of the Al and…
▽ More
We present measurements of the resolving power of a soft x-ray spectrometer consisting of 200 nm-period lightweight, alignment-insensitive critical-angle transmission (CAT) gratings and a lightweight slumped-glass Wolter-I focusing mirror pair. We measure and model contributions from source, mirrors, detector pixel size, and grating period variation to the natural line width spectrum of the Al and Mg K$_{α_1 α_2}$ doublets. Measuring up to 18$^{\rm th}$ diffraction order at characteristic Al-K wavelengths we consistently obtain small broadening due to gratings corresponding to a minimum effective grating resolving power $R_g > 10,000$ with 90\% confidence. Upper limits are often compatible with $R_g = \infty$. Independent fitting of different diffraction orders, as well as ensemble fitting of multiple orders at multiple wavelengths, gives compatible results. Our data leads to uncertainties for the Al-K$_α$ doublet line width and line separation parameters 2-3 times smaller than values found in the literature. Data from three different gratings are mutually compatible. This demonstrates that CAT gratings perform in excess of the requirements for the Arcus Explorer mission and are suitable for next-generation space-based x-ray spectrometer designs with resolving power 5-10 times higher than the transmission grating spectrometer on the Chandra X-ray Observatory.
△ Less
Submitted 19 December, 2018;
originally announced December 2018.
-
The High Definition X-ray Imager (HDXI) Instrument on the Lynx X-Ray Surveyor
Authors:
Abraham D. Falcone,
Ralph P. Kraft,
Marshall W. Bautz,
Jessica A. Gaskin,
John A. Mulqueen,
Doug A. Swartz
Abstract:
The Lynx X-ray Surveyor Mission is one of 4 large missions being studied by NASA Science and Technology Definition Teams as mission concepts to be evaluated by the upcoming 2020 Decadal Survey. By utilizing optics that couple fine angular resolution (<0.5 arcsec HPD) with large effective area (~2 m^2 at 1 keV), Lynx would enable exploration within a unique scientific parameter space. One of the pr…
▽ More
The Lynx X-ray Surveyor Mission is one of 4 large missions being studied by NASA Science and Technology Definition Teams as mission concepts to be evaluated by the upcoming 2020 Decadal Survey. By utilizing optics that couple fine angular resolution (<0.5 arcsec HPD) with large effective area (~2 m^2 at 1 keV), Lynx would enable exploration within a unique scientific parameter space. One of the primary soft X-ray imaging instruments being baselined for this mission concept is the High Definition X-ray Imager, HDXI. This instrument would achieve fine angular resolution imaging over a wide field of view (~ 22 x 22 arcmin, or larger) by using a finely-pixelated silicon sensor array. Silicon sensors enable large-format/small-pixel devices, radiation tolerant designs, and high quantum efficiency across the entire soft X-ray bandpass. To fully exploit the large collecting area of Lynx (~30x Chandra), without X-ray event pile-up, the HDXI will be capable of much faster frame rates than current X-ray imagers. The planned requirements, capabilities, and development status of the HDXI will be described.
△ Less
Submitted 13 July, 2018;
originally announced July 2018.
-
Critical-angle x-ray transmission grating spectrometer with extended bandpass and resolving power > 10,000
Authors:
Ralf K. Heilmann,
Alexander R. Bruccoleri,
Jeffery Kolodziejczak,
Jessica A. Gaskin,
Stephen L. O'Dell,
Ritwik Bhatia,
Mark L. Schattenburg
Abstract:
Several high priority subjects in astrophysics can be addressed by a state-of-the-art soft x-ray grating spectrometer (XGS). An Explorer-scale, large-area (> 1,000 cm2), high resolving power (R > 3,000) XGS is highly feasible based on Critical-Angle Transmission (CAT) gratings, even for telescopes with angular resolution of 5-10 arcsec. Significantly higher performance can be provided by a CAT XGS…
▽ More
Several high priority subjects in astrophysics can be addressed by a state-of-the-art soft x-ray grating spectrometer (XGS). An Explorer-scale, large-area (> 1,000 cm2), high resolving power (R > 3,000) XGS is highly feasible based on Critical-Angle Transmission (CAT) gratings, even for telescopes with angular resolution of 5-10 arcsec. Significantly higher performance can be provided by a CAT XGS on an X-ray-Surveyor-type mission. CAT gratings combine the advantages of blazed reflection gratings (high efficiency, use of higher diffraction orders) with those of transmission gratings (low mass, relaxed alignment and temperature requirements, transparent at high energies) with minimal mission resource demands. They are high-efficiency blazed transmission gratings that consist of freestanding, ultra-high aspect-ratio grating bars made from SOI wafers using anisotropic dry and wet etch techniques. Blazing is achieved through reflection off grating bar sidewalls. Silicon is well matched to the soft x-ray band, and existing silicon CAT gratings exceed 30% absolute diffraction efficiency, with clear paths for improvement. CAT gratings coated with heavier elements allow extension of the CAT grating principle to higher energies and larger angles, enabling higher resolving power at shorter wavelengths. We show x-ray data from CAT gratings coated with platinum using atomic layer deposition, and demonstrate blazing to higher energies and much larger blaze angles than possible with silicon. We measure resolving power of a CAT XGS consisting of a Wolter-I focusing mirror pair from GSFC and CAT gratings, performed at the MSFC SLF. Measurement of the Al Ka doublet in 18th order shows resolving power > 10,000, based on preliminary analysis. This demonstrates that currently fabricated CAT gratings are compatible with the most advanced XGS designs for future soft x-ray spectroscopy missions.
△ Less
Submitted 15 July, 2016;
originally announced July 2016.
-
High Resolution Optics & Detector Systems for Hard X-rays
Authors:
D. P. Sharma,
B. D. Ramsey,
J. A. Gaskin,
D. Engelhaupt,
C. Speegle,
J. Apple,
M. H. Finger
Abstract:
We describe development of hard x-ray focusing optics telescopes at the National Space Science and Technology Center (NSSTC).
We describe development of hard x-ray focusing optics telescopes at the National Space Science and Technology Center (NSSTC).
△ Less
Submitted 14 October, 2003;
originally announced October 2003.
-
The Mass, Baryonic Fraction, and X-ray Temperature of the Luminous, High Redshift Cluster of Galaxies, MS0451.6-0305
Authors:
Megan Donahue,
Jessica A. Gaskin,
Sandeep K. Patel,
Marshall Joy,
Doug Clowe,
John P. Hughes
Abstract:
We present new Chandra X-ray observations of the luminous X-ray cluster, MS0451.6-0305, at z=0.5386. Spectral imaging data for the cluster are consistent with an isothermal cluster of 10.0 - 10.6 +/-1.6 keV and an Fe abundance of 0.32-0.40 +/-0.13 solar. The systematic uncertainties, arising from calibration and model uncertainties, of the temperature determination are nearly the same size as th…
▽ More
We present new Chandra X-ray observations of the luminous X-ray cluster, MS0451.6-0305, at z=0.5386. Spectral imaging data for the cluster are consistent with an isothermal cluster of 10.0 - 10.6 +/-1.6 keV and an Fe abundance of 0.32-0.40 +/-0.13 solar. The systematic uncertainties, arising from calibration and model uncertainties, of the temperature determination are nearly the same size as the statistical uncertainties. We discuss the effects of the ACIS absorption correction on the spectral fitting. The effects of statistics and fitting assumptions of 2-D models for the X-ray surface brightness are thoroughly explored. This cluster appears to be elongated and so we quantify the effects of assuming an ellipsoidal gas distribution on the gas mass and the total gravitating mass estimates. These data are also jointly fit with previous S-Z observations to obtain an estimate of the cluster's distance assuming spherical symmetry. If we, instead, assume a Hubble constant, the X-ray and S-Z data are used together to test the consistency of an ellipsoidal gas distribution and to weakly constrain the intrinsic axis ratio. The mass derived from the X-ray data is consistent with the weak lensing and optical masses. We confirm that this cluster is very hot and massive, further supporting the conclusion of previous analyses that the universe has a low matter density and that cluster properties, including iron abundances, have not evolved much since z~0.5. We discuss the possible detection of a faint, soft, extended component that may be the by-product of hierarchical structure formation.
△ Less
Submitted 1 August, 2003;
originally announced August 2003.